• Title/Summary/Keyword: 운전제어

Search Result 2,046, Processing Time 0.031 seconds

A Study on the Rupture Disk Design and Application at the Two Phase Flow by Runaway Reaction at Batch Reactor (회분식 반응기에서 반응폭주에 의한 2-Phase 흐름 파열판 설계 및 적용에 관한 연구)

  • Lee, Hyung-Sub;Yun, Hee-Chang
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.3
    • /
    • pp.1-8
    • /
    • 2017
  • The purpose of this study is to suggest the rupture disk design(size) and application at the two phase(gas-liquid) flow by runaway reaction at batch reactor. The definition of runaway reaction is abnormally exothermic reaction by the uncontrolled cooling water or deviated operating condition. As a result, the temperature of reactor is rapidly increasing. The causes of runaway reaction are either self-heating reaction or sleeper reaction. General methods of rupture disk size or safety valve are not suitable in the runaway reaction, because of temperature and pressure increasing rapidly in the reactor and the phases of relieving fluid is 2-phase flow. This study case of the reactor incident, the depressurization system such as safety valve and vent installed, however, the system did not relieved the pressure of reactor suitably. The orifice size of the safety valve were designed too small because the size had not been considered the phenomena and character of reaction. The batch reactor design should be considered by referring to the possibility of runaway reaction proposed in this study and the size of rupture disk design method considering 2-phase flow.

고속파 전자가열을 시도한 KSTAR 토카막 원형 플라즈마에서의 ICRF 고주파 부하 저항

  • Wang, Seon-Jeong;Kim, Seon-Ho;Gwak, Jong-Gu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.297-297
    • /
    • 2010
  • KSTAR 토카막의 두번째 실험 캠페인 동안 고속파 전자가열 (FWEH)을 위한 ICRF 고주파입사 실험을 실시하였다. 토로이달 자기장은 2 T, 플라즈마 전류는 200-300 kA, 주반경은 1.8 m, 부반경은 0.5 m의 원형 플라즈마가 가열 대상이 되었으며, 네개의 ICRF 안테나 전류띠 가운데 중심부의 두개의 전류띠를 최대 300 kW로 구동하기 위한 운전 주파수는 44.2 MHz가 선택 되었다. 이 주파수는 플라즈마의 모든 영역에서 이온 사이클로트론 공명을 일으키지 않으므로 플라즈마에 흡수되는 대부분의 출력은 전자에게 전달될 것으로 기대되었다. 낮은 고주파-플라즈마 결합으로 인하여 전송선의 최대 고주파 전압이 허용치를 초과하기 때문에 비교적 낮은 최대 출력만이 허용 되었으나, ECE에 의해 관측된 전자의 온도는 국지적으로 최대 150 % 까지 증가하는 것을 확인 할 수 있었다. 낮은 고주파-플라즈마 결합의 첫번째 원인은 FWEH의 효율이 이온을 가열할 때 보다 상대적으로 낮기 때문이다. 플라즈마 내에 이온 사이클로트론 공명층이 형성되면 높은 효율로 고주파를 입사 할 수 있다는 것은 잘 알려진 사실이다. 또다른 원인은 D 형상의 플라즈마에 맞도록 만들어진 안테나와, 원형 플라즈마간의 부조화로 인하여 고속파 차단층이 (Fast Wave Cutt-off Layer) 평균적으로 넓게 형성되기 때문이다. 플라즈마 외곽에 반드시 존재하는 낮은 플라즈마 밀도의 고속파 차단층 내부에서, 중심부로 향하는 고주파의 진폭은 지수함수로 감쇠하므로 가능하면 플라즈마 밀도를 높여 차단층 자체의 폭을 줄이거나, 안테나 전류띠를 플라즈마에 바짝 접근시켜야만 한다. 고주파 진단 장치로는 송출기의 출력과 반사파 측정 장치, 공명루프의 전압 측정 장치가 있는데, 이것들을 이용하여 안테나에 전달되는 출력 및 고주파-플라즈마 결합 효율을 나타내는 플라즈마에 대한 고주파 부하 저항을 구할 수 있다. 측정 결과, 부하 저항의 최소값은 진공시 또는 ICRF만의 방전시의 값 0.25 Ohm 보다 큰 0.5 Ohm을 나타냈으며, 최대값은 플라즈마의 상태에 따라 1 Ohm에서 2 Ohm 사이에서 매우 빠르게 요동하는 것을 확인했다. Mm 파 반사계의 측정에 의하면 플라즈마 언저리의 위치가 약 3 cm 정도의 크기로 요동하는 것으로 나타났는데, 부하 저항과 언저리 위치의 파형이 정확하게 일치하지 않지만 유사한 경향성을 가진 것으로 보인다. 따라서 플라즈마 언저리 위치의 제어를 통하여 가열 효율을 높게 유지할 수 있음을 알 수 있다. 본 발표에서는 실험의 소개와 함께 부하 저항의 관점에서 가열 효율을 높일 방안을 토론하도록 한다.

