• Title/Summary/Keyword: 영상신호 분석

Search Result 1,007, Processing Time 0.026 seconds

Clinical Findings of Phenylketonuria Patients in Korea (페닐케톤뇨증의 임상적 고찰)

  • Shin, Ik Soon;Lee, Dong Hwan
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.12 no.1
    • /
    • pp.14-22
    • /
    • 2012
  • Objectives: This study was performed to review clinical manifestations of hyperphenylalaninemia patients in Korean. Methods: 178 cases of hyperphenyalaninemia were diagnosed at department of pediatrics, Soonchunhyang University Hospital from January, 1983 to August. We reviewed DNA analysis, MR imaging, EEG, radiography of the left hand and wrist, bone densitometry (BMD), IQ test of hyperphenyalaninemia patients. Results: Out of 178 cases, 161 cases were diagnosed classic phenylketonuria and 17 cases were diagnosed BH4 deficiency. 122 cases performed DNA analysis. R243Q (10.3%), Y204C (9.9%), and IVS4-1G>A (8.1%) mutations were predominant. 22 cases underwent MR imaging. Varying degrees of symmetrical high signal intensity were noted on T2-weighted sequences in the periventricular deep white matter of 15 cases. 23 cases were performed EEG. 12 cases (52.3%) showed abnormal pattern. EEG abnormalities showed in 11 cases. On lumbar BMD four of 11 cases (36%) showed reduced bone density of more than 1 S.D. in four of 11 cases, bone age was less than chronological age by at least one year. 18 cases were performed IQ test. Mean IQ scores was $84{\pm}21.6$. Among older than 15 years (9 cases), Mean IQ scores was $72{\pm}21.2$. PTPS deficiency was 14 cases, DHPR deficiency was 2 cases, and GTPCH deficiency was 1 case. Conclusion: We confirmed there were varieties of DNA mutations. And MR imaging and EEG were nonspecific in PKU patients. Older children showed lower IQ score. Low phenylalanine diet prevents brain damage in PKU patient. Not only first few years of life but also lifetime, Keeping low phenylalanine diet is important.

  • PDF

Assessing the repeatability of reflection seismic data in the presence of complex near-surface conditions CO2CRC Otway Project, Victoria, Australia (복잡한 천부구조하에서 반사법 탄성파자료의 반복성에 대한 평가, 호주, 빅토리아, CO2CRC Otway 프로젝트)

  • Al-Jabri, Yousuf;Urosevic, Milovan
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.1
    • /
    • pp.24-30
    • /
    • 2010
  • This study utilises repeated numerical tests to understand the effects of variable near-surface conditions on time-lapse seismic surveys. The numerical tests were aimed at reproducing the significant scattering observed in field experiments conducted at the Naylor site in the Otway Basin for the purpose of $CO_2$ sequestration. In particular, the variation of elastic properties of both the top soil and the deeper rugose clay/limestone interface as a function of varying water saturation were investigated. Such tests simulate the measurements conducted in dry and wet seasons and to evaluate the contribution of these seasonal variations to seismic measurements in terms of non-repeatability. Full elastic pre-stack modelling experiments were carried out to quantify these effects and evaluate their individual contributions. The results show that the relatively simple scattering effects of the corrugated near-surface clay/limestone interface can have a profound effect on time-lapse surveys. The experiments also show that the changes in top soil saturation could potentially affect seismic signature even more than the corrugated deeper surface. Overall agreement between numerically predicted and in situ measured normalised root-mean-square (NRMS) differences between repeated (time-lapse) 2D seismic surveys warrant further investigation. Future field studies will include in situ measurements of the elastic properties of the weathered zone through the use of 'micro Vertical Seismic Profiling (VSP)' arrays and very dense refraction surveys. The results of this work may impact on other areas not associated with $CO_2$ sequestration, such as imaging oil production over areas where producing fields suffer from a karstic topography, such as in the Middle East and Australia.

