• Title/Summary/Keyword: 운전 pH

Search Result 325, Processing Time 0.034 seconds

Operating Characteristics of 0.4 MW-Scale Gas Dispersion Type FGD Absorber (0.4 MW급 가스분사식 배연탈황 흡수탑의 운전 특성)

  • An, Hi-Soo;Kim, Ki-Hyoung;Park, Seung-Soo;Park, Kwang-Kyu;Kim, Young-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.4
    • /
    • pp.415-422
    • /
    • 2008
  • This study was carried out to investigate the effect of operating and design conditions of gas dispersion type of absorber on $SO_2$ removal efficiency. pH difference between upper and lower part of gas dispersing plate of absorber was 0.2, which was relatively low. This was supposed that recirculation capacity of absorbing liquid between froth zone and reaction zone of absorber be increased by oxidation air injection through liquid riser which acted as liquid pump. Test results showed that $SO_2$ removal efficiency was more sensitive than absorber ${\Delta}P$. High $SO_2$ removal even at lower pH resulted from very low concentration of $HSO_3^-$ ion in absorbing liquid because of direct supply of dissolved oxygen into froth zone. 96% of $SO_2$ removal efficiency was obtained under the condition of absorber pH 5.2, flue gas flow rate of $1,530\;Nm^3/hr$, inlet $SO_2$ concentration of 800 ppm, absorber ${\Delta}P$ of 250mmAq. The following equation by a multiple linear regression was obtained to describe the relationship between $SO_2$ removal and operating variables. $$f=1-{\exp}(-1.3939+1.060pH+0.0139{\Delta}P-0.00267G-0.000064SO_2Conc.),\;R^2=0.9719$$

UV/H2O2 Advanced Oxidation of Photo Processing Chemicals in a UV-free Reflecting Reactor (사진현상폐수의 UV-자유반사 반응조에서의 UV/H2O2 고급산화처리)

  • Choi, Kyung-Ae;Kim, Young-Ju
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.2
    • /
    • pp.241-249
    • /
    • 2000
  • In this study, UV-catalyzed $H_2O_2$ oxidation and $H_2O_2$ oxidation to remove contaminants from photo processing chemicals were investigated at various conditions. Photo processing chemicals contains high concentrations of organic compounds and has very low biodegradability. Hydrogen peroxide is subjected to gradual decomposition as metastable substance. In the process, short-lived and highly reactive hydroxyl radicals are formed. The decomposition can be significantly accelerated by use of appropriate catalyst, such as ultraviolet radiation. The experiments were conducted in a UV-free reflecting reactor in batch and a high-pressure mercury lamp was used as UV source. Mixing, cooling and ventilation of the reactor were operated during experiments. In $UV/H_2O_2$ oxidation and $H_2O_2$ oxidation, the removal efficiencies of $COD_{Cr}$, TOC and chromaticity increased with the increase of $H_2O_2$ dosage and were higher in the controlled pH condition of 3 than in original pH condition of 8. In $UV/H_2O_2$ oxidation under the optimum condition of pH 8 and 1.3 stoichiometric $H_2O_2$ dosage, the removal efficiencies of $COD_{Cr}$, TOC and chromaticity were 47.5%, 75.0% and 91.5% respectively and $BOD/COD_{Cr}$ ratio was significantly increased from 0.04 to 0.21.

  • PDF

A Study on Control Disinfection By-products in High Sodium Hypochlorite Generation (고농도 차아염소산나트륨 발생장치의 소독부산물 제어에 관한 연구)

  • Cho, Haejin;Shin, Hyunsoo;Ko, Sungho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.3
    • /
    • pp.183-189
    • /
    • 2017
  • Sodium hypochlorite used in water disinfection processes is generally in the production of chlorine to 0.8%. As the dose of chlorine increases, disinfection by-products (Chlorate) also increase simultaneously and exceed water quality standards. In this study, the electrolytic cell of a sodium hypochlorite generator (12% chlorine) was adjusted to control the production of the disinfection by-products. As a result, it was possible to reduce Chlorate concentrations by more than 95% by adjusting the pH of the electrolytic cell from 1.53 to 4.2 (normal pH of the electrolytic cell). As a low current is required to obtain these results, a 15% improvement in the efficiency of the positive electrode is also observed. For the development of High Sodium Hypochlorite Generation can be used in a safe sodium hypochlorite solution, which is expected to contribute to improvement in the safety of the disinfection process.

