A Study on High Temperature Fracture Behavior of Plasma Sprayed Zirconia/ NiCrAlY Coating System (지르코니아 /NiCrAlY 계 플라즈마 용사피막의 고온 파괴거동에 관한 연구)

  • Kim, Yeon-Jik;Im, Jae-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.10
    • /
    • pp.3234-3242
    • /
    • 1996
  • This paper describes experimental results of modified small punch( MSP) test conducted to evaluate the fracure characteristics and mechanical properties of plasma sparayed zirconia ($ZrO_2$ stabilized with 8wt. % $Y_20_3$ : YSZ) NiCrAlY composite. The mixing ratios of YSZ/NiCrAlY were 0/100, 25/75, 50/50, 100/0 v.%. Test temperatures ranged from 293K to 1473K. This study is directed at development of thermal barrrier coating(TBC) system with superior heat resistance and mechanical properties. The microstructure and fracture process of the composite were examined by SEM and AE method. The mechanical properties of 100% YSZ were nearly independent of the temperatures tested in this study. In contrast, the NiCrAlY-containing composites showed a significant decrease of the mechanical properties above 1273K, showing a ductile- brittle transition behavior up to the temperature. Furthermore, it can seen that 25% YSZ/75% NiCrAlY composite gave the highest fracure strength and fracture energy among the mixing ratio tested over the temperature range.

An Experimental Study on the Development of Electromagnetic Shielding Concrete Wall for Shielding High-altitude Electromagnetic Pulse (HEMP) (고고도 전자기파(HEMP)차폐를 위한 전자파 차폐 콘크리트 벽체 개발에 관한 실험적 연구)

  • Choi, Hyun-Jun;Kim, Hyung-Chul;Lim, Sang-Woo;Lee, Han-Seung
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.2
    • /
    • pp.169-177
    • /
    • 2017
  • Rather than causing damage from heat, blast, and radiation of a regular nuclear weapon, recently, it is predicted that North Korea has been inventing high altitude electromagnetic pulse (HEMP) missile in order to incapacitate electronic equipment. HEMP shielding facility is used for military purpose today. Despite the electromagnetic shielding effects from high quality compression plates, problems may include such as the possibility of electromagnetic influx resulting in the welding of the compression plates, and difficulties and high cost of construction. Therefore, in this study, a high electrical conducting material was added to the concrete experimental subject to ensure the shielding effect through electromagnetic waves to for the concrete structure, instead of building a shielding facility separately for the structure. Also, among the experimental subjects, 100 ${\mu}m$ of Iron-Aluminum alloy metal spraying coat was applied to two types with the highest shielding effect, and to two types with the lowest shielding effect. The result of the experiment indicates that experimental subjects added with a high electrical conductivity material did not meet the minimum shielding criteria of MIL-STD-118-125-1 standard, but all the experimental material applied to the metal spraying coating satisfied the minimum shielding criteria. In conclusion, it is considered that 100 µm of Iron-Aluminum alloy metal spraying coat contains high efficiency in the HEMP shielding.

Effects of Metalized Al-2%Zn Layer on the Corrosion Behavior of Al 5083 Alloy (Al 5083 합금의 부식거동에 미치는 Al-2%Zn 용사 코팅층의 영향)

