• Title/Summary/Keyword: 오메가형

Search Result 22, Processing Time 0.026 seconds

Mechanical Evaluation of Posterior Dynamic Omega-wire Stabilization System (후방 요추 극돌기간 유동적 오메가형 스프링 고정재의 역학적 평가)

  • Lee, Yeon-Soo;Song, Geun-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.11
    • /
    • pp.1099-1104
    • /
    • 2012
  • The study investigates the mechanical deformation of a newly developed screwless omega-wire dynamic system for stabilization of the spine. The omega-wire spring stabilization system was tested under tension, compression, and dynamic compressive fatigue loads. In addition, its bending deformation was compared to that of a spiral-wire spring system using FEA. A model whose hanger inter-center distance is 60 mm showed an ultimate tensile stress of 3981.7 N at a displacement of 3.61 mm and an ultimate compressive load of 535.6 N at a displacement of 2.16 mm. Under fatigue loading of 5 Hz with 10 N/1 N, it did not show any failure over 5 million cycles, and the displacement was restricted to 8-9 mm. In the FEA, the omega-wire spring system showed more flexible bending features than did the spiral-wire spring system.

Flexural Capacity and CO2 Reduction Evaluation for Composite Beam with Weight Reducing Steel Wire-Integrated Void Deck Plate slab (자중저감 철선일체형 중공 데크플레이트 슬래브를 사용한 합성보의 휨내력 및 CO2 감소량 평가)

  • Kim, Sang-Seop;Park, Dong-Soo;Boo, Yoon-Seob
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.3
    • /
    • pp.313-323
    • /
    • 2012
  • The purpose of this study is to evaluate $CO_2$ reduction and the flexural performance of steel wire-integrated void deck plate slabs that were inserted in omega-shaped steel plates to reduce concrete and welded H-section beams. The void deck plate slab can secure the structure, not only reducing the weight of the building but it is also eco-friendly. Therefore, this study evaluated the flexural performance of the composite beam by conducting a monotonic loading test with the use of actuators. It quantitatively evaluated the $CO_2$ emission based on earlier studies. The main test parameters are the concrete thickness of upper slabs, and the interrupted width of the omega-shaped steel plate. The result of the test showed that the welded H-section beam applied steel wire-integrated void deck plate slabs that were inserted into the omega-shaped steel plate declined in flexural performance on the composite beam after reducing concrete volume. Likewise, it is effective in reducing $CO_2$.

An Experimental Study on the Vibration and Fire Resistance of Steel Void Deck Plate Slab for Omega-steel plate (오메가형 강판을 중공체로 사용한 데크플레이트 슬래브의 진동 및 내화에 관한 실험적 연구)

  • Kim, Sang-Seup;Ryu, Deog-Su
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.6
    • /
    • pp.705-713
    • /
    • 2011
  • This study was conducted to assess the vibration capacity and the fire resistance capacity of a deck plate slab using an omega steel plate as the void deck plate. First, to evaluate the vibration capacity of the deck plate slab after the insertion of the omega steel plate, three 150mm specimens and three 200mm specimens were made using the slab depth as the main variable. Each specimen consisted of an existing deck plate and two specimens, using the topping depth as the variable according to the slab depth. Second, two real-size specimens were made to evaluate the fire resistance capacity. The results of the test showed that the steel-wire-integrated deck plate slab that was inserted in the omega steel plate did not have a vibration problem due to the void deck plate, because the natural frequency was 12.66-14.09 Hz in the vibration test, and each specimen satisfied the appraisal standards for the load capacity, heat block quality, and chloride inhibition for two hours in the fire resistance test. Consequently, the steel-wire-integrated deck plate slab that was inserted in the omega steel plate can be reduced using the concrete volume and can have higher vibration and fire resistance capacities, similar to the existing deck plate.

