• Title/Summary/Keyword: 운전 최적화

Search Result 442, Processing Time 0.032 seconds

Shoe Press 운전 최적화

  • 최병학;김도환;서동준;이민재
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2000.11a
    • /
    • pp.116-116
    • /
    • 2000
  • PDF

Optimization of Design Pressure Ratio of Positive Displacement Expander for Engine Waste Heat Recovery of Vehicle (자동차 엔진 폐열 회수 동력시스템에서 용적형 팽창기의 설계 팽창비 최적화)

  • Kim, Young Min;Shin, Dong Gil;Kim, Chang Gi;Woo, Se Jong;Choi, Byung Chul
    • Journal of Energy Engineering
    • /
    • v.21 no.4
    • /
    • pp.411-418
    • /
    • 2012
  • The effect of built-in volume ratio of expander on the performance of a two-loop Rankine cycle system for engine waste heat recovery of vehicle has been investigated. In the case of positive displacement expander in the various operating condition of the vehicle, it can operate in both under-expansion and over-expansion conditions. Therefore, the analysis of off-design performance for the expander is very important. Furthermore, the volume and weight of the expander as well as the efficiency must be considered in the optimization of the expander. This study shows that the built-in volume ratio of expander causing under-expansion at a target condition is more desirable considering the off-design performance and size of the expander, based on the simple modeling of off-design operation of the expander.

Development of Economic based Optimal Operation Program for Microgrid (경제성 기반의 마이크로그리드 최적운영 프로그램 개발)

  • Lee, Hak-Ju;Cha, Woo-Ku;Song, Il-Kun;Yoon, Yong-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.106-114
    • /
    • 2009
  • This paper addresses unit commitment for microgrid optimization including renewable energy sources, working under deregulated power market. As microgrid supplies both heat and electricity for consumer, operational optimization must be done to meet their demand economically. So renewable energy sources are considered to be negative load, and batteries are used as the load flattening device to raise possibly operational function. In the state of solution, the program is developed to solve out the maximum profit of microgrid using dynamic programming method. Finally, its validity is verified through case study in isolation mode and interconnected mode. The S/W will be used to operate microgrid economically after the market of microgrid is formed.

Optimization of an Ozone-based Advanced Oxidation Process for the Simultaneous Removal of Particulate Matters and Nitrogen Oxides in a Semiconductor Fabrication Process (반도체 제조공정 미세먼지-질소산화물 동시 저감을 위한 오존 고속산화공정 최적화 연구)

  • Uhm, Sunghyun;Lee, Seung Jun;Ko, Eun Ha;Hong, Gi Hoon;Hwang, Sangyeon
    • Applied Chemistry for Engineering
    • /
    • v.32 no.6
    • /
    • pp.659-663
    • /
    • 2021
  • 10 m3/min (CMM) multi-pollutants abatement system was successfully developed by effectively integrating ozone oxidation, wet scrubbing, and wet electrostatic precipitation for the simultaneous removal of particulate matters (PMs) and NOx in a semiconductor fabrication process. The sophisticated control and optimization of operating parameters were conducted to maximize the destruction and removal efficiency of NOx. In particular, the stability test of a wet electrostatic precipitator was carried out in parallel for 30 days to validate the reliability of core parts including a power supply. An O3/NO ratio, which is the most important operating parameter, was optimized to be about 1.5 and the optimization of wet scrubbing with a reducing agent made it possible to analyze the contribution of neutralization reaction.

Characteristics of 5 kW Class Proton-Exchange-Membrane Fuel Cell(PEMFC) Stack according to the Long-Term Operation (장기운전에 따른 5 kW급 고분자 전해질 연료전지 스택의 특성)

  • Kim, Jae-Dong;Lee, Jung-Woon;Park, Dal-Ryung
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.3
    • /
    • pp.40-43
    • /
    • 2007
  • The performance of PEMFC stack can be improved significantly by optimizing the design and operating conditions. As a result, the performance of daily operation showed slight deviation (0.02-0.9%) after accumulated DSS operation for 500 hrs but the stack performance was stable. Therefore, it is confirmed that it would be improved the life-time of stack and operation reliability for the commercialization of PEMFC system.

