• Title/Summary/Keyword: 오염된 공기

Search Result 883, Processing Time 0.025 seconds

The Consideration about Heavy Metal Contamination of Room and Worker in a Workshop (공작실에서 실내 및 작업종사자의 중금속 오염도에 관한 고찰)

  • Kim Jeong-Ho;Kim Gha-Jung;Kim Sung-Ki;Bea Suk-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.87-94
    • /
    • 2005
  • Purpose : Heavy metal use when producing the block from the workshop. At this time, production of heavy metal dust and fume gives risk in human. This like heavy metal to improve seriousness through measurement and analysis. And by the quest in solution is purpose of this thesis. Materials and Methods : Organization is Inductively Coupled Plasma Atomic Emission Spectrometer, and the object is Deajeon city 4 workshops in university hospital radiation oncology (Bismuth, Lead, Tin and cadmium). Method is the ppb the pumping it does at unit, comparison analysis. And the Calculation heavy metal standard level in air through heavy metal standard level in body and blood, so Heavy metal temporary standard set. Results : Subterranean existence room air quality the administration laws appointed Lead and Cadmium's exposure recommend that it is $3{\mu}g/m^3\;and\;2{\mu}g/m^3$. And Bismuth and Tin decides $7{\mu}g/m^3\;and\;6{\mu}g/m^3$ through standard level in air heavy metal and standard level in body and blood. Heavy metal measurement level of workshops in 4 university hospital Daejeon city compares with work existence and nonexistence. On work nonexistence almost measurement level is below the recommend level. But work existence case express high level. Also consequently in composition ratio of the block is continuous with the detection ratio. Conclusion : Worker's heavy metal contamination imbrued serious for solution founds basic part. In hospital may operation on local air exhauster and periodical efficiency check, protector offer, et al. And worker have a correct understanding part of heavy metal contamination, and have continuous interest, health control. Finally, learned society sphere administer to establishment standard level and periodical measurement. And it founds basic solution plan of periodical special health checkup.

  • PDF

DISTRIBUTION OF AIRBORNE BACTERIA BY HANDPIECE AEROSOL CONDITIO (핸드피스 분무조건에 따른 부유세균 기균(氣菌) 의 분포)

  • Ko, Young-Han;Baik, Byeong-Ju;Kim, Jae-Gon;Yang, Yeon-Mi;Shin, Jeong-Geun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.4
    • /
    • pp.628-634
    • /
    • 2008
  • In recent years, cross-contamination has become one of the noticeable issues in dental clinic. Two major routes of contamination are the direct-contamination through blood and oral secretion and the indirect-contamination through dental office equipments. Especially, air-contamination through air-floating pollutant in a confined space like hospital, and also contamination through aerosol ejected from high-speed handpiece in a dental office was interested. The purpose of this study was to understand risk of bacterial infection through aerosol from handpiece in a dental office, which will help the practitioner with prevention of contamination during dental treatment. The main findings are as follows. 1. In a comparative test, the group using handpiece has higher bacterial number than the group not using handpiece with significant statistical difference(P<0.01). 2. The group using handpiece with rubber dam has lower bacterial number than the group using handpiecewithout rubber dam with significant statistical difference(P<0.01). 3. Comparing the group using drainage water with the group using distilled water as a handpiece water source results in 22.4 cfu and 17.0 cfu respectively but the difference is no statistically significant(P>0.05). 4. Measuring cfu at 0.5m and 1.5m distance, 0.5m distance showed higher bacterial number with statistical significance(P<0.01). 5. Classification of bacterial types showed the largest bacterial number came from gram-positive micrococcus(73.9%), and gram-negative micrococcus, gram-negative bacillus, and gram-positive bacillus follow in descending order.

  • PDF

Stabilizing Soil Moisture and Indoor Air Quality Purification in a Wall-typed Botanical Biofiltration System Controlled by Humidifying Cycle (가습 주기에 따른 벽면형 식물바이오필터의 토양 수분 안정화 및 실내공기질 정화)

