• Title/Summary/Keyword: 온도 성층화

Search Result 76, Processing Time 0.028 seconds

Prediction of Stratification Model for Diffusers in Underfloor Air Distribution System using the CFD (CFD를 활용한 바닥공조시스템 디퓨저의 성층화 모델 예측)

  • Son, Jeong-Eun;Yu, Byeong-Ho;Pang, Seung-Ki;Lee, Kwang Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.3
    • /
    • pp.105-110
    • /
    • 2017
  • Underfloor air distribution (UFAD) is an air distribution strategy for providing ventilation and space conditioning in buildings. UFAD systems use the underfloor plenum beneath a raised access floor to provide conditioned air through floor diffusers that create a vertical thermal stratification during cooling operations. Thermal stratification has significant effects on energy, indoor air quality, and thermal comfort performance. The purpose of this study was to characterize the influence of a linear bar grille diffuser on thermal stratification in both interior and perimeter zones by developing Gamma-Phi based prediction models. Forty-eight simulations were carried out using a Computational Fluid Dynamics (CFD) technique. The number of diffusers, the air flow supply, internal heat gains, and solar radiations varied among the different cases. Models to predict temperature stratification for the tested linear bar grille diffuser have been developed, which can be directly implemented into dynamic whole-building simulation software such as EnergyPlus.

Long-term Simulation of Water Temperature in Soyanggang Reservoir in Response to RCP 4.5 Climate Scenario (RCP 4.5 기후 시나리오에 따른 소양호 수온 변화 장기 모의)

  • Yun, Yeojeong;Park, Hyungseok;Chung, Sewoong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.265-265
    • /
    • 2019
  • 기후변화로 의한 기온의 상승은 가뭄, 홍수와 같은 재해를 일으킬 뿐만 아니라 깊은 호수나 저수지와 같은 수자원에도 용존 산소, 물질, 영양소 및 식물플랑크톤의 수직적 분포 등과 같은 다양한 부분에 영향을 미친다. 본 연구의 목적은 SWAT, HEC-ResSim 및 CE-QUAL-W2(이하 W2)모델을 사용하여 미래의 기후 변화에 따른 소양호의 수온, 성층강도 및 열적 안정성의 변화를 장기 예측하고 그 영향을 평가하는데 있다. W2 모델의 보정은 2005 년부터 2015 년까지의 실측 과거 데이터를 이용하여 보정하였고 기후변화 시나리오는 IPCC의 AR5 RCP 4.5 시나리오를 사용하였다. 기후자료는 GCM 모델인 HadGEM2-AO 결과를 상세화하여 모의기간의 자료를 생성하였다. SWAT모델을 이용하여 모의기간인 2016 년부터 2070 년까지 일단위로 저수지 유입을 예측했으며 HEC-ResSim모델을 이용하여 소양강댐 저수지 운영 조건에 따라 저수지 방류량 및 수위 변화를 모의하였다. 수온 해석을 위해 W2를 적용하여 저수지의 장기간의 수온 변화를 예측하였다. 결과적으로 대기 온도는 $0.0279^{\circ}C/year$(p < 0.05) 상승할 것으로 예측되었으며, 동일기간 상층(수면으로부터 5m 깊이)과 하층 (바닥으로부터 5m 높이) 수온은 각각 $0.0191^{\circ}C$/년(p < 0.05) 및 $0.008^{\circ}C$/년(p < 0.05) 상승할 것으로 예측되었다. 모의된 수온을 계절별로 분석했을 때 상층수온은 여름철 가장 큰 폭으로 상승하였으며 하층의 경우 겨울철에 가장 큰 폭으로 상승하였다. 계절별 상-하층 수온의 차는 여름이 가장 컸으며, 겨울에 온도차가 가장 작았다. 또한 미래 온도의 상승에 따라, 소양호의 성층 강도가 강해지는 경향을 보였으며 상층 및 하층의 온도차 $5^{\circ}C$를 기준으로 성층이 형성되는 기간은 큰 변동이 없었으나 소멸되는 시점이 점점 늦어지는 추세를 보여 성층 형성 기간이 길어지는 것으로 나타났다. 저수지 표면의 수온 상승은 식물플랑크톤의 계절 성장률에 영향을 미쳤는데, 특정 조건에서 규조류는 최적 성장 범위를 벗어나는 고온 조건에서 성장속도가 감소하였으나 녹조류와 남조류의 출현 시기가 빨라지며 장기화될 것으로 예측되었다.

