• Title/Summary/Keyword: 운전제어

Search Result 2,046, Processing Time 0.027 seconds

A Study on the Test Method of Local Information Processing Device in Digital Substation Based on IEC 61850 (IEC 61850 기반 디지털변전소 현장정보처리장치 시험 방법에 관한 연구)

  • Kim, Nam-Dae;Kim, Woo-Jung;Lee, Nam-Ho;Kim, Seok-Kon;Jang, Byung-Tae
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.3
    • /
    • pp.253-257
    • /
    • 2020
  • The local information processing devices are devices that process information by converting voltage, current, and digital electric signals from legacy-type power facility into IEC 61850 based data. It acquires and processes the operation information of legacy-type power facility, performs control of power facility, and interlock function using internal logic. In particular, the time to convert data to process input and output information for a device is important because a number of protection relay input and output signals are handled by only one device. This paper introduces test methods and cases for measuring IEC 61850 communication function and input/output data conversion time of local information processing device.

A Study on the Possibility of Transforming to Digital Substations using IEC 61850 Field Information Processing Panel of Legacy Substation (기존 변전소의 IEC 61850 기반 현장정보처리반을 이용한 디지털변전소 전환 가능성 검토에 관한 연구)

  • Yuk, Sim-Bok;Lee, Sung-Hwan;Kim, Chong-il
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.2
    • /
    • pp.129-136
    • /
    • 2018
  • The IEC 61850 communication standard is used worldwide, and within the country the new substation is built as a digital substation based on IEC 61850 from 2013, after field tests and R&D from 2007. Research on the development of digital substation operating system has been conducted mainly in large domestic companies, so the IED power application equipment for LCP are developed. However, there is still a lack of research in the field of systems that can accommodate all the field devices used for legacy substation and new digital substation. In this paper, we developed the 48VDC input modules and the 125VDC output modules which can construct proposed field information processing modules to IEC 61850 based type, and verified the field applicability from the state monitoring and control operation tests by using IEC 61850 client authentication program and Wireshark.

Phase Current Variation of Bifilar-Wound Hybrid Stepping Motor by Lead Angle Control (Lead Angle 제어에 의한 복권형 하이브리드 스테핑 전동기의 상전류 변화에 관한 연구)

  • 우광준;이종언
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.1
    • /
    • pp.26-34
    • /
    • 1998
  • In this paper, we confirm that the instanteneous phase current of the bifilar-wound hybrid stepping motor is dependent of lead angle by the experimental results. The variation of phase current with lead angle gives informations about the rotor position at the moment when phase winding coil is excited. We show that the rotor position of the bifilar-wound hybrid stepping motor for the closed-loop drives can be detected by using the instantaneous phase current measurement. We propose an instantaneous phase current equation as the function of electrical lead angle by the modeling of the bifilar-wound hybrid stepping motor. We also analyze the relationship between instantaneous phase current and rotor position by the computer simulation results. By the experimental results, we also confirm that the information about the rotor position can be obtained from the instantaneous phase current values at the instance of $\pi/2$ electrical angle of excitation pulse. pulse.

  • PDF

System Development of a 100 kW Molten Carbonate Fuel Cell III (System Control and Operation Mode) (100 kW급 용융탄산염 연료전지 시스템 개발 III (시스템 제어 및 운전모드))

  • Lim, Hee-Chun;Ahn, Kyo-Sang;Seo, Hai-Kyung;Eom, Yeong-Chang
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1350-1352
    • /
    • 2003
  • For developing a 100 kW MCFC power generation system, Several design parameters for a fuel cell stack and system analysis results by Cycle Tempo, a processing computer soft ware, were described. Approximately two substacks with 90 cells are required to generate 100 kW at a current density of $125\;mA/cm^2$ with $6000\;cm^2$ of cells. An overall heat balance was calculated to predict exit temperature. The 100 kW power is expected only under pressurized operation condition at 3 atm. Recycle of cathode gas by more than 50% is recommended to run the stack at $125\;mA/cm^2$ and 3 atm. Manifolds should be designed based on gas flow rates for the suggested operating condition. The fuel cell power generation system was designed conceptually with several choices of utilization of anode exhaust gas. To operate and evaluate the MCFC system, control and measurement system and operation mode are designed before 100 MCFC system construction. In system control schematics, OS, PLC and MMI were consisted and have roles for MCFC system control. For operation of 100 kW MCFC system, NS, PS PR mode were considerated step by step and simulated.