  • PDF

Shaking Table Experimental Study on 3-Dimensional Floor Isolation in Main Control Room of Nuclear Power Plant (원전 주제어실 3차원 층 지진격리시스템의 진동대 실험 연구)

  • Lee, Kyung-Jin;Ham, Kyung-Won;Suh, Yong-Pyo;Yoon, Hyun-Do
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.1
    • /
    • pp.57-66
    • /
    • 2008
  • An experimental study was performed to evaluate seismic reduction performance and applicability of 3-dimensional floor isolation system to the main control room of nuclear power plant. A friction pendulum system(FPS) and air spring were designed and fabricated for 3-dimensional floor isolation system. Two kind of the partial experimental model of a main control room attached to the FPS and air spring were tested on the shaking table. The experimental model consisted of a control panel, a $2.5m{\times}2.5m$ access floor, four FPS and air springs. The artificial time histories based on the vertical and horizontal floor response spectrums(OBE, SSE) of the main control room were used as the earthquake input signals in the test. Compared to non-isolated system, the seismic response of experimental models using 3-dimensional floor isolation system were shown considerable seismic reduction performance.

Analysis for Characteristics of Driver's Legibility Performance Using Portable Variable Message Sign (PVMS) (운전자 인적요인을 고려한 PVMS 메시지 판독특성 분석)

  • Song, Tai-Jin;Oh, Cheol;Kim, Tae-Hyung;Yeon, Ji-Yoon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.4
    • /
    • pp.25-35
    • /
    • 2008
  • Variable Message Sign(VMS) is one of the subsystem of Intelligent Transportation Systems (ITS), which is useful for providing real-time information on weather, traffic and highway conditions. However, there are various situations such as incidents/accidents, constructions, special events, etc., which would be occurred on segments, it is unable to control traffic with only the VMS. Thus, it is essential to use of PVMS(Portable Variable Message Signs), which can move to the location needed traffic control and provide more active traffic information than VMS. This study developed a legibility distance model for PVMS messages using in-vehicle Differential Global Positioning Data(DGPS). Traffic conditions, drivers' characteristics, weather conditions and characteristics of PVMS message were investigated for establishing the legibility model based on multiple linear regression analysis. The factors such as height of PVMS characters, spot speed, age, gender and day and night were identified as dominants affecting the variation of legibility distances. It is expected that the proposed model would play a significant role in designing PVMS messages for providing more effective real-time traffic information.

  • PDF

A Robotcar-based Proof of Concept Model System for Dilemma Zone Decision Support Service (딜레마구간 의사결정 지원 서비스를 위한 로봇카 기반의 개념검증 모형 시스템)

  • Lee, Hyukjoon;Chung, Young-Uk;Lee, Hyungkeun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.13 no.4
    • /
    • pp.57-62
    • /
    • 2014
  • Recently, research activities to develop services for providing safety information to the drivers in fast moving vehicles based on various wireless network technologies such as DSRC (Dedicated Short Range Communication), IEEE 802.11p WAVE (Wireless Access for Vehicular Environment) are widely being carried out. This paper presents a proof-of-concept model based on a robot-car for Dilemma Zone Decision Assistant Service using the wireless LAN technology. The proposed model system consists of a robot-car based on an embedded Linux OS equipped with a WiFi interface and an on-board unit emulator, an Android-based remote controller to model a human driver interface, a laptop computer to run a model traffic signal controller and signal lights, and a WiFi access point to model a road-side unit.

