Assessment of Refuge Safety in Accomodations According to Awareness and Usability of Descending Life Lines and Simple Descending Life Lines (완강기 및 간이완강기의 인지·사용능력에 따른 숙박시설의 피난안전성 평가)

  • Han, Dong-Gew;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.4
    • /
    • pp.11-21
    • /
    • 2019
  • The purpose of this study is to evaluate the awareness and usability of descending life lines and simple descending life lines for fire situations in the accommodation of the public officials who are responsible for supervising the installation and maintenance of descending life lines and simple descending life lines. The main results of the study are summarized as follows. First, in comparison of the ability to distinguish between descending life lines and simple descending life lines, the majority of female public officers in general administrative services do not have the ability to distinguish between descending lifelines and simple descending life lines, so they should be able to improve their ability to distinguish descending life lines. Also, institutional strategies are needed to regularly receive education through the Safety Experience Center in order to prevent safety accidents such as falling in emergency situations. Second, as a result of verifying reusability of simple descending life lines by gender and occupation, most public officers with the exception of half of the firefighting officers were analyzed as having no ability to reuse the simple descending life lines. Therefore, it is necessary to change the relevant laws so that only the installation of descending life lines which can be used continuously is permitted, except for the simple descending life lines among the evacuation instruments to be additionally installed in each room of the accommodation. Third, in terms of the ability to perceive the maximum load of the descending life lines according to occupation, the perception ability of the rescuers was the highest and the perception ability of the fire service personnel was the lowest. In order to improve the perception abilities of the fire service personnel, it is necessary to strengthen the theoretical and practical education of descending life lines in collective education such as the command-enhancing training which is regularly carried out in fire service academy. Lastly, it is believed that it is more effective to conduct the experience training of the descending life lines by imagining the fire in accomodations rather than other facilities, because it is the location where fires are actually seen the most.

A Study on Analysis of Installation on the Actual State and Improvement about a Descending Life Line (완강기의 설치 실태 분석 및 개선에 관한 연구)

  • Choi, Yong-Hyuk;Park, Sung-Jin;Kim, Tae-Gu;Kim, Kwang-Il
    • Fire Science and Engineering
    • /
    • v.22 no.1
    • /
    • pp.105-114
    • /
    • 2008
  • This study investigated problems found with the installation of a descending life line which is one of the compulsory fire escape apparatuses required by the revised "Fire Service Act" of 2006 for multi-use facilities and multistory buildings. It presents an analysis of the causes and improvement details for the problems classified by type of item. To achieve the purpose, the total 367 problem points are indicated. The problems of Installation are unsuitable window glass using the descending life line(34%), required passage device is not attached(23.7%), the installation location is with required operation(20%) and damaged descending life line(20%) were investigated. In particular, the study looks at the stress analysis range for cracking window glass which is required for people to escape in an emergency. People have questioned unsuitable window glass for using the descending life line among the problems with the installation. As a result of stress analysis, window glass thickness of the place where the descending life line is installed must be 3 or 6 mm. In addition, this study indicates substantial improvement measures for installing the descending life line so I will actually be used as a fire escape apparatus to protect human lives, and not just to formally meet the Fire Service Act.

A Survey Study on the Learner's Recognition about the Descending Life Lines for the Fire Emergency Escaping Purpose (소방용 완강기에 대한 학습자의 인식 조사 연구)

  • Lee, Wonjoo;Lee, Chang-Seop
    • Fire Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.73-81
    • /
    • 2018
  • The purpose of this study is to survey the learner's recognition about the descending life lines for the fire emergency escaping purpose (DLL-FEEP). For that, we surveyed 307 adult males and females in Chungcheongnam-do, Daejeon metropolitan city, and Sejong metropolitan autonomous city. The surveyed data was statistically analyzed by SPSS 20.0 win program. In the results, 72.64% research participates have received a fire safety education. However, among them, 39.46% research participates have received a fire safety education without the contents of the DLL-FEEP. The style of the education for the DLL-FEEP is mainly the instructor-led training which is 79.26%. The 81.43% research participates have never used a DLL-FEEP. Based on the results in this study, the political proposal based on these results was as follows. We think that the expansion of the educational contents for the DLL-FEEP need in the fire safety education. We believe that results of this paper will help to serve as a basis for the efficient fire safety education with adults.

