• Title/Summary/Keyword: 영향분석

Search Result 65,141, Processing Time 0.092 seconds

INFLUENCE OF IRRADIATION MODES ON THE MICROHARDNESS AND THE POLYMERIZATION CONTRACTION OF COMPOSITE RESIN POLYMERIZED WITH LED CURING UNIT (LED 광중합기의 조사 mode가 복합레진의 미세경도 및 수축응력에 미치는 영향)

  • Park, In-Ho;Oh, You-Hyang;Lee, Nan-Young;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.2
    • /
    • pp.312-320
    • /
    • 2005
  • The purpose of this study was to evaluate the polymerization contraction and the microhardness of compostie resin($Supreme^{(R)}$, Filtek $Flow^{(R)}$, 3M-ESPE, USA) according to irradiation modes of LED curing unit(Elipar $Freelight^{(R)}$, 3M-ESPE, USA). The strain guage method was used for determination of polymerization contraction. Sample were divided by 6 groups according to curing modes and filling method. Group A: $Supreme^{(R)}$, Filtek $Flow^{(R)}$ lining, 10seconds curing, Group B: $Supreme^{(R)}$, Filtek $Flow^{(R)}$ lining, 15seconds curing, Group C: $Supreme^{(R)}$, Filtek $Flow^{(R)}$ lining, 15seconds soft start curing, Group D: $Supreme^{(R)}$ only, 10seconds curing, Group E: $Supreme^{(R)}$ only, 15seconds curing, Group F: $Supreme^{(R)}$ only, 15seconds soft start curing. Preparations of acrylic molds were followed by filling and curing. Strain guage attached to each sample were connected to a strainmeter. Measurements were recorded at each second for the total of 10 minutes including the periods of light application. And microhardness of each group after 24hours from light irradiation were measured. Obtained data were analyzed statistically using Repeated measures ANOVA and Tukey test. The results of the present study are as follows: 1. In flowable resin liner group, soft start curing group was not found decrease of polymerization contraction. But, In Supreme only filling group, the lowest polymeriation contraction was found in soft start curing group. 2. 10 seconds curing group showed statistically significant reduction of polymerization contraction compared with 15 seconds curing group(p<0.05). 3. The microhardness values of each group not revealed significant difference(p>0.05). But, lower surface microhardness was not reached 80% of upper surface microhardness.

  • PDF

EFFECT OF HYDROGEN PEROXIDE CONCENTRATION ON THE WHITENING AND PHYSICAL PROPERTIES OF HYDROXYAPATITE DISCS (Hydrogen Peroxide 농도와 적용시간이 Hydroxyapatite Discs의 미백과 물리적 성질에 미치는 영향)

  • Yang, Yeon-Mi;Lee, Doo-Cheol;Baik, Byeong-Ju;Kim, Jae-Gon;Shin, Jeong-Geun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.1
    • /
    • pp.1-12
    • /
    • 2007
  • The purpose of this study was to evaluate the effect that various concentration and application time of hydrogen peroxide had on tooth whitening and physical properties. The hydroxyapatite (HA) discs of $12mm({\Phi}){\times}1.2mm(t)$ in dimensions were made by compression $(100kg/cm^2)$ and sintering (at $1350^{\circ}C$ for 2 hours) All specimens were polished sequentially with '240 through '2000 emery paper and one side of each specimen was polished finally with $0.3{\mu}m$ alumina paste. The discs were placed in sterile whole stimulated saliva overnight at $37^{\circ}C$ in order to form an in vitro pellicle layer. Then the discs were rinsed with distilled water and soaked into staining broth at $37^{\circ}C$ for 7 days. These stained specimens were bleached with hydrogen peroxide according to the change of concentration $(3{\sim}30%)$ and application time ($3{\sim}10$ days). The specimens were analyzed with a spectrophotometer, X-ray diffractometer (XRD), scanning electron microscope (SEM), surface roughness tester, microhardness tester and biaxial flexural strength. The results of present study can be summarized as follows : 1. The bleaching effect was increased with the increased concentration and the extended application time of hydrogen peroxide. 2. The surface roughness was significantly increased from the specimen bleached with 15% hydrogen peroxide for 10 days and with 30% for 7 and 10 days respectively (p<0.05). 3. The changes of crystal phase observed by XRD between before and after bleaching weren't shown of any difference, but microporous structure of surface observed by SEM was shown of increase with the increased concentration and the extended application. 4. The biaxial flexural strength was significantly decreased from bleaching of specimen with 30% hydrogen peroxide for 7 and 10 days respectively (p<0.05) 5. Microhardness was significantly decreased from bleaching with 15% hydrogen peroxide for 10 days and with 30% for 3, 7 and 10 days respectively (p<0.05). Although the tooth bleaching effect was greater when the high concentration was applied, further in vivo experiment will be needed to prove it's safety.

