• Title/Summary/Keyword: 온도편차

Search Result 450, Processing Time 0.025 seconds

Study of Reduction of Mismatch Loss of a Thermoelectric Generator (열전발전 시스템의 부정합손실 저감방안 연구)

  • Choi, Taeho;Kim, Tae Young
    • Journal of Convergence for Information Technology
    • /
    • v.12 no.3
    • /
    • pp.294-301
    • /
    • 2022
  • In this study, a multi-layer cascade (MLC) electrical array configuration method for thermoelectric generator consisting of plural number of thermoelectric modules (TEMs) was proposed to reduce mismatch loss caused by temperature maldistribution on the surfaces of the TEMs. To validate the effect of MLC on the mismatch loss reduction, a numerical model capable of reflecting multi-physics phenomena occuring in the TEMs was developed. MLC can be employed by placing a group of TEMs experiencing relatively low temperature differences in an electric layer with more electrical branches while locating a group of TEMs experiencing relatively high temperature differences in an electric layer with less electrical branches. The TEMs were classified using the temperature distribution obtained by the numerical model. A MLC with an optimal electrical branch ratio showed a 96.5% of electric power generation compared to an ideal case.

A study on the influence of the China Coastal Waters nearby Jeju Island Using Satellite Data (위성 자료를 이용한 제주도 주변해역의 중국대륙연안수 영향에 관한 연구)

  • Cho Han-Keun;Yoon Hong-Joo
    • Proceedings of the KSRS Conference
    • /
    • 2006.03a
    • /
    • pp.91-94
    • /
    • 2006
  • China Coastal Waters (CCW) usually appears in the seas surrounding Jeju Island annually(June to October) and is very pronounced in August. Generally, low-salinity water appears to the western seas of Jeiu Island from June through October and gradually propagates to the eastern seas, where CCW meets the Tsushima Current. Empirical orthogonal function (EOF) analysis of SLAs and SSTs indicated that the valiance in SLAs and SSTs was 95.05%(the first mode to third mode) and 98.09%(the first mode), respectively The PSD of the western waters for the first mode of EOF analysis of SLAs was stronger than that of the eastern waters because of the influence of CCW. The PSD for the EOF analysis of SSTs was similar in all areas (the Yangtze Estuary and the seas to the west and east of Jeju Island), with a period of approximately 260 days.

  • PDF

Influence Analysis of China Coastal Water in the Seas Surrounding Jeju Island using Satellite Data and Empirical Orthogonal Function Analysis (위성자료와 경험직교함수를 이용한 제주도 주변해역의 중국대륙연안수 영향 연구)

  • Yoon Hong-Joo;Cho Han-Keun;Ahn Yu-Hwan
    • Korean Journal of Remote Sensing
    • /
    • v.21 no.6
    • /
    • pp.469-482
    • /
    • 2005
  • China Coastal Waters (CCW) usually appears in the seas surrounding Jeju Island annually(June to October) and is very pronounced in August. Generally, low-salinity water appears to the western seas of Jeju Island from June through October and gradually propagates to the eastern seas, where CCW meets the Tsushima Current. Empirical orthogonal function (EOF) analysis of SLAs and SSTs indicated that the variance in SLAs and SSTs was $95.01\%$(the first mode to third mode) and $98.09\%$(the first mode), respectively. The PSD of the western waters for the first mode of EOF analysis of SLAs was stronger than that of the eastern waters because of the influence of CCW. The PSD for the EOF analysis of SSTs was similar in all areas (the Yangtze Estuary and the seas to the west and east of Jeju Island), with a period of approximately 260 days.

Development of a New Water Circulating System for Hot Water Mattress Without Water Pump (새로운 펌프 없는 온수매트용 온수 순환 시스템의 개발)

  • Je, Jong Joo;Sohn, Chang Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.11
    • /
    • pp.1031-1036
    • /
    • 2013
  • The motor-driven water pump boiler for a water circulating mattress generates noise and vibration as it supplies a large water flow rate. A non-pump boiler can reduce such noise and vibration, however, the water circulation flow rate becomes lesser than that in motor-driven water pump boilers, and a large temperature deviation occurs between the inlet and the outlet of the mattress. In this research, a new non-pump boiler for water circulating mattress is developed and its performance is experimentally validated and compared with the existing non-pump boilers. The experimental results show that temperature response time is improved and temperature deviation is reduced.

