• Title/Summary/Keyword: 오차 제거

Search Result 1,050, Processing Time 0.027 seconds

A New Endpoint Detection Method Based on Chaotic System Features for Digital Isolated Word Recognition System (음성인식을 위한 혼돈시스템 특성기반의 종단탐색 기법)

  • Zang, Xian;Chong, Kil-To
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.5
    • /
    • pp.8-14
    • /
    • 2009
  • In the research field of speech recognition, pinpointing the endpoints of speech utterance even with the presence of background noise is of great importance. These noise present during recording introduce disturbances which complicates matters since what we just want is to get the stationary parameters corresponding to each speech section. One major cause of error in automatic recognition of isolated words is the inaccurate detection of the beginning and end boundaries of the test and reference templates, thus the necessity to find an effective method in removing the unnecessary regions of a speech signal. The conventional methods for speech endpoint detection are based on two linear time-domain measurements: the short-time energy, and short-time zero-crossing rate. They perform well for clean speech but their precision is not guaranteed if there is noise present, since the high energy and zero-crossing rate of the noise is mistaken as a part of the speech uttered. This paper proposes a novel approach in finding an apparent threshold between noise and speech based on Lyapunov Exponents (LEs). This proposed method adopts the nonlinear features to analyze the chaos characteristics of the speech signal instead of depending on the unreliable factor-energy. The excellent performance of this approach compared with the conventional methods lies in the fact that it detects the endpoints as a nonlinearity of speech signal, which we believe is an important characteristic and has been neglected by the conventional methods. The proposed method extracts the features based only on the time-domain waveform of the speech signal illustrating its low complexity. Simulations done showed the effective performance of the Proposed method in a noisy environment with an average recognition rate of up 92.85% for unspecified person.

Design of a 2.5V 300MHz 80dB CMOS VGA Using a New Variable Degeneration Resistor (새로운 가변 Degeneration 저항을 사용한 2.5V 300MHz 80dB CMOS VGA 설계)

  • 권덕기;문요섭;김거성;박종태;유종근
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.9
    • /
    • pp.673-684
    • /
    • 2003
  • A degenerated differential pair has been widely used as a standard topology for digitally programmable CMOS VGAs. A variable degeneration resistor has been implemented using a resistor string or R-2R ladder with MOSFET switches. However, in the VGAs using these conventional methods, low-voltage and high-speed operation is very hard to achieve due to the dc voltage drop over the degeneration resistor. To overcome this problem a new variable degeneration resistor is proposed where the dc voltage drop is almost removed. Using the proposed gain control scheme, a low-voltage and high-speed CMOS VGA is designed. HSPICE simulation results using a 0.25${\mu}{\textrm}{m}$ CMOS process parameters show that the designed VGA provides a 3dB bandwidth of 360MHz and a 80dB gain control range in 2dB step. Gain errors are less than 0.4dB at 200MHz and less than l.4dB at 300MHz. The designed circuit consumes 10.8mA from a 2.5V supply and its die area is 1190${\mu}{\textrm}{m}$${\times}$360${\mu}{\textrm}{m}$.

Body Segment Length and Joint Motion Range Restriction for Joint Errors Correction in FBX Type Motion Capture Animation based on Kinect Camera (키넥트 카메라 기반 FBX 형식 모션 캡쳐 애니메이션에서의 관절 오류 보정을 위한 인체 부위 길이와 관절 가동 범위 제한)

  • Jeong, Ju-heon;Kim, Sang-Joon;Yoon, Myeong-suk;Park, Goo-man
    • Journal of Broadcast Engineering
    • /
    • v.25 no.3
    • /
    • pp.405-417
    • /
    • 2020
  • Due to the popularization of the Extended Reality, research is actively underway to implement human motion in real-time 3D animation. In particular, Microsoft developed Kinect cameras for 3D motion information can be obtained without the burden of facilities and with simple operation, real-time animation can be generated by combining with 3D formats such as FBX. Compared to the marker-based motion capture system, however, Kinect has low accuracy due to its lack of estimated performance of joint information. In this paper, two algorithms are proposed to correct joint estimation errors in order to realize natural human motion in motion capture animation system in Kinect camera-based FBX format. First, obtain the position information of a person with a Kinect and create a depth map to correct the wrong joint position value using the human body segment length constraint information, and estimate the new rotation value. Second, the pre-set joint motion range constraint is applied to the existing and estimated rotation value and implemented in FBX to eliminate abnormal behavior. From the experiment, we found improvements in human behavior and compared errors between algorithms to demonstrate the superiority of the system.

