• Title/Summary/Keyword: 운전 pH

Search Result 325, Processing Time 0.025 seconds

Phenol Removal by Ozone-Activated Carbon Hybrid Process (오존-활성탄 복합공정에 의한 페놀 제거)

  • Kim, Hwanik;Moon, Ji-Hoon;Chung, Jae Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.5
    • /
    • pp.311-316
    • /
    • 2014
  • Effects of operating parameters such as activated carbon dose and pH on the phenol oxidation in ozone-activated carbon hybrid process were investigated through a kinetic study. Activated carbon enhanced the self-decomposition of ozone, generating $OH{\cdot}$, thus promoting phenol degradation. The pseudo-first order rate constants of phenol degradation increased and half-life of phenol decreased with activated carbon dose. The increase of pH enhanced $OH{\cdot}$ generation through chain reactions initiated by $OH^-$, therefore increasing the phenol degradation rate. TOC removal efficiency increased about 3.2 times by adding activated carbon in ozonation process.

Evaluation of Operating Parameters of Reject Water Treatment System with Pilot-scale Biofilm Nitritation Plant at Field Condition (반류수처리를 위한 현장 pilot plant 생물막 아질산화 반응조에서 운전인자 평가)

  • Han, Jinhee;Kwon, Min;Han, Jonghun;Yun, Zuwhan;Nam, Haiuk;Ko, Joohyung
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.5
    • /
    • pp.636-641
    • /
    • 2007
  • A pilot-scale biofilm nitiritation reactor was operated with the reject water from a large wastewater treatment plant. The effects of various operating parameters including pH, temperature, dissolved oxygen, solids and organic concentrations were examined. A stable nitritation was achieved at operating pH range of 7.3 to 8.8 with an alkalinity addition. Higher operating temperature of $35{\pm}0.7^{\circ}C$ achieved more stable nitritation compared to $30{\pm}0.2^{\circ}C$. It has been noticed that nitrite accumulation maintained with DO, solids and organic concentrations range of 0.8 to 3.9 mg/L, 3,400 to 11,000 mg/L, and 86 to 572 mg/L, respectively. It seems that the accumulation of nitrite was caused by both the inhibition of $NO_2{^-}$ oxidizers due to free ammonia and the maintenance of the high operating temperature of $35^{\circ}C$ which promote to accumulate the $NH_4{^+}$ oxidizers in the reactor. According to microbial community analysis of fluorescence in situ hybridization and INT-Dehydrogenase measurements, more nitrifiers were presented in attached form compared to suspended growth.

Effects of Operating Parameters on Electrochemical Degradation of Rhodamine B and Formation of OH Radical Using BDD Electrode (BDD 전극을 이용한 OH 라디칼 생성과 염료 분해에 미치는 운전인자의 영향)

  • Park, Young-Seek;Kim, Dong-Seog
    • Journal of Environmental Science International
    • /
    • v.19 no.9
    • /
    • pp.1143-1152
    • /
    • 2010
  • The purpose of this study is to degradation of Rhodamine B (RhB, dye) and N, N-Dimethyl-4-nitrosoaniline (RNO, indicator of the electro-generation of OH radical) in solution using boron doped diamond (BDD) electrode. The effects of applied current (0.2~1.0 A), electrolyte type (NaCl, KCl, and $Na_2SO_4$) and electrolyte concentration (0.5~3.0 g/L), solution pH (3~11) and air flow rate (0~4 L/min) were evaluated. Experimental results showed that RhB and RNO removal tendencies appeared with the almost similar thing, except of current. Optimum current for RhB degradation was 0.6 A, however, RNO degradations was increased with increase of applied current. The RhB and RNO degradation of Cl type electrolyte were higher than that of the sulfate type. The RhB and RNO degradation were increased with increase of NaCl concentration and optimum NaCl dosage was 2.5 g/L. The RhB and RNO concentrations were not influenced by pH under pH 7. Optimum air flow rate for the oxidants generation and RhB and RNO degradation were 2 L/min. Initial removal rate of electrolysis process was expressed Langmuir - Hinshelwood equation, which is used to express the initial removal rate of UV/$TiO_$2 process.

Industrial Wastewater Treatment Containing High Concentration of Ammonia with Low Energy Micro-Bubble Reactor (저에너지 마이크로버블 장치를 이용한 고농도 암모니아 공장 폐수 처리)

  • Jung, Jae-Ouk;Jung, Yong-Jun
    • Journal of Wetlands Research
    • /
    • v.18 no.3
    • /
    • pp.286-291
    • /
    • 2016
  • This study was carried out to evaluate the feasibility of air-stripping by DIWS(Dip Injection Wet Scrubber) system on high concentration of ammonia wastewater more than 10,000 mg/L. In the case of changing temperature from $30^{\circ}C$ to $70^{\circ}C$ maintaining pH 12.5 within the 72 hours, the removal efficiency of T-N by the present treatment plant was increased to 90.5% which was initially kept 70.3%. Although the high concentration of T-N with 9,120~12,955 mg/L was treated by micro-bubble through DIWS system maintaining the temperature of $30^{\circ}C$ within the 20 hours, the removal efficiency of T-N reached 91.9%, which indicated the possibility of air-stripping.

