• Title/Summary/Keyword: 운전 pH

Search Result 325, Processing Time 0.032 seconds

Analysis of the current status and implications of nitrogen recovery from livestock manure (가축분뇨로부터 질소 회수 연구 현황 및 시사점 분석)

  • Im, Seongwon;Kim, Sangmi;Kim, Jimin;Kim, Dong-Hoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.29 no.1
    • /
    • pp.37-46
    • /
    • 2021
  • Nitrogen and phosphorus in livestock manure are environmental pollutants, but also could be valuable industrial resources. In the present study, we (1) introduced various nitrogen removal technologies such as stripping, thermal method, membrane, and electrodialysis, (2) reviewed relevant studies reported in 2011-2020, in particular, full-scale experiences, and (3) assessed each technologies based on the above survey results. In addition, we provided the information on the appropriate range of the pH, temperature, gas and liquid ratio, and so on in ammonia stripping process, and expected mass balance when it is connected to biogasification process. We hope the content herein can be helpful for making policy and operating full-scale plant in Korea.

Solids and Nitrogen Removal in the Sludge Digestion using a Sequencing Batch Reactor (연속회분식반응조를 이용한 슬러지 소화에서 고형물과 질소의 제거)

  • Kim, Sung Hong;Lee, Yoon Heui
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.6B
    • /
    • pp.669-675
    • /
    • 2006
  • Intermittent aerobic digestion experiments using a sequencing batch reactor (SBR) were carried out in this study. Aeration ratio was found to be an important operation factor for the reduction of solids and nitrogen. As the sludge digested, organic nitrogen was released from the solids and oxidized to nitrate nitrogen. Biological denitrification was also significant and the denitrification rate was limited by aeration ratio. Under the condition of 0.25-0.75 of aeration ratio, acclimation of ammonia nitrogen was not observed and pH were preserved near neutral in the intermittent aerobic digestion. As the aeration ratio increased, solids reduction was increased whereas dissolved nitrogen removal was decreased. Based on the experiments, 17-2% of VSS reduction and over 80% of dissolved nitrogen removal were practicable by intermittent aerobic digestion using a SBR when the MSRT were designed 8-32 days and aeration ratio was operated about 0.25-0.75.

Design of Efficient Monitoring and Diagnosis System for Motor Condition Monitoring (모터의 상태 감시를 위한 효율적인 모터 감시 및 진단 시스템의 설계 및 구현)

  • Choi, J.H.;Park, H.S.;Lee, D.Z.;Eo, S.Y.;Kang, T.K.;Jeong, H.P.;Choi, J.P.
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.167-168
    • /
    • 2006
  • 본 논문은 현장에 운전 중인 모터를 효율적으로 고압 모터 감시 및 진단 기법을 검토하고 현장에 보다 적합한 고압모터 감시 및 진단 시스템을 설계 및 개발에 관하여 기술하였다. 고압 모터의 감시 및 진단 방법은 MCSA(Motor Current Signature Analysis) 기법을 기반으로 하여 순시전력, 공극토크, 진동분석 등 다양한 기법이 있으며 이 기법을 적용한 시스템이 출시되고 있다. 그러나 사용자의 요구 및 편이가 반영되지 않아 그대로 적용하기에는 어려움이 있다. 따라서 본 논문에서는 국내의 실정 및 사용자의 편이 맞도록 진단 시스템을 개발 필요성이 요구되어 다양한 검출 요소를 종합적으로 이용한 보다 현장에 적합하고 유용한 모터 감시 시스템을 설계하였다.

  • PDF

Characteristics of Ammonia Removal from a Synthetic Wastewater in a Jet Loop Reactor with a Two-fluid Venturi-type Swirl Nozzle (이유체 벤츄리형 선회 노즐이 장착된 제트 루프 반응기에서 합성폐수 중의 암모니아 제거특성)

  • Noh, Da-ji;Yun, Chan-Su;Lim, Jun-Heok;Won, Yong-Sun;Lee, Tae-Yoon;Lee, Jea-Keun
    • Clean Technology
    • /
    • v.23 no.2
    • /
    • pp.205-212
    • /
    • 2017
  • We investigated the performance of a jet loop reactor (JLR) with the two-fluid venturi-type swirl nozzle (TVSN) during experiment for ammonia removal by air stripping from a synthetic wastewater, and compared it with that of a JLR with the two-fluid venturi-type conventional nozzle (TVCN), with the variation of pH, liquid circulation rate ($Q_L$), and air flow rate ($Q_G$). Their performance levels were compared based on the ammonia removal efficiency and overall mass transfer coefficient ($K_La$). Investigated parameters in a JLR were pH (10-12), air flow rate ($Q_G=5-20L\;min^{-1}$), and liquid circulation rate ($Q_L=25-35L\;min^{-1}$). Throughout the experiment, the ammonia removal efficiency and $K_La$ in a JLR with TVSN was higher than in a JLR with TVCN. This may be due to the enhanced turbulent intensity by swirling flow formed in the JLR with TVSN compared to that with TVCN. Further, we obtained higher $K_La$ when pH, $Q_L$ and $Q_G$ were increased. In particular, $K_La$ was increased more efficiently by increasing $Q_G$ than by increasing pH and $Q_L$.