  • PDF

Micromachined Multiple Gas Sensor for Automotive Ventilation and Air Conditioning Systems (미세기계가공된 자동차 HVAC 시스템용 다중 가스센서)

  • Choi, W.S.;Lee, S.H.;Kim, S.D.;Park, J.S.;Park, H.D.;Min, N.K.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1637-1638
    • /
    • 2006
  • HVAC 시스템은 쾌적하고 깨끗한 운전환경을 만들어 줌으로써 운전자에게 향상된 안락성과 안전성을 제공한다. 이때 센서는 시시각각으로 변화하는 차실 내외의 환경변화에 대한 정보를 검출하여 HVAC 제어 유니트에 제공한다. 현재 HVAC 시스템에 사용되고 있는 후막 가스센서는 소자 크기와 소비전력이 크고, 제작공정이 까다로워 생산성이 낮은 단점이 있다. 이와 같은 문제점을 해결하기 위해서 최근에는 초소형화, 저소비전력, 대량생산에 의한 저가격화가 가능한 MEMS 가스센서의 연구개발이 활발히 진행되고 있다. 본 연구에서는 MEMS 구조체를 이용한 마이크로 가스센서를 설계 및 제작하였고, 감도특성을 고찰하였다. 가스 감지막은 금속산화물 페이스트를 스크린 프린팅 하는 종래의 방법 대신 MEMS 구조체에 적용 가능한 sol-gel 프로세스에 의해 형성하였다. 또 가스 감지전극과 micro-heater를 동일 평면상에 제작, 공정을 간소화하여 저가화를 시도하였다. MEMS 구조체 위에 제작된 Pt 박막 micro-heater의 인가전압에 따른 발열특성을 조사한 결과, 발열온도가 인가전압에 비례하는 이상적인 선형성을 나타내었으며, $300^{\circ}C$의 동작 온도에 도달하기 위해 65mW 이하의 저전력 동작이 가능하였다. 가스 센서의 감도특성 확인 실험은 CO 가스 10ppm, NO 가스 0.3ppm을 기준으로 수행되었으며, CO 및 NO에 대해 Rs(sensitivity, 가스반응저항/초기저항) 값은 각각 0.753 과 2.416로 우수한 성능을 나타내었다.

  • PDF

Optimization Design of Commercial Large Gas Oven Systems (상업용 대형 가스오븐 시스템의 최적 설계)

  • Kim, Do-Hyun;Yu, Byeonghun;Kum, Sungmin;Lee, Chang-Eon
    • Journal of Energy Engineering
    • /
    • v.25 no.2
    • /
    • pp.21-28
    • /
    • 2016
  • This research was conducted for the optimal design of large commercial gas oven system. Equivalent ratio was determined through a numerical analysis and experiments on the combustion condition of the combustor. After reviewing the supply capacity of burner(20,000 kcal) and control method of convection fan, two types of heat exchangers designed. In order to maintain a uniform temperature inside the oven is required convection fan braking system. The center temperature in the oven rises more rapidly when the convectional fan is rotated in the counterclockwise direction than the counter-clockwise direction. And The efficiency of the system by installing a large heat transfer area was higher.

