• Title/Summary/Keyword: 염소처리

Search Result 449, Processing Time 0.033 seconds

Simultaneous Control of Several Rice Insect Pests by Broadcasting Application of Granulated Insecticides (Terracur P, Lebaycid, and Gamma-BHC) (입제의 수면처리에 의한 주요수도해충의 동시방제)

  • Choi Seung Yoon;Bae Sang Hee;Song Yoo Han
    • Korean journal of applied entomology
    • /
    • v.9 no.1
    • /
    • pp.25-32
    • /
    • 1970
  • This experiment was conducted to find out the simultaneous control effect of granulated insecticides on the several major rice insect pests in Korea. The granulated insecticides used were Terracur P$5\%$ (one of the phosphoric insecticides), Lebaycid $5\%$, and Sang-gamma (gamma-BHC) $6\%$. Those insecticides were broadcasted by hand on the paddy field at the ratio of 3kg. in June and 4kg. in August per 10 a, and the date of insecticidal application was based on the maximum moth occurrence of the rice stem borer in 1969. The rice insect pests tested in this study were rice stem borer (Chilo suppressalis W.), green rice leafhopper (Nephotettix bipunctatus cincticeps U.), smiller brown planthopper (Laodelphax striatellus F.), and white back planthopper (Sogotella furcifera H.). For the study of residual effectiveness of the insecticides, the rice stem borer larvae just hatched from the eggs were installed on the sheath of rice plants collected from the paddy field after insecticidal treatment, and the mortality was made at 48 hours after installation. High mortality was observed in Terracur P and Sang-gamma treatments and low mortality in Lebaycid treatment. The duration of residual effects giving about 50% mortality was about 14 days in Sang-gamma and about 6 days in Terracur P treatments. The study on the effectiveness of the insecticides to the rice stem borer in the paddy field was made by the number of dead blades and white heads of the rice plants injured by the larvae, and the number of survival larvae in the straws after crop harvest. The order of insecticidal effectiveness to the rice stem borer was Terracur P=Sang-gamm>Lebaycid. The study on the effectiveness of the insecticides to the leafhoppers and planthoppers in the paddy field was made by the population density by sweeping (5 times) at the given day intervals after treatments. Terracur P was highly effective for the control of the green rice leafhoppers and Lebaycid was moderately effective, but Sang-gamma seemed not to be effective. The effectiveness of the insecticides tested to the planthoppers was not clear, and it seemed to related with the low insect population density. Study on the determination of proper timing of insecticidal application was not also made clear, and it seemed to be short in the range of day intervals in the insecticidal application. For the study on the control effects of the rice insect pests, rice yield per 100 hills per plot was observed. There was no statistically significant difference among the treatments in rice yields, but the order of yield (Terracur P>Sang-gamma>Lebaycid>Control) was paralleled with the tends of control effects above mentioned. In a view point of simultaneous control of the rice stem borers and green rice leafhoppers by the application of granulated insecticides, Terracur P and Lebaycid were more effective than Sang-gamma which have been used.

  • PDF

Evaluation of Cryptosporidiurn Disinfection by Ozone and Ultraviolet Irradiation Using Viability and Infectivity Assays (크립토스포리디움의 활성/감염성 판별법을 이용한 오존 및 자외선 소독능 평가)

