• Title/Summary/Keyword: 오염(contamination)

Search Result 2,354, Processing Time 0.025 seconds

Field Investigation for Identification of Contamination Sources in Petroleum-Contaminated Site (유류로 오염된 부지의 원인자 판단을 위한 현장조사 평가)

  • Park, Jeong Jun;Kim, Sung Hwan
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.2
    • /
    • pp.141-153
    • /
    • 2018
  • Purpose : The subject site selected in this study was a place that was prepared through the reclamation of foreshore completed in 1973. Since then, the site has been occupied by the industry of ship repair for over 30 years. Method : The results of a precise soil examination conducted in 2013 showed that the site was seriously contaminated with TPH over an area of $10,000m^2$ and GL(-)3.0m in depth, with an expanding coverage of contamination. Results : The soil contamination by refined petroleum products often results in adverse effects to human health and ecological systems, thus the contamination should be purified as soon as possible. Conclusion : Hydrogeological investigation can be employed to assess the groundwater movement and propagation of contamination to determine the potential agents or contaminants in the soil contaminated with high concentration TPH.

Survey of Staphylococcus epidermidis Contamination on the Hands of Dental Hygienists and Equipment Surface of Dental Clinics (치과의료기관 의료장비 표면 및 치과위생사 손의 Staphylococcus epidermidis 오염도 조사)

  • Kim, Seol-Hee
    • Journal of dental hygiene science
    • /
    • v.17 no.6
    • /
    • pp.472-480
    • /
    • 2017
  • The purpose of this study was to investigate Staphylococcus epidermidis contamination on hands of 20 dental hygienists and 140 equipment surface of 20 dental clinics in a local area, from July to August 2017. The degree of S. epidermidis contamination was measured using a hand plate and a rodac plate and then cultured at $35^{\circ}C$ for 24 hours. Based on hand plate criteria, hand contamination was classified into low, middle, and high groups. Analysis of the variance (ANOVA) of the contamination level of the hand parts of the group surface contamination level of the dental clinic equipment was descriptive statistics after clustering lock count. S. epidermidis contamination was moderate in 55% of the hands of dental hygienists. The area of contamination was 29.45 colony-forming units (CFU) on the palm, followed by the middle finger 7.8 CFU, ring finger 6.4 CFU, and thumb 6 CFU. Medical equipment surface contamination was showed that 3-way handle 4.45 CFU, computer mouse 3.37 CFU, mirror handle 1.60 CFU were higher than other areas. The group with high hand contamination had a high positive correlation with the S. epidermidis contamination of the hand. S. epidermidis contamination level was higher on hands than on the medical equipment surface contamination. Therefore, medical staff should recognize the importance of hand hygiene which should be practiced in the manner suggested by World Health Organization. In addition, the medical team needs to be responsible for performing infection control tasks, implementing infection management guidelines and providing systematic education on infectious disease management.

Applicability of Resistivity/Capacitance Measurement on CPT Module for Investigation of Subsurface Contamination (지반 오염도 조사를 위한 전기비저항/정전용량 측정콘의 적용성 평가)

  • Oh, Myoung-Hak;Kim, Yong-Sung;Park, Jun-Boum
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.7
    • /
    • pp.45-54
    • /
    • 2006
  • Resistivity cone penetrometer test (RCPT) can be employed at a relatively low cost for in-situ delineation of subsurface contamination. While the resistivity measurement has a potential to investigate the subsurface contamination, resistivity measurements alone will lead to some degree of ambiguity in the results. In this study, capacitance measurement was incorporated into the RCPT to overcome the ambiguity inherent in electrical resistivity measurements. This study is focused on verifying the applicability of resistivity and capacitance measurements of CPT module to provide information on subsurface contaminated by heavy metal and petroleum hydrocarbon. Laboratory model tests were performed to evaluate the sensitivity of the measured resistivity and relative capacitance on the water content and different types of contaminants. Test results show that simultaneous measurement of electrical resistivity and capacitance can give more reliable information on subsurface contamination. Electrical measurements of the CPT module showed high applicability to be used in detecting saturated soils contaminated by heavy metal and diesel plume floating above the groundwater table.