  • PDF

Global Temperature Trends of Lower Stratosphere Derived from the Microwave Satellite Observations and GCM Reanalyses (마이크로파 위성관측과 모델 재분석에서 조사된 전지구에 대한 하부 성층권 온도의 추세)

  • Yoo, Jung-Moon;Yoon, Sun-Kyung;Kim, Kyu-Myong
    • Journal of the Korean earth science society
    • /
    • v.22 no.5
    • /
    • pp.388-404
    • /
    • 2001
  • In order to examine the relative accuracy of satellite observations and model reanalyses about lower stratospheric temperature trends, two satellite-observed Microwave Sounding Unit (MSU) channel 4 (Ch 4) brightness temperature data and two GCM (ECMWF and GEOS) reanalyses during 1981${\sim}$1993 have been intercompared with the regression analysis of time series. The satellite data for the period of 1980${\sim}$1999 are MSU4 at nadir direction and SC4 at multiple scans, respectively, derived in this study and Spencer and Christy (1993). The MSU4 temperature over the globe during the above period shows the cooling trend of -0.35 K/decade, and the cooling over the global ocean is 1.2 times as much as that over the land. Lower stratospheric temperatures during the common period (1981${\sim}$1993) globally show the cooling in MSU4 (-0.14 K/decade), SC4 (-0.42 K/decade) and GEOS (-0.15 K/decade) which have strong annual cycles. However, ECMWF shows a little warming and weak annual cycle. The 95% confidence intervals of the lower stratospheric temperature trends are greater than those of midtropospheric (channel 2) trends, indicating less confidence in Ch 4. The lapse rate in the trend between the above two atmospheric layers is largest over the northern hemispheric land. MSU4 has low correlation with ECMWF over the globe, and high value with GEOS near the Korean peninsula. Lower correlations (r < 0.6) between MSU4 and SC4 (or ECMWF) occur over $30^{\circ}$N latitude belt, where subtropical jet stream passes. Temporal correlation among them over the globe is generally high (r > 0.6). Four kinds of lower stratospheric temperature data near the Korean peninsula commonly show cooling trends, of which the SC4 values (-0.82 K/decade) is the largest.

  • PDF

A Three-Dimensional Turbulence Model far the Thermal Discharge into Cross-Flow Field (가로흐름 수역으로 방출되는 3차원 온배수 난류모형)

  • 이남주;최흥식;허재영
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.7 no.2
    • /
    • pp.148-155
    • /
    • 1995
  • For an accurate prediction of the temperature Held induced by surface discharge of heated water into an ambient cross-flow field. a three-dimensional near-field numerical model using k-$\varepsilon$ turbulence clousure is developed Rather restricted as it is, the numerical results of the model agree well with the experimental data. The developed model simulates quite adequately the stratification, gravitational lateral spreading, and upward entrainment of thermal jet which cannot be simulated by a depth-integrated two-dimensional numerical model, as well as the interaction with cross-flow.

  • PDF

A Numerical Model for Wind-Induced Circulation in a Thermally Stratified Flow (수온성층흐름에서 바람에 의해 발생하는 순환흐름을 해석하기 위한 수치모형개발)

  • Lee, Jin-Woo;Kim, Hyung-Jun;Cho, Yong-Sik
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.10
    • /
    • pp.911-920
    • /
    • 2010
  • The closed water bodies, such as reservoirs and lakes, could be contaminated by an inflow of pollutants in the upstream as well as a stratification caused by seasonal natural phenomena. The vertical circulation particularly plays an important role in reduction of environmental pollutants. The factors of the vertical circulation are the temperature, wind, thermal diffusivity and sunlight. The wind is probably the most significant factor among them. Thus, it is necessary to describe the validation and application of a three-dimensional numerical model of wind-induced circulation in a thermally stratified flow. In this paper, a three-dimensional numerical model for the thermally stratified flows is presented. The model is conducted in three steps to calculate the velocity components from the momentum equations in x- and y- axis directions, the elevations from the free surface equation and the temperature from the scalar transport equation. Numerical predictions are compared with available analytical solutions for the sloshing free surface movement in a rectangular basin. The numerical results generally show a reasonable agreement with analytical solutions. And the model is applied to the circulation for the wind induced flow in a thermally stratification. Consequently, the developed model is validated by two verifications and phenomena of the internal flow.