Analysis of the relationship between composition and viscosity of soda-lime glass bottles (소다석회유리병의 조성과 점도의 상관관계 분석)

  • Seung Min Kang;Chang-Sam Kim
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.33 no.1
    • /
    • pp.7-14
    • /
    • 2023
  • Forty Viscosity data of glass bottles fabricated in a glass bottle manufacturing plant for 4 years were calculated using Lakatos model. The relationship between the glass bottle compositions and viscosities at log η of 3, 6.6, 10 and 12.3 Pa·s was analyzed. MgO that was a component of the glass bottle showed the maximum coefficient of variation of 0.89, but it gave a very small change in the viscosity. CaO that was another component of the glass bottle lowered the isokom temperature because it tended to reduce the number of non-bridging oxygen at temperature below a softening point.

Performance Improvement of a Temperature and Humidity Measuring System for Strawberry Cultivation Greenhouse (딸기재배 온실용 온습도 계측시스템의 성능개선)

  • Jeong, Young Kyun;Lee, Jong Goo;Ahn, Enu Ki;Seo, Jae Seok;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.29 no.2
    • /
    • pp.110-119
    • /
    • 2020
  • This study investigates the improvement in the performance of a temperature and humidity measuring system developed by Company A using the Aspirated Radiation Shield (ARS). The shield has been used in the industry and its accuracy was verified recently. The study also experimentally examines the impact of the wind speed of the ARS device on temperature and humidity. The results are summarized as follows. Before the improvement of the system, the temperature of Company A's system was up to 10.2℃ higher than that measured by the ARS device, and the measured relative humidity was approximately 20.0% lower. After improving the system, the temperature and relative humidity of nodes 1 and 2 were found to be almost identical. The temperature deviations including the maximum, mean, and minimum temperatures between those measured in node 2 and by ARS were approximately 0.2 to 0.7℃, respectively; further, the values measured by ARS tended to be slightly lower or higher. In terms of relative humidity, the ARS measurements yielded values approximately 10.0% higher immediately after sunset; otherwise, the values were approximately 1.9% lower. Moreover, when node 1 was set to minimum-middle, middle-maximum, and maximum, the deviations including the maximum, mean, and minimum temperatures of nodes 1 and 2 were 0.1 to 0.4℃, 0.0 to 0.2℃, and 0.0 to 0.5℃, respectively. The deviations including the maximum, average, and minimum temperatures of the three points of node 1 and the ARS ranged from 0.2 to 0.5℃, 0.1 to 2.2℃, and 0.1 to 1.1℃, respectively, indicating that the temperature deviation according to the wind speed was negligible. In addition, considering the results of the previous study with those from this study, the optimal wind speed to improve the temperature deviation is considered to be in the range of 1.0~2.0 m·s-1.

Effects of mold temperature on the shrinkage and surface quality of the Polystyrene and Polypropylene parts made by injection molding (금형온도가 Polystyrene 과 Polypropylene 성형품의 수축 및 외관품질에 미치는 영한에 관한 연구)

  • 이재원;김동학
    • Proceedings of the KAIS Fall Conference
    • /
    • 2002.05a
    • /
    • pp.130-133
    • /
    • 2002
  • 금형온도가 사출 성형품에 미치는 영향 중에 결정성수지인 PP(Polypropylene)와 비결정성수지인 PS(Polysyene)는 금형온도가 높아짐에 따라 각기 다른 결과를 나타내었다. PS성형품은 금형온도가 높을수록 수축율이 줄어들고 두께 편차가 적어지는 경향을 관찰할 수 있었고, PP성형품의 경우에는 결정의 생성으로 인한 상반된 경향이 관찰되었다. 또한, 금형온도에 따른 캐비티의 매끄러운 면과 거친 면의 결과로 볼 때 금형온도가 높을수록 캐비티의 충전성 및 전사성이 향상되었다. MmSH(Momentary Mold Surface Heating)조건인 경우는 수축율과 전사성 모두다 양호한 결과를 보여주었다.