  • PDF

Review of the Radiation Risk and Clinical Efficacy Associated with Computed Tomography Cancer Screening (암의 조기발견을 위한 CT촬영에서의 임상적 효능과 방사선위해에 대한 고찰)

  • Kim, Hyun Ja
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.214-227
    • /
    • 2013
  • Computed tomographic scan as a screening procedures in asymptomatic individuals has seen a steady increase with the introduction of multiple-raw detector CT scanners. This report provides a brief review of the current controversy surrounding CT cancer screening, with a focus on the radiation induced cancer risks and clinical efficacy. 1. A large study of patients at high risk of lung cancer(the National Lung Screening Trial[NLST]) showed that CT screening reduced cancer deaths by 20%(1.33% in those screened compared with 1.67% in those not screened). The rate of positive screening tests was 24.2% and 96.4% of the positive screening results in the low-dose CT group were false-positive. Radiation induced lung cancer risk was estimated the most important in screening population because ERR of radiation induced lung cancer does not show the decrease with increasing age and synergistic connection between smoking and radiation risk. Therefore, the radiation risk may be on the same order of magnitude as the benefit observed in the NLST. Optimal screening strategy remain uncertain, CT lung cancer screening is not yet ready for implementation. 2. Computed tomographic colonography is as good as colonoscopy for detecting colon cancer and is almost as good as colonoscopy for detecting advanced adenomas, but significantly less sensitive and specific for smaller lesions and disadvantageous for subsequent therapeutic optical colonoscopy if polyps are detected. The average effective dose from CT colonography was estimated 8-10 $mS{\nu}$, which could be a significant dose if administered routinely within the population over many years. CT colonography should a) achieve at least 90% sensitivity and specificity in the size category from 6 and 10 mm, b) offer non-cathartic bowl preparation and c) be optimized and standardized CT parameters if it is to be used for mass screening. 3. There is little evidence that demonstrates, for whole-body scanning, the benefit outweighs the detriment. This test found large portion of patient(86~90.8%) had at least one abnormal finding, whereas only 2% were estimated to have clinically significant disease. Annual scans from ages 45 to 75 years would accrue an estimated lifetime cancer mortality risk of 1.9%. There is no group within the medical community that recommends whole-body CT. No good studies indicate the accuracy of screening CT, at this time. The benefit/risk balance for any of the commonly suggested CT screening techniques has yet to be established. These areas need further research. Therefore wild screening should be avoided.

Psychometric Evaluation of a Six Dimension Scale of Nursing Performance and Student Nurse Stress Index Using an Objective Structured Clinical Examination - Modules for Asthma and Type 1 Diabetes (객관구조화 임상시험을 활용한 간호수행능력의 Six Dimension Scale과 간호학생 스트레스 평가지수의 도구 평가-천식 및 1형 당뇨 모듈을 중심으로)

  • Park, Kyong-Ok;Ahn, Young-Mee;Kang, Na-Rae;Lee, Mi-Jin;Sohn, Min
    • Child Health Nursing Research
    • /
    • v.19 no.2
    • /
    • pp.85-93
    • /
    • 2013
  • Purpose: The study purposes were to describe the process of developing the Korean versions of the Six Dimension Scale of Nursing Performance (Six-D) and Student Nurse Stress Index (SNSI) and psychometric evaluation of the two measurements. Methods: This was a methodology study using a descriptive cross-sectional design with 51 nursing students in 4th year of university. Internal consistency reliability was assessed using Cronbach alphas. Construct validity was determined by exploring correlations among Six-D, SNSI, objective structured clinical examination (OSCE), self-efficacy and grade point average (GPA). Results: Internal consistency reliability of Six-D and SNSI was acceptable with Cronbach's ${\alpha}$ of .95 and .82. Correlation analysis to determine construct validity revealed that Six-D presented positive correlations with OSCE (r=.109~.272) and self-efficacy (r=.005~.161) and negative correlation with GPA (r=-.246~-.394), although all were not statistically significant. SNSI presented all negative correlations with OSCE (r= -.007~-.238), self-efficacy (r=-.246~-.394), and GPA (r=-.092~-.426) and were mostly statistically significant except OSCE. Conclusion: Six-D needs more evidence to confirm validity to predict observed clinical competency and theoretical relationships with self-efficacy and GPA. However, SNSI presented trends of expected relationships with relevant variables. Therefore, further research is recommended in testing validity of Six-D with other student populations.