Introduction of Clean Techniques for Trace Metal Analysis in Seawater (해수 중의 미량금속 분석을 위한 청결기술의 소개)

  • Kim, Kyung-Tae;Kim, Eun-Soo;Ra, Kong-Tae;Moon, Deok-Soo;Kim, Hyeon-Ju
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.15 no.2
    • /
    • pp.157-164
    • /
    • 2009
  • The metals such as Al, Ag, Au, Cu, Cd, Co, Fe, Ni, Pb, Zn, etc are present at very low concentration in seawater and are classified as so-called trace metals. Whiles some of them are used in metabolism of living organism as a micronutrient, they may show toxic effects on organisms in case of a limited threshold concentration of them Plenty of studies on trace metals have been performed bemuse trace metals have a persistent influence and an adverse effect on marine environment and ecosystem. For long years, when the concentration of trace metals in natural waters such as seawater and fresh water are measured with high precision and accuracy, some systematic errors have been recognized to be present in measurements. Since 1975 in US and European countries, the measured concentration of trace metals in seawater have been found to be lower by factors of 10-1,000 than the previous data of trace metals measurements and the vertical profiles of the measurements have been shown to reflect well-known biological, physical and geochemical processes. These results are attributed to great advances in analytical instrumentation and methodology for trace metals measurements. Precautions against the contamination of samples are required to be taken in the process of sampling, storage, and analysis of samples. However, in Korea, erroneous data of trace metals with regard to ocean and marine environment related survey and investigations are reported The lock of exact understanding and information regarding precautions in sampling, storage and analysis of samples lead to the deterioration of data quality, especially in the analysis of trace metals. The major procedures to obtain the accurate data of trace metals in natural waters are introduced for applying to the study and assessment of marine environments.

  • PDF

A Study on the Precise Lineament Recovery of Alluvial Deposits Using Satellite Imagery and GIS

  • 이수진;황종선;이동천;김정우;석동우
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2003.04a
    • /
    • pp.62-62
    • /
    • 2003
  • Landsat TM 영상을 이용, 명암차가 높은 산악 지역에 적용해왔던 알고리즘을 개선하여 비교적 명암차가 낮고 넓게 분포하는 충적층 지역의 선구조를 추출하는 알고리즘을 개발하였다. 수치지형모델(OEM)에 대하여 Local Enhancement 를 이용해서 평탄한 지역을 선정하여 이로부터 충적층을 추출하였다. Zevenbergen & Thorno's Method를 3×3 moving windowing을 통해서 최대 경사방향과 경사를 구해서 충적층을 지나는 선구조 요소를 추출하고 다시 Hough 변환을 이용해서 1차 선구조를 추출하였다 이를 이용하여 충적층의 직각방향의 지형단면의 경사를 유추해서 spline 보간법을 이용해 단면의 최저점을 구하고 이 구해진 점들을 다시 Hough 변환을 이용해서 최종 선구조를 추출하였다. 본 연구에서 사용한 알고리즘은 기존 알고리즘에서 사용된 소창문보다 훨씬 큰 충적층이 분포하는 지역의 지형 경사가 수렴하는 부분에 선구조가 뚜렷이 나타남을 볼 수 있다. 최대경사방향과 경사를 구해서 얻어진 1 차선구조와 최종 선구조에서 선구조 방향이 다소 차이를 보인다. 1 차 선구조의 수직방향 지형단면의 자료를 이용함에 있어, 지형 단면의 시작정과 끝지점을 임의적으로 결정하는 것이 아니라, 충적층을 가로질러 최고점까지 또는 다음 충적층이 나을 때까지의 자료를 이용해서 보간법을 사용하였고, 충적층의 넓이에 따라 보간할 자료량의 차이에 의한 오차가 발생할 수 있다. 넓은 충적층에서 선구조가 잘 추출되는 반면에 좁은 충적층이 분포하거나 계곡에 해당하는 지역에l서는 경사수렴부와 일치하지 않는 선구조가 추출되었다. 이는 향후 계속적으로 연구해서 보완되어야 할 것으로 사료된다.페클 잡영 제거 정도에 있어 다른 필터들과 큰 차이가 없지만 경계선보존지수는 다른 필터들에 비하여 가장 우수함을 확인할 수 있었다.rbon 탐식효율을 조사한 결과 B, D 및 E 분획에서 유의적인 효과를 나타내었다. 이상의 결과를 종합해볼 때, ${\beta}$-glucan은 고용량일 때 직접적으로 또는 $IFN-{\gamma}$ 존재시에는 저용량에서도 복강 큰 포식세로를 활성화시킬 뿐 아니라, 탐식효율도 높임으로써 면역기능을 증진 시키는 것으로 나타났고, 그 효과는 crude ${\beta}$-glucan의 추출조건에 따라 달라지는 것을 알 수 있었다.eveloped. Design concepts and control methods of a new crane will be introduced in this paper.and momentum balance was applied to the fluid field of bundle. while the movement of′ individual material was taken into account. The constitutive model relating the surface force and the deformation of bundle was introduced by considering a representative prodedure that stands for the bundle movement. Then a fundamental equations system could be simplified considering a steady state of the process. On the basi