비타민,제대로 알고 먹자-오메가3지방산, 오메가6지방산, 비타민E

  • Kim, Hye-Gyeong
    • 건강소식
    • /
    • v.32 no.7
    • /
    • pp.26-27
    • /
    • 2008
  • 미량으로도 성장을 저지시키거나 결핍증을 초래하고, 일부를 제외하고는 체외에서 합성되지 않거나 합성된다 하더라도 필요량을 충족할 수 없어 외부로부터 공급받아야 하는 비타민. 땀을 많이 흘리는 여름은 다른 계절에 비해 체력이 떨어지게 마련인데, 이때 비타민 섭취는 필수. 오메가3지방산과 오메가6지방산, 비타민E에 대해 좀 더 자세히 알아보고, 술과 담배를 좋아하는 남편, 한창 성장하는 아이들, 관절이 좋지 않는 어르신들을 위한 맞춤형 비타민을 준비해보자.

  • PDF

Biochemical mechanism of the ratio of omega 6 to 3 fatty acid on blood lipid reduction in rats (랫드에서 혈액지질 감소에 관한 오메가 6와 3 지방산 비율의 생화학적 메카니즘)

  • Lee, Seung-Hyung;Kim, Jin-Soo;Choi, Du-Hyeong;Kim, Chang-Rae;Um, Kyung-Hwan;Park, Byung-Sung
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.2
    • /
    • pp.315-326
    • /
    • 2017
  • This study was investigated the biochemical mechanism on reducing blood lipids in second-generation rats fed diet with different omega 6 to omega 3 fatty acid ratio. The experiment treatment groups were classified into the groups with the omega 6 to omega 3 ratios of 0 (control group), 1:1, 8:1, and 19:1, respectively. The levels of the blood triglyceride, total cholesterol, low density lipoprotein-cholesterol (LDL-C), aspartate aminotransferase (AST), alanine aminotransferase (ALT) and glucose were lowest in the group with the omega 6 to omega 3 ration of 1:1. The levels of high density lipoprotein-cholesterol and phospholipid were highest in the group with the omega 6 to omega 3 ration of 1:1. The HMG-CoA reductase activity was suppressed in the groups with the omega 6 to omega 3 ratio of 1:1 and 8:1 compared with that in the control group, but the excretion of sterol through feces was promoted. The blood omega 6 to omega 3 ratio decreased in a concentration-dependent manner depending on the increase in the omega 6 to omega 3 ratio within the ingested diet. The results of this study demonstrated a new finding that when the parent generation and second-generation rats ingested the diet with the omega 6 to omega 3 ratio of below 8:1, harmful lipids in the blood were reduced, the liver functions were maintained, and the growth was promoted due to the nutrient metabolism activation mechanism.

Structural Performance Evaluation on Flexural and Shear Capacity for Weight Reducing Steel Wire-Integrated Void Deck Plate Slab (자중저감 철선일체형 중공 데크플레이트 슬래브의 휨 및 전단내력에 대한 구조성능평가)

  • Kim, Sang-Seup;Ryu, Deog-Su;Boo, Yoon-Seob
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.4
    • /
    • pp.411-422
    • /
    • 2012
  • The purpose of this study is to evaluate the flexural and shear capacity of steel wire-integrated void deck plate slabs. In order to evaluate flexural and shear capacity, we make five 150mmspecimens and three 200mmspecimens by slab depth as main variable. Each series of specimen is comprised of an existing steel wire-integrated deck-plate slab and two specimens using topping depth as variable. From the series of experiments, steel wire-integrated void deck plate slabs has any decline in flexural and shear performance. Therefore, a void-deck-plate slab which inserts Omega-steel plate showed reducing a using concrete-volume and had flexural and shear capacity following existing steel wire-integrated deck-plate.

A Study on Structual Analysis of Bellows for Automotive (자동차용 벨로우즈의 구조해석에 관한 연구)

  • Rha Wan Yong;Kim Mi-Soo;Oh Yong Suk
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.6
    • /
    • pp.102-106
    • /
    • 2004
  • The purpose of the study is to perform structual analysis of 9 type bellows for automotive. The bellows joint which was used as a absorber or safety equipment to prevent the deformation or fracture of a structure, has been analyzed by the FEM modeling using axi-symmetric conical frustum element. Using FEM the general behavior of bellows analysis can be investigate easily, as well as the stability of the analysis can be guarantee. The results of finite element structual analysis and actual result gave a good agreement.