  • Lee, Chang Hee;Choi, Bom;Chun, Man Young
    • Horticultural Science & Technology
    • /
    • v.33 no.4
    • /
    • pp.605-617
    • /
    • 2015
  • The ultimate goal of this research is to develop a botanical biofiltration system that combines a green interior, biofiltering, and automatic irrigation to purify indoor air pollutants according to indoor space and the size of biofilter. This study was performed to compare the stability of air flow characteristics and removal efficiency (RE) of fine dust within a wall-typed (vertical) botanical biofilter depending on humidifying cycle and to investigate RE of volatile organic compounds (VOCs) by the biofilter. The biofilter used in this experiment was designed as an integral form of water metering pump, water tank, blower, humidifier, and multi-level planting space in order to be suitable for indoor space utilization. As a result, relative humidity, air temperature, and soil moisture content (SMC) within the biofilter showed stable values regardless of three different humidifying cycles operated by the metering pump. In particular, SMCs were consistently maintained in the range of 27.1-29.7% during all humidifying cycles; moreover, a humidifying cycle of operating for 15 min and pausing for 45 min showed the best horizontal linear regression (y = 0.0008x + 29.09) on SMC ($29.0{\pm}0.2%$) during 120 hour. REs for number of fine dust (PM10) and ultra-fine dust (PM2.5) particles passed through the biofilter were in the range of 82.7-89.7% and 65.4-73.0%, respectively. RE for weight of PM10 passed through the biofilter was in the range of 58.1-78.9%, depending on humidifying cycle. REs of xylene, ethyl benzene, total VOCs (TVOCs), and toluene passed through the biofilter were in the range of 71.3-75.5%, while REs of benzene and formaldehyde (HCHO) passed through the biofilter were 39.7% and 44.9%, respectively. Hence, it was confirmed that the wall-typed botanical biofilter suitable for indoor plants was very effective for indoor air purification.

Radon concentration measurement at general house in Pusan area (부산지역 일반주택에서의 라돈농도측정)

  • Im, In-Cheol
    • Journal of radiological science and technology
    • /
    • v.27 no.2
    • /
    • pp.29-33
    • /
    • 2004
  • Until early 1980s we have lived without thinking that radon ruins our health. But, scientists knew truth that radon radioactive danger is bedeviling on indoor that we live for a long time. Specially, interest about effect that get in danger and injury for Radon and human body is inactive in our country. Recently, with awareness for Radon contamination, We inform about importance and danger of Radon in some station of the Seoul subway, indoor air of school facilities and We had interest with measure and manages. Usually, Radon gas emitted in base of building enters into indoor through building floor split windage back among radon or indoor air of radon daughter nucleus contamination is increased. Therefore, indoor radon concentration rises as there are a lot of windages between number pipe of top and bottom and base that enter crack from estrangement of the done building floor, underground to indoor. Thus, Radon enters into indoor through architecture resources water as well as, kitchen natural gas for choice etc., but more than about 85% from earth's crust emit. Danger and injury of health by Radon and Radon daughter nucleus that is indicated for cause of lung cancer incerases content of uranium of soil rises specially from inside pit of High area and a mine, cave, hermetical space with house. Safe sub-officer of radon concentration can not know and danger always exists large or small during. So, Important thing reduces danger of lung cancer by lowering concentration of Radon within house and building. Therefore, is thought that need general house Radon concentration measurement, measured Radon concentration monthly using Sintillator radon monitor. Study finding appeared high all underground market 1 year than the ground, and the winter appeared high than the summer. Specially, month that pass over 4pCi in house that United States Environmental Protection Agency advises appeared in underground, and appeared and know Radon exposure gravity by 4 months during 12 months. Therefore, Thinking that establishment and regulation of norm and preparation of reduction countermeasure about Radon are pressing feels, and inform result that measure Radon concentration.

  • PDF

Analysis of Effect on Pesticide Drift Reduction of Prevention Plants Using Spray Drift Tunnel (비산 챔버를 활용한 차단 식물의 비산 저감 효과 분석)

  • Jinseon Park;Se-Yeon Lee;Lak-Yeong Choi;Se-woon Hong
    • Journal of Bio-Environment Control
    • /
    • v.32 no.2
    • /
    • pp.106-114
    • /
    • 2023
  • With rising concerns about pesticide spray drift by aerial application, this study attempt to evaluate aerodynamic property and collection efficiency of spray drift according to the leaf area index (LAI) of crop for preventing undesirable pesticide contamination by the spray-drift tunnel experiment. The collection efficiency of the plant with 'Low' LAI was measured at 16.13% at a wind speed of 1 m·s-1. As the wind speed increased to 2 m·s-1, the collection efficiency of plant with the same LAI level increased 1.80 times higher to 29.06%. For the 'Medium' level LAI, the collection efficiency was 24.42% and 43.06% at wind speed of 1 m·s-1 and 2 m·s-1, respectively. For the 'High' level LAI, it also increased 1.24 times higher as the wind speed increased. The measured results indicated that the collection of spray droplets by leaves were increased with LAI and wind speed. This also implied that dense leaves would have more advantages for preventing the drift of airborne spray droplets. Aerodynamic properties also tended to increase as the LAI increased, and the regression analysis of quadric equation and power law equation showed high explanatory of 0.96-0.99.

