• Title/Summary/Keyword: 오존제거

Search Result 307, Processing Time 0.025 seconds

A Study on the High Efficiency PR Strip technology by using the Ozone Process (오존공정을 이용한 고효율 PR 제거기술 연구)

  • Son, Young-Su
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.1
    • /
    • pp.22-27
    • /
    • 2007
  • we have been studied on the realization of the boundary layer controlled ozone process and related facilities in order to apply for the photo-resist strip process in the semiconductor and flat panel display manufacturing. By means of developing the technology for the high concentration ozone production, it was possible to realized the boundary layer control ozone process by vapor. As a result of the silicon wafer PR strip test, we obtained the strip rate of about 400nm/min at the ozone concentration of 16wt% and flow rate of 8[liter/min.].

환경관련 특허동향 - 화장실의 중수도 시스템(해성엔지니어링)

  • 한국환경기술인연합회
    • Environmental engineer
    • /
    • s.328
    • /
    • pp.92-96
    • /
    • 2013
  • 본 발명은 화장실의 세면대에서 사용된 세척수 및 하수를 중수도 수질기준에 적합하도록 처리하여 화장실 용수로 재활용하는 화장실의 중수도 시스템에 관한 것이다. 화장실의 중수도 시스템의 구성을 살펴보면, 세면대에서 사용된 세척수 및 하수가 유입되는 반응조와, 상기 반응조로 유입된 세척수 및 하수를 살균 및 소독하는 마이크로버블 오존 발생장치와, 살균 및 소독된 처리수를 정장하는 처리수조와, 상기 처리수조에 저장된 처리수를 화장실 용수로 공급하는 용수공급펌프를 포함한다. 이 중에서 상기 마이크로버블 오존 발생장치는, 외부에서 유입된 공기를 정화하는 에어필터와, 상기 에어필터에서 정화된 공기를 공급하는 에어펌프와, 상기 에어펌프를 통해 유입된 공기에 자외선을 조사하여 오존을 발생시키는 오존발생기와, 상기 오존발생기에서 발생된 오존을 세척수 및 하수에 혼합시키는 기액혼합펌프와 상기 오존과 상기 세척수 및 상기 하수의 혼합 효과를 극대화하기 위한 라인믹서로 구성된다. 이와 같이 구성된 본 발명에 의한 화장실의 중수도 시스템은 상수(上水)의 소비량을 줄이고 하수(下水)의 발생량을 감소시켜 경비절감의 효과를 얻을 수 있고, 지하수의 고갈 및 생활용수의 증가에 따른 물 부족 현상에 대해 능동적으로 대처할 수 있다. 특히, 재활용된 화장실 용수에는 오존이 함유되어 화장실 내의 악취제거, 살균 및 소독효과가 있으며, 외부로 배출되는 세척수 및 하수에 포함된 유지성분을 제거하여 환경오염을 방지할 수 있다.

  • PDF

Study on the Removal of Pharmaceuticals and Personal Care Products and Microorganism Inactivation by Ozonation (오존처리에 의한 의약품류의 제거와 미생물의 불활성화에 대한 연구 및 고찰)

  • Kim, Il-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.12
    • /
    • pp.1134-1140
    • /
    • 2010
  • Ozonation is a promising process that can effectively reduce the occurrence of micropollutants and pathogen in water. This study investigated the performance of ozonation for the removal of pharmaceuticals and personal care products (PPCPs) in secondary effluent from wastewater treatment plant. Moreover, the disinfection potential of ozonation applied for PPCPs removal was discussed. Secondary effluent filtered by sand filter was used for tested water, and ozonation was performed under 2, 4 and 6 mg/L of ozone doses. As a result, 6 mg/L of ozone dose (ozone consumption : 4.4 mg/L) was essential for the effective removal of 37 PPCPs in tested water. Several previous studies showed that the operation condition could achieve approximately 3 log inactivation of total coliform and enteroviruses. On the other hand, dissolved ozone concentration in tested water increased by 1.8 mg/L under 6 mg/L of ozone dose, probably resulting in the increase of bromate formation potential. This result implies that as alternatives to suppress the bromate formation potential during the oxidation of PPCPs by ozone, investigations on advanced oxidation processes are required.