Hypertrophy of the Anterior Cruciate Ligament of the Knee (슬관절의 전방 십자 인대의 비후)

  • Cho Sung-Do;Park Tae-Woo;Cho Yong-Sun;Kim Bum-Soo;Lew Sogu;Yang Seoung-Oh;Kim Sung-Sook;Hwang Su-Yeon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.2
    • /
    • pp.63-68
    • /
    • 2001
  • Purpose : To propose the diagnosis, 'hypertrophy of the anterior cruciate ligament(ACL)', and its clinical, radiological and pathological characteristics. Materials & Method : Since Dec. 1995, we have experienced 10 patients(12 knees) with hypertrophy of the ACL. There were 2 males and 8 females, and the age of the patients ranged from 35 to 67 years. Characteristics of clinical, radiological and pathological findings were analysed. Results : The chief complaint was insidious onset of dull pain on the knee which became worse with activity. The constant physical finding was painful limitation of full extension of the knee. Sagittal MR images showed diffuse swelling of the ACL, similar finding that could be seen in acute ACL tear. Arthroscopically, noted was a marked enlargement of the ACL causing notch impingement. Biopsies of the hypertrophied ACL showed increased collagenous tissue with variable degree of myxoid degeneration. With partial excision of the hypertrophied ACL with or without notchplasty, the symptoms improved in all. Conclusion : Hypertrophy of the ACL, a newly proposed diagnosis, should be considered be determining the cause of the painful knee, and further study should be done about its pathogenesis.

  • PDF

The P300 Source Localization in the Patients with Obsessive-Compulsive Disorder using the LORETA Imaging and SPM (강박장애에서 LORETA 영상을 이용한 P300 국소원의 통계적 분석)

  • Park, Sung-Kun;Choi, Jung-Seok;Yu, Soh-Young;Lee, Bo Reom;Kang, Seung-Suk;Roh, Kyu Sik;Ha, Tae-Hyun;Kwon, Jun Soo
    • Korean Journal of Biological Psychiatry
    • /
    • v.10 no.2
    • /
    • pp.168-176
    • /
    • 2003
  • Objectives:We investigated the characteristics of P300 generators in obsessive-compulsive disorder(OCD) patients by using voxel-based statistical parametric mapping of current density images. Methods:P300 generators, produced by a rare target tone of 1500Hz under a frequent non-target tone of 1,000Hz, were measured in 15 right-handed OCD patients and 15 controls. Low Resolution Electromagnetic Tomography(LORETA), using a realistic head model of the boundary element method based on individual MRI, was applied to the 128-channel EEG. Statistical parametric mapping(SPM) was applied for the statistical analysis. Results:We found that both groups had the mean current density of P300 in the parietal, temporal and prefrontal lobe. There was a trend for decreased current density in the prefrontal area in OCD patients. The statistical comparison showed current density increase in the supraparietal area, a statistically significant longer P300 latency and a trend for reduced P300 amplitude in OCD patients. Conclusion:It suggests that P300 source of both groups exists in multiple brain regions at the same time. And both groups had no statistically significant differences in the current density of P300 except for increased current density in the supraparietal area in OCD patients. But, considering the statistically significant longer P300 latency, a trend for reduced P300 amplitude and relative mean current density reduction in the prefrontal area in OCD patients, this study suggests that the frontal lobe may have a reduced normal inhibitory process in OCD patients.

  • PDF

A study of next generation OpenCable systems for Ultra-High Definition television broadcasting (초 고화질 텔레비전 방송을 위한 차세대 오픈 케이블 방식에 대한 연구)

  • Cho, Chang-Yeon;Heo, Jun;Kim, Joon-Tae
    • Journal of Broadcast Engineering
    • /
    • v.14 no.2
    • /
    • pp.228-237
    • /
    • 2009
  • This paper examines the potential of Ultra-High Definition TV (UD-TV) broadcasting transmission systems beyond HD-TV over cable channel. Firstly, we analyze the trend of TOV(Threshold of Visibility) by extending the OpenCable (J.83 Annex B) system 256QAM which is the standard of Korean and American cable television transmission to 1024QAM, and realize that the OpenCable 1024QAM has nearly 30% higher data rate than 256QAM at the expense of impractically higher TOV (Threshold of Visibility). To achieve practical TOV, we control code rates of inner convolutional coder and replace turbo coder in forward error correction (FEC) part, thereby analyzing the best performance of the OpenCable systems having conventional FEC. In that result, it is necessary to modify conventional FEC of the OpenCable system to achieve under 31.5dB TOV. Moreover we study the potential of UD-TV transmission via two or more TV channels, so called channel bonding, through the Shannon capacity in 6MHz channel and the relationship with next generation A/V codec technologies.

