• Title/Summary/Keyword: 열 복사

Search Result 730, Processing Time 0.02 seconds

Combustion Characteristics and Performance of U type Radiation Tube Burner (U형 복사튜브 버너 연소특성 및 성능실험)

  • Lee, Hyun-Chan;You, Hyun-Seok;Lee, Joong-Seong
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.710-714
    • /
    • 2000
  • Present study deals with combustion characteristics and performance of U type radiation tube burner which combustion capacity is 30,000kcal/he and the maximum capacity of supply fuel is $3.0N m^3/hr$. Temperature range of radiation tube is maximum $170^{\circ}C$ and minimum $150^{\circ}C$ and this displays relatively small temperature range. And thermal efficiency is satisfactory as $75{\sim}80%$. Also, radiative efficiency of radiation tube is $52{\sim}63%$.

  • PDF

Study on Mathematical Method of Radiation Heat Transfer for Estimating Width of Firebreak in Surface Fire (복사열전달 수치해석을 통한 지표화 방화선 구축 폭 산정에 관한 연구)

  • Kim, Dong-Hyun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.6
    • /
    • pp.59-64
    • /
    • 2010
  • Building a firebreak against surface forest fire is a typical indirect suppression method that stops spread of flame by removing surface fuel, such as fallen leaves and bushes. In the sense of fire dynamic, building a firebreak is to set a section which will block thermal energy from igniting on virgin fuel. This study suggests and evaluates a calculation method for width of firebreak against surface fire for variant wind and slope conditions by applying the Point Source Model (PSM) to fallen leaves of Pinus densiflora. Width of firebreak was measured based on the distance the threshold radiant heat igniting Pinus densiflora fallen leaves at the heat flux of $4.9\;kW/m^2$ reaches. As a result, at the wind velocity of 0~5 m/s and on the slope of $0{\sim}50^{\circ}$, the appropriate width of a firebreak was 0.35~0.65 m for the mean flame height and 0.75~1.05 m for the maximum flame height. Accordingly, considering the factor of safety, the most appropriate width of a firebreak is 1.05 m based on the maximum flame height. Additional comparative analyses through experiments and field surveys are deemed necessary to determine appropriate widths of firebreak for different types of surface fuel.

Impact Range Analysis of Small LPG Storage Tank Explosions at Highway Rest Areas (고속도로 휴게소 소형 LPG 저장탱크 폭발에 따른 영향범위 분석)

  • Seung duk Jeon;Soon Beom Lee;Jai Young Lee
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.6
    • /
    • pp.319-327
    • /
    • 2023
  • This study analyzes the risks of explosions of small LPG storage tanks installed at highway rest areas. For this purpose, the ranges of the effect of thermal radiation and overpressure caused by the BLEVE(Boiling Liquid Expansion Vapor Explosion)and VCE(Vapor Cloud Explosion) of a 2900-kg small LPG storage tank installed at highway rest areas were quantitatively evaluated by applying the Areal Location of Hazardous Atmospheres program. The ranges of influence of the derived explosion overpressure and thermal radiation were found to have a maximum radii of 336 m and 423 m, respectively. The study determined that those within 269 m could be severely injured by an explosion overpressure of 3.5 psi, and fatalities from thermal radiation of 10 kw/m2 could occur within 192 m of the exploded storage tank. The safety management plan for the LPG storage tank was discussed while considering the auxiliary facilities of highway rest areas and the extent of the damage impact. These research results will help improve safety accident prevention regulations considering the environment and facilities of the rest areas as well as the safety management of small LPG storage tanks installed at highway rest areas.