  • Park Sang-Jung;Cho Min;Yoon Je-Yong;Jun Yong-Sung;Rim Yeon-Taek;Jin Ing-Nyol;Chung Hyen-Mi
    • Journal of Life Science
    • /
    • v.16 no.3 s.76
    • /
    • pp.534-539
    • /
    • 2006
  • In the ozone disinfection unit process of a piston type batch reactor with continuous ozone analysis using a flow injection analysis (FIA) system, the CT values for 1 log inactivation of Cryptosporidium parvum by viability assays of DAPI/PI and excystation were $1.8{\sim}2.2\;mg/L{\cdot}min$ at $25^{\circ}C$ and $9.1mg/L{\cdot}min$ at $5^{\circ}C$, respectively. At the low temperature, ozone requirement rises $4{\sim}5$ times higher in order to achieve the same level of disinfection at room temperature. In a 40 L scale pilot plant with continuous flow and constant 5 minutes retention time, disinfection effects were evaluated using excystation, DAPI/PI, and cell infection method at the same time. About 0.2 log inactivation of Cryptosporidium by DAPI/PI and excystation assay, and 1.2 log inactivation by cell infectivity assay were estimated, respectively, at the CT value of about $8mg/L{\cdot}min$. The difference between DAPI/PI and excystation assay was not significant in evaluating CT values of Cryptosporidium by ozone in both experiment of the piston and the pilot reactors. However, there was significant difference between viability assay based on the intact cell wall structure and function and infectivity assay based on the developing oocysts to sporozoites and merozoites in the pilot study. The stage of development should be more sensitive to ozone oxidation than cell wall intactness of oocysts. The difference of CT values estimated by viability assay between two studies may partly come from underestimation of the residual ozone concentration due to the manual monitoring in the pilot study, or the difference of the reactor scale (50 mL vs 40 L) and types (batch vs continuous). Adequate If value to disinfect 1 and 2 log scale of Cryptosporidium in UV irradiation process was 25 $mWs/cm^2$ and 50 $mWs/cm^2$, respectively, at $25^{\circ}C$ by DAPI/PI. At $5^{\circ}C$, 40 $mWs/cm^2$ was required for disinfecting 1 log Cryptosporidium, and 80 $mWs/cm^2$ for disinfecting 2 log Cryptosporidium. It was thought that about 60% increase of If value requirement to compensate for the $20^{\circ}C$ decrease in temperature was due to the low voltage low output lamp letting weaker UV rays occur at lower temperatures.

Effect of Plowing Frequency and Sowing Dates on the Agronomic Characteristics, Feed Value, Weed Yield and Palatability of Silage Corn (경운횟수와 파종기 이동이 사일리지용 옥수수의 생육특성, 사료가치, 잡초발생 및 가축의 기호성에 미치는 영향)

  • Lee, Sang-Moo;Kim, Byoung-Tae;Hwang, Joo-Hwan;Jeon, Byoung-Tae;Moon, Sang-Ho
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.27 no.3
    • /
    • pp.209-218
    • /
    • 2007
  • This experiment was conducted to investigate effect of plowing frequency and sowing dates on the agronomic characteristics, feed value, weed yield and palatability of silage corn. Treatments were a basal treatment(C: May 5 seeding, plowing once, weeding control once), T1(May 12 seeding, plowing twice, weeding control 0 time), T2(May 19 seeding, plowing three times, weeding control 0 time, T3(May 26 seeding, plowing four times, weeding control 0 time) and T4(June 2 seeding, plowing five times, weeding control 0 time). The experiment was performed at the College of Life and Natural Sciences of Sangju University in Sangju in 2006. The plant height and ear height showed highly in order to C > T1 > T2 > T3 > T4 treatment, leaf length was the highest at T2 (96.0cm). Leaf width and number of dead leaf were the highest at C and T3 (11.2cm), C, C and T1 (4.6), respectively. Stem diameter was the highest at T3 as 31mm, while T2 was the lowest as 25mm (p<0.05). Ear circle showed highly in order of C > T1 > T4 > T3 > T4 (p<0.05), and tip filling degree was the highest at C treatment as 8.8, while T4 treatment was the lowest as 6.0 (p<0.05). The stem hardness and grain hardness were C < T1 < T2 < T3 < T4 (p<0.05). Stem saccharinity was T1(6.1%) was the highest, while T2(3.0%) was the lowest(P<0.05). Fresh yield of weed was the lowest at C treatment as 500 kg/ha, but T1 treatment was the highest as 44,100 kg/ha (p<0.05). Weed coverage rate showed highly in order of T1 > T2 > T3 > T4 > C treatment (p<0.05). Fresh yield of corn was the highest at C treatment as T3,550 kg/ha, but T4 treatment was the lowest as 65,500 kg/ha (p<0.05). Dry matter yield of corn showed highly in order of C(26,978 kg/ha) > T1(26,130 kg/ha) > T2(20,255 kg/ha) > T3(20,255 kg/ha) > T4(17,508 kg/ha) treatment (p<0.05). Crude protein content was T1(7.69%) > T4(7.42%) > T2(6.34%) > T3(5.99%) > C(5.91%) treatment (p<0.05), and Crude fat content showed highly in order of C (2.13%) > T1(2.04%) > T2(1.96%) > T3(1.95%) > T4(1.84%) treatment. Relative palatability of Holstein, Korean native goat and spotted deer was the highest at C treatment, but Korean native cattle was the highest at T1 treatment.