Proposal of Youngjong-do 112 Block Demo-Plant for Application of Smart Water Grid (SWG 적용성을 위한 영종도 112블록 데모플랜트 구축 방안)

  • Han, Kuk Heon;Park, Hyun Ki;Kim, Young Hwa
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.108-108
    • /
    • 2016
  • 스마트워터그리드(Smart Water Grid; 이하 SWG)란 현재 직면에 있는 물 부족, 물 안보, 물 복지 등 물에 대한 문제를 ICT 기술을 활용하여 물관리의 새로운 패러다임을 제시할 수 있는 융합 기술이다. 즉, SWG는 기존의 수자원 관리 시스템의 한계를 극복하기 위해 첨단 정보통신기술을 이용하는 고효율의 차세대 인프라 시스템으로 다양한 수원을 활용하고 물을 효율적으로 배분 관리 운송하여 수자원의 불균형을 해소하고, 첨단센서네트워크를 이용해 용수관리 전분야에 걸쳐 양방향 실시간으로 용수정보를 감시 대응하여 용수관리와 에너지 효율의 최적화된 메가시티(mega-city)에 적합한 지능형 물관리가 가능할 것으로 예상되는 시스템이다. 따라서 국토교통부 과제로 추진중인 SWG 연구단에서 개발한 스마트 워터 기술을 영종도 112 블록에 적용하여 지역주민의 물복지 향상 및 물 사용자에 대한 소비자 만족도를 높이는데 목적을 두고 데모플랜트를 구축 방안을 수립하였다. 영종도 112블록(인천 운서동 및 운북동 일원)은 인천 공촌정수장에서 해저관로를 지나 영종통합 가압장에서 가압 후 공항신도시배수지에서 물을 공급받고 있는 지역으로 면적은 $17.41km^2$, 인구는 약 17,000명, 물사용량 $8,000m^3$/일, 총관로연장 약 55km, 유수율이 겨우 73.2% 지역이다. SWG 적용성 평가를 위해 영종도 112 블록에 유수율 제고 및 운영비용 저감을 목적으로 데모플랜트를 구축하였다. 스마트 계측을 위해 스마트미터 469개(15~20mm), 디지털미터 172개(25~200mm), 누수유무센서 1개소, 다항목 수질측정기 1개소, 유량계 3개소, 수압계 5개소, AMI 시스템 641개 및 물효율 운영프로그램과 물정보 App서비스 기능으로 구성하였다. 물효율 운영프로그램은 실시간 수요량 예측, 배수지 운영에 따른 취수량, 송수량, 펌프 대수조합 및 운전스케줄링이 가능한 경제적 물공급 스케줄링, 관망상태 감시 및 제어(실시간 유량/수압 분석을 통한 누수분석) 기능이 탑재되어 통합운영센터에서 운영할 계획이다. 데모플랜트 운영을 통해 수자원의 효율적인 배분 및 공급, 유지관리 향상, 운영 비용 최소화 등의 결과를 바탕으로 신도시 및 기존도시의 물관리 정책수립에 활용할 수 있을 뿐만아니라 시간적 공간적 불균형 해소 및 물시장 발전에 크게 기여할 것으로 사료된다.

  • PDF

Wireless image processing based management system the driver of the vehicle (무선 영상처리 기반의 차량 운전자 관리 시스템)

  • Seo, Ji-Hwan;Lee, Jae-Hyun;Kang, Sung-In;Shin, Dong-Suk;Kim, Kwan-Hyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.355-358
    • /
    • 2009
  • Due to growth of electronics and control devices, automation and situational awareness systems have been applied by automobile. Vision systems with the introduction of unmanned system being actively developed, but are still high price and visual information is passed through the cable, because of cars are difficult to install. In this paper, can be installed inside the car at low-cost, simple image processing device through a wireless communication know the obstacles and the alarm system based on Zigbee wireless communication, infrared and ultrasonic sensors to monitor the situation through with easy parking cars outside the system design was implemented.