Infouences of the Asian Monsoon and the Kuroshio on the Sea Surface Temperatures in the Yellow, the Japan and the East China Seas (아시아 季節風과 쿠로시오가 黃海, 東海 및 東支那海의 表面水溫에 미치는 影響)

  • 강옥균
    • 한국해양학회지
    • /
    • v.20 no.2
    • /
    • pp.1-9
    • /
    • 1985
  • A simple analytic model of the sea surface temperature(SST) is developed in order to understand the effects of the Asian monsoon and the Kuroshio on the annual variations of SST by the Asian monsoon is almost in phase with the incoming radiation whereas that by the Kuroshio is out of phase with the incoming radiation. In the Yellow Sea, due to the heat advection by the Asian monsoon, the yearly mean SST is low and the annual range of SST exceeds 20$^{\circ}C$. The annual range of SST in the northwestern Japan Sea is large because of the combined effects of the Asian monsoon and the cold water advection. In the Kuroshio and in the Tsushima Current regions, the annual range of SST is small and the mean SST is high due to the heat advection by warm currents.

Thermo-structural Analysis for Radiation-Cooled Nozzle Extension of Thrust Chamber (복사냉각방식 연소기 노즐확장부 열/구조해석)

  • Ryu, Chul-Sung;Lee, Keum-Oh;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.291-295
    • /
    • 2011
  • Thermo-structural analysis was performed for a radiation-cooled nozzle extension of thrust chamber. A Niobium alloy that is known to be a high-performance refractory alloy was used. Since area ratio of the nozzle extension is larger than that of nozzle divergence part, its size also becomes larger. For this reason, it is important to minimize the thickness of nozzle extension to reduce its weight. For the purpose of weight minimization, the thickness of nozzle extension was varied from 1.0 mm to 0.4 mm and structural stability was evaluated for each case. Analysis results showed that nozzle extension with thickness of 0.4 mm is structurally stable for the operation condition. The effect of combustion-included vibration will be additionally considered in the future.

  • PDF

The Premixed Flame in a Radiatively Active Porous Medium (복사열전달을 동반하는 다공성 매질내의 예혼합 화염)

  • 김정수;백승욱
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.2
    • /
    • pp.265-270
    • /
    • 1989
  • The present study considers the thermal structure variation in a porous medium caused by changing the most important radiative property of porous medium, absorption coefficient, as well as altering the physical dimension of porous medium and the equivalence ratio of premixed gas mixture. The radiation model was introduced as an unsteady differential form using the two-flux gray radiation model. The role of the conductive heat transfer through both gas phase and porous medium was found to be almost insignificant compared with that of the radiative heat transfer. The reaction zone shifted upstream and the flame thickness decreased as either the geometrical length of porous medium increased or the absorption coefficient decreased.

A Quantitative Analysis on the Extinguishing Mechanism of Laminar Diffusion Flames by $CO_2$ ($CO_2$에 의한 층류 확산화염의 소화기구에 관한 정량적 분석)

  • Mun, Sun-Yeo;Hwang, Cheol-Hong;Oh, Chang-Bo;Park, Won-Hee
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.378-381
    • /
    • 2011
  • 대표적 가스계 소화약제인 $CO_2$의 소화기구(Extinguishing mechanism)를 재조명하기 위하여, $CH_4$/air 저 신장율 대향류 확산화염을 대상으로 $CO_2$가 소화에 미치는 영향에 대한 수치해석이 수행되었다. 부력이 지배적인 화염의 소화현상은 복사 열손실에 의해 큰 영향을 받기 때문에, 소화농도 예측에 대한 복사모델의 성능평가가 우선적으로 이루어졌다. 주요 결과로서, 공기류에 첨가된 $CO_2$의 소화농도는 복사모델이 고려되지 않은 경우 과다 예측되는 반면에, 간략화된 광학적으로 얇은 근사(Optically thin approximation) 모델과 비교적 높은 정확도를 갖는 좁은 밴드(Statistical narrow band) 모델은 실험의 오차범위 내에서 큰 차이를 보이지 않았다. $CO_2$가 소화에 미치는 순수 희석효과, 희석에 의한 복사효과, 화학적 효과 및 열적효과를 정량적으로 분석하기 위하여 가상의 소화약제의 개념을 도입하였다. 이를 통해 화염의 총괄신장율에 따른 $CO_2$ 소화효과에 대한 구체적인 이해가 시도되었다.