  • PDF

Application of Residual Statics to Land Seismic Data: traveltime decomposition vs stack-power maximization (육상 탄성파자료에 대한 나머지 정적보정의 효과: 주행시간 분해기법과 겹쌓기제곱 최대화기법)

  • Sa, Jinhyeon;Woo, Juhwan;Rhee, Chulwoo;Kim, Jisoo
    • Geophysics and Geophysical Exploration
    • /
    • v.19 no.1
    • /
    • pp.11-19
    • /
    • 2016
  • Two representative residual static methods of traveltime decomposition and stack-power maximization are discussed in terms of application to land seismic data. For the model data with synthetic shot/receiver statics (time shift) applied and random noises added, continuities of reflection event are much improved by stack-power maximization method, resulting the derived time-shifts approximately equal to the synthetic statics. Optimal parameters (maximum allowable shift, correlation window, iteration number) for residual statics are effectively chosen with diagnostic displays of CSP (common shot point) stack and CRP (common receiver point) stack as well as CMP gather. In addition to removal of long-wavelength time shift by refraction statics, prior to residual statics, processing steps of f-k filter, predictive deconvolution and time variant spectral whitening are employed to attenuate noises and thereby to minimize the error during the correlation process. The reflectors including horizontal layer of reservoir are more clearly shown in the variable-density section through repicking the velocities after residual statics and inverse NMO correction.

Resolution and Image processing Methods of Tomogram and There impact of Computational Velocity Estimation (토모그램의 해상도와 영상처리 기법이 속도예측에 미치는 영향)

  • Lee, Min-Hui;Song, Da-Hee;Keehm, Young-Seuk
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.147-154
    • /
    • 2009
  • Physical properties of rocks, such as velocity, are strongly dependant on detailed pore structures, and recently, pore micro-structures by X-ray tomography techniques have been used to simulate and understand the physical properties. However, the smoothing effect during the tomographic reconstruction procedure often causes an artifact - overestimating the contact areas between grains. The pore nodes near a grain contact are affected by neighboring grain nodes, and are classified into grain nodes. By this artifact, the pore structure has higher contact areas between grains and thus higher velocity estimation than the true one. To reduce this artifact, we tried two image processing techniques - sharpening filter and neural network classification. Both methods gave noticeable improvement on contact areas between grains visually; however, the estimated velocities showed only incremental improvement. We then tried to change the resolutions of tomogram and quantify its impact on velocity estimation. The estimated velocity from the tomogram with higher spatial resolution was improved significantly, and with around 2 micron spatial resolution, the calculated velocity was very close to the lab measurement. In conclusion, the resolution of pore micro-structure is the most important parameter for accurate estimation of velocity using pore-scale simulation techniques. Also the estimation can be incrementally improved if combined with image processing techniques during the pore-grain classification.

