• Title/Summary/Keyword: 영상의학과

Search Result 2,555, Processing Time 0.026 seconds

Automated Functional Morphology Measurement Using Cardiac SPECT Images (SPECT 영상을 사용한 기능적 심근형태의 자동 계측법 개발)

  • Choi, Seok-Yoon;Ko, Seong-Jin;Kang, Se-Sik;Kim, Chang-Soo;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.133-139
    • /
    • 2012
  • For the examination of nuclear medicine, myocardial scan is a good method to evaluate a hemodynamic importance of coronary heart disease. but, the automatized qualitative measurement is additionally necessary to improve the decoding efficiency. we suggests the creation of cardiac three-dimensional model and model of three-dimensional cardiac thickness as a new measurement. For the experiment, cardiac reduced cross section was obtained from SPECT. Next, the pre-process was performed and image segmentation was fulfilled by level set. for the modeling of left cardiac thickness, it was realized by applying difference equation of two-dimensional laplace equation. As the result of experiment, it was successful to measure internal wall and external wall and three-dimensional modeling was realized by coordinate. and, with laplace formula, it was successful to develop the thickness of cardiac wall. through the three-dimensional model, defects were observed easily and position of lesion was grasped rapidly by the revolution of model. The model which was developed as the support index of decoding will provide decoding information to doctor additionally and reduce the rate of false diagnosis as well as play a great role for diagnosing IHD early.

Improved Scatter Correction for SPECT Images : A Monte Carlo Simulation Study (SPECT 영상 산란보정 개선: 몬테칼로 시뮬레이션 연구)

  • Bong, Jung-Kyun;Kim, Hee-Joung;Son, Hye-Kyung;Lee, Jong-Doo;Jung, Hae-Jo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.3
    • /
    • pp.163-173
    • /
    • 2005
  • Purpose: Abutted scatter energy windows used for a triple energy window (TEW) method may provide wrong estimation of scatter. This study is to propose an extended TEW (ETEW) method, which doesn't require abutted scatter energy windows and overcomes the shortcomings of TEW method. Materials & Methods: The ETEW is a modification of the TEW which corrects for scatter by using abutted scatter rejection windows, which can overestimate or underestimate scatter. The ETEW is compared to the TEW using Monte Carlo simulated data for point sources as well as hot and cold spheres in a cylindrical water phantom. Various main energy window widths (10 %, 15 % and 20 %) were simulated. Both TEW and ETEW improved image contrast, % recovery coefficients and normalized standard deviation. Results: Both of TEW and ETEW improved image contrast and % recovery coefficients. Estimated scatter components by the TEW were not proportional to the true scatter components over the main energy windows when ones of 10 %, 15 %, and 20 % were simulated. The ETEW linearly estimated scatter components over the width of the main energy windows. Conclusion: We extended the TEW method into the method which could linearly estimate scatter components over the main energy windows.

The Usefulness of Bone Scintigraphy in SAPHO Syndrome (SAPHO 증후군에서 골신티그라피의 유용성)

  • Lim, Seok-Tae;Sohn, Myung-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.4
    • /
    • pp.255-260
    • /
    • 2002
  • Purpose: SAPHO syndrome is well known to various disease entities including synovitis, acne, pustulosis, hyperostosis and polyarthritis. The purpose of this study is to evaluate sicntigraphic findings and to compare with radiologic findings in SAPHO syndrome. Materials and Methods: Five patients (M:F=5.0, Age $22.8{\pm}4.78$ yrs) with SAPHO syndrome were enrolled in our study. All patients underwent whole-body bone scintigraphy with intravenous administration of 740 MBq of Tc-99m MDP. Among them, two patients were additionally perfomed SPECT of the spine to evaluate the location and extort of spinal lesion. Results: All patients were demonstrated abnormal increased uptakes in sternoclavicular joint (SC), sacroiliac joint (SI), and small joints of both hands. Among them, three patients were bilateral involvement (3/5) and two were unilateral (2/5) in SC. involvement of SI showed bilateral in four patients (4/5) and unilateral in one (1/5). SPECT images demonstrate that the lesion sites of the lumbar spine are more likely facet joints than vertebral bodies or pedicles. Conclusion: As SAPHO syndrome is the disease entity involved polyarticular joints with various dermatologic manifestations, the bone scintigraphy may be a very useful method to evaluate the location and extent of joint involvement, and to avoid inadequate surgical management or ineffective antibiotic treatment.