Detection and Measurement of Nuclear Medicine Workers' Internal Radioactive Contamination (핵의학과 종사자의 방사성동위원소 체내오염 측정)

  • Jeong, Gyu-Hwan;Kim, Yong-Jae;Jang, Jeong-Chan;Lee, Jai-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.123-131
    • /
    • 2009
  • Purpose: We tested a sample of nuclear medicine workers at Korean healthcare institutions for internal contamination with radioactive isotopes, measuring concentrations and evaluating doses of individual exposure. Materials and Methods: The detection and measurement was performed on urine samples collected from 25 nuclear medicine workers at three large hospitals located in Seoul. Urine samples were collected once a week, 100~200 mL samples were gathered up to 6~10 times weekly. A high-purity germanium detector was used to measure gamma radiations in urine samples for the presence of radioactive isotopes. Based on the detection results, we estimated the amounts of intake and committed effective doses using IMBA software. In cases where committed effective doses could not be adequately evaluated with IMBA software, we estimated individual committed effective doses for radionuclides with a very short half life such as $^{99m}Tc$ and $^{123}I$, using the methods recommended by International Atomic Energy Agency. Results: Radionuclides detected through the analysis of urine samples included $^{99m}Tc$, $^{123}I$, $^{131}I$ and $^{201}Tl$, as well as $^{18}F$, a nuclide used in Positron Emission Tomography examinations. The committed effective doses, calculated based on the radionuclide concentrations in urine samples, ranged from 0 to 5 mSv, but were, in the majority of cases, less than 1 mSv. The committed effective dose exceeded 1 mSv in three of the samples, and all three were workers directly handling radioactive sources. No nurses were found to have a committed effective dose in excess of 1 mSv. Conclusions: To improve the accuracy of results, it may be necessary to conduct a long-term study, performed over a time span wide enough to allow the clear determination of the influence of seasonal factors. A larger sample should also help increase the reliability of results. However, as most Korean nuclear medicine workers are currently not necessary to monitored routinely for internal contamination with radionuclides. Notwithstanding, a continuous effort is recommended to reduce any unnecessary exposure to radioactive substances, even if in inconsequential amounts, by regularly surveying workplace environments and frequently monitoring atmospheric concentrations of radionuclides.

  • PDF

A Study on the Consciousness of the Environment Pollution Problem in Pohang City (환경문제에 관한 시민의식 조사 - 통합후 포항시민을 대상으로 -)

  • Ha, Yeong-Gil;Park, Kyung-Min;Kwon, Young-Sook
    • Journal of agricultural medicine and community health
    • /
    • v.21 no.1
    • /
    • pp.61-73
    • /
    • 1996
  • This study conducted to determine the attitude on environment pollution by Pohang city citizens. 1,059 Pohang city citizens in the age group 20 and over were chosen and surveyed by officials's interview at Up, Myun and Dong during the period 6 September to 20 September 1995. The issue problems to be solved in Pohang city were traffic control 47.3%, environment pollution 22.7%, cultural institutions 11.6%, water service 9.9%, education system 5.1% and community security 2.1%. The 55.1% of subjects responded that responsibility for environment pollution is every citizens duty. The trash from houses were 'garbage'(48.1%), 'waste of life'(21.8%), 'reuse trash'(15.6%) and 'one use thing'(14.5%) in order. The 66.9% of subjects responded that the trash's standard envelopes can be easily tear and its texture is not good. The respondents sometimes or often had experienced foreign bodies, sediment in the water service supply. The 45.9% of the respondents use natural water as drinking water, and the water service supply(26.7%), underground water(17.0%) and buying water(9.3%) were followed. Pertaining to the air pollution(by percent) was pollution of the steel industry complex 78.0%, combustive gas 16.6% and construction dust 1.7%. The respondents at southern district complained of respiratory tract by air pollution and the respondents at northern district complained of the visual disturbance and the offensive odor(P<0.05). Water pollution problem is factory's wastewater 56.2%, home wastewater 36.4% and livestock's wastewater 5.6% in order. The respondents at southern district complained of the noise pollution by airplanes and factories at the afternoon and the respondents at northern district complained of the noise pollution by vehicles(P<0.05).