Effects of Mold Temperature on the Weldline and Dimensional Stability of Injection-molded Parts (금형온도가 사출성형품의 웰드라인과 치수안정성에 미치는 영향에 관한 연구)

  • 김동학;이재원;김태완
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.3
    • /
    • pp.172-176
    • /
    • 2003
  • In this paper, we studied the effects of mold temperature on the microstructure of injection molded parts. The weld line decreases in length and width as mold temperature increases. We investigated the dimensional stability of the parts made of two kinds of resin(polypropylene and polystyrene) by varying the mold temperature. As the mold temperature is high, both the shrinkage ratio and the thickness difference for the PS parts decreases. But the observation of PP parts shows a tendency to increase. The easiness of cavity filling and transcription of the mold texture is improved as the mold temperature is high.

  • PDF

Determination of divider resistance in voltage divider circuits used NTC thermistor. (NTC thermistor를 사용한 voltage divider 회로에서 divider resistance결정)

  • Ku, Ja-Hun;Kim, Jong-Dae;Kim, Yu-Seop;Park, Chan-Young;Lee, Wan-Yeon;Song, Hae-Jung
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2010.06c
    • /
    • pp.221-225
    • /
    • 2010
  • 본 연구에서는 제한된 온도 영역에서 보통 정밀 온도 측정 소자로 많이 쓰이는 NTC 써미스터를 사용하여 전압 분배 회로(voltage divider circuits)를 구성하였다. 분압 저항이 온도측정 해상도에 미치는 영향을 분석하고, 회로의 분압 저항을 결정하는 방법으로서 측정하고자 하는 온도 구간의 최대 온도와 최저 온도의 NTC 써미스터 저항 값을 조화평균을 사용하여 분압 저항(divider resistance)으로 사용하였다. 선택한 분압 저항이 이상적인 저항인지에 대하여 조화평균으로 계산한 분압 저항과 대조군 저항으로 전압 분배 회로를 병렬로 구성하였다. 센서들을 항온조 넣어 설정온도($50^{\circ}C$, $70^{\circ}C$, $90^{\circ}C$)에서 각각의 온도를 측정한 후 측정 데이터의 표준편차를 구하여 평균 온도 분해능을 비교 하는 실험을 하였다. 실험결과 측정온도 구간의 최대 온도와 최소 온도에서의 NTC 써미스터 저항 값을 조화평균으로 계산한 분압 저항 값이 대조군 저항에 비해 설정온도에서 보다 높은 평균 온도 분해능(sensing resolution)을 보였다.

  • PDF

Effect of Manufacturing Parameters on Characteristic of Thin Film Resistor (박막저항기 특성에 미치는 제조 공정 인자의 영향)

  • Park Hyun-Sik;Yu Yun-Seop
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.12 no.1 s.34
    • /
    • pp.1-7
    • /
    • 2005
  • The effect of trimming process to adjust accurate resistance of a thin-film resistor was studied with respect to low temperature coefficient of resistance(TCR) and high precision. The characteristics of a thin-film resistor fabricated by sputtering were investigated depending on trimming condition and annealing temperature. Measured results showed that the characteristic of a thin-film resistor was degraded with increased trimming speed. However, an average resistance deviation and a TCR were improved to $0.26\%$ and 52.77[ppm/K], respectively, through annealing treatment. Also, thin-film resistors with 1 k$\Omega$ and 10k$\Omega$ showed better performance compared to a resistor with 100k$\Omega$. The Optimal trimming speed and annealing temperature were 20mm/sec and 539K, respectively, and under this optimal condition, a thin-film resistor with an average resistance deviation of $0.31\%$ and a TCR of below 10[ppm/K] was obtained.

  • PDF