• Title/Summary/Keyword: 원소분석기

Search Result 538, Processing Time 0.025 seconds

Development of a Spectrum Analysis Software for Multipurpose Gamma-ray Detectors (감마선 검출기를 위한 스펙트럼 분석 소프트웨어 개발)

  • Lee, Jong-Myung;Kim, Young-Kwon;Park, Kil-Soon;Kim, Jung-Min;Lee, Ki-Sung;Joung, Jin-Hun
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.51-59
    • /
    • 2010
  • We developed an analysis software that automatically detects incoming isotopes for multi-purpose gamma-ray detectors. The software is divided into three major parts; Network Interface Module (NIM), Spectrum Analysis Module (SAM), and Graphic User Interface Module (GUIM). The main part is SAM that extracts peak information of energy spectrum from the collected data through network and identifies the isotopes by comparing the peaks with pre-calibrated libraries. The proposed peak detection algorithm was utilized to construct libraries of standard isotopes with two peaks and to identify the unknown isotope with the constructed libraries. We tested the software by using GammaPro1410 detector developed by NuCare Medical Systems. The results showed that NIM performed 200K counts per seconds and the most isotopes tested were correctly recognized within 1% error range when only a single unknown isotope was used for detection test. The software is expected to be used for radiation monitoring in various applications such as hospitals, power plants, and research facilities etc.

Array Localization for Multithreaded Code Generation (다중스레드 코드 생성을 위한 배열 지역화)

  • Yang, Chang-Mo;Yu, Won-Hui
    • The Transactions of the Korea Information Processing Society
    • /
    • v.3 no.6
    • /
    • pp.1407-1417
    • /
    • 1996
  • In recent researches on thread partitioning algorithms break a thread at the long latency operation and merge threads to get the longer threads under the given constraints. Due to this limitation, even a program with little parallelism is partitioned into small-sized threads and context-swithings occur frequently. In the paper, we propose another method array localization about the array name, dependence distance(the difference of accessed element index from loop index), and the element usage that indicates whether element is used or defined. Using this information we can allocate array elements to the node where the corresponding loop activation is executed. By array localization, remote accesses to array elements can be replaced with local accesses to localized array elements. As a resuit,the boundaries of some threads are removed, programs can be partitioned into the larger threads and the number of context switchings reduced.

  • PDF

The Improved Method for Precise Determination of Pu Isotope Ratio using MC-ICP-MS (다중검출기유도결합플라즈마질량분석기를 이용한 Pu 동위원소비 정밀 분석법)

  • Yim, Seong-A;Han, Eun-Mi;Chae, Jung-Seok;Yun, Ju-Young
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.3
    • /
    • pp.117-123
    • /
    • 2010
  • Plutonium is by far the most important of the transuranic elements which have been released into the environment due to radio-toxicity and long term radiation effects on humans. And Pu isotope ratio ($^{240}Pu/^{239}Pu$) is of great interest because this ratio is used as a fingerprint for different sources. Mass spectrometry has been used as an useful atom counting technique with several advantages over decay counting techniques for the determination of Pu isotopes. It enables a determination of Pu isotope ratio in the environmental samples with a low detection limit and a short determination time. An ICP-MS is the representative mass spectrometry for Pu determination. In this study, the precision of $^{240}Pu/^{239}Pu$ isotope ratio was improved by using 4 multiple ion counters of MC-ICP-MS. The detection limit of $^{239}Pu$ and $^{240}Pu$ were $0.10\;fg\;ml^{-1}$ ($0.24\;{\mu}Bq\;ml^{-1}$), $0.12\;fg\;ml^{-1}$ ($0.97\;{\mu}Bq\;ml^{-1}$), respectively. The relative standard deviation of $^{240}Pu/^{239}Pu$ isotope ratio was less than 1 % in trace level. The various reference materials (seawater, soil and sediment) were analyzed to verify this method and their analytical results were in good agreement with the certified (or recommended value) value.