DFT-spread OFDM Communication System for the Power Efficiency and Nonlinear Distortion in Underwater Communication (수중통신에서 비선형 왜곡과 전력효율을 위한 DFT-spread OFDM 통신 시스템)

  • Lee, Woo-Min;Ryn, Heung-Gyoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.8A
    • /
    • pp.777-784
    • /
    • 2010
  • Recently, the necessity of underwater communication and demand for transmitting and receiving various data such as voice or high resolution image data are increasing as well. The performance of underwater acoustic communication system is influenced by characteristics of the underwater communication channels. Especially, ISI(inter symbol interference) occurs because of delay spread according to multi-path and communication performance is degraded. In this paper, we study the OFDM technique to overcome the delay spread in underwater channel and by using CP, we compensate for delay spread. But PAPR which OFDM system has problem is very high. Therefore, we use DFT-spread OFDM method to avoid nonlinear distortion by high PAPR and to improve efficiency of amplifier. DFT-spread OFDM technique obtains high PAPR reduction effect because of each parallel data loads to all subcarrier by DFT spread processing before IFFT. In this paper, we show performance about delay spread through OFDM system and verify method that DFT spread OFDM is more suitable than OFDM for underwater communication. And we analyze performance according to two subcarrier mapping methods(Interleaved, Localized). Through the simulation results, performance of DFT spread OFDM is better about 5~6dB at $10^{-4}$ than OFDM. When compared to BER according to subcarrier mapping, Interleaved method is better about 3.5dB at $10^{-4}$ than Localized method.

An improvement in FGS coding scheme for high quality scalability (고화질 확장성을 위한 FGS 코딩 구조의 개선)

  • Boo, Hee-Hyung;Kim, Sung-Ho
    • The KIPS Transactions:PartB
    • /
    • v.18B no.5
    • /
    • pp.249-254
    • /
    • 2011
  • FGS (fine granularity scalability) supporting scalability in MPEG-4 Part 2 is a scalable video coding scheme that provides bit-rate adaptation to varying network bandwidth thereby achieving of its optimal video quality. In this paper, we proposed FGS coding scheme which performs one more bit-plane coding for residue signal occured in the enhancement-layer of the basic FGS coding scheme. The experiment evaluated in terms of video quality scalability of the proposed FGS coding scheme by comparing with FGS coding scheme of the MPEG-4 verification model (VM-FGS). The comparison was conducted by analysis of PSNR values of three tested video sequences. The results showed that when using rate control algorithm VM5+, the proposed FGS coding scheme obtained Y, U, V PSNR of 0.4 dB, 9.4 dB, 9 dB averagely higher and when using fixed QP value 17, obtained Y, U, V PSNR of 4.61 dB, 20.21 dB, 16.56 dB averagely higher than the existing VM-FGS. From results, we found that the proposed FGS coding scheme has higher video quality scalability to be able to achieve video quality from minimum to maximum than VM-FGS.

Laterally Constrained Inversion of GREATEM data (지상 송신원 항공 전자탐사 자료의 횡적 제한 역산)