  • PDF

Power Control of a Hoist System Using Supercapacitor (수퍼캐패시터를 이용한 권상부하 시스템의 전력 제어)

  • Kim, Sang-Min;Sul, Seung-Ki;Yoo, Hyun-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1486-1488
    • /
    • 2005
  • 본 논문에서는 수퍼캐패시터(Supercapacitor 이하 수퍼�L)를 이용하여 엔진 발전기를 전원으로 하는 권상부하 시스템의 부하전력 분배와 회생에너지의 저장 기법을 제안한다. 대표적인 권상부하 시스템인 크레인의 경우, 크게 두가지 운전모드로 동작한다. 첫번째 운전모드는 부하를 들어올리는 동작(Hoist-Up)으로서 가속 종료시점에서 최대전력을 소모한다. 두번째 운전모드는 부하를 내리는 동작(Hoist-Down)으로서 이때 희생되는 전력은 일반적으로 저항을 통하여 소모된다. 본 논문에서는 에너지 저장장치의 하나인 수퍼�L을 이용하여 Hoist-Down 운전에서 희생되는 에너지를 저장하고 Hoist-Up 운전에서 필요한 전력을 보조하도록 하였다. 수퍼�L의 충방전을 위하여 상용 3상 인버터와 동일한 구조를 가지는 DC-DC 컨버터를 제안하였다. 또한 발전기와 수퍼캐패시터의 Load Sharing을 최적화하기 위한 알고리즘을 제안하였다. 제안한 방법을 이용하면 디젤엔진 발전기의 크기를 대폭 줄일 수 있고 따라서 연비의 개선, 소음 및 공해의 감소를 기대할 수 있다. 제안한 방법의 타당성을 검증하기 위하여 시뮬레이션과 실험을 수행하였다.

  • PDF

Design of a Wastewater Treatment Plant Upgrading to Advanced Nutrient Removal Treatment Using Modeling Methodology and Multivariate Statistical Analysis for Process Optimization (하수처리장의 고도처리 upgrading 설계와 공정 최적화를 위한 다변량 통계분석)

  • Kim, MinJeong;Kim, MinHan;Kim, YongSu;Yoo, ChangKyoo
    • Korean Chemical Engineering Research
    • /
    • v.48 no.5
    • /
    • pp.589-597
    • /
    • 2010
  • Strengthening the regulation standard of biological nutrient in wastewater treatment plant(WWTP), the necessity of repair of WWTP which is operated in conventional activated sludge process to advanced nutrient removal treatment is increased. However, in full-scale wastewater treatment system, it is not easy to fine the optimized operational condition of the advanced nutrient removal treatment through experiment due to the complex response of various influent conditions and operational conditions. Therefore, in this study, an upgrading design of conventional activated sludge process to advanced nutrient removal process using the modeling and simulation method based on activated sludge model(ASMs) is executed. And a design optimization of advanced treatment process using the response surface method(RSM) is carried out for statistical and systematic approach. In addition, for the operational optimization of full-scale WWTP, a correct analysis about kinetic variables of wastewater treatment is necessary. In this study, through partial least square(PLS) analysis which is one of the multivariable statistical analysis methods, a correlation between the kinetic variables of wastewater treatment system is comprehended, and the most effective variables to the advanced treatment operation result is deducted. Through this study, the methodology for upgrading design and operational optimization of advanced treatment process is provided, and an efficient repair of WWTP to advanced treatment can be expected reducing the design time and costs.

Case Study on Optimization of Send-out Operation in Liquefied Natural Gas Receiving Terminal (LNG 터미널 송출 운전 최적화 사례 연구)

  • Park, Chansaem;Han, Chonghun
    • Korean Chemical Engineering Research
    • /
    • v.53 no.2
    • /
    • pp.150-155
    • /
    • 2015
  • Recently, LNG receiving terminals have been widely constructed and expanded for an increase in LNG demand. Selection of the storage tank for send-out and estimation of send-out flow rate have significant influence to process operation and economics. In this study, a send-out flow rate of each storage tank is optimized in order to minimize the total BOG generation rate. Considering a size and characteristic of each storage tanks, BOG flow rates are estimated using a dynamic simulation with varying liquid levels in the tanks. The regression model is developed fitting BOG flow rates and tank liquid levels, which are boil off rate model to predict BOG flow rates with particular level data. The objective function and constraints including required total send-out flow rate and level limit in the tanks are formulated to optimize a send-out flow rate of each tank. This method for optimization of send-out operation is applied to the Incheon LNG receiving terminal considering two scenarios for various liquid levels and maximum and minimum required send-out flow rates. For maximum required send-out flow rate, this method achieves BOG reduction of 9% comparing with assumed conventional operation.