Development of a Diagnosis Algorithm of Influent Loading Levels Using Pattern Matching Method in Sequencing Batch Reactor (SBR) (연속회분식반응기에서 패턴매칭방법을 이용한 유입수 부하수준 진단 알고리즘 개발)

  • Kim, Ye-Jin;Ahn, Yu-Ga;Kim, Hyo-Su;Shin, Jung-Phil;Kim, Chang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.2
    • /
    • pp.102-108
    • /
    • 2009
  • DO, ORP and pH values measured during SBR operation can provide information about removal reaction of organic contaminants and nutrient materials in the reactor. It is already generalized control strategy to control reaction phase time using their special patterns indicating the end of the removal reactions. However, those informations are limited to point out the end time of oxidative reaction in the aerobic phase or reductive reaction in the anoxic phase without giving quantitative value of influent loading level. In this research, a diagnosis algorithm which can estimate the loading level of carbon and ammonia as high, medium and low was developed using the basic measurements like DO, ORP, and pH. It will be possible to know the level of influent loading rate from those online measurements without experimental analysis.

The Study of Statistical Optimization of MTBE Removal by Photolysis(UV/H2O2) (광분해반응을 통한 MTBE 제거에 대한 통계적 최적화 연구)

  • Chun, Sukyoung;Chang, Soonwoong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.9
    • /
    • pp.55-61
    • /
    • 2011
  • This study investigate the use of ultraviolet(UV) light with hydrogen peroxide($H_2O_2$) for Methyl Tert Butyl Ether(MTBE) degradation in photolysis reactor. The process in general demands the generation of OH radicals in solution at the presence of UV light. These radicals can then attack the MTBE molecule and it is finally destroyed or converted into a simple harmless compound. The MTBE removal by photolysis were mathematically described as the independent variables such as irradiation intensity, initial concentration of MTBE and $H_2O_2$/MTBE ratio, and these were modeled by the use of response surface methodology(RSM). These experiments were carried out as a Box-Behnken Design(BBD) consisting of 15 experiments. Regression analysis term of Analysis of Variance(ANOVA) shows significantly p-value(p<0.05) and high coefficients for determination values($R^2$=94.60%) that allow satisfactory prediction of second-order regression model. And Canonical analysis yields the stationery point for response, with the estimate ridge of maximum responses and optimal conditions for Y(MTBE removal efficiency, %) are $x_1$=25.75 W of irradiation intensity, $x_2$=7.69 mg/L of MTBE concentration and $x_3$=11.04 of $H_2O_2$/MTBE molecular ratio, respectively. This study clearly shows that RSM is available tool for optimizing the operating conditions to maximize MTBE removal.

Development of a Vertical Multi-stage Ammonia Stripping Reactor for Recovering Ammonia from wastewater with High Nitrogen Concentrations(I) (고농도 질소폐수로부터 암모니아 회수를 위한 다단수직형 암모니아스트리핑조 개발(I))

  • Lee, Jae Myung;Choi, Hong-bok
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.25 no.2
    • /
    • pp.41-48
    • /
    • 2017
  • A vertical multi-stage ammonia stripping reactor using E-PFR, which has been proved to be superior in anaerobic and aerobic treatment, was developed and a lab scale experiment was conducted. According to the change of stage number condition, the removal rate of the ammonia nitrogen in the reactor with 0-stage was about 52.5% after 8 hours (pH 10, temperature $35^{\circ}C$, and the air/liquid ratio $3min^{-1}$) However, in the reactor with 5-stage, the removal efficiency was about 62.6%. According to the change of pH condition, the removal rate of ammonia nitrogen was about 42.6% at pH 9 after 8 hours, and was about 74.4% at pH 11 (5-stage reactor, temperature $35^{\circ}C$, and the air/liquid ratio $3min^{-1}$). According to the change of temperature condition, the removal rate of the ammonia nitrogen was about 51% at $25^{\circ}C$ after 8 hours (5-stage reactor, pH 10, and the air/liquid ratio $3min^{-1}$), and was about 87.2% at $45^{\circ}C$. According to the change of air injection volume condition, the removal rate of the ammonia nitrogen was about 45.8% at $2min^{-1}$ after 8 hours (5-stage reactor, pH 10, and at $35^{\circ}C$). and was about 75% at $4min^{-1}$. Based on these results, we will follow up the applicability of the actual plant in the future through continuous operation evaluation.