A Phantom Study for the Optimal Low-dose Protocol in Chest Computed Tomography Examination (흉부 전산화단층촬영검사를 위한 최적의 저선량 프로토콜에 관한 팬텀연구)

  • Kim, Young-Keun;Yang, Sook;Wang, Tae-uk;Kim, Eun-Hye
    • Journal of radiological science and technology
    • /
    • v.44 no.2
    • /
    • pp.101-107
    • /
    • 2021
  • The purpose of this study was to evaluate optimal CT scan parameters to minimize patient dose to the irradiation and maintain satisfactory image quality in low-dose chest computed tomography (CT) scans. In a chest anthropomorphic phantom, chest CT scans were performed at different kVp and mA within reference of 3.4mGy in volume CT Dose Index (CTDIvol). The following quantitative parameters had been statistically evaluated: image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM). Nine radiographers conducted the blind test to select the optimal kVp-mA combination. Results indicated that the kVp-mA combination of 80kVp-90mA, 100kVp-50mA, 120kVp-30mA and 140kVp-30mA were obtained high SNR and CNR. The 120kVp-30mA combination offered good compromise in the FOM, which showed the quality and dose performance. In the blind test, an image of 80kVp-90mA obtained a high score with 4.7 points, and 120kVp-10mA or 140kVp-10mA with a low tube current were observed severe noise and poor image quality, thus resulting in decreased diagnostic accuracy. On the other hand, in the combination of high kVp and high mA(140kVp-90mA), the image quality was improved, but the radiation dose was also increased. the FOM value of 140kVp-90mA was lower than 120kVp-30mA. The application of appropriate scan parameters in low-dose chest CT scans produced satisfactory results in dose and image quality for the accuracy of the clinical diagnosis.

Correlation Analysis of between Patient and Equipment Factors and Radiation Dose in Chest Low Dose and Abdominal Non-contrast CT (흉부 저선량 및 복부 비조영 CT 검사에서 환자 및 장비 인자와 선량과의 상관관계 분석)

  • Shim, Jina;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.117-123
    • /
    • 2021
  • This paper is to establish a basis for a dose reduction strategy by confirming correlations with the factors that may affect the radiation dose based on the dose records in low-dose chest CT and abdominal non-contrast CT. In order to find out the causes of unnecessary exposure, the correlation between seven factors (age, gender, height, weight, BMI, patient status [inpatient and outpatient], and use of dose modulation) and CT dose were identified. Logistic regression was used as the statistical analysis for correlation verification. In the low dose chest CT, as the higher values of height and BMI and dose modulation off were associated with lowering the risk exceeding Diagnostic Reference Levels(DRL) (odds ration<1, p<0.05). However, as woman compared to man and the higher values of weight were associated with highering the risk exceeding DRL (odds ration>1, p<0.05). In the abdomen CT, as dose modulation off were associated with lowering the risk exceeding DRL (odds ration<1, p<0.05). Therefore It is necessary to conduct research on the relationship between various factors affecting radiation exposure and patient radiation dose for reducing the dose.