A study on the ventilation control method of road tunnel for small vehicles (소형차 전용 도로터널의 환기기 제어방안에 대한 연구)

  • Ryu, Ji-Oh;Lee, Hu-Young;Chang, Ji-Don
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.6
    • /
    • pp.749-762
    • /
    • 2019
  • In recent years, in urban areas, underground of roads are being promoted in order to resolve traffic congestion and to secure green spaces, and due to the low ratio of large vehicles, they are planned or constructed as road tunnels for small cars only. In addition, the tunnels being built in the city is a tendency to be enlarged to play the role of main roads. Accordingly, the capacity of the ventilation system is increasing and various ventilation methods are required, and the importance of maintenance after the completion of the tunnel such as the operating cost of the ventilation system is emphasized. Therefore, the need for optimization of the operation stage for reducing the power consumption of the ventilation system and the study of the ventilation system operation control logic is increasing. In this study, the study on the necessity of the optimization of operation stage and control logic of the ventilation system was carried out to realize the energy-saving operation for the small car only passing through tunnels which is applied of ① jet fan and combination ventilation system (② jet fan + air purifying equipment, ③ jet fan + vertical shaft, ④ jet fan + supply air semi-transverse). As a result of this study, there can be various operating combinations in the case of the combined ventilation system, and even though the amount of ventilation air is the same, the operating power varies greatly according to the operating combinations. It was found that operating the axial fan first rather than the jet fan first operation method has an effect on power saving.

Development of MBOP for 125 kW Molten Carbonate Fuel Cell (125kW급 용융탄산염 연료전지 MBOP 개발 및 성능평가결과)

  • Kang, Seung Won;Lee, Junghyun;Kim, Beumju;Kim, Do-Hyung;Kim, Eui-Hwan;Lim, Hee Chun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.130.2-130.2
    • /
    • 2010
  • 한전 전력연구원에서는 2009년 12월부터 125 kW급 용융탄산염 연료전지 발전시스템의 성능평가를 위한 운전이 진행되고 있다. 현재 진행 중인 "250 kW급 열병합 용융탄산염 연료전지 Proto Type개발" 과제의 최종시작품인 250 kW급 발전시스템은 125 kW급 MCFC 스택 2기로 설계되어, 125 kW급 시스템의 시험운전은 매우 중요한 기술적 성과가 될 것이다. 현재 125 kW급 MCFC 스택은 10,000 $cm^2$의 유효전극면적을 갖는 단위전지들로 구성되었으며, 적층 스택의 온도 및 농도분포의 최적화를 위해 내부 매니폴드 및 Co-flow Type 열교환기 기반의 분리판을 개발 적용하였다. 연료극의 전극 구성은 Ni-Al alloy로, 공기극의 전극 구성은 Lithiated-NiO로 이루어졌다. 그리고 매트릭스는 ${\alpha}-LiAlO_2$로 제작되었고, 전해질은 Li과 K Carbonate가 68 : 32 비율로 섞인 용융염을 사용하였다. 본 125 kW급 용융탄산염 연료전지 시스템의 운전평가는 고적층 스택의 온도 및 농도 분포를 확인하고, 최적화된 스택 운전 조건을 도출하는 것을 그 목적으로 하고 있다. 125kW급 스택 1기의 규모의 주변기기 시스템은 외부개질기, 촉매연소기, 이젝터, 고온순환 블로어 및 공기블로어 등으로 이루어져 있다. 고온형 연료전지 시스템에서 연료극과 공기극의 균일한 온도 및 압력 확보는 매우 중요하며, 이를 위하여 외부개질기 및 촉매연소기 연동을 통한 온도편차를 최소화하고, 기존 고온용 순환 블로어 대신 이젝터를 개발 도입하여 압력균형을 조절하였다. 125kW급 MCFC 시스템은 2009년 12월부터 전처리 운전을 시작하여 2010년 1월 말부터 PCS로 전기를 생산하고 있다. 평균전압 0.83V에서 100kW의 출력을 기록하였으며, 피크부하 120 kW, 누적출력량 30 MWh를 초과달성하였다.

  • PDF