Removing High Concentration Nitrogen by Electrolysis (전기분해에 의한 고농도 질소 제거의 특성)

  • Gil, Dae-Soo;Lee, Byung-Hun;Choi, Hae-Kyoung;Kwon, Dong-Min
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.2
    • /
    • pp.265-277
    • /
    • 2000
  • Laboratory experiments were conducted to investigate characteristics for removing ammonia-nitrogens by electrolysis methods. A stainless steel plate is used as the cathode and either $IrO_2{\backslash}Ti$ plate serves as the anode. Experiments were conducted to examine the effects of the operating conditions, such as the current density, retention time, electrode gap, $Cl^-/NH_4{^+}-N$ on the $NH_4{^+}-N$ removal efficiency. Possible optimum range for these operating variables are experimentally determined. The $NH_4{^+}-N$ removal efficiencies between plate type anode and net type anode were about same effect, but electrolytic power using net type anode is low than plate type anode. The $Cl^-/NH_4{^+}-N$ ratio was about $20.0kgCl^-/kgNH_4{^+}-N$ when $NH_4{^+}-N$ removal obtained 73 %, $Cl^-/NH_4{^+}-N$ ratio needs $27.6kgCl^-/kgNH_4{^+}-N$ so as to $NH_4{^+}-N$ completely remove. The removal efficiency of $NH_4{^+}-N$ increase with current density, retention time and $Cl^-/NH_4{^+}-N$ ratio, but decreased with increasing electrode gap. The relationship of operating conditions and $NH_4{^+}-N$ removal efficiencies are $$NH_4{^+}-N_{re}(%)=14.5364(Current\;density)^{0.7093}{\times}(HRT)^{1.0060}{\times}(Gap)^{-0.9926}{\times}(Cl^-/NH_4{^+}-N)^{1.0024}$$ With adding COD or/and alkalinity, relationships are $$NH_4{^+}-N_{re}(%)=9.8408(Current\;density)^{0.6232}{\times}(HRT)^{1.0534}$$ There existed a competition between the removals for $NH_4{^+}-N$ and $COD_{Cr}$ during electrolysis, the removal of $NH_4{^+}-N$ was shown to be dominant. $NH_4{^+}-N$ removal was high as addition of glucose and alkalinity.

  • PDF

Biocompatibility and Histopathologic Change of the Acellular Xenogenic Pulmonary Valved Conduit Grafted in the Right Ventricular Outflow Tract (우심실 유출로에 이식한 무세포화 이종 폐동맥 판막도관의 생체 적합성 및 조직병리학적 변화양상에 대한 연구)

  • 허재학;김용진;박현정;김원곤
    • Journal of Chest Surgery
    • /
    • v.37 no.6
    • /
    • pp.482-491
    • /
    • 2004
  • Background: The xenogenic or allogenic valves after in Vitro repopulation with autologous cells or in vivo repo-pulation after acellularization treatment to remove the antigenicity could used as an alternative to synthetic polymer scaffold. In the present study, we evaluated the process of repopulation by recipient cell to the acellu-larized xenograft treated with NaCl-SDS solution and grafted in the right ventricular outflow tract. Material and Method: Porcine pulmonary valved conduit were treated with. NaCl-SDS solution to make the grafts acellularized and implanted in the right ventricular outflow tract of the goats under cardiopulmonary bypass. After evaluating the functions of pulmonary valves by echocardiography, goats were sacrificed at 1 week, 1 month, 3 months, 6 months, and 12 months after implantation, respectively. After retrieving the implanted valved conduits, histopathologic examination with Hematoxylin-Eosin, Masson' trichrome staining and immunohistochemical staining was performed. Result: Among the six goats, which had been implanted with acellularized pulmonary valved conduits, five survived the expected time period. Echocardiographic examinations for pulmonary valves revealed good function except mild regurgitation and stenosis. Microscopic analysis of the leaflets showed progressive cellular in-growth, composed of fibroblasts, myofibroblasts, and endothelial cells, into the acellularized leaflets over time. Severe inflammatory respon-se was detected in early phase, though it gradually decreased afterwards. The extracellular matrices were regenerated by repopulated cells on the recellularized portion of the acellularized leaflet. Conclusion: The acellularized xenogenic pulmonary valved conuits were repopulated with fibroblasts, myofibroblasts, and endothelial cells of the recipient and extracellullar matrices were regenerated by repopulted cells 12 months after the implantation. The functional integrity of pulmonary valves was well preserved. This study showed that the acellularized porcine xenogenic valved conduits could be used as an ideal valve prosthesis with long term durability.

