• Title/Summary/Keyword: 원거리측정시스템

Search Result 97, Processing Time 0.024 seconds

Development of Gas Leak Detecting System Based on Quantum Technology (양자기술기반 가스 누출 감지 시스템 개발)

  • Kwon, Oh Sung;Park, Min Young;Ban, Changwoo
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.5
    • /
    • pp.57-62
    • /
    • 2021
  • Gas is an energy source widely used in general households and industrial sites, and is also a process material widely used in petrochemical and semiconductor processes. However, while it is easy to use, it can cause large-scale human damage due to leakage, explosion, and human inhalation. Therefore, a gas facility safety management solution that can be safely used at home and industrial sites is essential. In particular, the need to develop advanced gas safety solutions is emerging as gas facilities are aging. In this paper, a technology was developed to measure the presence and concentration of gas leaks from a distance by irradiating photons, the minimum energy unit that can no longer be divided into gas facilities, and analyzing the number of reflected photons. This overcomes technical limitations such as short detection distance and inability to detect fine leaks, which are the limitations of conventional electric/chemical gas sensors or infrared-based gas leak detectors.

Analysis of the Driving & Loading Pattern of the Construction Waste Collecting Trucks Using IoT On-Board Truck Scale System (IoT 자중계 시스템을 활용한 건설폐기물 수집·운반 차량의 운행 및 적재패턴 분석)

  • Kim, Jong Woo;Jung, Young Woo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.19 no.6
    • /
    • pp.74-87
    • /
    • 2020
  • Overloaded trucks are the main source that threatens road safety and directly affects the reduction of pavement life. The On-board truck scale is the only equipment that could prevent overloading by measuring and adjusting the loading weight before driving. Legislation is needed to encourage its installation so that the driver can prevent overloading. In this study, an on-board truck scale system was installed on 30 dump trucks for transporting construction waste, such as soil and aggregates, which are major loads of 36.55% for overloading, and the trucks were monitored remotely. The overload prevention effect was analyzed by comparing driving data for 1 month before distribution of the weight display app that can recognize the weight to the driver and 1 month after distribution. After installation, overloading could be 6.1% reduced, and the transportation efficiency could be increased by checking the weight provided from the On-board truck scale system.

A Study of the Characteristics of Highly Spatially Resolved CW-laser-based Aerosol Lidar (고공간분해능 연속 광원을 이용한 미세먼지 라이다의 신호 특성에 관한 연구)

  • Sim, Juhyeon;Kim, Taekeong;Ju, Sohee;Noh, Youngmin;Kim, Dukhyeon
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.1
    • /
    • pp.1-10
    • /
    • 2022
  • In this study we introduce a new method for high-spatial-resolution continuous wave (CW) aerosol lidar that has a high spatial resolution in the near field and a low spatial resolution at long distances. A normal lidar system uses a nanosecond-pulse laser and measures the round-trip TOF between the aerosol and laser to obtain range resolution. In this study, however, we propose a new type of spatially resolving aerosol lidar that uses laser-scattering images. Using a laser-light-scattering image, we have calculated the distance of each scattering aerosol image for a given pixel, and recovered the short-range aerosol extinction. For this purpose, we have calculated the distance image and the contribution range of the aerosol to the given one-pixel image, and finally we have calculated the extinction coefficients of the aerosol with range-resolved information. In the case of traditional aerosol lidar, we can only obtain the aerosol extinction coefficients above 400 m. Using our suggested method, it was possible to extend the range of the extinction coefficient lower then several tens of meters. Finally, we can remove the unknown short-range region of pulsed aerosol lidar using our method.

Verification of Multi-point Displacement Response Measurement Algorithm Using Image Processing Technique (영상처리기법을 이용한 다중 변위응답 측정 알고리즘의 검증)

  • Kim, Sung-Wan;Kim, Nam-Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.3A
    • /
    • pp.297-307
    • /
    • 2010
  • Recently, maintenance engineering and technology for civil and building structures have begun to draw big attention and actually the number of structures that need to be evaluate on structural safety due to deterioration and performance degradation of structures are rapidly increasing. When stiffness is decreased because of deterioration of structures and member cracks, dynamic characteristics of structures would be changed. And it is important that the damaged areas and extent of the damage are correctly evaluated by analyzing dynamic characteristics from the actual behavior of a structure. In general, typical measurement instruments used for structure monitoring are dynamic instruments. Existing dynamic instruments are not easy to obtain reliable data when the cable connecting measurement sensors and device is long, and have uneconomical for 1 to 1 connection process between each sensor and instrument. Therefore, a method without attaching sensors to measure vibration at a long range is required. The representative applicable non-contact methods to measure the vibration of structures are laser doppler effect, a method using GPS, and image processing technique. The method using laser doppler effect shows relatively high accuracy but uneconomical while the method using GPS requires expensive equipment, and has its signal's own error and limited speed of sampling rate. But the method using image signal is simple and economical, and is proper to get vibration of inaccessible structures and dynamic characteristics. Image signals of camera instead of sensors had been recently used by many researchers. But the existing method, which records a point of a target attached on a structure and then measures vibration using image processing technique, could have relatively the limited objects of measurement. Therefore, this study conducted shaking table test and field load test to verify the validity of the method that can measure multi-point displacement responses of structures using image processing technique.