Removal of COD and Color from Anaerobic Digestion Effluent of Livestock Wastewater by Advanced Oxidation Using Microbubbled Ozone (마이크로버블 오존 고도산화를 이용한 축산폐수 혐기소화 배출수의 COD와 색도의 제거)

  • Lee, Inkyu;Lee, Eunyoung;Lee, Hyejung;Lee, Kisay
    • Applied Chemistry for Engineering
    • /
    • v.22 no.6
    • /
    • pp.617-622
    • /
    • 2011
  • Ozone-based advanced oxidation was applied for the treatment of anaerobic digestion effluent of livestock wastewater. Initial COD and color value were 930 mg/L and 0.04, respectively, and the 1/10-diluted wastewater was used for the study. The treatment characteristics were compared between the conventionally generated ozone ($105{\mu}m$) and microbubbled ozone ($13{\mu}m$). The use of microbubbled ozone improved the removal of chemical oxygen demand (COD) and color by 85% and 26%, respectively, compared with the conventionally bubbled ozone. The application of microbubbled $O_3/UV$, $O_3/H_2O_2$, $O_3/UV/H_2O_2$ combinations resulted in 5~10% higher color removal than ozone alone, which implies that the contribution of UV or $H_2O_2$ is not significant in color removal. On the other hand, COD removal could be increased two folds compared with ozone alone through $O_3/UV/H_2O_2$ combination. The contribution of $H_2O_2$ was bigger than UV for COD removal with microbubbled ozone. Due to the enhancement of dissolved ozone and radical activity, the microbubbling enabled us to additional COD removal even after stopping ozone supply in the presence of UV or $H_2O_2$.

The Antibiotic Resistant Gene Pollutant Controls using Chlorine or Ozone disinfection (염소 또는 오존을 이용한 항생제 내성 유전오염물질 제어)

  • Kim, Sung-Pyo;Rhu, Dae-Whan;Oh, Jun-Sik;Cho, Yun-Chul
    • Journal of Wetlands Research
    • /
    • v.13 no.3
    • /
    • pp.697-705
    • /
    • 2011
  • The aim of this study was to examine ozonation disinfection efficiency for Escherichia coli DH5alpha removal, containing the multi-resistance plasmid pB10 as well as chlorination disinfection efficiency. In addition, plasmid pB10 removal rates were estimated by ozonation and chlorination. The removal efficiency of pB10 via ozonation was about 2 to 4 times higher than chlorination. High removal efficiency of pB10 is likely due to OH radical produced during ozonation. These results suggest that integration of advanced oxidation process such as ozonation (or photocatalytic oxidation) with conventional disinfection such as chlorination may be needed for effective control of antibiotic resistant bacteria and genetic materials.

Ozone Generation and NO Gas Removal Characteristics a Silent-Surface Hybrid Discharge Type Ozonizer (무성-연면 복합방전형 오존발생기의 오존생성 및 NO 가스 제거특성)

  • Song, Hyun-Jig;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.7
    • /
    • pp.32-38
    • /
    • 2005
  • A hybrid discharge type ozonizer, which is superposed silent and surface discharges, has been designed and manufactured to apply for Nitrogen Oxides(NO) gas removal. The ozonizer consists of three electrodes, and is classified three types of ozonizer by changing applied voltage. Investigation was carried out variance with the flow rate of supplied oxygen gas, discharge power and the sorts of superposed discharge type ozonizer. Moreover, NO(1200[ppm])/$N_2$ gas removal investigation was also conducted to apply for environment improvement field. Two kinds of NO gas removal investigations were conducted. It distinguishes the investigations into NO gas reaction method. According to these studies, maximum removal rate of 100[%] in NO gas was obtained, and 8334[ppm] and 3249[mg/h] of maximum ozone concentration and generation were also obtained respectively.