Effect of Current Density and pH of Electrolyte on Anion-Exchange Membrane Fouling (전류밀도와 전해질의 pH가 음이온교환막의 막 오염에 미치는 영향)

  • Choi, Jae-Hwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.9
    • /
    • pp.965-969
    • /
    • 2005
  • Current density is an important operating parameter in the ion-exchange membrane process. We observed the effects of fouling of a Neosepta AMX anion-exchange membrane(Tokuyama Soda, Japan) in 0.02 M NaCl solution containing 100 mg/L sodium humate. Membrane fouling was analyzed by measuring the change in the electrical resistance in the under- and over-limiting current density regions. The experimental results found that membrane fouling was negligible at under-limiting current densities, but was increased significantly when an over-limiting current was supplied. After the fouling experiments, the current-voltage curves for the fouled membranes were measured. From the curves, we observed increased electric resistance and reduced limiting current density(LCD), caused by the accumulation of humic acid on the membrane surface. Furthermore, membrane fouling increased as the acidity of the electrolyte solution containing humic acid increased. This occurred because the fouling of an anion-exchange membrane is affected more by the physicochemical properties of the humic substance than by the surface charge of the humate.

Phosphorus removal from dewatering centrate in wastewater treatment by struvite formation (스트루바이트 생성을 통한 하수슬러지 탈수여액 내 인 제거)

  • Kim, Sang-Hyoun;Park, Jong-Hun;Ju, Hyun-Jun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.21 no.2
    • /
    • pp.71-78
    • /
    • 2013
  • This study examined the feasibility of phosphorus removal from dewatering centrate/filtrate in wastewater treatment by struvite formation. Since dewatering centrate/filtrate obtained after anaerobic digestion contains a high content of ammonia, magesium addition and pH adjustment could remove phosphorous. The optimum magnesium dose, reaction time, settling time, and pH value was found at 2 mol Mg/mol $PO_4^{3-}$, 10 min, 120 min, and 8.5, respectively. A bench-scale continuous operation at the optimum condition showed 80% of total phosphorus removal and 82% of phosphate removal in dewatering centrate. The elemental composition and crystal structure of the chemical precipitate was similar to the reported values of struvite.

Recovery of Ammonia Nitrogen using Gas-permeable Membranes (기체투과막을 이용한 암모니아성 질소 회수방안)

  • Lee, Sang-hun;Chae, Sang Yeop
    • Membrane Journal
    • /
    • v.32 no.3
    • /
    • pp.191-197
    • /
    • 2022
  • Ammonia nitrogen can be effectively recovered from livestock manure waste, etc. by using the gas permeable membrane technology. In this case, ammonia gas in the waste passes through the pores in one-side of membrane, impregnated in waste, and then reach the opposite side of the membrane. The permeated ammonia gas molecules are captured and recovered by acid (such as sulfuric acid) in the solution existing on the opposite side of the membrane. In order to improve ammonia nitrogen removals in the inlet part, high pH should be maintained in the feed waste including ammonia nitrogen to recover, which requires the cost of the chemical. To resolve this issue, previous studies tested various methods, for example, utilization of cheap calcium hydroxide or aeration together with inhibition of unwanted nitrification. The gas permeable membranes used for the recovery of ammonia nitrogen may be characterized, not only by proper heat and chemical resistance, but also by hydrophobicity, allowing selective ammonia gas permeation through the hydrophobic membrane pores. Future research should consider the relevant pilot or upscale processes using on-site wastes with various properties, and identify the optimal design/operation conditions as well as economic feasibility improvement plans.

A Study on the Development Trends of Automobile-IT Convergence (국내외 자동차-IT 융합 추진동향)

  • Chun, H.W.;Heo, P.S.
    • Electronics and Telecommunications Trends
    • /
    • v.24 no.2
    • /
    • pp.9-18
    • /
    • 2009
  • 자동차-IT 융합은 첨단 IT 신기술을 기반으로 자동차의 센서 및 전자장치가 지능적, 유기적으로 상호 작용하여 운전자의 안전 및 편의성을 증대시켜 최적의 운전환경을 제공한다. 미래형 자동차 산업에 부가가치를 창출하는 산업으로, 안전과 편리성의 고도화를 중심으로 빠르게 확산되고 있다. 본 고에서는 국내외 자동차업체 및 IT 업체들의 추진동향을 중심으로 살펴보고 정책적 시사점을 도출하고자 한다.