Estimation of Reliability of Real-time Control Parameters for Animal Wastewater Treatment Process and Establishment of an Index for Supplemental Carbon Source Addition (가축분뇨처리공정의 자동제어 인자 신뢰성 평가 및 적정 외부탄소원 공급량 지표 확립)

  • Pak, JaeIn;Ra, Jae In-
    • Journal of Animal Science and Technology
    • /
    • v.50 no.4
    • /
    • pp.561-572
    • /
    • 2008
  • Responses of real-time control parameters, such as ORP, DO and pH, to the conditions of biological animal wastewater treatment process were examined to evaluate the stability of real-time control using each parameter. Also an optimum index for supplemental carbon source addition based on NOx-N level was determined under a consideration of denitrification rate by endogenous respiration of microorganism and residual organic matter in liquor. Experiment was performed with lab-scale sequencing batch reactor(SBR) and working volume of the process was 45L. The distinctive nitrogen break point(NBP) on ORP-and DO-time profiles, which mean the termination of nitrification, started disappearing with the maintenance of low NH4-N loading rate. Also the NBP on ORP-and DO-time profiles was no longer observed when high NOx-N was loaded into the reactor, and the sensitivity of ORP became dull with the increase of NOx-N level. However, the distinctive NBP was constantly occurred on pH(mV)-time profile, maintaining unique profile patterns. This stable occurrence of NBP on pH(mV)-time profile was lasted even at very high NOx-N:NH4-N ratio(over 80:1) in reactor, and the specific point could be easily detected by tracking moving slope change(MSC) of the curve. Revelation of NBP on pH(mV)-time profile and recognition of the realtime control point using MSC were stable at a condition of over 300mg/L NOx-N level in reactor. The occurrence of distinctive NBP was persistent on pH(mV)-time profile even at a level of 10,000mg/L STOC(soluble total organic carbon) and the recognition of NBP was feasible by tracing MSC, but that point on ORP and DO-time profiles began to disappear with the increase of STOC level in reactor. The denitrfication rate by endogenous respiration and residual organic matter was about 0.4mg/L.hr., and it was found that 0.83 would be accepted as an index for supplemental carbon source addition when 0.1 of safety factor was applied.

Effect of Hydraulic Retention Time on Fermentative Hydrogen and Byproducts Production from Food Waste (음식물쓰레기 발효 시 수리학적 체류시간에 따른 수소 및 부산물 생성 특성)

  • Kim, Sang-Hyoun;Shin, Hang-Sik
    • KSBB Journal
    • /
    • v.20 no.6
    • /
    • pp.443-446
    • /
    • 2005
  • Hydrogen fermentation from food waste was attempted at different hydraulic retention time(HRT, 18-42 h). A continuous reactor fed with ground, alkali-treated and diluted food waste(average VS 4.4%) exhibited stable hydrogen production during 126 days. Hydrogen production depended on HRT, resulting in the maximum values of 25.8 mL $H_2/g\;VS_{added}$, 0.36 mol $H_2/mol\;hexose_{added}$ and 0.91 L $H_2/L/d$ at HRT 30 h. n-Butyrate and isopropanol production increased with hydrogen production increased, while acetate production decreased. The fermentation efficiency ranged from 53.3 to 65.7%, which implied that hydrogen fermentation would substitute conventional acidogenesis of food waste.

Development of Unitary 120kW PCS for Grid-Connected Photo-Voltaic Power Generation (단일용량 120kW급 계통연계형 태양광 발전용 PCS 개발)

  • Shin Y.C.;Moon J.S.;Ra B.H.;Kim Y.R.;Kim S.S.;Ahn K.S.;Lim H.C.
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.188-190
    • /
    • 2006
  • 본 논문에서는 국내최초로 개발에 성공한 단일용량의120kW급 계통연계형 태양광발전용 PCS에 관한 내용을 설명하고 있다. 120kW급 계통연계형 태양광발전시스템은 22.9kV의 특고압 계통전원에 연계되도록 설계되었으며, 삼상 380V를 22.9kV로 승압 연계하는 2단 절연방식을 채택하였다. 120kW급 PCS는 상용주파수 변압기 절연방식으로 3상4선식 380v 60H2 출력을 가지고 있으며, PCS 내부에 120kVA급 변압기와 리액터를 포함하고 있다. 최대출력점추종(MPPT)제어 기법으로 P&O 알고리즘을 적용하였으며, 3상 IGBT 인버터를 DSP로 제어하였다. 본 논문에서는 120kW급 단일용량 PC를 개발함에 있어, 계통연계 시험, 유,무효 전류제어 시험, 단독운전 검출 및 방지시험, 출력전류의 THD 측정 등의 결과를 보이고 있다.

  • PDF