Evaluation of Grade-Classification of Wood Waste in Korea by Characteristic Analysis (국내 폐목재 특성분석을 통한 등급화 평가)

  • Kim, Joung-Dae;Park, Joon-Seok;Do, In-Hwan;Hong, Soo-Youl;Oh, Gil-Jong;Chung, David;Yoon, Jung-In;Phae, Chae-Gun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.11
    • /
    • pp.1102-1110
    • /
    • 2008
  • This research was performed to analyze the characteristics of wood wastes from origin and to suggest grade-classification for them. Korean proximate analysis was conducted, and heating value, heavy metals and Cl concentrations were analyzed for gradeclassification. Wood wastes were sampled from forest, living, construction and demolition, and industrial areas with origin. Moisture content of most wood wastes was ranged in 5$\sim$10%. VS (volatile solids) and ash contents of them showed > 95% and < 5%, respectively. Most wood wastes except wood for growing mushroom permitted the standard (low heating value $\geq$ 3,500 kcal/kg) for refusederived fuel. CCA (Cr, Cu, As) concentration of wood wastes used in bench, wasted fishing boat, and railroad crosstie was higher than that of the other ones. Cl content showed approximately 1.3% in wood box for fish and $\leq$ 0.2% in the other wood wastes. Cl content of all wood wasted used in this research permitted the standard (Cl $\leq$ 0.2%, dry weight basis) for refuse-derived fuel. If the wood wastes were classified in 3-grade, plywoods would be in 2nd grade, and MDF (medium density fiber), wooden bench, painted electric wire drum, wasted fishing boat, and railroad crosstie be in 3rd grade.

Analysis of Bacterials Community Structure in Leadchate-Contaminated Groundwater using Denaturing Gradient Gel Electrophoresis (Denaturing Gradient Gel Electrophoresis를 이용한 매립지 침출수로 오염된 지하수의 세균 군집 분석)

  • Kim Jai-Soo;Kim Ji-Young;Koo So-Yeon;Ko Kyung-Seok;Lee Sang-Don;Cho Kyung-Suk;Koh Dong-Chan
    • Microbiology and Biotechnology Letters
    • /
    • v.34 no.2
    • /
    • pp.166-173
    • /
    • 2006
  • This research has been performed to clarify the relationship between hydrogeochemistry and bacterial community structure in groundwater contaminated with landfill leachate. We collected and analyzed samples from 5 sites such as leachate (KSG1-12), treated leachate (KSG1-16), two contaminated groundwaters (KSG1-07 and KSG1-08) and non-contaminated groundwater (KSG1-13). pH was 8.83, 8.04, 6.87, 6.87 and 6.53 in order; redox potential (Eh) 108, 202, 47, 200 and 154 mV; electric conductivity (EC) 3710, 894, 1223, 559 and 169.9 $\mu$S/cm; suspended solids (SS) 86.45, 13.74, 4.18, 0.24 and 11.91 mg/L. In KSG01-12, the ion concentrations were higher especially in $Cl^-$ and $HCO_3^-$ than other sites. The concentrations of Fe, Mn and $SO_4^{2-}$ were higher In KSG1-07 than in KSG1-08, and vise versa in $NO_3^{2-}$. In the comparison of DGGE fingerprint patterns, the similarity was highest between KSG1-13 and KSG1-16 (57.2%), probably due to common properties like low or none contaminant concentrations. Otherwise KSG1-08 showed lowest similarities with KSG1-13 (25.8%) and KSG1-12 (27.6%), maybe because of the degree of contamination. The most dominant bacterial species in each site were involved in $\alpha$-Proteobacteria (55.6%) in KSG1-12, $\gamma$-Proteobacteria (50.0%) in KSG1-16, $\beta$-Proteobacteria (66.7%) in KSG1-07, $\gamma$-Proteobacteria (54.5%) in KSG1-08 and $\beta$-Proteobacteria (36.4%) in KSG1-13. These results indicate that the microbial community structure might be changed according to the flow of leachate in grounderwater, implying changes in concentrations of pollutants, available electron accepters and/or other environmental conditions.