  • 김용철;김영근;이성민;고영태
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1999.05a
    • /
    • pp.2-2
    • /
    • 1999
  • 금속재료의 표면 특성을 높이기 위해서 여러 표면처리 방법들이 사용되어져 오고 있다. 그 중 용사법에 의한 코팅방법이 최근의 현저한 기술적인 진보와 새로운 용사재료의 개발 등에 의해 여러 분야에 널리 응흉되고 있다. 일반적으로 이 용사법에 의한 코팅층은 다리, 선박 등의 대형 구조물에 대한 내식성 향상뿐만 아니라 자동차 및 항공기 부품, 핵 반응기 등의 코팅부에 널리 이용되고 였다. 특히 해수분위기에서 주로 사용되는 설비의 내식성을 향상시킬 목적으로 사용되 는 알루마늄 및 아연 합금의 용사 코팅층은 대부분의 경우 건조한 분위기보다는 수분이 많은 수용액 환경 하에서 사용되므로, 사용 환경 중에서 용사피막의 내식성을 조사하는 연구가 요구되고 있다. 사용되는 환경하에서의 침지시험에 의한 방법도 중요하지만, 가속화된 전기화학측정에 의한 방법 또한 이용된다. 열용사법에 의한 코팅층의 전기화학적 특성을 알아보기 위해서 3.5 % NaCI 수용액 내에서 AI 5 5083 모재와 Al-2%Zn 합금의 용사 코팅층 각각에 대한, 그리고 AI 5083 모재 위 AI-2%Zn 용사층이 코팅된 경우에 대한 분극거동과 침지시간에 따른 부식전위 및 분극저항성의 특성변화, 표면의 임피던스특성 변화 등을 측정하였다. 이 결과 모재에 대한 코팅층의 희생양극성올 판단할 수 있고, 모재/코팅 사스템의 분극거동은 혼성전위이론(mixed-potential theory)에 의해 결정되었다. 용사 코팅층이 박리되어 모재가 일부 드러난 경우를 모사한 시험편올 제작하고, 시험편 표면의 각 위치에 따라 부식전위 분포를 측정하였다. 그리고 측정 데이터를 기초로 표면의 상태변화를 모사하여 용사코팅에 의한 표면에서의 방식전위분포를 시율레이션하였다. 이와 같은 표면에서의 방식전위분포 해석을 통하여, 코팅층의 희생양극성에 의한 모재의 방식범위를 판단할 수 있다.의 비저 항을 갖는 철 박막에서도 99.9% 순도의 철을 타켓으로 하여 증착된 막은 일반 저탄소 강을 타켓으로 하여 증착된 막보다 훨씬 낮은 부식속도를 보였다.TEX>$He/O_2/Ar/N_2$의 gas를 사용 한 atmospheric pressure plasma cleaning 과 $Ar/O_2$의 gas를 사용한 ICP cleaning에서 이 차전자방출계수(SEEC)가 약 1.5~2.5배 증가된 것을 알 수 있었다. 저지능 등을 평가하여 각 실험결과를 비교분석하여 보았다. 수록 민감하여 304 의 IGSCC 와 매우 유사한 거동을 보인다. 본 강연에서는 304 와 600 의 고온 물에서 일어나는 IGSCC 민감도에 미치는 환경, 예민화처리, 합금원소의 영향을 고찰하고 이에 대한 최근의 연구 동향과 방식 방법을 다룬다.다.의 목적과 지식)보다 미학적 경험에 주는 영향이 큰 것으로 나타났으며, 모든 사람들에게 비슷한 미학적 경험을 발생시키는 것 이 밝혀졌다. 다시 말하면 모든 사람들은 그들의 문화적인 국적과 사회적 인 직업의 차이, 목적의 차이, 또한 환경의 의미의 차이에 상관없이 아름다 운 경관(High-beauty landscape)을 주거지나 나들이 장소로서 선호했으며, 아름답다고 평가했다. 반면에, 사람들이 갖고 있는 문화의 차이, 직업의 차 이, 목적의 차이, 그리고 환경의 의미의 차이에 따라 경관의 미학적 평가가 달라진 것으로 나타났다.corner$적 의도에 의한 경관구성의 일면을 확인할수 있지만 엄밀히 생각하여 보면 이러한 예의 경우도 최락의 총체적인 외형은 마찬가지로 $\ulcorner$순응$\lrcorner$의 범위를 벗어나지 않는다. 그렇기 때문에도 $\ulcorner$순응$\lrcorne

  • PDF

A Study on the Optimum Conditions in Stainless Steel Arc Spraying (스테인레스강 아이크 용사에 있어서의 최적 용사조건에 관한 연구)

  • 김영식;최영국
    • Journal of Welding and Joining
    • /
    • v.4 no.3
    • /
    • pp.50-57
    • /
    • 1986
  • In this study, the experiments were earried out for the purpose of the clarifying the optimum metal arc spraying conditions, such as spraying distance, wire feed speed, arc current, etc, by using the stainless steel wire ER 308L. Main results obtained are as follows: 1. Optimum spraying distance is closely related to the equilibrium temperature of base material in back surface. 2. The size fused metal particles is increased according to the temperature of fused metal. 3. The maximum adhesion strength of coatings is obtained under the optimum spraying conditions of which the temperature of fundamental is maximum.

  • PDF

Tensile Analysis of Plasma Spray Coating Material by Classification of AE Signals (Acoustic Emission 파형분류에 의한 플라즈마 용사 코팅재의 인장해석)

  • ;;K. ONO
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.4
    • /
    • pp.60-65
    • /
    • 2001
  • Thermal spray coating is formed by a process in which melted particles flying with high speed towards substrate, then crash and spread on the substrate surface cooled and solidified in a very short time, Stacking of the particles makes coating. In this study, the exfoliation of $Al_2$O$_3$ and Ni-4.5wt.%Al thermally sprayed coating which were deposited by an atmospheric plasma spray apparatus are investigated using an AE method. A tensile test is conducted on notch specimens in a stress range below the elastic limit of substrate. The wave forms of AE generated from the three coating specimens can be classified by FFT analysis into two types which low frequency(type I waveform is considered to corresponds exfoliation of coating layers and type II waveform corresponds the plastic deformation of notch tip or the resultant fracture of coating. The fracture of the coating layers can estimate by AE event and amplitude, because AE features increase when the deformation generates.