  • PDF

A New Variable Degeneration Resistor for Digitally Programmable CMOS VGA (디지털 방식의 이득조절 기능을 갖는 CMOS VGA를 위한 새로운 가변 축퇴 저항)

  • Kwon, Duck-Ki;Park, Jong-Tae;Yu, Chong-Gun
    • Journal of IKEEE
    • /
    • v.7 no.1 s.12
    • /
    • pp.43-55
    • /
    • 2003
  • A degenerated differential pair has been widely used as a standard topology for digitally programmable CMOS VGAs. A variable degeneration resistor has been implemented using a resistor string or R-2R ladder with MOSFET switches. However, in the VGAs using these conventional methods, low-voltage and high-speed operation is very hard to achieve due to the dc voltage drop over the degeneration resistor. To overcome the problem a new variable degeneration resistor is proposed where the dc voltage drop is almost removed. The proposed gain control scheme makes it easy to implement a low-voltage and high-speed VGA. This paper describes the problems existed in conventional methods, the principle and advantages of the proposed scheme, and their performance comparison in detail. A CMOS VGA cell is designed using the proposed degeneration resistor. The 3dB bandwidths are greater than 650㎒ and the gain errors are less than 0.3dB in a gain control range from -12dB to +12dB in 6dB steps. It consumes 3.1㎃ from a 2.5V supply voltage.

  • PDF

3D Reconstruction of an Indoor Scene Using Depth and Color Images (깊이 및 컬러 영상을 이용한 실내환경의 3D 복원)

  • Kim, Se-Hwan;Woo, Woon-Tack
    • Journal of the HCI Society of Korea
    • /
    • v.1 no.1
    • /
    • pp.53-61
    • /
    • 2006
  • In this paper, we propose a novel method for 3D reconstruction of an indoor scene using a multi-view camera. Until now, numerous disparity estimation algorithms have been developed with their own pros and cons. Thus, we may be given various sorts of depth images. In this paper, we deal with the generation of a 3D surface using several 3D point clouds acquired from a generic multi-view camera. Firstly, a 3D point cloud is estimated based on spatio-temporal property of several 3D point clouds. Secondly, the evaluated 3D point clouds, acquired from two viewpoints, are projected onto the same image plane to find correspondences, and registration is conducted through minimizing errors. Finally, a surface is created by fine-tuning 3D coordinates of point clouds, acquired from several viewpoints. The proposed method reduces the computational complexity by searching for corresponding points in 2D image plane, and is carried out effectively even if the precision of 3D point cloud is relatively low by exploiting the correlation with the neighborhood. Furthermore, it is possible to reconstruct an indoor environment by depth and color images on several position by using the multi-view camera. The reconstructed model can be adopted for interaction with as well as navigation in a virtual environment, and Mediated Reality (MR) applications.

  • PDF

The Accuracy of Master Cast for Implant Prosthesis According to the Types of Impression Tray and Splinting Methods of Impression Copings (인상용 트레이의 종류와 인상용 코핑의 연결고정이 임플랜트 주모형의 정확성에 미치는 영향)

  • Lee, Jee-Hyuk;Choi, Yu-Sung;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.433-445
    • /
    • 2010
  • The aim of this study was to evaluate the fixation effect by connecting impression copings and to compare the three types of impression trays which were used in open tray impression technique. Experimental groups used 3 types of impression trays which are custom tray, plastic metal combination tray and polycarbonate stock tray. These three groups were subdivided into splinted and non-splinted impression copings group. The total number of experimental groups was six. 10 specimens were made for each group. We used 1-screw test, observing the specimen on which only one side abutment of reference framework was fixated with 20 Ncm. The gap between implant analogue and abutment of the other side was observed by stereo microscope. It was measured at 6 points in each specimen. Measuring value was selected when same result was revealed 3 times. Recorded data were statistically analyzed. Whether impression copings were splinted or not, there was no significant difference among custom tray group, plastic metal combination tray group, and polycarbonate stock tray group. Significant statistical difference in vertical fit discrepancy was found between splinted and non-splinted impression copings group with custom tray, plastic metal combination tray and polycarbonate stock tray (p<0.05).