  • PDF

Performance Evaluation of Bio-Membrane Hybrid Process for Treatment of Food Waste Leachate (음식물 침출수 청정화를 위한 파일롯 규모의 생물-분리막 복합공정의 성능 평가 연구)

  • Lee, Myung-Gu;Park, Chul-Hwan;Lee, Do-Hoon;Kim, Tak-Hyun;Lee, Byung-Hwan;Lee, Jin-Won;Kim, Sang-Yong
    • KSBB Journal
    • /
    • v.23 no.1
    • /
    • pp.90-95
    • /
    • 2008
  • In this study, a combined process of sequential anaerobic-aerobic digestion (SAAD), fluidized-bed bioreactor (FBBR), and ultrafiltration (UF) for the treatment of small scale food waste leachate was developed and evaluated. The SAAD process was tested for performance and stability by subjecting leachate from food waste to a two-phase anaerobic digestion. The main process used FBBR composed of aerators for oxygen supply and fluidization, three 5 ton reaction chambers containing an aerobic mesophilic microorganism immobilized in PE (polyethylene), and a sedimentation chamber. The HRTs (hydraulic retention time) of the combined SAAD-FBBR-UF process were 30, 7, and 1 day, and the operation temperature was set to the optimal one for microbial growth. The pilot process maintained its performance even when the CODcr of input leachate fluctuated largely. During the operation, average CODcr, TKN, TP, and salt of the effluent were 1,207mg/L, 100mg/L, 50 mg/L, and 0.01 %, which corresponded to the removal efficiencies of 99.4%, 98.6%, 89.6%, and 98.5%, respectively. These results show that the developed process is able to manage high concentration leachate from food waste and remove CODcr, TKN, TP, and salt effectively.

Distribution and Characteristics of Heterotrophic Plate Count Bacteria in Water Samples from Drinking Water Dispensers (냉온수기에서 일반세균의 분포 및 분리한 세균의 특성)

  • Lee, Eun-Hwa;Koh, Ji-Yun;Kim, Jong-Seol
    • Korean Journal of Microbiology
    • /
    • v.44 no.3
    • /
    • pp.244-250
    • /
    • 2008
  • To evaluate bacteriological water quality, samples were taken from drinking water dispensers placed at S company (S-C) and U highschool (U-H) in Ulsan. The medians of heterotrophic plate counts (HPCs) were 53 CFU/ml for the 74 water samples of S-C and 80 CFU/ml for the 36 cold water samples of U-H, and 38% of the S-C and 42% of the U-H samples showed HPC bacterial concentrations higher than 100 CFU/ml. Coliform bacteria were detected from one sample of S-C. To determine the major source of bacterial contamination, water samples were taken daily for $6\sim8$ days from the bottled water containers as well as the faucets of an experimental water dispenser. While the average HPCs in the bottled water containers were 33 CFU/ml for the first and 132 CFU/ml for the 2nd analysis, the HPC concentration in the cold water samples was 1,022 CFU/ml for the 2nd analysis. These results suggest that the majority of bacteria detected in the cold water samples were originated from the biofilms on the surface of water passages within the water dispensers. There was no significant increase in HPC bacterial concentrations within the bottled water container after installation on the water dispenser. We could isolate and tentatively identify 3 genera 6 species of Gram-positive and 7 genera 7 species of Gram-negative bacteria from the plate count agar plates of U-H samples. Among the isolates, 72% were observed as Gram-positive, and Micrococcus spp. was the most abundant with 54% of the total, followed by Sphingomonas paucimobilis with 16%. It appears that most of the HPC bacteria detected in water dispensers originate from indoor airborne bacteria, which may play important roles in the formation of biofilms on the surface of water passages within the water dispensers.

Effect of n-3 fatty acid deficiency on fatty acid compositions of nervous system in rats reared by artificial method. (N-3 지방산 결핍이 혈청 및 신경조직의 지방산 조성에 미치는 영향)

  • Lim, Sun-Young
    • Journal of Life Science
    • /
    • v.17 no.5 s.85
    • /
    • pp.634-640
    • /
    • 2007
  • Our previous study suggested that n-3 fatty acid deficiency was associated with significantly reduced spatial learning as assessed by Morris water maze test. Here we investigated an effect of n-3 fatty acid deficiency on rat brain, retina and serum fatty acyl compositions at 15 wks age using a first generational artificial rearing technique. Newborn Rat pups were separated on day 2 and assigned to two artificial rearing groups or a dam-reared control group. Pups were hand fed artificial milk via custom-designed nursing bottles containing either 0.02%(n-3 Deficient) or 3.1% (n-3 Adequate) of total fatty acids as a-linolenic acid(LNA). At day 21, rats were weaned to either n-3 deficient or n-3 adequate pelleted diets and fatty acid compositions of brain, retina and liver were analyzed at 15 wks age. Brain docosahexaenoic acid(DHA) was lower(58% and 61%, P<0.05) in n-3 deficient in comparison to n-3 adequate and dam-reared groups, receptively, while brain docosapentaenoic acid(DPAn-6) was increased in the n-3 deficient group. In retina and serum fatty acid compositions, the decreased precentage of DHA and increased precentage of DPAn-6 were observed. These results suggested that artificial rearing method can be used to produce n-3 fatty acid deficiency in the first generation and that adequate brain DHA levels are required for optimal brain function.