• Title/Summary/Keyword: 원통의 중심부

Search Result 7, Processing Time 0.022 seconds

FEM Electrical Resistivity Modeling in Cylindrical Coordinates (원통 좌표계에서의 전기비저항 유한요소 모델링)

  • Choi Wonseok;Kim Jung-Ho;Park KwonGyu;Kim Hak-Soo;Suh Jung-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.3
    • /
    • pp.206-216
    • /
    • 2002
  • The finite element method (FEM), a powerful numerical modeling tool for solving various engineering problems, is frequently applied to three-dimensional (3-D) modeling thanks to its capability of discretizing and simulating the shape of model with finite number of elements. Considering the accuracy of the solution and computing time in modeling of engineering problems, it is preferable to construct physical continuity and simplify mesh system. Although there exist systematic mesh generation systems for arbitrary shaped model, it is hard to model a simple cylinder in terms of 3-D coordinate system especially in the vicinity of the central axis. In this study I adopt cylindrical coordinate system for modeling the 3-D model space and define the origin of the coordinates with mathematically clear coordinate transformation. Since we can simulate the whole space with hexahedral elements, the cylindrical coordinate system is effective in handling the 3-D model structure. The 3-D do resistivity modeling scheme developed in this study provides basie principle for borehole-to-surface resistivity survey, which can be a useful tool for the application to environmental problem.

Finite Element Analyses on Ultimate Compressive Strength of Longitudinally Stiffened Polygonal Sections (종방향 보강재로 보강된 다각형 단면 기둥구조의 극한강도 해석)

  • Choi, Byung Ho;Park, Seong Mi;Hwang, Min Oh
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.40-40
    • /
    • 2011
  • 현재 일반적으로 활용되고 있는 원통형 쉘구조로 이루어진 타워구조의 대형화가 추진되면서 제작, 운반 편의성, 단면효율성, 경제성 제고를 위해 다각형단면 기둥구조물의 활용이 대두되고 있다. 하지만 다각형 단면 기둥구조의 극한강도에 대한 자료가 충분치 않고 관련 기준이나 지침이 명확히 제시되고 있지 않은 실정이다. 본 연구에서는 원통형 쉘구조물을 다각형구조물로 대체하여 제작될 경우 축방향 압축에 대한 내하력 향상 효과를 수치해석적으로 검토해 보고자 한다. 해석모델은 지름 2m, 두께 20mm인 원형강관 프로토타입 풍력타워 구조를 참고로 하여 이에 내접하도록 결정한 6~12각형 단면 형상으로써 높이 10,000mm인 3차원 기둥모델을 구현하였고 유한요소프로그램인 ABAQUS를 이용하여 해석하였다. 각 subpanel의 중앙에 종방향 보강재를 설치하였을 때 국부좌굴에 대한 내하력 변화를 비교하기 위해 종방향보강재로 보강한 모델을 구성하여 비교 해석을 수행하였다. 종방향 보강재의 제원은 미국 SSRC 제안식을 기준으로 삼았다. 탄성좌굴해석을 통해 탄성좌굴모드 형상을, 비선형비탄성해석을 통해 최종파괴모드 및 극한강도를 얻었다. 보강 전 후의 탄성좌굴 해석 결과로부터 최소모드의 고유치 값을 비교하였다. 각 subpanel 단면 중심부에 한 개의 보강재를 설치한 경우 탄성좌굴강도가 4배 가량 증가하였다. 이로부터, 보강재(n=1) 설치에 따라 유효 폭두께비가 1/2로 감소하는 효과를 확인 할 수 있다. 비선형해석결과로부터 subpanel의 단면중심에 보강재를 설치한 경우 보강재가 위치한 곳에 고정점이 형성되어 이를 중심으로 국부 좌굴모드에 변화가 생기는 것이 확인되었다. 이러한 변화는 다각형 단면 기둥구조의 내하력 성능, 즉 국부좌굴강도에 영향을 준다. 충분한 강성을 갖는 종방향 보강재가 설치된 경우, 극한상태에서도 유효폭두께비가 줄어드는 것과 같은 강도 향상 효과를 확인할 수 있다. 이러한 사실은 각 해석결과 극한강도를 DIN code, Migita와 Fukumoto의 제안식, SSRC 설계제안식 등과의 비교를 통해 확인할 수 있었다.