A Study of the Comparison of Microleakage according to the Types of Cement on the Cast Post and Core (주조 포스트코아에서 시멘트 종류가 미세누출에 미치는 영향)

  • Nam, Ki-Young;Lee, Cheong-Hee;Cho, Kwang-Hyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.1
    • /
    • pp.51-60
    • /
    • 2000
  • The purpose of this study was to compare the microleakage at the interface of cast post and tooth according to the type of cement. Forty anterior teeth with single root were used. The teeth were cut 2 mm coronal from the cementoeamel junction and chamfer finish line was made on 1 mm coronal from the cementoeamel junction. After the routine endodontic treatment, post space was prepared using #5.5 Parapost drill to a depth of 7 mm. After the pick up impression, core building was made to 3 mm of clinical crown with burnout wax, then post and core was cast with nonprecious metal. The teeth were divided into four groups of ten each. In Group I, post and core were cemented with Fleck's(Zinc phosphate cement) In Group II, post and core were cemented with Fuji I(Glass ionomer cement) In Group III, post and core were cemented with Superbond C & B(Composite resin cement) In Group IV, post and core were cemented with Panavia 21(Composite resin cement) All cemented teeth were stored in normal saline at $37^{\circ}C$ for 7 days and thermocycled from $5^{\circ}C$ to $55^{\circ}C$ for 500 cycles with a dwell time of 30 seconds. After thermocycling, teeth were immersed in 1% Basic fuchsin dye for 48 hours. All 40 teeth were then embedded in the epoxy resin and cut buccolingually with a cutting instrument. The degree of penetration of dye at interface was graded on a scale of 0 to 4 using a stereomicroscope at 25 to 40 times magnification. Through the findings of this study, the following conclusion were obtained. 1. All the groups showed the microleakage at the interface of cast post core and tooth. 2. Group I showed the highest microleakage score among the groups with a significant difference(p<0.05). 3. Group II showed higher microleakage score than Group III and Group IV with a significant difference(p<0.05). 4. Group IV showed the lowest microleakage score but there were no significant difference with Group III(p>0.05).

  • PDF

Retention of CAD/CAM Metal Copings Cemented on Short Titanium Abutments with Different Cements (짧은 티타늄 지대주에 합착된 CAD/CAM 금속 코핑의 시멘트 종류에 따른 유지력 비교)

  • Kim, Hyo-Jung;Song, Eun-Young;Yoon, Ji-Young;Lee, Si-Ho;Lee, Yong-Keun;Oh, Nam-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.119-126
    • /
    • 2012
  • State of problem: Cement-retained implant-supported prostheses are routinely used in dentistry. The use of high strength cements has become more popular with the increasing confidence in the stability of the implant-abutment screw connection and the high survival rates of osseointegrated implants. No clinical data on retention of metal copings using CAD/CAM. To evaluate retention of metal copings using CAD/CAM system bonded to short titanium abutment with four different cements and compare retentive strength of metal copings with sandblasting or without sandblasting before cementation. Forty titanium abutment blocks were fabricated and divided into 4 groups of 10 samples each. Forty metal copings with occlusal hole to allow for retention testing were fabricated using CAD/CAM technology. The four cements were Fujicem(Fuji, Japan), Maxcem Elite(Kerr, USA), Panavia F2.0(Kurarary, Japan) and Superbond C&B(Sunmedical, Japan). The copings were cemented on the titanium abutment according to manufacture's recommendation. All samples were stored for 24h at 37oC in 100% humidity and tested for retention using universal testing machine(Instron) at a crosshead speed of 1.0mm/min. Force at retentive failure was recorded in Newton. The mode of failure was also recorded. Means and standard deviations of loads at failure were analyzed using ANOVA and Paired t-test. Statistical significance was set at P<0.05. Panavia F2.0 provided significantly higher retentive strength than Fujicem, Maxcem Elite(P<0.05). Sandblasting significantly increased bond strength(P<0.05). The mode of failure was cement remaining principally on metal copings. Within the limitation of this study, Panavia F2.0 showed significantly stronger retentive strength than Fujicem, Maxcem Elite(p<0.05). The Ranking order of the cements to retain the copings was Panavia F2.0, Fujicem = Maxcem Elite. Sandblasting significantly increased bond strength(P<0.05). The retentive strength of metal copings on implant abutment were influenced by surface roughness and type of cements.