Seasonality of shellfish gathering using oxygen isotope analysis of Crassostrea gigas from the Gagok-ri shell midden site, Dangjin (산소동위원소 분석을 이용한 당진 가곡리 패총 굴 (Crassostrea gigas) 의 채집 계절 연구)

  • An, Deogim;Lee, Insung
    • The Korean Journal of Malacology
    • /
    • v.30 no.1
    • /
    • pp.1-8
    • /
    • 2014
  • Oxygen isotope analysis was carried out on a oyster (Crassostrea gigas) from the neolithic age Gagok-ri shell midden site, Dangjin, Korea to determine the seasonality of shellfish gathering and site occupation. Isotope samples were taken from the hinge section of the left valve of the oyster. The isotope values of the shell range from -2.02‰ to -6.05‰ vs PDB. The isotope profile shows a seasonal temperature cycle, providing information related to seasonality of shellfish gathering. The isotope values towards the edge of the hinge are gradually increasing, suggesting progressively cooling and a fall period of shell gathering and site occupation. The result shows that the oxygen isotope analysis using oyster shell hinges can be used for archaeological seasonality studies.

The isobaric effect on the measurement of Gd isotopes by thermal ionization mass spectrometry (열이온화 질량분석기를 이용한 Gd 동위원소 측정에서 동중원소 영향)

  • Jeon, Young-Shin;Park, Jong-Ho;Joe, Kih-Soo;Han, Sun-Ho;Song, Kyuseok
    • Analytical Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.415-421
    • /
    • 2009
  • A study was performed to investigate the isobaric effects of impurities in isotope measurement of gadolinium by TIMS. Especially, the ratio of $^{155}Gd/^{158}Gd$ showed the higher value than that of natural gadolinium and also decreased as the measuring time increased. This phenomenon is considered to be due to the oxide form of La ($LaO^+$, m/z=155) causing to create a serious bias on the measurement of $^{155}Gd$ abundance by La as an impurity, and due to $LaO^+$ produced more than the $Gd^+$ in the early time which disappears as the time goes on because of lower melting point and ionization potential of La than Gd. Although isobaric effects from Ba($BaO^+$), Ce($CeO^+$), Sm($SmO^+$), La($LaO^+$), and $K_4{^+}$(m/z=156)-cluster were detected even when blank rhenium filaments were used, these could be avoided by preconditioning(baking out) the filament. And we found that the measurement of $GdO^+$ instead of $Gd^+$ is more suitable in avoiding the isobaric effect from impurities such as La, Ce and Ba in the measurement of Gd isotope only in case of absence or extremely low level of Yb, Sm, Dy, Er, Lu.

Abundane of Rare Earth Element in Duwon Meteorite and Its Geochchemical Significance (두원운석의 희토류원소 존재도 및 지구화학적 의의)

  • Lee Seung-Gu;Kim Kun-Han;Choi Byeon-Gak
    • The Journal of the Petrological Society of Korea
    • /
    • v.13 no.4
    • /
    • pp.238-243
    • /
    • 2004
  • Duwon meteorite was fallen on 23 November 1943 in Duwonmyeon, Goheung, Jeolanam-Do. We measured rare earth element abundance of Duwon meteorite by isotope dilution thermal ion mass spectrometry (ID-TIMS) and ICP-MS. As a result, except La and Ce, abundance of other rare earth element show a correspondence within 10% of error range. However, La and Ce show more than 70% in abundance, which is considered due to 1) experimental procedure or 2) inhomogeneity of sample. Leedey meteorite was fallen on 25 November 1943 in Dewey County, Oklahoma, USA. which suggested that fallen difference between Leedey and Duwon meteorites is only 2 days. Leedey and Duwon meteorites are classified as ordinary chondrite of L6 type. In Leedey chondrite-normalized REE pattern, Duwon meteorite shows nearly flattened, which suggests close relationship between Leedey and Duwon meteorites meteoritically or cosmochemically.

