• Title/Summary/Keyword: 오존

Search Result 1,971, Processing Time 0.04 seconds

Effects of Abscisic acid on Ozone Injury in Rice (벼의 오존피해 경감에 미치는 ABA의 효과)

  • 김주령;손태권;조정환;이상철
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.47 no.3
    • /
    • pp.174-185
    • /
    • 2002
  • This study was carried out to investigate the effects or abscisic acid (ABA), three concentrations, on growth, activities of antioxidant-related enzymes and grain yield of two rice plants (Oryza sativa L. cv. Hwamyungbyeo and cv. Namchunbyeo) exposed to ozone (0.150 ppm) for 6 hours a day for 30 days. The leaf chlorop0hyll contents, plant height, and tillering numbers were not shown significant difference. But ABA 10$^{-5}$ M treatment affects to growth slightly. In all concentrations of ABA, superoxide dismutase (SOB) activities were increased at tillering stage of Namchunbyeo which was exposed to ozone. It is considered that the optimum concentration of ABA is 10$^{-5}$ M for minimizing loss of grain yield loss.

The Characteristics of the Ozonizer with Cascade-Type Plate Electrode (Cascade형 평판전극 오존발생기의 특성)

  • Yoon, Dae-Hee;Song, Hyun-Jig;Lee, Sang-Keun;Park, Kwang-Seo;Kim, Jong-Hyun;Park, Won-Zoo;Lee, Kwong-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.5
    • /
    • pp.80-87
    • /
    • 2009
  • Recently, ozone has been utilized in various fields thanks to its effectiveness, and has been in ever-growing demand. Accordingly, various kinds of ozonizers have been examined among researchers. This paper is concerned with developing the cascade-type plate electrode ozonizer(PTO) for improvements of indoor air, water supply and drainage and investigating its characteristics. Four types of ozonizers have been devised according to their size, numbers and arrangement Electric discharge area of each type of ozonizer has the same size of 22,400[$mm^2$], and its discharge power has the maximum 40[w]. As the result of having studied ozone generation ozone concentration and ozone yield characteristics of each ozonizer, we found that the type of ozonizer in which eight plates were arranged into cascade type(PTO-4) was the most excellent one.

Sterilizing Effect of Plant Pathogenic Fungi using Ozone Microbubble (오존마이크로버블을 이용한 식물병원균 살균효과)

  • Kim, Chang Shoo;Yu, Sang Yeol;Lee, Gong In;Kim, Seung Han;Lee, Jong Won;Song, Jae Kwan
    • Journal of Bio-Environment Control
    • /
    • v.23 no.3
    • /
    • pp.250-255
    • /
    • 2014
  • Sterilization is an important factor in reprocessing of drained nutrient solution (RDN). To evaluate the suitability of ozone microbubble for RDN in protected horticulture and plant factory, strong fungicidal activity of ozone and microbubble were applied. This experiment was taken advantage of ozonated water (OW) and ozone gas (OG). The Fusarium oxysporum (FO), Phytophthora capsici (PC) and Colletotrichum gloeosporioides (CG) were treated with OW 0.5, 1.0 and 2.0 ppm and OG $3.0g{\cdot}h^{-1}$ for 0, 30, 60, 120 and 180 sec. Results of this experiment can be summed up as follows : In the OW, FO was sterilized by 0.5 ppm in 60 sec and PC was sterilized by 2.0 ppm in 30 sec. In the OG, FO and PC both of them were sterilized in 180 sec. However, CG was not sterilized using OW and OG. Overall, ozone microbubble showed possibility of sterilization in RDN. However, CG is required to more ozone concentration and processing time.

Characterization of Diethyl Phthalate(DEP) Removal using Ozone, UV, and Ozone/UV Combined Processes (오존, UV, 오존/UV 혼합 공정을 이용한 Diethyl Phthalate(DEP)의 제거특성 연구)

  • Jung, Yeon-Jung;Oh, Byung-Soo;Kang, Joon-Wun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.2
    • /
    • pp.137-143
    • /
    • 2006
  • Three candidate processes(ozone alone, UV alone and ozone/UV combined processes) were evaluated for the removal of diethyl phthalate(DEP). Of the candidates, the ozone/UV process showed the highest removal efficiency of DEP. To elucidate a major oxidant for DEP oxidation in the ozone/UV process, the effects of pH and hydroxyl radical($OH^{\circ}$) scavenger were investigated. As a result, it was found that $OH^{\circ}$ plays a important role for DEP elimination. Meanwhile, the direct reaction between ozone and DEP was negligible. Observing the pseudo first-order rate of DEP removal in ozone alone and ozone/UV processes, the different pattern was obtained from two processes. The ozone/UV process was well plotted following the pseudo first-order. but in the ozone alone process the rate was divided into fast and slow phases. DEP degradation characteristics in ozone alone and ozone/UV was also investigated by observing the HPLC spectrum. We detected unknown compounds that were guessed to DEP byproducts and observed the formation and disappearance of the unknown compounds according to reaction time. Observing of high removal of TOC in ozone/UV combined process, it was found that DEP and DEP byproducts are completely oxidized by ozone/UV combined process.