  • PDF

Development of Energy Efficient Smart Module with Variable Direction of Heat Flow, Heat Capacity and Surface Absorptivity (Thermo-Diode식 태양열 이용 모듈(Smart Module)개발)

  • Lee, K.J.;Chun, W.G.
    • Solar Energy
    • /
    • v.18 no.3
    • /
    • pp.119-128
    • /
    • 1998
  • This study has been carried out to develop a thermo-diode system capable of adjusting heat flow direction, solar absorptivity and thermal capacity. What we call "Smart Module" here has emerged from a series of repeated processes involving design, construction and test. In all, it is found that liquid thermo-diode systems are viable in harnessing the sun's energy. The module can be applied for space heating in winter and reduce the cooling load of buildings in summer.

  • PDF

Research on Fire Safety of Mortar-Containing Waste Tire Powders and Flame Retardant (폐타이어 분말과 난연제가 혼입된 모르타르의 화재안전에 관한 연구)

  • Park, Jeong-Jin;Son, Ki-Sang
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.12-17
    • /
    • 2010
  • The purpose of this study is to determine how effectively waste tire recycled material mixed with flame retardant work in combating fire. As discovered in the previous study, waste tire mixed with cement mortar has more insulation capacity. However, this mortar is weak against fire. Therefore flame retardant, with a specific proportional mix, will be added to increase its fire prevention capacity. Tests will be made in accordance with ISO 5657 procedures for measuring fire ignition time, flame and shape variation of test pieces at the Building Material Test Institute. The test piece will be set up with horizontal levels having a constant radiation heat of $1{\sim}5W/cm^2$. Temperature transfers and increases from the surface into the interior. Combustible gases result due to pyrolysis, and regular contact is maintained between the fire source and the center of the test piece for assessment purposes. Ignition has not been occurred without adding retardant meaning that there is almost no possibility of ignition of waste tire particle. This fact can be considered as fire load to appreciate a volume of combustion materials. Flame is not occurred due to heat-absorbing effect by adding non-organic series retardant into waste tire particle. Conclusions have been summarized as follows; 1) Combustion of building material can be decreased by adding retardant to waste tire-mixing mortar. But compressive strength and insulation capacity of the material should be measured later. 2) Firing prevention and ignition are main points of building fire. Reasonable fire engineering assessment of interior material should be made for establishing effective disaster prevention system.

A Study on Fire Explosion Characteristics via Physico-chemical Analysis of Petroleum Residues (석유 부산물의 물리화학적 분석을 통한 화재폭발 특성연구)

  • Kim, Hyeonggi;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.30 no.5
    • /
    • pp.556-561
    • /
    • 2019
  • In this study, the physical and chemical analyses of petroleum residues (pyrolized fuel oil, PFO) were conducted and major components were selected to investigate their fire and explosion characteristics. Major component distribution areas of the PFO were identified via the GC-SIMDIS and MALDI-TOF analyses. In addition, the qualitative analysis of major component distribution areas was performed by GC-MS analysis. Major components of pyrolysis residue were selected based on the results of various analyses such as EA, SARA and TGA. As a result, benzene, toluene and xylene were selected as major components. Finally, the process hazard analysis software tool (PHAST) analysis was performed to investigate the range of maximum damage effect in case of fire and explosion. Toluene presented the highest risk due to the radiation effect of $227kW/m^2$ and 118 m in the case of jet fire. Xylene and benzene showed the maximum radiant heat values of 114 and $151kW/m^2$, respectively. It was also confirmed from the analysis of pasquill stability and wind speed that the radiant heat increased up to 55% according to wind speed in benzene, which was considered to be a main factor increasing the influence range.