VOC 제거를 위한 상압플라즈마 발생장치 개발

  • Choe, Seong-Chang
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.553-553
    • /
    • 2013
  • 상압 플라즈마 기술은 표면처리, 온존 발생장치, VOC (Volatile Organic compound) 제거등 다양한 산업분야에서 응용되고 있다. 상압플라즈마 기술 또한 DBD (Dielectric barrier discharge), Griding Arc, SDIP (Surface Discharge Induced Plasma) 등 다양한 기술들이 개발되어져 왔다. VOC를 제거하기 위한 다양한 플라즈마 기술중 특히 BDB 방법과 SDIP 기술들은 플라즈마에 의한 VOC 분해 뿐만 아니라 오존 발생을 통하여 VOC성분을 분해하는 것으로 알려져 있으며 효율이 매우 뛰어난 것으로 보고 되고 있다. 그러나 BDB 방전의 경우 방전이 발생하는 간격이 매우 작아 공기를 정화시키기 위해 좁은 유로를 통하여 일정넓이를 이동하여하 하기 때문에 압력감소가 심하며 이를 개선하기위해 다단으로 설계할 경우 구조가 복잡하고 가격이 고가인 단점이 있다. 본 연구에서는 두 개의 면 전극이 마주보는 형태로 된 DBD 구조의 단점을 보완하기 위하여 빗살무늬 모양의 다층구조의 선형전극으로 구조를 변화시켜 전극에 의한 압력감소를 방지하고 효율적으로 플라즈마 및 오존을 발생시킬 수 있는 VOC제거용 상압 플라즈마 발생장치를 개발하였다. 또한 플라즈마 발생 및 오존발생량이 우수한 것으로 알려져 있는 SDIP 장치 또한 제작하여 비교 평가를 하였다. 제작된 플라즈마 발생장치는 60 Hz와 20kHz의 교류 고압파워 서플라이를 이용하여 플라즈마 발생실험을 진행하였다. 선행 연구에서는 60 Hz의 고압 파워 서플라이를 이용하여도 플라즈마 방전이 잘 된다고 보고되었는데 본 실험에서 60 Hz 파워 서플라이를 사용할 경우 15 kV 이상이 인가될 때 아주 약하게 오존이 발생하는 현상이 관찰되었으나 육안으로 구분이 될 만큼의 플라즈마 방전은 발생하지 않았다. 20kHz의 고압파워 서플라이를 사용한 경우에는 비교적 낮은 전압인 7 kV에서 방전이 관찰되었으며 분당 22 mg의 오존이 발생하였다. SDIP를 이용한 경우 플라즈마가 발생하는 조건은 SDIP의 기하학적 형상에 많이 의존하게 된다. 본 실험에 SDIP 장치는 매우 낮은 전압에서 방전을 시작하였다. 기존의 DBD와는 다르게 1.7 kV에서 플라즈마 발생하였으며 1.8 kV에서 정상적인 플라즈마 방전이 발생하였다. 이때 분당 3.1 mg의 오존이 발생하였다. 오존 발생양은 앞에 빗살형 플라즈마 방전장치에 비하여 낮은데 인가되는 전력을 고려하면 입력된 전기 에너지당 오존발생양은 비슷한 수준이였다.