A Study on Countermeasure and Contamination Analysis for Heavy Metal Pollution of Nearby Area using Stony Mountain Field Case (석산개발 사례를 이용한 주변 지역의 중금속 오염분석 및 대책방안에 관한 연구)

  • Han, Jung-Geun;Yoon, Won-Il;Lee, Yang-Kyu;Lee, Jong-Yuong;Hong, Ki-Kwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.9 no.4
    • /
    • pp.57-66
    • /
    • 2010
  • This study is described in heavy metal pollution by the stony mountain development using field case. The heavy metal pollution is investigated for nearby area (soil and stream) of the developed stony mountain, and then the countermeasure using contamination analysis is suggested. The investigation result indicated that contamination of Sammak stream caused by the stone dust and leachate at the stony mountain development. Therefore, the heavy metal pollution is evaluated by using Pollution Index(PI). The evaluation results confirmed that the contaminated groundwater was the leading cause of the contamination in Sammak stream and nearby soil. Therefore, the Permeable Reaction Barrier(PRB), which has a environmentally-friendly reactant, should be applied to control a heavy metal of groundwater, and it will be a reasonable countermeasure.

  • PDF

A Geo-statistical Assessment of Heavy Metal Pollution in the Soil Around a Ship Building Yard in Busan, Korea (통계지표를 활용한 부산지역 조선소 주변 토양 내 중금속 오염조사 연구)

  • Choi, Jung-Sik;Jeon, Soo kyung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.7
    • /
    • pp.907-915
    • /
    • 2018
  • With the increase of metal usage in various industries, metal pollution and ecological toxicity in the environmental system have become a significant concern. A geo-statistical index has been widely used to determine contamination level with normalization through a background value. In this study, geo-statistical indexes such as an enrichment factor, accumulation index, and potential ecological risk index were used to assess metal pollution in soil at locations associated with shipbuilding manufacturing industries. Metal contamination, especially of Cu and Pb, was observed in some samples located closer to manufacturing sites. Enrichment factor and accumulation (IGEO) values were indicative of concerning levels of soil contamination in specific samples, and the soil contamination could be induced by anthropogenic sources. In further study, after more detailed sampling for soil and potential pollution sources, high interpretation techniques such as Pb isotope analysis and X-ray analysis will be needed to investigate source identification.

A Study on Contamination Sensitivity and Condition Monitoring for a Pump (펌프의 오염 민감도와 성능 감시에 대한 연구)

  • 이재천
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.124-130
    • /
    • 1998
  • A mathematical model describing gear pump flow degradation in the presense of abrasive particles is presented. The model considers the operating parameters as Sommerfeld number, so that contamination sensitivity test results could be conversed to field application to predict contamination service life. A method to estimate the volumetric efficiency and the contamination level of a pump is proposed by measuring the temperature differences in the fluid. Test results show the validity of the theoretical establishments.

  • PDF

Microbial contamination in contact lens care systems (Contact lens care system의 미생물 오염)

  • Kim, Sang-Moon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.1 no.1
    • /
    • pp.57-63
    • /
    • 1996
  • The microbial contamination in contact lens care systems and conjunctivas of 40 asymptomatic cosmetic soft contact lens wearers was investigated. Patient ages ranged from 19 to 27(mean:22), most of them have used hydrogel contact lenses for less than 1 year, and the ages of lens cases were 1 weeks ~ 3 months (43 %) or 4~6 months (52%). Twenty-seven patients (67%) chemically disinfected their lenses and 8(20 %) used hydrogen peroxide, and 5 used heat to disinfect. Fourteen patients used commercial non-preserved saline, and 26(65%) were using commercial preserved saline. Sixty-two percent of the patients had bacterial contamination of lens case, and 17% had conjunctival contamination. The bacterial contamination rate was highest in lens cases, followed by unpreserved salines, disinfecting chemicals(non-hydrogen peroxide), and conjunctivas. The fungal contamination rate of cases and conjunctivas was 67% and 15%, respectively, and lens case, unpreserved saline, and conjunctiva seemed more susceptible to contamination. The use of hydrogen peroxide for disinfection rather than chemical disinfection was associated remarkabley with decreased contamination of solution itself, and there was no significant difference in contamination rates between hydrogen peroxide care system and other disinfecting systems. Five of lens cases(13%) and 2 conjunctivas(5%) were contaminated with Pseudomonas aeruginosa, and Candida albicans were isolated from 11cases (27%) and 5 conjunctivas (12%). Of the organisms that were contaminated lens cases and conjunctivas, Pseudomonas aeruginosa, Escherichia coli, Candida albicans, and Aspergillus fumigatus were isolated from lens cases, whereas Pseudomonas aeruginosa, Candida albicans, and Aspergillus fumigatus were recorvered from conjunctivas. Fortunately all of the these tested samples showed 0% of Acanthamoeba in this investigation.