Molybdenum Isotope Analysis of Standard Reference Materials (표준물질을 이용한 몰리브덴 동위원소 분석)

  • Jo, Yunsoo;Kil, Youngwoo;Ryu, Jongsik;Seol, Junghwan;Nguyen, The Cong;Jung, Woochul;Park, Sanghee
    • Economic and Environmental Geology
    • /
    • v.49 no.2
    • /
    • pp.89-95
    • /
    • 2016
  • Mo isotope, one of highly redox-sensitive isotopes, has been shown to be useful tracers of geochemical processes. Many studies for Mo isotope have documented with the help of recently developed analysis tools, but it has not yet been documented in the Korea. In this study, we introduce two-stage column separation method of Mo using column tube (BioRad PolyPrep(R) column, 10 ml) and anion exchange resin (BioRad Resin AG(R) 1-X8, 200-400 mesh). Mo isotope ratios in the solid SRMs (BHVO-2, SDO-1, PACS-2) and liquid SRM (IAPSO) were measured on MC-ICP-MS (Multi-collector Inductively Coupled Plasma Mass Spectrometer) and then compared with reference Mo isotope ratios. Mo isotope ratios in our study overlap with reference Mo isotope ratios within analytical error.

Lu-Hf Isotopic Systematics and Its Applications for Geology (Lu-Hf 동위원소시스템의 지질학적 활용)

  • Choi, Sung Hi
    • The Journal of the Petrological Society of Korea
    • /
    • v.23 no.3
    • /
    • pp.229-237
    • /
    • 2014
  • The Lu-Hf isotope system, coupled with the advent of multiple collector inductively coupled plasma source mass spectrometry, is now widely utilized as a tracer for geological processes. The paper presents a comprehensive review on the principles of the Lu-Hf isotopes, and its current and potential applications to both geochronology and petrogenesis. Finally, based on the Lu-Hf isotopic data from Korean mafic and ultramafic rocks, its has been discussed evolution of the mantle beneath the Korean Peninsula.

Silicon Isotope Measurement of Giant Diatoms Using MC-ICP-MS (다검출기 유도결합 플라즈마 질량분석기를 이용한 대형 규조류 규소 동위원소 분석법)

  • Choi, Ah Yeong;Ryu, Jong-Sik;Hyeong, Kiseong;Kim, Mun Gi;Ra, Kongtae;Jeong, Hyeryeong;Lim, Hyoun Soo
    • Journal of the Korean earth science society
    • /
    • v.42 no.1
    • /
    • pp.1-10
    • /
    • 2021
  • Silicon (Si) is the second most abundant element in the crust and consists of three stable isotopes, 28Si (92.23%), 29Si (4.67%), and 30Si (3.10%). Si isotopes are widely studied worldwide as a proxy for the biogeochemical cycle of Si to reconstruct the paleoenvironment and paleoclimate. However, in Korea, there have been no studies on biogenic silica using Si isotopes. In this study, we carried out Si isotope measurements of giant diatoms, summarizing the previously reported alkali fusion methods and establishing the best Si separation method for biogenic silica. Samples were completely digested using alkali fusion at high temperatures, effectively separating Si using an AG® 50W-X8 cation exchange resin. To evaluate the precision and accuracy of our measurements, Si isotope standard material (NBS-28) and USGS reference materials (AGV-2, GSP-2, BHVO-2) were analyzed. The results are in excellent agreement with the reported values within the acceptable error. The Si isotope measurement method developed in this study is expected to help in understanding the paleoclimate and paleoenvironment by tracing the Si cycle.

Copper Isotope Measurements Using a Neptune MC-ICP-MS (다검출기 유도결합 플라즈마 질량분석기를 이용한 구리 동위원소 분석법)

  • Park, Sanghee;Ryu, Jong-Sik;Shin, Hyung Seon;Kil, Youngwoo;Jo, Yunsoo
    • Journal of the Mineralogical Society of Korea
    • /
    • v.29 no.4
    • /
    • pp.221-227
    • /
    • 2016
  • Copper is an essential transition metal involving in various biogeochemical processes. With the recent advances in analytical techniques and mass spectrometry, such as MC-ICP-MS, it is possible to measure Cu isotopes, which allows us to understand various biogeochemical processes in detail. Nonetheless, few studies have been performed in South Korea. In this study, we compared two purification methods previously reported using an anion exchange resin ($AG^{(R)}$ MP-1M), developed the best method in our lab environment, and then verified it by measuring Cu isotopic compositions in two USGS geological reference materials (BHVO-2 and BIR-1a). Although all matrix cations causing mass bias were effectively removed through both two methods with the yield of better than 95%, the method using the mixture of HCl and $H_2O_2$ only displays Cu isotopic compositions, in excellent agreement with reported values within the error. The method developed in this study is expected to be commonly applied to earth and environmental sciences.