Analysis of Satisfaction and Problems of Clinic Radiological Technologist on the Supplementary Education (보수교육에 대한 의원방사선사의 만족도와 문제점 분석)

  • Jeong, Bong-Jae;Park, Jun-Hong;Song, Jae-Heung;Noh, Si-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.861-868
    • /
    • 2018
  • As the research about supplementary education of radiological technologist who works in medical clinics, this study was conducted to draw the improvements by analyzing the satisfaction level and problems of the supplementary education. During November 01, 2016 to April 30, 2017, after we distributed a total of 150 questionnaires for the survey to radiological technologists working at medical clinics located in Changwon-si, Gyoungsangnam province, 106 questionnaires suitable for research were analysis by using SPSS 18.0 statistical analysis software. As the sociodemographic characteristics, the age, gender, working period, level of education, and working department were used. And As the welfare factors, working environment, financial support, educational opportunity, medical support, working culture, etc. were used. As the satisfaction factors, 21 items such as system, subject, help, appropriateness of lecturer selection, professionalism were used. And as the problem factors, 18 items such as place, transportation, diversity, administrative treatment, education promotion, proceed method were used. Consequentially, the satisfaction level(3.02 point) of the supplementary education were confirmed as normal level. And the problems(3.18 point) of the supplementary education was analyzed a little higher. The supplementary education is the mandatory education that any health and medical service personnel must complete every three years for license re-issuance. There were many opinions that the supplementary education for radiologists working in various medical institutions did not meet the education level of radiologists working in the medical clinics. In order to improve the satisfaction of the supplementary education of medical clinic's radiological technologist, it should be improved the quality of education through a practical education program that reflects various opinions and improvements on conservative education.

Differential Diagnosis of Benign and Malignant Thyroid Nodules Using the K-TIRADS Scoring System in Thyroid Ultrasound (갑상샘 초음파 검사에서 K-TIRADS 점수화 체계를 사용한 양성과 악성 갑상샘 결절의 감별진단)

  • An, Hyun;Im, In Cheol;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.201-207
    • /
    • 2019
  • This study has evaluated whether the method of using the combination of different risk group, according to K-TIRADS classification and K-TIRADS classification in thyroid ultrasonography is useful in a differential diagnosis of benign and malignant nodules. The subject was patients underwent thyroid ultrasonography and retrospective analysis were performed based on the results of fine needle aspiration cytology. A chi-square test was performed for the difference analysis of the score system in K-TIRADS and different risk group according to the benign and malignant of thyroid nodule. The optimized cut off value was determined by the K-TIRADS score and different risk group to predict malignant nodule through ROC curve analysis. In the differential verification result of K-TIRADS and different risk group, according to the classification of benign and malignant nodule group each showed significant difference statistically(p=.001). In the point classification according to K-TIRADS for the prediction of benign and malignant in ROC curve analysis showed AUC 0.786, Cut-off value>2(p=.001), and in the different risk group, it was decided as AUC 0.640, Cut-off value>2(p=.001). When discovering the nodule in thyroid ultrasound, it is considered that the K-TIRADAS which helps in identifying benign and malignant thyroid nodules, it is considered to be helpful in the differential diagnosis of thyroid nodules, than the classification system according to Different risk group, and when applying the classification system according to K-TIRADS, it is considered that it can reduce unnecessary fine needle aspiration cytology and could be helpful in finding the malignant nodules early.

Clinical Usefulness of Ultrasonography in the Diagnosis of Fatty Liver (지방간 진단에 있어 초음파 검사의 임상적 유용성 연구)

