• Title/Summary/Keyword: 영상 초점면

Search Result 63, Processing Time 0.025 seconds

고해상도 위성 탑재 카메라의 광학계 개념설계 기법

  • 장홍술
    • Bulletin of the Korean Space Science Society
    • /
    • 2004.04a
    • /
    • pp.80-80
    • /
    • 2004
  • 해상도가 높아질수록 위성 탑재 카메라의 광학적 설계 조건은 까다롭다. 특히 1m급의 고해상도 영상을 얻기 위해서는 개념설계 단계에서부터 여러 가지 기술적인 면과 운용적인 면을 동시에 고려해야 하며 이러한 조건들이 상호 연관성을 가지면서 광학계의 형태나 성능을 결정하므로 다양한 해석과 분석이 필요하다. 해상도, 촬영고도, 관측폭 그리고 촬영소자의 크기에 의해 광학계의 초점거리가 결정되며 광학계의 유효구경을 추가하면 신호량 성능에 대한 예측이 가능하다. (중략)

  • PDF

Scanning confocal microscope using a quad-detector (4분할 photodiode를 이용한 scanning confocal microscope)

  • 유석진;김수철;이진서;권남익
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.2
    • /
    • pp.165-168
    • /
    • 1997
  • We have constructed a scanning confocal microscope using a 780 nm semiconductor laser, an actuator of a compact disk player and a quad-detector. This device detects heights and characteristics of a surface. The laser focus was located at the surface of a sample by using the error signal obtained by a quad-dector, and the current supplied to the actuator for lens was displayed as a height. The materials of a surface were classified according to reflected total intensities and was displayed by different color in a monitor. The device has very samll dimensions of 30 mm$\times$20 mm$\times$20 mm and scan field is 1.6 mm$\times$1.6mm. We obtained two images, one using only reflected light and the other using an error signal from a quad-detector and compared these two images.

  • PDF

Two-Side Holography System for the Measurements of Spray Characteristics (양 방향 홀로그래피를 이용한 분무 특성 해석 시스템)

  • Choo, Yeon-Jun;Kang, Bo-Seon
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1755-1760
    • /
    • 2004
  • The holographic velocimetry system has a significant potential for the measurements of three dimensional velocities of particles. In this study, orthogonal two-side holography system was developed to obtain three dimensional velocities and sizes of spray droplets. To get high quality of reconstructed images, singe-exposure holography at two time moments and two orthogonal sides was adopted instead of multi-exposure, single-side holography. From three dimensional positions of droplets determined by reconstruction and image processing system, the three dimensional velocities and sizes of each droplet was extracted using the PTV algorithm. To determine the position of particles in the optical axis, a new focusing parameter was introduced based on the correlation between two droplet images at the same distance. The measured results by holography system were compared with those by the PDPA.

  • PDF

Defect Inspection of Globular Lens Using Multiple Focal Plane Images (다중의 초점면 영상을 통한 구면 렌즈의 이물 검사)

  • Park, Jong-Won;Jang, Jin-Woo;Jeong, Ho-Young;Choi, Gyeong-Ju
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2014.11a
    • /
    • pp.1014-1017
    • /
    • 2014
  • 모바일 카메라 모듈의 성능 향상에 따라, 카메라 렌즈의 미세한 오염도 큰 불량요인으로 작용하게 되었다. 그로인한 새로운 검사 시스템들과 검사방법이 제안되었다. 본 논문에서 제안하는 새로운 검사방식은 영상처리를 통해 기존에 비해 정확도가 높고, 전처리 횟수가 적은 이점이 있어 산업현장에서 적용 시 효율성 증대를 기대할 수 있다.

Image Restoration Considering Chromatic Aberration Problem of Multi-Spectral Filter Array Image (다중 분광 필터 배열 영상의 색수차 문제를 고려한 영상 복원 알고리즘)

  • Kwon, Ji Yong;Kang, Moon Gi
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.5
    • /
    • pp.123-131
    • /
    • 2016
  • To capture color and near-infrared images simultaneously, a multi-spectral filter array(MSFA) sensor is used. This is because an NIR band gives additional invisible information to human eyes to see subject under extremely low light level. However, because lenses have different refractive indices for different wavelengths, lenses may fail to focus widely different rays to the same convergence point. This is why a chromatic aberration(CA) problem occurs and images are degraded. In this paper, the image restoration algorithm for an MSFA image, which removes the CA problem, is presented. The obtained MSFA image is filtered by the estimated low-pass kernel to generate a base image. This base image is used to remove CA problem in multi-spectral(MS) images. By modeling the image degradation process and by using the least squares approach of the difference between the high-frequencies of the base and MS images, the desired high-resolution MS images are reconstructed. The experimental results show that the proposed algorithm performs well in estimating the high-quality MS images and reducing the chromatic aberration problem.