Experiment and Simulation of 2-bed PSA for Hydrogen Separation from H2/CH4 Gas Mixture (수소/메탄 혼합 기체로부터 수소 분리를 위한 두 탑 PSA 실험과 전산 모사)

  • Nam, Gi-Moon;Jeong, Byung-Man;Kang, Seok-Hyun;Lee, Chang-Ha;Lee, Byung-Kwon;Choi, Dae-Ki
    • Korean Chemical Engineering Research
    • /
    • v.43 no.2
    • /
    • pp.249-258
    • /
    • 2005
  • A two-column six-step pressure swing adsorption(PSA) process was to study separation of hydrogen from hydrogen and methane($60_{vol}%/40_{vol}%$) binary system onto activated carbon adsorbent. The effects of the feed gas pressure, the feed flowrate and the P/F(purge to feed) ratio on the process performance were evaluated. The cyclic steady-states of PSA process were reached to after 15 cycles. $H_2$ purity increases according as the P/F ratio and pressure increase and the feed flow rate decreases; however, $H_2$ recovery shows an opposite phenomena to the purity. PSA process simulation studied to find optimum operation condition. In the results, 22 LPM feed flowrate, 11 atm adsorption pressure and 0.10 P/F ratio might be optimal values to obtain more than 75% recovery and 99% purity hydrogen. In this study was non-isothermal and non-adiabatic model considering linear driving force(LDF) model and Langmuir-Freundlich adsorption isotherm considered to compare between prediction and experimental data.

Operation of Sewage Sludge Composting Plant(Capacity of 1 ton/day) (1톤/일 처리규모의 하수슬러지 퇴비화 실증운전)

  • Joung, Kyong-Chul;Kwak, No-Hyuk;Park, Sung-Hee;Phae, Jae-Kuen
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.8 no.2
    • /
    • pp.77-84
    • /
    • 2000
  • Aim to get operation factors, an In-vessel Composting of Wastewater Sludge was operated. The composting equipment is consisted of three chamber, 1st, 2nd and 3rd consequently. In the results, the temperature of fermentation had shown that 1st fermentation chamber(F/C) temperature was higher than that of 2nd and 3rd fermentation chamber. The temperature was steady in all steps during the sludge being composted, the ranges of each step were $50^{\circ}{\sim}59^{\circ}C$ of 1st F/C, $41^{\circ}{\sim}50^{\circ}C$ of 2nd F/C, and $32^{\circ}{\sim}37^{\circ}C$ of 3rd F/C. Organic material content of the end product was 28% and that of pH was 7.5. Properties of the compost which have been composted on optimized condition, were shown that is acceptable to use as a fertilizer. Even in the winter time, the composting system was working well without any trouble. According to result of investigation, the end-product of the system was satisfied with the standard for a fertilizer usage. HRT(hydraulic retention time) of entire process was appropriated to be 14 days(0.9 days at drying and 3.5, 4.4, 5.2 days at each step of fermentations, respectively).

  • PDF

Influence of Operating Parameters on Nitrite Accumulation in a Biofilm Reactor and Supplement of External Carbon Source for Denitrification by Sewage Sludge Solubilization (생물막 반응조에서 아질산염 축적에 미치는 운전인자 영향과 하수슬러지 가용화에 의한 탈질반응의 외부탄소원 공급에 관한 연구)

  • Ahn, Hye Min;Lee, Dae Sung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.1
    • /
    • pp.57-63
    • /
    • 2013
  • A combined process consisted of a biofilm reactor and a continuously stirred-tank reactor (CSTR) was investigated for highly loaded ammonium wastewater treatment via nitrite accumulation. To enhance ammonium oxidizing bacteria over nitrite oxidizing bacteria on the surface of carriers, the biofilm reactor was operated at temperature of $35^{\circ}C$ for more than three months but the influent ammonium (500 mg-N/L) was partially oxidized to nitrite (240 mg-N/L). As pH was increased from 7.5 to 8.0, nitrite accumulation was fully achieved due to the inhibition of nitrite oxidizing bacteria under high free ammonia concentration. The biofilm reactor performance was severely deteriorated at the hydraulic retention time of 12 hr, at which incomplete nitrification of ammonia was observed. Various solubilization methods were applied to sewage sludge for enhancing its biodegradability and the combined method, alkaline followed by ultrasonic, gave the highest solubilization efficiency (58%); the solubilized solution was used as the external carbon source for denitrification reaction in CSTR. FISH analysis showed that the dominant microorganisms on the carriers were ammonium oxidizing bacteria such as Nitrosomonas spp. and Nitrospirar spp. but low amounts of nitrite oxidizing bacteria as Nitrobacter spp. was also detected.