  • An, Hyun;Lee, Hyo Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.349-357
    • /
    • 2019
  • The purpose of this study was to evaluate the clinical significance of ultrasonographic classification of fatty liver in three grades. From June 2018 to April 2019, 1047 patients (818 males and 229 females) diagnosed as fatty liver among 3607 patients who underwent abdominal ultrasonography at Busan screening center. Ultrasonography was classified into three grades: Grade I (mild fatty liver), Grade II (moderate fatty liver), and Grade III (severe fatty liver) according to the degree of parenchyma texture, acoustic attenuation, Obesity index, hematological test, and metabolic syndrome. The average age of men in each sex increased with the increase of the fatty liver. Body mass index (BMI) and waist circumference were significantly increased in both men and women (p=.000). hematological analysis showed that AST, ALT, ${\gamma}-GTP$, TG, fasting blood sugar, and glycated hemoglobin were significantly different from each other (p<.05). In women, ALT, ${\gamma}-GTP$ and TG showed a significant difference with increasing fatty liver (p<.05). The prevalence of metabolic syndrome was significantly increased in both sexes as the grade of fatty liver increased (p=.000). Based on the results of this study, it is suggested that the use of ultrasound - guided fatty liver according to severity may be useful for the treatment and follow - up of fatty liver if the liver grade is divided in consideration of hematological variables and metabolic syndrome.

Comparative Study on Signal Strength of Mechanical Index Using Ultrasound Machines with SonoVue Contrast (Sonovue 초음파 조영제를 이용한 장비 간 Mechanical Index의 변화에 따른 신호 강도 비교연구)

  • Kim, Myung-Seok;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.21-29
    • /
    • 2019
  • The purpose of this study was to compare the MI using SonoVue along with different machines output and to infer the meaning of the signal difference under the same condition. All of the comparative instruments showed strong signal values at early stage as MI value increased. Over time, the inter-instrumental signal values showed signal attenuation under all conditions except for 10 min of the condition of MI 0.1 of RS85A. E9 and EPIQ7 showed signal degradation due to microbubble collapse over time at all MI values. In the comparison of equipment, the signal strengths of MI 0.1, 0.2, and 0.4 were high in order of EPIQ7, RS85A and E9. In the quantitative analysis, there were statistically significant from the SNR and CNR that were obtained from RS85A and E9 (P-value<0.05). In the quantitative analysis, Epiq7 was statistically significant except for CNR as the MI value was changed In the contrast-enhanced ultrasound, even though MI value was low (MI <0.05), it will be helpful for diagnosis, controlling the MI and scan time because a difference in signal intensity was shown between the three machines.

Comparative Evaluation of Radioactive Isotope in Concrete by Heavy Ion Particle using Monte Carlo Simulation (몬테카를로 시뮬레이션을 통한 중하전입자의 콘크리트 방사화 비교평가)

  • Bae, Sang-Il;Cho, Yong-In;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.359-365
    • /
    • 2021
  • A heavy particle accelerator is a device that accelerates particles using high energy and is used in various fields such as medical and industrial fields as well as research. However, secondary neutrons and particle fragments are generated by the high-energy particle beam, and among them, the neutrons do not have an electric charge and directly interact with the nucleus to cause radiation of the material. Quantitative evaluation of the radioactive material produced in this way is necessary, but there are many difficulties in actual measurement during or after operation. Therefore, this study compared and evaluated the generated radioactive material in the concrete shield for protons and carbon ions of specific energy by using the simulation code FLUKA. For the evaluation of each energy of proton beam and carbon ion, the reliability of the source term was secured within 2% of the relative error with the data of the NASA Space Radiation Laboratory(NSRL), which is an internationally standardized data. In the evaluation, carbon ions exhibited higher neutron flux than protons. Afterwards, in the evaluation of radioactive materials under actual operating conditions for disposal, a large amount of short-lived beta-decay nuclides occurred immediately after the operation was terminated, and in the case of protons with a high beam speed, more radioactive products were generated than carbon ions. At this time, radionuclides of 44Sc, 3H and 22Na were observed at a high rate. In addition, as the cooling time elapsed, the ratio of long-lived nuclides increased. For nonparticulate radionuclides, 3H, 22Na, and for particulate radionuclides, 44Ti, 55Fe, 60Co, 152Eu, and 154Eu nuclides showed a high ratio. In this study, it is judged that it is possible to use the particle accelerator as basic data for facility maintenance, repair and dismantling through the prediction of radioactive materials in concrete according to the cooling time after operation and termination of operation.