Fabrication of [320×256]-FPA Infrared Thermographic Module Based on [InAs/GaSb] Strained-Layer Superlattice ([InAs/GaSb] 응력 초격자에 기초한 [320×256]-FPA 적외선 열영상 모듈 제작)

  • Lee, S.J.;Noh, S.K.;Bae, S.H.;Jung, H.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.1
    • /
    • pp.22-29
    • /
    • 2011
  • An infrared thermographic imaging module of [$320{\times}256$] focal-plane array (FPA) based on [InAs/GaSb] strained-layer superlattice (SLS) was fabricated, and its images were demonstrated. The p-i-n device consisted of an active layer (i) of 300-period [13/7]-ML [InAs/GaSb]-SLS and a pair of p/n-electrodes of (60/115)-period [InAs:(Be/Si)/GaSb]-SLS. FTIR photoresponse spectra taken from a test device revealed that the peak wavelength (${\lambda}_p$) and the cutoff wavelength (${\lambda}_{co}$) were approximately $3.1/2.7{\mu}m$ and $3.8{\mu}m$, respectively, and it was confirmed that the device was operated up to a temperature of 180 K. The $30/24-{\mu}m$ design rule was applied to single pixel pitch/mesa, and a standard photolithography was introduced for [$320{\times}256$]-FPA fabrication. An FPA-ROIC thermographic module was accomplished by using a $18/10-{\mu}m$ In-bump/UBM process and a flip-chip bonding technique, and the thermographic image was demonstrated by utilizing a mid-infrared camera and an image processor.

Study on 2 types of Liquid Lens control system used for the autofocus (자동초점에 사용되는 두 가지 Liquid Lens제어에 관한 연구)

  • Kim, Nam-Woo;Hur, Chang-Wu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.6
    • /
    • pp.1493-1498
    • /
    • 2015
  • The autofocus system is automatically to drive the focus. It is very important to computer vision system. In the case of a compact camera, the actuator technology is used for auto-focus in mass production. the position sensor is required, the circuit configuration and easy method is widely used in VCM, compared to the stability of the drive size and the noise is a big stepping motor type, size has a piezo system having a humidity problem and the small leaded vulnerability. In addition, there is a liquid lens system, the advantages of low power in a compact structure but also a structure with proven quality and reliability and features required pressure. In this paper, we implement two control systems that can control the actuator as a liquid range of VCM using a sharpness of the image acquired by the image sensor automatically initiates 5Mpixel class was the implementation verification of focusing.

Iterative Image REstoration Using Adaptive Acceleration Parameter (적응성 가속변수를 이용한 반복영상복원)

  • 김태선;권동현;이태홍
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2000.04a
    • /
    • pp.137-140
    • /
    • 2000
  • 카메라의 렌즈 등 광학장비의 성능 제한으로 인하여 초점이 맞지 않아 흐려지고 잡음으로 훼손된 영상을 복원하는데 일반적으로 반복복원방법이 사용된다. 이 경우에 가속변수는 훼손영상에 관계없이 영상전체에 일률적으로 적용되기 때문에 흐려짐 훼손이 심한 윤곽부분도 훼손이 작은 평면영역이 같이 일정하게 처리되어 수렴속도가 느려지고 시각적으로 중요한 윤곽부분의 복원에는 효율적이지 못하다. 이러한 문제점을 해결하기 위하여 본 논문에서는 흐려짐 훼손이 작은 평면영역은 가속변수를 작게하고 훼손이 큰 윤곽영역은 가속변수를 크게 하여 영상의 국부적인 특성에 따라 적응적으로 반복 복원하는 방법을 제안하였다. 제안한 복원방법은 기존의 방법과 비교하여 수렴속도가 빨라지고 시각적으로 중요한 윤곽정보의 복원에도 효율적임을 실험결과를 통해 할 수 있었으며, MSE면에서도 우수하였다.

  • PDF

Design of Aspheric Imaging Optical System having 24mm Focal Length for MWIR with Facing Symmetric Lenses (마주보는 대칭렌즈를 가지는 MWIR용 초점거리 24mm의 비구면 결상광학계 설계)

  • Lee, Sang-Kil;Kim, Boo-Tae;Lee, Dong-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.9
    • /
    • pp.183-189
    • /
    • 2018
  • This study deals with the design and development of imaging optics having 24mm focal length for MWIR ($3{\sim}5{\mu}m$) with two symmetrical lenses facing each other. We used CodeV in our optical design, and we performed the optimization process to have the resolution and angle of view satisfying the user's requirements. The materials of lenses were limited to two types, including KCIR035 with a refractive index of 1.7589, developed in Korea. The optical system designed in this way consists of two aspherical lenses made of KCIR035 material having the same shape and one spherical lens made of Si. Here, the arrangement of the two aspherical lenses is characterized by having a symmetrical structure facing each other. And this optical system has a resolution of MTF value of 0.35 or more at a line width of 20 lp / mm. Therefore, it is considered that this optical system has the capability to be applied to a thermal imaging camera using a $206{\times}156$ array MWIR detection device having a pixel size of $25{\mu}m$.

Enhanced Reconstruction of Heavy Occluded Objects Using Estimation of Variance in Volumetric Integral Imaging (VII) (Volumetric 집적영상에서 분산 추정을 이용한 심하게 은폐된 물체의 향상된 복원)

  • Hwang, Yong-Seok;Kim, Eun-Soo
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.6
    • /
    • pp.389-393
    • /
    • 2008
  • Enhanced reconstruction of heavy occluded objects was represented using estimation of variance in computational integral imaging. The system is analyzed to extract information of enhanced reconstruction from an elemental images set. To obtain elemental images with enhanced resolution, low focus error, and large depth of focus, synthetic aperture integral imaging (SAII) utilizing a digital camera has been adopted. The focused areas of the reconstructed image are varied with the distance of the reconstruction plane. When an occluded object is occluded heavily, an occluded object can not be reconstructed by removing the occluding object. To obtain reconstruction of the occluded object by remedying the effect of heavy occlusion, the statistical technique has been adopted.