The Characteristics of Biopellet Produced Upon Reactor Configuration in UASB System (UASB 공법에 있어서 반응조의 형상변화에 따른 입상슬러지의 특성에 관한 연구)

  • Min, Kyung Sok;Ahn, Young Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.679-688
    • /
    • 1994
  • Physicochemical and morphological characteristics of biopellets produced in "control" and modified UASB reactor were investigated to compare the reactor performance with regard to the hydrogen partial pressure. The characteristics of biopellet produced in modified UASB reactor operated with high hydrogen partial pressure were better than those of "control" reactor operated with relatively lower hydrogen partial pressure, therefore the hydrogen partial pressure effected greatly on the formation and stability of the biopellet. Furthermore, pellets from the UASB system with modified settler showed a better settleability and biomass holding capacity. The chemical composition of biopellet was distinctively different from that of common bacterial formula, $C_5H_7O_2N$. Biopellets was composed the large fraction of nitrogen in comparison with common anaerobic microbes. These results implicated the existence possibility of polypeptide-type extracellular polymer. The morphological characterization with SEM showed that microorganisms observed at surface of biopellet produced in modified UASB reactor operated with high $P_{H_2}$ condition were very similar in shape and size to the Methanobrevibactor arboriphilus-$H_2$ utilizing methanogen. The microorganisms was distinguished from those of "control" reactor operated with low $P_{H_2}$ condition. From these results, it could be explained the hydrogen partial pressure effects on pelletization mechanism.

  • PDF

Effect of Operating Condition of Stripping Process on Ammonia Removal for Pre-treatment of Swine Wastewater (축산폐수 전처리를 위한 암모니아 탈기공정의 운전조건이 암모니아 제거에 미치는 영향)

  • Whang, Gye-Dae;Cho, Young-Moo
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.1
    • /
    • pp.86-92
    • /
    • 2004
  • Lab-scale experiments have been carried out to investigate ammonia stripping with a modified spray tower for removing ammonia nitrogen from swine wastewater. The operating conditions such as initial pH, temperature, air flow, hole size of distributor determining the diameter of water drops, and influent solids concentration were closely examined focusing on removal efficiency of ammonia. As a result of the experiment, in order to achieve high rate of ammonia removal by the air stripping system, the air flow rate must be supplied at high rate with sufficiently high initial pH, temperature. The optimum operating condition to meet the residual ammonia concentration of 300 mg/L was the initial pH of 11.0 at $35^{\circ}C$ with the air flow rate of 20 L/min. It also showed that the smaller hole size is, the higher removal rate of ammonia is expected. However, when used a small sized distributor (2 mm), the flooding problem at the upper column occurred due to clogging of the hole. With regard to the influent solids concentration, it was showed that the lower concentration of solids, the higher removal rate of ammonia. The removal of particulate materials in influent led to improve the removal efficiency of ammonia, rather than to control the operating condition including initial pH, temperature, and air flow. The empirical correlation between KLa and operating parameters would be driven as, $K_{La}=(0.0003T-0.0047){\cdot}G^{0.3926}{\cdot}L^{-0.5169}{\cdot}C^{-0. 1849}$. The calculated $K_{La}$ from proposed formula can be used effectively to estimate the optimum reaction time and to calculate the volume of modified spray tower system.

Removal Charateristics of Erythrosine by Activated Carbon Adsorption (활성탄 흡착에 의한 Erythrosine의 제거 특성)

  • Lee, Jong-Jib;Yoon, Sung-Wook
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.499-504
    • /
    • 2009
  • Erythrosine is used a food coloring, ink and dye, etc. but erithrosine is rarely used in United States due to its known hazards. The adsorption characteristics of erythrosine by granular activated carbon were investigated in the batch adsorber and the packed column. The adsorptivity of activated carbon for erythrosine were largely improved by pH control. When the pH was 11 in the sample, the erythrosine could be removed 98% of initial concentration. It was estabilished that the adsorption equilibrium of erythrosine on granular activated carbon was successfully fitted by Freundlich isotherm equation in the concentration range from 10mg/L to 1,000mg/L. The characteristics of breakthrough curve of activated carbon packed column depend on the design variables such as initial concentration, bed height, and flow rate.