  • PDF

The Study of Industrial Trends in Automotive Sensors Industry (차량용 센서 산업분석 및 발전방안)

  • Heo, Pil-sun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.829-832
    • /
    • 2009
  • Recently, IT-centered convergence between different industries has undergone rapid expansion, accompanied by major advances in u-IT development and digital convergence. Notably, in the automotive-IT convergence sector, automotive sensors and electronic devices interact closely and intelligently with each other, thereby increasing driver safety and convenience and creating the optimal driving environment. This has led to the generation of value-added for the future-oriented automotive industry. Sensing technologies - which are used to monitor traffic situations and transmit correct information (or warnings) on the road traffic situation to car drivers, and to provide accurate information to road traffic controllers - represent both the birth of high-safety, intelligent automotive technologies and the key to automotive manufacturing. In view of these developments, this paper examines the characteristics and structure of the automotive sensor industry, and outlines the policy implications for the automotive sensor industry with regard to the development of the automotive-IT convergence industry.

  • PDF

A Study on Water Balance in Stationary Load Proton Exchange Membrane(PEM) Fuel Cell Power Generator (고정 부하를 갖는 PEM 연료전지 발전기에 있어서의 수분 평형에 관한 연구)

  • Bakhtiar, Agung;Oh, Hoo-Kyu;Yoon, Jung-In;Kim, Young-Bok;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.128-135
    • /
    • 2011
  • 일반적으로 PEM 연료전지에서는 수분 균형이 시스템의 효율에 결정적으로 영향을 미치기 때문에, 이에 대한 균형(balance)을 잡는 것이 매우 중요하다. 특히, 촉매 층에서 물이 넘치는 익수현상(flooding)이나 건조현상(drying)이 발생하게 되면 연료전지의 효율이 급격하게 저하하므로, 항상 수분의 균형이 잡히도록 시스템을 제어하는 것이 일반적이다. 이 때,수분의 익수현상이나 건조현상은 PEM 연료전지의 용량과 주위의 환경, 즉 온도와 습도에 많은 영향을 받게 된다. 금번 논문에서는 가정용 규모인 3kW급에서 10kW급까지의 PEM 연료전지를 설치하였을 때, 주위의 환경(온도와 습도)이 수분 이동에 어떠한 영향을 미치는 지를 시간에 따라서 시뮬레이션(simulation)한 결과를 보여주고 있다. 결과에서 유입공기의 온도가 $50^{\circ}C$ 이하일 경우, 고정부하가 5kW급 이하이면 대부분이 건조현상이 발생하였으나, 고정부하가 6kW급 이상이 되면 익수현상이 운전시간이 20분 이내에서 발생하였다. 또한 고정부하를 최고 10kW급까지 올린 경우, 유입공기의 온도가 $50^{\circ}C$까지는 익수현상이 발생하였으나 $60^{\circ}C$ 이상인 경우에는 거의 건조현상이 발생함을 알 수 있었다.

A Study on the Water Gas Shift Reaction of RPF Syngas (RPF(Refuse plastic fuel) 합성가스의 수성가스 전환 반응 연구)

  • Roh, Seon Ah
    • Resources Recycling
    • /
    • v.30 no.6
    • /
    • pp.12-18
    • /
    • 2021
  • The water-gas shift reaction is the subsequent step using steam for hydrogen enrichment and H2/CO ratio-controlled syngas from gasification. In this study, a water-gas shift reaction was performed using syngas from an RPF gasification system. The water-gas shift using a catalyst was performed in a laboratory-scale tube reactor with a high temperature shift (HTS) and a low temperature shift (LTS). The effects of the reaction temperature, steam/carbon ratio, and flow rate on H2 production and CO conversion were investigated. The operating temperature was 250-400℃ for the HTS system and 190-220℃ for the LTS system. Steam/carbon ratios were between 1.5 and 3.5, and the composition of reactant was CO : 40 vol%, H2 : 25 vol%, and CO2 : 25 vol%. The CO conversion and H2 production increased as the reaction temperature and steam/carbon ratio increased. The CO conversion and H2 production decreased as the flow rate increased due to reduced retention time in the catalyst bed.