A Study on the ICAO international aviation safety policy, a change of paradigm and the government response to the direction (ICAO 국제항공안전정책 패러다임의 변화 분석과 우리나라 신국제항공안전정책 검토)

  • Chang, Man-Heui;Hwang, Ho-Won
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.28 no.1
    • /
    • pp.73-96
    • /
    • 2013
  • ICAO's Universal Safety Oversight Audit Programme (USOAP) was initially launched in January 1995, in response to widespread concerns about the adequacy of aviation safety oversight around the world. The recent reduction in aircraft accidents and effective role that is evaluated on the basis of these results, and in 2013 the existing 'snapshot approach' to 'regular monitoring system (USOAP-Continuous Monitoring Approach)' was converted to. ICAO aviation safety assessment of the state in today's international community 'aviation safety credibility' as objective indicators to judge the enormous impact on the aviation industry, the state is not satisfactory, especially if the results of the evaluation and expansion of code-share airline ban, reduced international air transit passengers, including premium increases business and economic penalties should. In addition, ICAO implementation of the existing laws and regulations(Prescriptive Approach), but based on the Risk-based prevention model, Proactive Approach introduced the concept of aviation safety system, including international aviation safety policy has been to switch paradigms. This new ICAO international aviation safety policy also applies to the Government of the Republic of Korea in line with the aviation safey policies have changed. In particular, the systematic implementation of safety management for the existing laws and regulations in the center of the safety oversight system of risk-based introduction of the concept of proactive safety management, and According to international standards ICAO aviation service providers operate their own Safety Management System was set out in Aviation Law ever. In addition, the aviation safety is at the center of the field of the safety of aircraft operations and maintenance for the promotion is promoting various safety policies. This new paradigm shift in the international aviation safety policy in line with our state in the international community with the most exemplary aviation safety system firmly established itself as a model, the Government will strengthen the competitiveness of our aviation plans to support. To do this, the government, airlines, aviation officials try all the practical effect would be expected.

  • PDF

The Relationship between Cell-mediated Immunity and Subtypes of Lymphocyte in BAL Fluid and Peripheral Blood in Patients with Pulmonary Tuberculosis (폐결핵 환자의 말초 혈액 및 기관지 폐포세척액내의 임파구 아형과 세포성 매개면역과의 관계)

  • Uh, Soo-Taek;Cha, Mi-Kyung;Lee, Sang-Moo;Kim, Hyun-Tae;Chung, Yeon-Tae;Woo, Jun-Hee;Kim, Yong-Hun;Park, Choon-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.39 no.4
    • /
    • pp.334-342
    • /
    • 1992
  • Background: The activated T lymphocyte by inhalaed mycobacterial antigen may evoke cell-mediated immunity in patients with active pulmonary tuberculosis. These activated lymphocyte may influence the response of tuberculin-purified protein derivative (PPD) in skin test. But occasionally, anergy to PPD appear in patients with pulmonary tuberculosis in spite of active stage. Thus we evaluated the effect of change of subtypes of lymphocyte in bronchoalveolar lavage fluid (BAL) and peripheral blood on anergy to PPD in patients with active pulmonary tuberculosis. Method: We performed tuberculin skin test and flow-cytometry analysis of lymphocytes obtained from BAL fluid and peripheral blood in 11 healthy normal volunteers and 20 patients with active pulmonary tuberculosis. Results: 1) The composition of lymphocyte significantly increased in patients with active pulmonary tuberculosis when compared with that in healthy control ($25.2{\pm}4.8$ vs $6.5{\pm}1.3%$, p<0.01), but composition of monocyte significantly decreased ($69.6{\pm}5.7$ vs $89.2{\pm}1.4%$, p<0.05) in analysis of BAL fluid. 2) There were no differences in compositions of cells in BAL fluid between responders and no-responders to PPD. 3) The compositions of CD3 (+), CD4 (+), CD3 (+) IL-2R (+), CD3 (+) HLA-DR (+) significantly increased in BAL fluid when compared with those in peripheral blood in patients with active pulmonary tuberculosis. But the composition of CDS (+), CD4/CDS were not different between BAL fluid and peripheral blood. 4) There were no correlations between response to PPD and compositions of cells and lymphocyte subtypes in BAL fluid and peripheral blood in all patients with tuberculosis, responders, and no-responders, respectively. Conclusion: From these results, we suggest no direct relationship between compositions of inflammatory cells in bronchoalveolar lavage fluid and we could not rule out the possibility of compartmentalization of activated lymphocyte involving in anergy to PPD in skin test in patients with active pulmonary tuberculosis.