Separation of Soybean Protein by Free-flow Electrophoresis (자유유동 전기이동법에 의한 대두단백질 분리)

  • 한재갑;류화원
    • KSBB Journal
    • /
    • v.10 no.1
    • /
    • pp.63-70
    • /
    • 1995
  • The effect of operating conditions on separation of soybean proteins in a home-made free-flow electrophoresis apparatus was investigated. Measurement of the pH, conductivity, and UV-absorbance(280 nm) were carried out at each run and the purity of the sample was tested with SDS-PAGE analysis. The soybean extract pretreated with Tris and boric acid was mixed with the amino acids composed of glutamic acid, histidine, arginine, glycine(1 mM each) with glycyl-glycine(2mM) and KCl(1mM). When the cellulose acetate was used as a compartment between the electrode and the buffer solution in the cell, pH distribution in the separation cell varied from 3.0 at the anodic side to 8.0 at the cathodic side and had two inflection point. The applied voltage was from 300V to 1000V and the separation was better at a higher voltage but the voltage was limited by the capability of the cooling system due to Joule heat. The proteins focused near the middle of the channel. From the change of pH and conductivity it was found that the ions in the channel moved out to the electrodes through the membrane. In the case when the concentration of the buffer solution was increased 5 times, proteins were focused at 300V. We could not increase up to the ten times of the concentration since the temperature difference between inlet and outlet was more than $25^{\circ}C$ and denaturation of proteins was expected. When ion-exchange membranes were used U-type pH distribution was set up due to the ionic polarization near the membrane. The commercial ampholytes, instead of the mixed amino acids showed not much improvements in purity of the separated sample.

  • PDF

Enhanced hydrogen fermentation of food waste (음식물쓰레기를 이용한 수소발효 시 효율향상에 관한 연구)

  • Han, Sun-Kee;Kim, Hyun-Woo;Shin, Hang-Sik
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.11 no.4
    • /
    • pp.105-113
    • /
    • 2003
  • Successful operation of a reactor can be accomplished when it is operated at proper D depending on the state of degradation. Operation at high D leads to the washout of biomass in the reactor while operation at low D leads to product inhibition due to the accumulation of excess VFA. These appear to limit the production of hydrogen to reach a higher level. Operation by D control was performed to improve the efficiency of hydrogen fermentation of food waste. Although simple organic matters were rapidly degraded in the early stage (day 1-2), proper VFA concentration and pH values were kept in the reactor at D of $4.5d^{-1}$, which was previously reported to be optimum initial D. High butyrate/acetate (B/A) ratios over 3.2 were obtained. Without D control, the reduction of simple organic matters after day 2 caused the decrease of VFA production and the increase of pH. Hydrogen production also decreased, as microbial proliferation was less than microbial loss by washout. However, the reactor performance was dramatically improved at D control from 4.5 to $2.3d^{-1}$. It showed the highest B/A ratios over 2.0 among the reactors on day 4-7. The second hydrogen peak appeared on day 4, resulting in the highest fermentation efficiency (70.8%) among the reactors. It was caused by the enhanced degradation of slowly degradable matters. The COD removed was converted to hydrogen (19.3%), VFA (36.5%), and ethanol (15.0%). Therefore, the strategy using D control, depending on the state of degradation, was effective in improving the efficiency of hydrogen fermentation.

  • PDF

Treatment Characteristics of Soil Clothing Contact Oxidation Process using Bio-media (생물담체를 충진한 토양피복 산화접촉공정의 하수처리특성)

  • Kim, Hong-Jae;Kang, Jae-Hee;Lee, Ki-Seok;Motoki, Kubo;Kang, Chang-Min;Chung, Seon-Yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.4
    • /
    • pp.414-419
    • /
    • 2005
  • This study was performed to compare the treatment efficiencies of two media, newly developed Bio-rock and conventional gravel, in soil clothing contact oxidation process. The composition of synthetic wastewater were $COD_{Cr}$ $150{\sim}370\;mg/L$, $BOD_5$ $150{\sim}270\;mg/L$, T-N $20{\sim}60\;mg/L$, T-P $5{\sim}25\;mg/L$, pH 7 and 2 mL/L of trace element solution. The experiment using two reactors was comparatively conducted for the flow rate of 40 L/d for 13 months, respectively. Initially Bio-rock reactor was increased to pH 12 due to $Ca(OH)_2$ with hydration of cement, but gravel reactor was dropped to pH 4 due to the degradation of organic material and nitrification. This significant pH variation deteriorated the growth and activity of microorganism. But the high pH of Bio-rock seems favorite to ammonia stripping and precipitation of phosphate. Such pH variation of Bio-rock and gravel reactors were finally stabilized to pH 8 and pH 6, respectively. The removal efficiencies of organic compounds from Bio-rock reactor were 96% of $COD_{Cr}$, 98% of $BOD_5$, 80% of T-N and 85% of T-P which stably coping against variation of influent concentration. But those of gravel reactor were 96% of $COD_{Cr}$, 96% of $BOD_5$, 42% of T-N and 40% of T-P, respectively. The Bio-rock was 2 times higher than T-N and T-P in treatment efficiency. And electron-microscopic examination showed that Bio-rock was more favorable to microbial adherence than gravel. The microbial populations were $5.2{\times}10^6\;CFU/mL$ of Bio-rock reactor compared to $2.6{\times}10^6\;CFU/mL$ in gravel reactor. In result Bio-rock was favor to microbial adherence and high treatment efficiency in spite of variation of influent concentration which had the advantages in saving running time and reducing site requirement.