  • PDF

Plasma Sources for Production of High Flux Particle Beams in Hyperthermal Energy Range (하이퍼써멀 에너지 영역에서 높은 플럭스 입자빔 생성을 위한 플라즈마 발생원)

  • Yoo, S.J.;Kim, S.B.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.3
    • /
    • pp.186-196
    • /
    • 2009
  • Since it is difficult to extract a high flux ion beam directly at an energy of hyperthermal range ($1{\sim}100\;eV$), especially, lower than 50 eV, the ions should be neutralized into neutral particles and extracted as a neutral beam. A plasma source required to generate and efficiently transport high flux hyperthermal neutral beams should be easily scaled up and produce a high ion density (${\ge}10^{11}\;cm^{-3}$) even at a low working pressure (${\le}$ 0.3 mTorr). It is suggested that the required plasma source can be realized by Electron Cyclotron Resonance (ECR) plasmas with diverse magnetic field configurations of permanent magnets such as a planar ECR plasma source with magnetron field configuration and cylindrical one with axial magnetic fields produced by permanent magnet arrays around chamber wall. In both case of the ECR sources, the electron confinement is based on the simple mirror field structure and efficiently enhanced by electron drifts for producing the high density plasma even at the low pressure.

Study on the Fluid Dynamics Modeling in Artificial Lung Assist Device (인공 폐 보조장치 내에서의 유체 유동 모델링에 대한 연구)

  • Kim, Gi-Beum;Park, Young-Ran;Kim, Shang-Jin;Hong, Chul-Un;Kang, Hyung-Sub;Kim, Jin-Shang;Kim, Seong-Jong;Kim, Min-Ho
    • Korean Chemical Engineering Research
    • /
    • v.49 no.2
    • /
    • pp.230-237
    • /
    • 2011
  • In this study, the characteristic of fluid flow in the new type lung assist devices has been established using computational fluid dynamics(CFD). For the modeling, the hollow fiber was ignored, and vertical types and tangential types were used for the model. Which was to analyze the flow characteristics of the fluid flow model when there exists 1 and 2 input/output ports, and when the input/output ports is located at the center of the cylinder and at the tangential direction with the cylinder wall. The modeling results showed that it was possible to eliminate no-flow region(stagnant layer) as shown in the vertical type when an inlet and an outlet were installed on the tangential direction of the cylinder as shown in the tangential type. Also, in the tangential type, vortex-type flow appeared as dominant, and it showed a complicated flow not deviated to one side. When the number of input/output was two, there was no deviated flow, and complicated flows were generated all across the tube. From the test result, it was found that input/output of flow was tangential type and complicated flows with no stagnant layer would be generated when there are two inputs/outputs, respectively.

Effect of Weber Number and Momentum Flux Ratio on Macroscopic Characteristics of Spray from a Coaxial Porous Injector (웨버수 및 운동량 플럭스비에 따른 동축형 다공성재 분사기의 거시적 분무특성)

  • Kim, Do-Hun;Seo, Min-Kyo;Lee, In-Chul;Koo, Ja-Ye
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.5
    • /
    • pp.1-9
    • /
    • 2012
  • The gas jet from a coaxial porous injector for two-phase flows is discharged from the porous surface, which encloses the center liquid jet, and the gas and liquid jet interact with each other physically. The wall injected gas jet transfers the radial momentum effectively while the radial gas jet develops to axial jet, and the performance of atomizing and mixing can be improved. In this study, the Weber number and the ratio of momentum flux were controlled by changing the gas injection area and the mass flow rate of the gas jet, and a study on the spray characteristics at the cold-flow test using water and air simulant was performed. It is concluded that the radial momentum transfer concept of a coaxial porous injector gives a positive effect on the atomization and mixing of the two-phase spray.