An Experimental Study on Thermal Stratification of Pressurized Plenum Underfloor Air Distribution System during Cooling (가압식 바닥급기 시스템의 여름철 성층화 경향에 관한 실험적 연구)

  • Kim, Dong-Hee;Yu, Ki-Hyung;Cho, Dong-Woo;Seo, Jung-Seok;Han, Sung-Phil
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.340-345
    • /
    • 2007
  • The underfloor air distribution system has been attracting to architects and building owners as one of valuable system for the renovated and newly office building. In this paper, we discussed the thermal stratification profile of pressurized plenum underfloor air distribution(UFAD) according to indoor setting temperature, diffuser number, diffuser type. For this, the space of office building(H corp.) is selected for measuring the air volume of underfloor diffuser and vertical temperature profile. As a result, the thermal stratification profile is influenced by the number and type of the underfloor diffuser and thermal storage character of the underfloor. Whereas indoor setting temperature have a lower significant impact on thermal stratification.

  • PDF

Effect of Stabilizing Thermal Gradients on Natural Convection in a Completely Confined Rectangular Enclosure (안정온도구배가 밀폐용기내의 자연대류에 미치는 영향)

  • 김무현;이진호;장은구
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.6
    • /
    • pp.1330-1338
    • /
    • 1989
  • 본 연구에서는 직각밀폐용기의 수평경계면이 단열인 경우뿐만 아니라 등온 조건을 갖는 경우에 대해 실험적으로 연구하여 경계조건의 변화가 직각밀폐용기내 흐름 및 열전달에 미치는 영향, 특히 등온조건을 갖는 경우 수직 온도차에 따르는 안정온도 구배효과로 예상되는 흐름의 억제, 지연효과를 작종 물리적 변수들의 영향과 함께 세밀히 조사하였다.

Numerical Simulation of Selective Withdrawal in Stably Stratified Flows (안정성층류에서 선택취수의 수치해석)

  • Paik, Joong-Cheol
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.11
    • /
    • pp.973-984
    • /
    • 2005
  • A three-dimensional thermal hydrodynamic model is developed for carrying out unsteady simulation of the selective withdrawal of the stably stratified flow in a geometrically complex, natural reservoir The governing equations are discretized on a non-staggered grid using a second-order accurate, finite-volume scheme. The numerical model is validated by applying it to simulate three-dimensional, turbulent, stratified, shear-layer flow case. The numerical predictions appear to capture reasonably well the general shape of velocity and temperature profiles observed in the laboratory experiments, while significant overestimation of the magnitude of velocity profiles is observed in the application to the flow in a natural reservoir. The physics of selective withdrawal as emerge from the numerical simulations are also discussed.

Stratified Degree Characteristics on Fuel Mixture According to Ambient Temperature and Pressure in a Constant Volume Combustion Chamber (정적연소기내에서의 분위기 온도 및 압력에 따른 혼합기 분포에 관한 성층화 정도 특성)

  • Lee Kihyung;Lee Changsik;Lee Changhee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.2 s.233
    • /
    • pp.180-188
    • /
    • 2005
  • It is well known that a lean burn engine caused by stratified mixture formation has many kinds of advantages to combustion characteristics, such as higher thermal efficiency and lower CO, NOx levels than conventional homogeneous mixture combustion. Although this combustion can achieve low fuel consumption technology, it produces much unburned hydrocarbon and soot because of heterogeneous equivalence ratio in the combustion chamber. Therefore, the stratified mixture formation technology is very important to obtain the stable lean combustion. In this paper, fundamental studies for stratified combustion were carried out using a constant volume combustion chamber. The local effect of mixture formation according to control air-fuel distribution in the chamber was examined experimentally. In addition, the effect of turbulence on stratified charge combustion process was observed by schlieren photography. From this study, we found that the flame propagation speed increase with swirl flow and the swirl promotes the formation of fuel and air mixture.

Study on Stratification according to Diffuser Shape of the Thermal Storage Tank in Integrated Energy (집단에너지 공급 축열조의 디퓨져 형태별 성층화 연구)

  • Jang, Cheol-Yong;Cho, Soo;Choi, Seok-Yong
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.300-303
    • /
    • 2008
  • The stratification effect was investigated with four different types of diffuser shape in a thermal storage tank. For this study, experimental facility was constructed, which was composed of experimental thermal storage tank, hot and cold water storage tanks, boiler, chiller, data acquisition system, etc.. Visualization and lab scale experimental result showed that radial curved type diffuser was the highest degree of stratification among the four diffuser shapes.

  • PDF