A Study On Design of ZigBee Chip Communication Module for Remote Radiation Measurement (원격 방사선 측정을 위한 ZigBee 원칩형 통신 모듈 설계에 대한 연구)

  • Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.18 no.4
    • /
    • pp.552-558
    • /
    • 2014
  • This paper suggests how to design a ZigBee-chip-based communication module to remotely measure radiation level. The suggested communication module consists of two control processors for the chip as generally required to configure a ZigBee system, and one chip module to configure a ZigBee RF device. The ZigBee-chip-based communication module for remote radiation measurement consists of a wireless communication controller; sensor and high-voltage generator; charger and power supply circuit; wired communication part; and RF circuit and antenna. The wireless communication controller is to control wireless communication for ZigBee and to measure radiation level remotely. The sensor and high-voltage generator generates 500 V in two consecutive series to amplify and filter pulses of radiation detected by G-M Tube. The charger and power supply circuit part is to charge lithium-ion battery and supply power to one-chip processors. The wired communication part serves as a RS-485/422 interface to enable USB interface and wired remote communication for interfacing with PC and debugging. RF circuit and antenna applies an RLC passive component for chip antenna to configure BALUN and antenna impedance matching circuit, allowing wireless communication. After configuring the ZigBee-chip-based communication module, tests were conducted to measure radiation level remotely: data were successfully transmitted in 10-meter and 100-meter distances, measuring radiation level in a remote condition. The communication module allows an environment where radiation level can be remotely measured in an economically beneficial way as it not only consumes less electricity but also costs less. By securing linearity of a radiation measuring device and by minimizing the device itself, it is possible to set up an environment where radiation can be measured in a reliable manner, and radiation level is monitored real-time.

3-Dimensional LADAR Optical Detector Development in Geiger Mode Operation (Geiger Mode로 동작하는 3차원 LADAR 광수신기 개발)

  • Choi, Soon-Gyu;Shin, Jung-Hwan;Kang, Sang-Gu;Hong, Jung-Ho;Kwon, Yong-Joon;Kang, Eung-Cheol;Lee, Chang-Jae
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.4
    • /
    • pp.176-183
    • /
    • 2013
  • In this paper, we report the design, fabrication and characterization of the 3-Dimensional optical receiver for a Laser Detection And Ranging (LADAR) system. The optical receiver is composed of three parts; $16{\pm}16$ Geiger Mode InGaAs Avalanche Photodiode (APD) array device operated at 1560 nm wavelength, Read Out Integrated Circuit (ROIC) measuring the Time-Of-Flight (TOF) of the return signal reflected from target objects, a package and cooler maintaining the proper operational condition of the detector and control electronics. We can confirm that the LADAR system can detect the signal from a target up to 1.2 km away, and it showed low Dark Count Rate (DCR) of less than 140 kHz, and higher than 28%-Photon Detection Efficiency (PDE). This is considered to be the best performance of the $16{\pm}16$ FPA APD optical receiver for a LADAR system.

Read Range Reduction in Passive UHF RFID Tag by Smart Device Signal Interference (스마트 기기 신호 간섭에 의한 수동형 UHF 대역 RFID 태그의 인식 거리 감소에 관한 연구)

  • Kwon, Jongwon;Song, Taeseung;Cho, Wonseo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.1
    • /
    • pp.83-91
    • /
    • 2014
  • The passive UHF RFID tags for item-level tagging are now explosively used in the supply chain and retail applications as they have several advantages, the two most relevant are cost and a longer read range. However, the signal interference problem between RFID tags and smart devices in real world is expected according to the smart-phone and tablet market growth together. The performance of RFID tags can be significantly less. The popular examples are the read-success rates and read range reduction. Especially, KT Corp. recently emphasized the serious signal interference at 900 MHz of LTE and old RFID frequencies through their public demonstration. By popular demands, this paper suggests the interference tolerance measurement method between the passive UHF RFID tag and the transmitted signal from a smart device. In addition, we selected three passive UHF RFID tags(Inlay) available on the market and quantitatively evaluated read range reduction results by interference signals using the PCR(Performance Change Rates) index. As a result, the LTE system is about three times as effective as the WCDMA system in terms of interference effects, and the read range performance of two RFID tags about 60 % drop.