Prediction of Energy Requirements for Maintenance and Growth of Female Korean Black Goats (번식용 교잡 흑염소의 유지와 성장을 위한 대사에너지 요구량 추정)

  • Lee, Jinwook;Kim, Kwan Woo;Lee, Sung Soo;Ko, Yeoung Gyu;Lee, Yong Jae;Kim, Sung Woo;Jeon, Da Yeon;Roh, Hee Jong;Yun, Yeong Sik;Kim, Do Hyung
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.39 no.1
    • /
    • pp.1-8
    • /
    • 2019
  • This study was conducted to predict the energy requirements for maintenance and growth of female Korean black goats during their growth and pregnancy phases. Fifty female goats ($18.7{\pm}0.27kg$) in their growth phase with an average age of 5 months were stratified by weight and randomly assigned into 5 groups. They were fed 5 diets varying in metabolic energy (ME) [2.32 (G1), 2.49 (G2), 2.74 (G3), 2.99 (G4), and 3.24 (G5) Mcal/kg] until they were 9-month-old. After natural breeding, 50 female goats ($30.7{\pm}0.59kg$) were stratified by weight and randomly assigned into 5 groups. They were fed 5 diets varying in ME [2.32 (P1), 2.43 (P2), 2.55 (P3), 2.66 (P4), and 2.78 (P5) Mcal/kg]. The average feed intake ranged between 1.5 and 2.0% of the body weight (BW), and there was no significant difference between the treatment groups with goats in growth or pregnancy phases. Average daily gain (ADG) in diet demand during the growth phase increased with an increasing ME density and ranged from 46 to 69 g/d (p<0.01). Feed conversion ratio (FCR) improved with the ME density during the growth phase (p<0.01). The intercept of the regression equation between ME intake and ADG indicated that energy requirement for maintenance of goats during growth and pregnancy phases was $103.53kcal/BW^{0.75}$ and $102.7kcal/BW^{0.75}$, respectively. These results may serve as a basis for the establishment of goat feeding standards in Korea. Further studies are required to assess the nutrient requirement of goats using various methods for improving accuracy.

Management of Critical Control Points to Improve Microbiological Quality of Potentially Hazardous Foods Prepared by Restaurant Operations (외식업체에서 제공하는 잠재적 위험 식품의 미생물적 품질향상을 위한 중점관리점 관리방안)

  • Chun, Hae-Yeon;Choi, Jung-Hwa;Kwak, Tong-Kyung
    • Korean journal of food and cookery science
    • /
    • v.30 no.6
    • /
    • pp.774-784
    • /
    • 2014
  • The purpose of this study was to present management guidelines for critical control points by analyzing microbiological hazardous elements through screening Potentially Hazardous Foods (PHF) menus in an effort improve the microbiological quality of foods prepared by restaurant operations. Steamed spinach with seasoning left at room temperature presents a range of risk temperatures which microorganisms could flourish, and it exceeded all microbiological safety limits in our study. On the other hand, steamed spinach with seasoning stored in a refrigerator had Aerobic Plate Counts of $2.86{\pm}0.5{\log}\;CFU/g$ and all other microbiological tests showed that their levels were below the limit. The standard plate counts of raw materials of lettuce and tomato were $4.66{\pm}0.4{\log}\;CFU/g$ and $3.08{\pm}0.4{\log}\;CFU/g$, respectively. Upon washing, the standard plate counts were $3.12{\pm}0.6{\log}\;CFU/g$ and $2.10{\pm}0.3{\log}\;CFU/g$, respectively, but upon washing after chlorination, those were $2.23{\pm}0.3{\log}\;CFU/g$ and $0.72{\pm}0.7{\log}\;CFU/g$, respectively. The standard plate counts of baby greens, radicchio and leek were $6.02{\pm}0.5{\log}\;CFU/g$, $5.76{\pm}0.1{\log}\;CFU/g$ and $6.83{\pm}0.5{\log}\;CFU/g$, respectively. After 5 minutes of chlorination, the standard plate counts were $4.10{\pm}0.6{\log}\;CFU/g$, $5.14{\pm}0.1{\log}\;CFU/g$ and $5.30{\pm}0.3{\log}\;CFU/g$, respectively. After 10 minutes of chlorination treatment, the standard plate counts were $2.58{\pm}0.3{\log}\;CFU/g$, $4.27{\pm}0.6{\log}\;CFU/g$, and $4.18{\pm}0.5{\log}\;CFU/g$, respectively. The microbial levels decreased as the time of chlorination increased. This study showed that the microbiological quality of foods was improved with the proper practices of time-temperature control, sanitization control, seasoning control, and personal and surface sanitization control. It also presents management guidelines for the control of potentially hazardous foods at the critical control points in the process of restaurant operations.