  • Cho, In-Ky;Jang, Je-Hun;Yi, Myeong-Jong;Rim, Hyoung-Rae
    • Geophysics and Geophysical Exploration
    • /
    • v.20 no.1
    • /
    • pp.33-42
    • /
    • 2017
  • Recently, the grounded electrical-source airborne transient electromagnetic (GREATEM) system with high power source was introduced to achieve deeper investigation depth and to overcome high noise level. Although the GREATEM is a transient electromagnetic system using a long grounded wire as the transmitter, GREATEM data have been interpreted with 1D earth models because 2D or 3D modeling and inversion of vast airborne data are complicated and expensive to calculate. Generally, 1D inversion is subsequently applied to every survey point and combining 1D images together forms the stitched conductivity-depth image. However, the stitched models often result in abrupt variations in neighboring models. To overcome this problem, laterally constrained inversion (LCI) has been developed in inversion of ATEM data, which can yield layered sections with lateral smooth transitions. In this study, we analysed the GREATEM data through 1D numerical modeling for a curved grounded wire source. Furthermore, we developed a laterally constrained inversion scheme for continuous GREATEM data based on a layered earth model. All 1D data sets and models are inverted as one system, producing layered sections with lateral smooth transitions. Applying the developed LCI technique to the GREATEM data, it was confirmed that the laterally constrained inversion can provide laterally smooth model sections that reflect the layering of the survey area effectively.

Analysis of the Signal Properties of Polycrystalline $HgI_2$ Film Detector under Radiographic Irradiation Condition (X-선촬영 조사 조건하에서 다결정 요오드화수은 박막검출기의 신호특성 분석)

  • Kim, Jong-Eon
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.289-294
    • /
    • 2010
  • The purpose of this study is an evaluation of the performance of a detector under radiographic irradiation condition by fabricating the polycrystalline $HgI_2$ film detector. The polycrystalline $HgI_2$ film detectors with thickness of 210 and $320\;{\mu}m$ were fabricated by screen print technology. Measurements of X-ray sensitivity and dark current were performed for two detectors. And measurements of the linearity of X-ray response and reproducibility were performed for the detector of thickness $320\;{\mu}m$. For applied electric field strengths from 0.05 to $2\;V/{\mu}m$ to the detector of thickness $320\;{\mu}m$, the X-ray sensitivities were measured from 233 to $1,408{\times}106\;electrons/mR{\cdot}mm^2$. And the dark currents were measured from 3.2 to $118\;pA/mm^2$. Compared with values reported by Zhong Su et al., the X-ray sensitivities exhibit about two times larger than the X-ray sensitivities measured by Zhong Su et al. And the dark currents exhibit about nine times larger than the dark currents measured by Zhong Su et al. The linearity of X-ray response acquired 0.988 as a coefficient of correlation (r). Reproducibility acquired 0.002 as a coefficient of variation. This study provides the performance data of fabricated polycrystalline $HgI_2$ film detector available for an active matrix flat panel imager under radiographic irradiation condition.

A New Bioluminescent Rat Prostate Cancer Cell Line: Rapid and Accurate Monitoring of Tumor Growth (효과적인 항암효능측정을 위한 발광 전립선 세포의 개발 및 평가)

  • Lee, Mi-Sook;Jung, Jae-In;Kwon, Seung-Hae;Shim, In-Sop;Hahm, Dae-Hyun;Han, Jeong-Jun;Han, Dae-Seok;Yoonpark, Jung-Han;Her, Song
    • Journal of Life Science
    • /
    • v.20 no.11
    • /
    • pp.1738-1741
    • /
    • 2010
  • Caliper measurements of tumor volume have been widely used in the assessment of tumors in animal models. However, experiments based on caliper data have resulted in unreliable estimates of tumor growth, due to necrotic areas of tumor mass. To overcome this systematic bias, we engineered a new luciferase-expressing rat prostate cancer cell line (MLL-Luc) that produces bioluminescence from viable cancer cells. MLL-Luc cells showed a strong correlation between bioluminescence intensity and cell number ($R^2$=0.99) and also accurately quantified tumor growth, with reduced bioluminescence signals caused by necrotic cells in a subcutaneous MLL-Luc xenograft model. The accurate quantification of tumor growth with bioluminescence imaging (BLI) was confirmed by a better antitumor effect of combination chemotherapy, compared to that based on caliper measurements with a correlation between the bioluminescence signal and tumor volume ($R^2$=0.84). These data suggest that bioluminescent MLL xenografts are a powerful and quantitative tool for monitoring tumor growth and are useful in evaluating the efficacy of anticancer drugs, with less systematic bias.