건축계뉴스

  • Korea Institute of Registered Architects
    • Korean Architects
    • /
    • no.7 s.184
    • /
    • pp.74-75
    • /
    • 1984
  • PDF

One-touch Descending Lifeline with Sliding Linkage Structure (슬라이드 링크 구조를 이용한 원터치 완강기)

  • Kim, Wonchan;Na, Dayul;Moon, Hyein;Kim, Sang-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.9
    • /
    • pp.42-47
    • /
    • 2021
  • A one-touch descending lifeline that can easily be installed and rapidly evacuated in the event of a fire accident in high-rise buildings was proposed to overcome difficulties of conventional descending lifeline such as complex installation methods and procedures. However, this lifeline exhibits limitations such as restrictions in installation location and large apparatus size. Therefore, this paper proposes a sliding-type descending lifeline, which has a similar operation to that of current one-touch descending lifeline and solves the aforementioned limitations. A double square link mechanism including a sliding four-bar linkage is proposed and the descending lifeline support is redesigned to unfold in two different planes, allowing 3D movement. Additionally, the shape of the support frame is designed to obtain two attachment surfaces that can be attached to a wall, irrespective of the angle between the window and the inner wall. FEA analysis using ABAQUS is performed to ensure that the robustness of the presented support complies with the Fire Control Act Enforcement Decree. Finally, the feasibility of the proposed sliding one-touch descending lifeline is verified through fabrication.

Robust Design of Descending Lifeline Using Double Square Linkage Mechanism (이중 4절링크 기구를 이용한 완강기 강건 설계)

  • Park, Jung-Woo;Yun, Seul-Gi;Jung, Geun-Hak;Jung, Min-Hee;Kim, Sang-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.6
    • /
    • pp.108-113
    • /
    • 2021
  • Recently, a new concept of a one-touch descending lifeline has been proposed to address the drawbacks of the conventional descending lifeline, which can be easily installed and quickly evacuated in the case of a fire emergency. All separate parts for escape are initially mounted in a box, and the link-type support is spread out of the window by pushing the handle attached to the box. In this study, the proposed double square linkage mechanism was redesigned, and its safety is verified by determining an appropriate moment of inertia of the link through finite element analysis using Abaqus. The shape and assembling method of the reel and speed controller were also modified such that the safety belt was simultaneously unfolded with link-type support. Finally, the feasibility of the proposed one-touch all-in-one descending lifeline was confirmed through fabrication.

Plans to Improve Safety Experience Education through the Experimental Analysis of Evacuation Equipment (피난기구 사용시간 실험분석을 통한 안전체험교육 개선방안)

  • Lee, Jeong Il;Lee, Sung Eun
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.35-42
    • /
    • 2019
  • The aim of this study is to investigate the direction of improvement of safety experience education through the analysis of the evacuation time experiment. For the study, test subjects were divided into groups of similar body size and weight. The test subjects were directly experienced four evacuation devices, and the experience time was measured. As a result of the analysis of the total time from the installation of the evacuation device to the escape, the time was measured in the order of Descending Life Line-Tilt-Down Rescue Line-Vertical Escape Chute-air safety mat. In the case of evaluating the evacuation time using evacuation mechanisms, the evacuation time was measured in the order of air safety mat-Tilt-Tilt-Down Rescue Line-Descending Life Line-Vertical Escape Chute. In the first and second experiments of the Descending Life Line, time differences were observed. The escape time using the Descending Life Line was reduced in the second experiment than in the first experiment. As shown in this result, education through experience has shown that behavioral confidence and time can be managed. The conclusion of this study is that the goal of safety education is to minimize human life and property damage. Therefore, in order to bring this effect to more people, it is necessary to make efforts to keep self-safe through experiential education.