  • PDF

Relative Risk for Lung Cancer According to Smoking Habits in Koreans (한국인의 흡연습관에 따른 폐암발생의 비교위험도)

  • Shin, Kyeong-Cheol;Ryoo, Hun-Mo;Park, Hye-Jung;Mun, Yeung-Chul;Chung, Jin-Hong;Lee, Kwan-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.3
    • /
    • pp.331-338
    • /
    • 2000
  • Background : While the incidence of lung cancer is gradually leveling off in developed countries, it is continuing to rise in Korea. With the rapid increase in the prevalence of smoking among women and the young, the incidence of lung cancer is also expected to increase within the next three and four decades. The aims of the present study are to analyze the smoking habits in patients with lung cancer and to evaluate of the relative risk of lung cancer according to patients' smoking habits. Method : This investigation was a hospital-based, case control study, which included data of 93 case subjects with lung cancer and 1132 controls with disease unrelated to smoking, obtained through a smoking history questionnaire by a direct personal interview. Result : Compared with non-smokers, those who smoked for more than 50 years had an odds ratio for lung cancer of 8.8(1.8-20.7). The odds ratios was 8.5(3.5-20.7) for those who smoke more than a total of 40 cigarettes per day and 5.5(2.3-13.3) for men who started habitual smoking under the age of 20. The risk increased for men with more than of cigarette smoking(OR : 5.5, 95% CIa : 2.6-11.9). Odds ratios associated with cigarette smoking were 2.5(1.1-5.8) and 5.1(2.6-10.4) for ex-smokers and current smokers, respectively and 2.2(0.0-4.6) for non-filter smokers of more than 16 years. Conclusion : There was a clear dose-response relationship between the risk of lung cancer and smoking. It can be concluded that dose is an important risk factor for lung cancer, as well as smoking habits.

  • PDF

A Pilot Study of Bone Mineral Density in Men with Chronic Obstructive Pulmonary Disease (남자 만성폐쇄성폐질환 환자들의 골밀도에 대한 예비연구)

  • Bae, Yun Oh;Han, Minsoo;Lee, Seong-Kyu;Kim, Jeong Nyum;Kim, Jeong Sik;Kim, Jinho;Cho, Yongseon;Lee, Yang Deok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.54 no.4
    • /
    • pp.395-402
    • /
    • 2003
  • Background : Patients with chronic obstructive pulmonary disease (COPD) are at increased risk for osteoporosis, which has implications for mobility and even mortality. The goal of this pilot study was to evaluate bone mineral density (BMD) and risk factors for osteoporosis in a limited number of men with COPD. Methods : We checked BMD, $FEV_1$(% of predicted) and investigated risk factors for osteoporosis in 44 male patients with COPD who visited our hospital from January to August 2002. Results : Mean(${\pm}$) age was $69{\pm}9$ yrs, body mass index(BMI) $21{\pm}3kg/m^2$, $FEV_1$ $50{\pm}18%$ of predicted, lumbar spine T-score $-3.0{\pm}1.2$, lumbar spine Z-score $-2.0{\pm}1.2$, and lumbar spine BMD $0.76{\pm}0.13g/cm^2$. Osteoporosis(T-score below -2.5) was present in 27 patients(61.4%) and osteopenia(T-score between -1 and -2.5) in 17(38.6%). None of the patients had normal BMD. There was no relationship between BMD and $FEV_1$(% of predicted). There were significant differences in smoking, alcohol consumption, exercise, cumulative steroid dose, BMI and BMD among the three groups according to $FEV_1$(% of predicted) (group1 : ${\geq}65%$, group2 : 50-64%, group3 : ${\leq}49%$), except age. However, there were no significant differences in these variables between the osteopenia and osteoporosis groups, except BMI. Linear Regression(Stepwise) analysis showed that lumbar BMD was correlated with BMI & exercise. Conclusion : BMD is significantly reduced in men with COPD. There was no relationship between BMD and pulmonary function.