A Study on the Application with Limestone Sludge at Limestone-Gypsum Wet Flue Gas Desulfurization Process (석회석 슬러지의 석회석-석고 습식 배연탈황 공정적용에 관한 연구)

  • Seo, Sung Kwan;Chu, Yong Sik;Shim, Kwang Bo
    • Resources Recycling
    • /
    • v.25 no.5
    • /
    • pp.44-49
    • /
    • 2016
  • Flue gas desulfurization(FGD) is an effective technique to remove $SO_2$ gases of coal-fired plants. Limestone is usually used as desulfurizing agent. In this study, we use the limestone sludge which is a by-product of steel industry in order to replace desulfurizing agent of FGD process. Physical and chemical characteristics analysis of desulfurizing agent was conducted. Desulfurizing agent using limestone sludge was fabricated by pre-treatment process and, then the agent was used on FGD process. Consequently, the tendency on the $SO_2$ concentration did not appear. And limestone sludge was considered as possible alternative agent for flue gas desulfurization process through absorber control system.

The development and operation characteristics analysis of PCS applied PV Output Senseless (POS) MPPT (PV Output Senseless (POS) MPPT 제어법이 적용된 단상 PCS 개발 및 운전특성 분석)

  • Lee, Seok-Ju;Park, Hae-Yong;Kim, Gyeong-Hun;Seo, Hyo-Ryong;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.226-227
    • /
    • 2007
  • The purpose of this study for photovoltaic (PV) generation system is to keep the output power of photovoltaic cells maximized under any weather conditions. In a conventional MPPT (Maximum Power Point Tracking) control method, both voltage and current coming out from PV array have to be fedback. Thus, the system has a complex structure, and may fail to track MPP of PV array when unexpected weather conditions happen. This paper proposes a novel PV Output Senseless (POS) control method to solve the mentioned problem. The main advantage of this method is that the current flowing into load is the only one considerable factor. In case of a huge PV generation system, it can be operated much more safely than the conventional system. To verify this theory, results that compare and analyze the simulated data with experimental data under real weather condition of the manufactured PV generation system are shown in this paper. Authors vividly states that this theory uses constant resistors and variable resistors of DC-DC converter in PV system. Authors emphasize that it is a very useful method to maximize power from PV cells to load with only the feedback of load current. Authors also emphasize that this theory is applicable in case of the PCS in PV power generation system.

  • PDF

A Study on Distance Relay of Transmission UPFC Using Artificial Neural Network (신경회로망을 이용한 UPFC가 연계된 송전선로의 거리계전기에 관한 연구)

  • Lee, Jun-Kyong;Park, Jeong-Ho;Lee, Seung-Hyuk;Kim, Jin-O
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.37-44
    • /
    • 2004
  • This paper represents a new approach for the protective relay of power transmission lines using a Artificial Neural Network(ANN). A different fault m transmission lines need to be detected classified and located accurately and cleared as fast as possible. However, The protection range of the distance relay is always designed on the basis of fixed settings, and unfortunately these approach do not have the ability to adapt dynamically to the system operating condition. ANN is suitable for the adaptive relaying and the detection of complex faults. The backpropagation algerian based multi-layer protection is utilized for the teaming process. It allows to make control to various protection functions. As expected, the simulation result demonstrate that this approach is useful and satisfactory.

An Efficient Real Time Processing Method for Frequently Updated Data (빈번한 변경이 요구되는 데이터의 효율적인 실시간 처리 기법)

  • Kim Jin-Deog;Jin Kyo-Hong;Lee Sung-Jin;Jung Hae-Won
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.461-465
    • /
    • 2006
  • Recently, the operator modules to control external devices are concerned about automatic management system to process continuously changed signals. They need a efficient data management with high reliability and real time processing. The characteristics of these data are a large volume, a short report interval and asynchronous report time. The typical queries of these systems consist of the current query to search the latest signal value, the snapshot query to search the signal value of a past time, the historical query to search the signal value of a past tine to current. In this paper, we propose the efficient method to manage the above signals by using a file structured database in QNX operating systems. The data communications among the devices are done by Profibus-FMS protocol and the file databases are used for adjusting monitoring frequency and storing signals. The file database adopts a delta version and a periodical back up in due consideration of the resource limit of a small storage and a low computing power in QNX COM(Cabinet Operator Module).

  • PDF