Design of All-in-One Descending Lifeline with Reduced Usage Time (사용시간이 단축된 일체형 완강기 설계)

  • Yun, Seul-Gi;Park, Jung-Woo;Jung, Geun-Hak;Jung, Min-Hee;Kang, Sangwook;Kim, Sang-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.5
    • /
    • pp.21-26
    • /
    • 2020
  • A descending lifeline is the only self-escape fire apparatus for fire in high-rise buildings and is installed in most buildings according to fire-fighting law. However, it is difficult to properly use and quickly evacuate during an emergency due to its complex installation methods and procedures, even if users are pre-educated. In this paper, a new one-touch descending lifeline, which simplifies usage procedures and can be used regardless of whether users are educated, is proposed to solve the drawbacks of the conventional descending lifeline. All separate parts that require additional installation are initially assembled in a box, and the concept of a double square linkage is proposed to enable escape in a single motion of pushing the handle attached to the box. Three steps of kinematic design are explored to determine an appropriate configuration of double square linkage, and its dimensions are determined using Matlab and NX CAD software. The proposed all-in-one descending lifeline also follows the enforcement decree of the Fire Control Act, and its feasibility is verified through fabrication.

Development of basic research on the trap evacuation for emergency escape (비상탈출용 대피트랩 개발에 관한 기초 연구)

  • Choi, Kyu-Chool;Ra, Pan-Ju
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.322-330
    • /
    • 2010
  • 초고층 건축물의 급속한 증가는 건축물 화재 시 고층에서 보다 빨리 피난할 수 있는 구조적 피난설비를 요구한다. 기존의 구조용 완강기나 구조대는 고층에서는 피난자의 공포감을 충분히 해소하기에 역 부족이었다. 이러한 문제점을 보완한 성능을 갖추어 동시에 다수의 피난자를 대피시킬 수 있는 새로운 피난기구가 요구되고 있다. 이에 고층에서도 동시에 여러 사람이 안전하고, 신속하게 피난층까지 무사히 대피가 가능한 유압식 피난기구를 고안하고, 개략 설계하게 되었다. 이 연구를 기초로 향후 상세설계를 마친 후 고층 건축물에 적용되어 안전한 피난기구가 되었으면 한다.

  • PDF

A Study on the Development of Evacuation Equipments for Units in High-rise Apartment (고층 공동주택의 세대 내 피난시설의 개발에 관한 연구)

  • Min, Se-Hong;Sa, Jea-Chun;Jang, Young-Jin;Lee, Jae-Moon;Nam, Jung-O
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.183-186
    • /
    • 2011
  • 모든 공동주택에 적용되고 있는 기존의 피난시설은 고층부분에서 사용의 제한, 세대 간 보안 및 사용자의 제약 등으로 실제 현장에 적용하여 사용하는 되는 많은 문제점을 내포하고 있다. 또한, 이와 관련하여 공동주택의 용도 특성상 조기 피난이 이루어지지 못하는 경우가 빈번하여 화재 때문에 세대 내 출구가 폐쇄되고 재해약자가 사용하는데 어려우며, 화염과 복사열로부터 안전을 해결하기에는 현재 공동주택에서 보편적으로 설치되어있는 완강기로 이러한 문제를 해결하기에는 매우 미흡한 실정이다. 이에 본 연구에서는 이러한 문제점을 해결할 피난방법이 적용된 피난시설을 제안하고자 한다. "피난대피시설"은 공동주택 발코니 또는 외벽에 콤팩트(compact)하게 접혀 있다가 화재 시 수동 또는 감지기와 연동해 쉽게 작동되어 대피공간 용도와 유사시 자력으로 피난층까지 피난할 수 있는 구조이다. 또한, 화재실과 접하는 부분은 $1,200^{\circ}C$의 복사열을 차단할 수 있는 단열소재로 구성되며 1차적으로는 화재 장소에서 외부 공간으로 일탈한 후에 2차적으로 아래층으로 사다리를 이용하여 피난할 수 있게 되어 있다. 본 연구개발의 주안점은 화재 시화염과 복사열로부터 공간 일탈을 하여 재실자를 보호할 수 있는 대피공간의 개념과 피난시설에서 피난층으로 피난할 수 있는 적극적인 피난방법을 접목한 것이 피난시설 개발의 핵심이다.

  • PDF