The Solubility of Ozone in Deionized Water and its Cleaning Efficiency (초순수내에서의 오존의 용해도와 세정효과)

  • Han, Jeoung-Hoon;Park, Jin-Goo;Kwak, Young-Shin
    • Korean Journal of Materials Research
    • /
    • v.8 no.6
    • /
    • pp.532-537
    • /
    • 1998
  • The purpose of this study was to investigate the behavior of ozone in DI water and the reaction with wafers during the semiconductor wet cleaning process. The solubility of ozone in DI water was not only dependent on the temperature but also directly proportional to the input concentration of ozone. The lower the initial ozone concentration and the temperature, the longer the half-life time of ozone. The reaction order of ozone in DI water was calculated to be around 1.5. The redox potential reached a saturation value in 5min and slightly increased as the input ozone concentrations increased. The completely hydrophilic surface was created in Imin when HF etched silicon wafer was cleaned in ozonized DI water containing higher ozone concentrations than 2ppm. Spectroscopic ellipsometry measurements showed that the chemical oxide formed by ozonized DI water was measured to be thicker than that by piranha solution. The wafers contaminated with a non-ionic surfactant were more effectively cleaned in ozonized DI water than in piranha and ozonized piranha solutions.

  • PDF

Variation of Indoor Average Ozone Concentration within the Radiation Therapy Room by High Energy Radiation (고 에너지 방사선에 기인된 방사선치료실 내 평균 오존 농도의 변화)

  • Lee, Jin-kook;Lee, Hyo-Yeong;Im, In-Chul;Yu, Yun-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.171-180
    • /
    • 2016
  • This study was to evaluate the change in characteristics of concentration of ozone after exposure to high energy radiation in linac room. Background ozone concentration of linac room was measured and compared to ozone concentration around linac room. Background ozone concentration of linac room was mean $17.4{\pm}7.9ppb$. It was 50% of the ozone concentration($36.8{\pm}22.3ppb$) around linac room(p<0.05). The concentration of ozone after exposure to high energy radiation in linac room was elevated to double of background ozone level, intensity after exposure. with exposure time concentration of ozone increased proportionally. It showed maximum level at 130~180seconds and slowed a tendency to saturate. It required more than 10 minutes for ozone concentration in linac room to drop to ozone concentration around linac room. The concentration of ozone after exposure to high energy radiation is high enough to cause specific physical symptoms, such as acute dyspnea or chest pain due to dry cough. Exposure to high concentration of ozone in sealed linac room can aggravate pulmonary disease, so special attention is needed.

The Distribution of Total Ozone Amounts and Intercomparison of their characteristics Derived from the TOVS Observations over the Korean Peninsula (TOVS로 부터 도출한 한반도 부근의 전오존량 분포 및 그 특성 비교)

  • 정효상;주상원
    • Korean Journal of Remote Sensing
    • /
    • v.11 no.3
    • /
    • pp.23-31
    • /
    • 1995
  • The International TOVS(TIROS Operational Vertical Sounders) Process Package(ITPP-VI), which has been installed at Korea Meteorological Administration(KMA), is only for a global usage to need a surface data to generate atmospheric soundings and total ozone amount. If the initial input process in the ITTP-VI is not modified, it takes climatic surface data for producing sounding data and total ozone amount in general. KMA is trying to improve the quality of TOVS total ozone amount using real-time synoptoc observation in various ways instead of climatological data because this retrieved data in the new scheme for total ozone presently used at the KMA may critically provide to analyze the long-term trend of ozone structure over the Korean peninsula. Two cases in this study show that TOVS retrieved total ozone amounts used by synoptic surface observations can delineate more detailed ozone structures rather than those used by climate surface data. The distribution of TOVS retrieved ozone amount fields with the synoptic surface analyzed data(TOVS-GPV) show more in detail relatively than those with the climate data(TOVS-CLIMAT) as expected. In addition, the collocated inter-comparisons of TOVS-GPV with TOVS-CLIMAT, TOMS observations and Dobsometer observations are performed statistically. TOVS-GPV fields with TOMS observations show smaller bias relatively than TOVS-CLIMAT and also reduce the differences.