Thickness Control of Electroplating Layer for Copper Pillar Tin Bump (구리기둥범프 용 전해도금 층 제어)

  • Moon, Dae-Ho;Hong, Sang-Jeen;Park, Jong-Dae;Hwang, Jae-Ryong;Soh, Dea-Wha
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.903-906
    • /
    • 2011
  • The electroplating and electro-less plating methods have been applied for the high density chip interconnect of the Copper Pillar Tin Bump (CPTB) preparation. The CPTB was prepared, which had been electroplated about $100{\mu}m$ pitch of copper layer firstly, and then the Tin layer was deposited on the copper pillar surface to protect the oxidation of it. It was also very important to get uniform thickness of electroplated copper layer, though it was difficult and sensitive. In order to control the thickness distribution, it was examined that the current separating disk of Insulating Gate with a hole in the center was installed between electrodes. The current flows through the center hole of the Insulating Gate in the cylindrical electroplating bath and the other parts were blocked to protect current flowing. The main current flowed through the center hole of the Insulating Gate directly to the opposite electrode of wafer disk. As the results, it was verified that the copper layer was thick in the center part of wafer disk with distribution of thinner to the outer part toward edge.

  • PDF

Study of Scatter Influence of kV-Conebeam CT Based Calculation for Pelvic Radiotherapy (골반 방사선 치료에서 산란이 kV-Conebeam CT 영상 기반의 선량계산에 미치는 영향에 대한 연구)

  • Yoon, KyoungJun;Kwak, Jungwon;Cho, Byungchul;Kim, YoungSeok;Lee, SangWook;Ahn, SeungDo;Nam, SangHee
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.37-45
    • /
    • 2014
  • The accuracy and uniformity of CT numbers are the main causes of radiation dose calculation error. Especially, for the dose calculation based on kV-Cone Beam Computed Tomography (CBCT) image, the scatter affecting the CT number is known to be quite different by the object sizes, densities, exposure conditions, and so on. In this study, the scatter impact on the CBCT based dose calculation was evaluated to provide the optimal condition minimizing the error. The CBCT images was acquired under three scatter conditions ("Under-scatter", "Over-scatter", and "Full-scatter") by adjusting amount of scatter materials around a electron density phantom (CIRS062, Tissue Simulation Technology, Norfolk, VA, USA). The CT number uniformities of CBCT images for water-equivalent materials of the phantom were assessed, and the location dependency, either "inner" or "outer" parts of the phantom, was also evaluated. The electron density correction curves were derived from CBCT images of the electron density phantom in each scatter condition. The electron density correction curves were applied to calculate the CBCT based doses, which were compared with the dose based on Fan Beam Computed Tomography (FBCT). Also, 5 prostate IMRT cases were enrolled to assess the accuracy of dose based on CBCT images using gamma index analysis and relative dose differences. As the CT number histogram of phantom CBCT images for water equivalent materials was fitted with a gaussian function, the FHWM (146 HU) for "Full-scatter" condition was the smallest among the FHWM for the three conditions (685 HU for "under scatter" and 264 HU for "over scatter"). Also, the variance of CT numbers was the smallest for the same ingredients located in the center and periphery of the phantom in the "Full-scatter" condition. The dose distributions calculated with FBCT and CBCT images compared in a gamma index evaluation of 1%/3 mm criteria and in the dose difference. With the electron density correction acquired in the same scatter condition, the CBCT based dose calculations tended to be the most accurate. In 5 prostate cases in which the mean equivalent diameter was 27.2 cm, the averaged gamma pass rate was 98% and the dose difference confirmed to be less than 2% (average 0.2%, ranged from -1.3% to 1.6%) with the electron density correction of the "Full-scatter" condition. The accuracy of CBCT based dose calculation could be confirmed that closely related to the CT number uniformity and to the similarity of the scatter conditions for the electron density correction curve and CBCT image. In pelvic cases, the most accurate dose calculation was achievable in the application of the electron density curves of the "Full-scatter" condition.