  • PDF

Cleaning and Decontamination Method of Books for Their Sanitary Circulation (책의 위생적 유통관리를 위한 세정 소독 방법)

  • Kim, Nam Yong;An, Duck Soon;Choi, Young Il;Jung, Yong Bae;Kim, Jung Min;Lee, Dong Sun
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.19 no.1
    • /
    • pp.11-15
    • /
    • 2013
  • In order to find a sanitary logistic way to handle library books, papers and environmental sources contacting the books were tested in their microbial contamination load and methods to decontaminate the books were investigated. Generally bacterial load of inner book pages was very low, but increased when contaminated with liquid such as saliva. In contrast, their lateral ends showed much higher bacterial contamination presumably due to dry dust contamination on there. As operations to improve the sanitary book conditions, turbulent air blow was found to be workable for reducing dry dusty contamination and 280 nm ultra-violet (UV) light emitting diode (LED) was so for decontaminating wet surface contamination. Microbial inactivation by the UV LED could be realized with irradiation for more than 5 minutes at 2 cm distance. Air blow of 5.5 m/s for 0.5~1 minute could reduce the dusty contamination on a model book surface.

  • PDF

Iron Ion Contamination and Acid Washing Effect of Polymer Membrane and Electrode in Polymer Electrolyte Fuel Cell (고분자전해질 연료전지에서 고분자 막과 전극의 철 이온 오염 및 산 세척 효과)

  • Yoo, Donggeun;Park, Minjeong;Oh, Sohyeong;Park, Kwon-Pil
    • Korean Chemical Engineering Research
    • /
    • v.60 no.1
    • /
    • pp.20-24
    • /
    • 2022
  • In the process of long-term use of PEMFC (Proton Exchange Membrane Fuel Cells), chemical degradation of membrane electrode assembly (MEA) occurs due to corrosion of stack elements and contamination of supply gas. In this study, we investigated whether chemically degraded MEA can be recovered by acid washing. The performance was measured and compared in a PEMFC cell after contamination with iron ions and washing with an aqueous sulfuric acid solution. The performance was reduced by about 25% by 0.5 ppm iron ion contamination, and 97.1% performance recovery was possible by washing of 0.15 M sulfuric acid. The membrane resistance was increased due to iron ion contamination of the polymer membrane, and the ionic conductivity was restored by washing the iron ions from the membrane while minimizing the loss of the electrode catalyst by washing with a low-concentration sulfuric acid aqueous solution. The possibility of solving the decrease in durability caused by chemical contamination of PEMFC MEA by the acid washing was confirmed.

Sensitivity Analysis of Input Parameters for a Dynamic Food-Chain Model DYNACON (동적섭식경로모델 DYNACON에 대한 입력변수의 민감도분석)

  • Hwang, Won-Tae;Lee, Geun-Chang;Han, Moon-Hee;Cho, Gyu-Seong
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.1
    • /
    • pp.11-19
    • /
    • 2000
  • The sensitivity analysis of input parameters for a dynamic food chain model DYNACON was conducted as a function of deposition date for the long-lived radionuclides $(^{137}Cs,\;^{90}Sr)$. Also, the influence of input parameters for the short and long-terms contamination of selected foodstuffs (cereals, leafy vegetables, milk) was investigated. The input parameters were sampled using the LHS technique, and their sensitivity indices represented as PRCC. The sensitivity index was strongly dependent on contamination period as well as deposition date. In case of deposition during the growing stages of plants, the input parameters associated with contamination by foliar absorption were relatively important in long-term contamination as well as short-term contamination. They were also important in short-term contamination in case of deposition during the non-growing stages. In long-term contamination, the influence of input parameters associated with foliar absorption decreased, while the influence of input parameters associated with root uptake increased. These phenomena were more remarkable in case of the deposition of non-growing stages than growing stages, and in case of $^{90}Sr$ deposition than $^{137}Cs$ deposition. In case of deposition during growing stages of pasture, the input parameters associated with the characteristics of cattle such as feed-milk transfer factor and daily intake rate of cattle were relatively important in contamination of milk.

  • PDF