  • PDF

An Experimental Study on the Corrosion Behavior in the Steel Meterial Embedded in Cement Mortar with Metal Spray Method (금속용사피막을 갖는 강재의 시멘트 모르타르 내 부식거동에 관한 실험적연구)

  • Park, Jang-Hyun;Kim, In-Soo;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.105-106
    • /
    • 2017
  • The metal spray method, one of the surface anti-corrosion methods to prevent the corrosion of the steel material, does little effects on the material, while it can be used on a wider surface. However, metal spraying is used only in a limited environment, and research on the case of using with concrete is lacking. The purpose of this study was to observe the corrosion behavior of steels with metal spray coatings in concrete using electrochemical methods And to evaluate the performance of the method according to the type of metal used in the metal spray. As a result, the Al metal spray coating showed the best performance, because Aluminum is oxidized in the cement mortar and forms alumina oxide film.

  • PDF

An Experimental Study on the Bond Strength of the Metal Sprayed Coating According to the Shape and Size of the Attachment (어태치먼트의 형상 및 크기가 금속용사 방식피막의 부착강도에 미치는 영향에 관한 실험적 연구)

  • Park, Seungi-Gi;Park, Jin-Ho;Ryu, Hua-Sung;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.109-110
    • /
    • 2016
  • The recent introduction of Metal spraying method apply to construction and civil steel structure is increasing. In applying the metal spraying lining process of construction and civil steel structure to secure the adhesion strength between the metal thermal spray coating and the steel structure and the highest priority requirements are required bond strength test reliable measurement accordingly. In this study, by calculating the deposition intensity and the standard deviation, coefficient of variation corresponding to the bonding area, unlike the shape of the attachment we compared the results.

  • PDF

레이저 표면합금화에 의한 Alloy 600의 미세조직 변화와 내부식성 향상

  • 신진국;강석중;우선기;이홍로;서정훈;김정수
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05b
    • /
    • pp.98-103
    • /
    • 1997
  • 원전 증기 발생기 재료로 사용되는 Alloy 600의 내부식성 향상을 위하여 레이저 범을 이용한 레이저 표면합금화(Laser Surface Alloying, LSA) 방법을 이용, 표면에 약 200$\mu\textrm{m}$ 두께의 합금층을 형성시켰다. 첨가한 원소는 크롬 또는 크롬과 니켈의 혼합체를 사용하였으며 첨가법으로는 도금과 용사를 이용하였다. 용사법으로 만든 LSA 시편의 특성과 문제점에 대해 고찰하고 이러한 문제점을 해결하는 방법으로 크롬 도금법을 택하였다. 이들 결과를 레이저 처리를 하지 않은 시편들과 비교하여 부식 거동을 분석하였다. 분석 결과 LSA 시편의 경우 As-received 시편, 레이저 표면 용융(LSM) 들과 비교해 아주 우수한 내부식성을 가졌으며 입계 내부식성도 크게 증가하였다. 이는 크롬 첨가로 인해 크롬의 농도가 많아져 부동태 피막의 형성이 쉬워졌기 때문으로 해석되었다.

  • PDF

An Evaluation of Physical Properties of Metal Sprayed Coating According to Concrete Surface Treatment Methods (콘크리트 표면 처리 방법에 따른 금속 용사 피막의 물리적 특성 평가)

  • Jang, Jong-Min;Jang, Hyun O;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.67-68
    • /
    • 2021
  • Social infrastructure facilities can be destroyed instantly when exposed to EMP (ElectroMagnetic Pulse), causing social chaos. However, concrete structures with low electrical conductivity cannot expect EMP shielding effect. Therefore, in this study, a metal sprayed thin film showing excellent EMP shielding performance was applied to a concrete structure to evaluate the metal spray welding efficiency and adhesion performance of the thin film according to the concrete surface treatment method. As a result according to the concrete surface treatment method, It was confirmed that the use of a roughening agent that generates physical irregularities in order to improve the welding efficiency and adhesion performance increases the physical performance of the concrete and metal sprayed thin film.

  • PDF

A Study on the Electrical Conductivity and Electromagnetic Pulse Shielding Characteristics of Metal Sprayed Coating (금속 용사 피막의 전기전도도 및 전자파 차폐 특성에 관한 연구)

  • Jang, Jong-Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.8-9
    • /
    • 2020
  • In this study, the electrical conductivity and shielding effect were evaluated according to the type of metal and the thickness of Metal sprayed coating. The metals used for the test are Cu, Cu-Ni and Cu-Zn, and the thicknesses were 100, 200, 500 um. Each metal sprayed coating was evaluated for electrical conductivity and electromagnetic shielding effect. When the thickness was 200 ㎛ or more, shielding effect 80 dB or more was satisfied at 1 GHz. However, in the case of Cu-Ni, there is little electrical conductivity at a thickness of 100 um or less due to the generated voids, and electromagnetic wave shielding performance cannot be expected. Therefore, To ensure electromagnetic shielding effect of structures, it is considered that the minimum thickness of metal spraying coating should be 200 um.

  • PDF