Discharge and Ozone Generation Characteristics of a Co-axial Cylinder Type Ozonizer in Accordance with Varying Discharge Gap (방전갭 변화에 따른 동축 원통형 오존발생기의 방전특성과 오존생성특성)

  • 이상근;전병준;박용권;이광식;최상태;송현직
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.6
    • /
    • pp.103-110
    • /
    • 2001
  • Recently, ozone is utilized in various fields and its needs are expanding. Therefore, so many ozone generation methods have been reported in the last year, its main purpose is to get the high ozone concentration and to improve the ozone yield one of them is a Co-axial cylinder-type ozonizer. In this paper, a new ozonizer, which is using radio-frequency power supply, is fabricated to investigate discharge characteristics and ozone generation characteristics in accordance wish variation of grip spacing of electrodes.

  • PDF

The Removal of Natural Organic Matter and Disinfection By-Product Precursor by Ozone (오존처리에 의한 천연유기물질 변화 및 염소 소독부산물 전구물질 제어)

  • Son, Hee-Jong;Roh, Jae-Soon;Kim, Sang-Goo;Kang, Lim-Seok;Lee, Yong-Doo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.10
    • /
    • pp.1099-1107
    • /
    • 2005
  • The purpose of this study was to find the transformation of organic matter as well as chlorine by product formation potential with ozone dosage. The removal percents of $UV_{254}$ and DOC were $23%{\sim}65%$ and $2%{\sim}15%$ and THMFP and HAAFP were $17%{\sim}52%$ and $9%{\sim}29%$ respectively at $0.5{\sim}3\;mgO_3/mgDOC$ ozone dosage. The hydrophobic and transphobic organic matter were reduced to $37%{\sim}68%$ and $35%{\sim}64%$, on the other hand the hydrophilir organic matter was increased to $40%{\sim}49%$ at $0.5{\sim}3\;mgO_3/mgDOC$ ozone dosage. The produced THMFP and HAAFP from the hydrophobic and transphilic organic matter were decreased greatly with increasing ozone dosage but these by products were increased in the hydrophilic matter. The produced THMFP and HAAFP per unit DOC were decreased and reactivity was reduced greatly with increasing crone dosage. The removal rate of THMFP per unit DOC was much higher than HAAFP by ozone treatment. The Br-THMFP per unit DOC was much more removed than chloroformFP per unit DOC with increasing ozone dosage. and The removal rate of TCAAFP per unit DOC was increased with increasing ozone dosage but TCAAFP was not affected by ozone treatment. Br-HAAFP was decreased at $1\;mgO_3/mgDOC$ ozone dosage but was not more removed above $1\;mgO_3/mgDOC$ ozone dosage. Br-HAAFP had lower removal effect than Br-THMFP by ozone treatment. The optimal ozone dosage can be determined about $1\;mgO_3/mgDOC$ by considering both disinfection by product formation and economical efficiency.

The Effects of Electrodeposited Lead Dioxide Structure on the Ozone Evolution (전착이산화납 결정구조가 전해에 의한 오존발생에 미치는 영향)

  • Kim, In Hwan;Lee, Choong Young;Nam, Chong Woo
    • Applied Chemistry for Engineering
    • /
    • v.7 no.2
    • /
    • pp.280-288
    • /
    • 1996
  • In the ozone evolution using $PbO_2$, which was electrodeposited on Ti plate at various conditions in electrolyte, the effects of lead dioxide structure on the current efficiency and surface structure changes of lead dioxide were investigated. Also the effects of oxygen transfer reaction on the ozone evolution were investigated by means of a $PbO_2$ electrodeposited on the platinum rotating disk electrode. In order to develope an electrode for ozone evolution, durability of lead dioxide and optimum current density were investigated. At the electrodeposited lead dioxide with the larger grain size and higher crystallinity, the efficiency for ozone evolution was higher. Optimum current density to electrodeposite lead dioxide with large grain size and high crystalinity was $50mA/cm^2$. Lead dioxide deposited in the presence of glycerin showed the best advantage of ozone evolution. Also lead dioxide electrodeposited at less than $10mA/cm^2$ or at more than $100mA/cm^2$ has poor performance of ozone evolution and poor adhesive strength to substrate. In the beginning of ozone evolution, surface structure of lead dioxide was changed and this change resulted in good effects on ozone evolution. Lead dioxide doped with other elements was favorable not to ozone evolution but to oxygen evolution, so it is speculated that ozone evolution has not intermediate stage of oxygen evolution and occurs competitively with oxygen evolution. When ozone was evolved at $0.7{\sim}0.8A/cm^2$, the current efficiency was highest.

  • PDF