  • PDF

전처리공정이 천연유기물질의 움집에 미치는 영향

  • 이주영;이석모
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 1997.10a
    • /
    • pp.67-67
    • /
    • 1997
  • 정수공정은 "원수 -1 침사지 1 전염소 -1 전오존 -1 침전지 1 여과지 1 후오존 1 GAC 4 후염소 1 가정수"로 이루어져 있으며 전처리 공정으로 염 소와 오존을 주입하게 되는데, 여기서 전염소 처리 공정으로 인해 잔류 유리염 소가 수중의 유기물질과 반웅하여 유해성 유기염소 화합물 (i.e.. Trihalomethane, Haloacetonitriles, Chlorophenol 등)을 생성하는 것으로 알려져 있다. 이러한 이유로 고도 정수처리 공정에서는 강한 산화력을 지닌 대체 산화 제로서 오존을 이용하고 있다. 전오존 처리공정은 OOC와 탁도 제거에 있어 응 집제 주입량을 감소시키는 것과 더불어 전오존 효과 (산화, 생분해 증대, 살균 등)를 얻을 수 있는 것으로 알려져 왔다. 그러나 낙동강과 같이 유기물이 많은 원수에 과다한 오존이 주입되면 수중 의 유기물이 저분자화 또는 응집이 어려운 오존 산화물로 변화하여 응집제의 소비가 많아지게 된다. 실제, 오존을 응집 효과에 대해서 pilot plant로 운전한 결과 전오존에 의해 입자성 물질의 제거 효율은 향상된 반면에 유기물 제거는 뚜렷한 효과를 볼 수 없었다고 보고되었다 (류, 1997). 본 연구에서는 물금 지역의 원수와 응집-침전 공정까지 거치는 각각의 처 리수에 대해서 전처리가 응집에 미치는 영향을 천연유기물질 (NOM)의 조성 변화로 파악하였다. 그 방법으로 천연유기물질 (NOM)을 XAD-1, -4 수지를 이 용하여 소수성 물질 (hydrophobic components)과 친수성 물질 (hydrophilic components)로 분리 및 농축하여 용존 유기물이 처리 과정에서 어떻게 변화하 는지를 조사하여 개선된 상수 처리 시스템을 설계하는데 기초 자료를 제공하고 수질 관리 분야에서도 적용하고자 하였다. 상수원수인 물금 지역의 소수성 물질(hydrophobic components)은 75~80%, 친수성 물질(hydrophilic components)은 30~33%정도의 분포를 보였고, 전염소 및 전오존 공정을 거친 처리수에서는 각각 62.2-62.8%, 43.9~49.0% 및 50~ 55%, 40~57% 정도의 분포를 보였다. 그리고 웅집-침전을 거친 처리수에서는 그 분포가 77~82%, 24-48%였다. 전주리 공정을 통하여 소수성 물질(byoghobic components)의 분포가 감 소하는 것을 볼 때 전염소 및 전오존 처리가 용존유기물의 응집에는 오히려 역 효과를 나타내는 것으로 판단된다. 것으로 판단된다.

  • PDF

오존 전처리 공정이 생물활성탄 공정의 효율에 미치는 영향

  • Lee, Sang-Hun;Mun, Sun-Sik;Sin, Jong-Cheol;Choe, Gwang-Geun;Park, Dae-Won;Sim, Sang-Jun;Lee, Jin-Won
    • 한국생물공학회:학술대회논문집
    • /
    • 2002.04a
    • /
    • pp.361-364
    • /
    • 2002
  • BAC (biological activated carbon) process is a combination of biodegradation and active carbon adsorption. Pre-ozonation of raw water increased in biodegradable organic fraction. This study is to investigate the enhancement of dissolved organic matter removals by pre-ozonation process combined with BAC process at a semi-pilot scale. By biodegradation improvement in pre-ozonation process. the charge of adsorption was reduced and the life of biological activated carbon is extended. And, 48 % of total DOC was remove in the upper compartment of BAC column. The removal of the nitrogen-ammonia shows a considerably high removal ratio with 75.9 %.

  • PDF

Characteristics of Discharge Lamp Type Ozonizer for Environment Improvement (환경개선용 방전관형 오존발생기의 특성)

  • Song, Hyun-Jig;Lee, Dong-Heon;Oh, Jin-Hun
    • Proceedings of the KIEE Conference
    • /
    • 2001.07e
    • /
    • pp.24-26
    • /
    • 2001
  • 대기환경오염물질인 NO가스의 제거를 위하여 방전관을 채용한 3전극-2갭 방식의 새로운 형태의 오존발생기를 설계 제작하였다. 본 논문에서는 원료가스의 유량, 방전전력 및 오존발생기의 사용 개수 변화에 따른 방전특성과 오존생성특성을 연구 검토하였으며, 오존발생기로부터 생성된 오존을 NO가스에 접촉시켰을 때 NO 제거특성이 우수하여 방전관형 오존발생기가 대기환경개선 설비로 적용 가능함을 확인하였다.

  • PDF