• Title/Summary/Keyword: 열형광선량계(TLD)

Search Result 90, Processing Time 0.03 seconds

Comparison on the Dosimetry of TLD and OSLD Used in Nuclear Medicine (광자극발광선량계와 열형광선량계를 이용한 핵의학과 선량 측정비교)

  • Lee, Wang-Hui;Kim, Sung-Chul;Ahn, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.12
    • /
    • pp.329-334
    • /
    • 2012
  • For the dosimetry of the radiation workers, film badge, Thermo Luminescent Dosimeter (TLD), and glass dosimeter are being used and recently, there is a growing trend of using Optically Stimulated Luminescence Dosimeter (OSLD) in the world. However, OSLD is only being applied some of the field in Korea and there has been almost no study made related to OSLD. Thus, the accumulated radiation dose of TLD and OSLD that have been most frequently used in the field was compared in the radiation workers of nuclear medicine and their working areasfor 3 months. As a result, the average surface dose showed 0.85 mSv difference with 1.27 mSv for TLD and 2.12 mSv for OSLD while having 0.73 mSv difference for the average depth dose with 1.33 mSv for TLD and 2.06 mSv for OSLD. The surface dose and depth dose of OSLD showed statistically significant result with higher measurement (p<0.05).

Evaluation of Usability and Radiation Dose Measurement Using Personal Radiation Exposure Dosimeter (방사선 개인피폭선량계를 이용한 피폭선량 측정 및 유용성 평가)

  • Kang, In-Seog;Ahn, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.11
    • /
    • pp.864-870
    • /
    • 2014
  • To propose a basis for the selection of personal dosimeters to measure radiation dose administration of radiation workers as a way to evaluate the usefulness dosimeter. For the dosimetry of the radiation workers 2012, during 1 year, 30 were radiation workers to measure personal dose. By personal exposure is measured cumulative dose, is investigated the performance of the TLD, PLD, OSLD. And comparing the measured value of each dosimeter dose and analyzed. Medical institutions, inspection work and quarterly confirmed the cumulative exposure dose of radiation workers. Using DAP and Ion-Chamber, to measure to compare TLD, PLD, OSLD dosimeter performance. A comparison of the directly through the X-ray dosimeter and The absolute value of the Ion-Chamber, OSLD more similar than in the TLD and PLD showed the dose values so the excellent ability to measure the results. Also in radiation generating area dose of radiation workers is higher than that in OSLD. Consequently, in terms of the individual exposure management OSLD is appropriated and beneficial than others.

TLD dose variation of Magnetic Resonance Imaging Equipment (자기공명영상장비에서 열형광선량계의 선량 변화)

  • Je, Jaeyong;Kang, Eunbo
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.473-476
    • /
    • 2012
  • The PET-MRI which has been installed and being managed recently uses both magnetic field and radiation. Most radiation workers wear a thermoluminescenct dosimeter (TLD) as a personal radiation dosimeter, and the TLD is affected both by a magnetic field and radiation. In this research, the same amount of X-ray was applied to 36 TLDs, and the changes in the dose of the 32 TLDs exposed to magnetic field at the location where its intensity of the magnetic resonance imaging (MRI) was about 5000 Gauss for eight hours with one-hour unit and that of the four TLDs not exposed to magnetic field were compared and checked. The measurement result showed that exposure dose of the TLD attached to the MRI changed irregularly depending on the amount of exposure time. Therefore, the TLD whose amount of changes little in the environment of a MRI is demanded to be developed.

전신방사선조사(TBI)시 다이오드측정기(Diode detector) 및 열형광선량계(TLD)를 이용하여 측정한 골조직 선량감쇠에 대한 고찰

  • 임현실;이정진;장인기;김완선
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.29 no.1
    • /
    • pp.6-11
    • /
    • 2003
  • 목적 : 전신방사선조사(TBI)시 균등한 선량을 조사할 목적으로 사용되는 각 신체부위별 보상체(compensator) 두께의 결정은 열형광선량계(TLD)를 이용하여 표면선량(surface dose)을 측정하고, 심부선량(depth dose)으로 환산하는 방법을 주로 이용한다. 그러나 이와 같은 방법은 골(bone) 조직에 대한 선량감쇠(dose attenuation)의 영향이 고려되지 않아 신체중심부에서의 정확한 심부선량을 알 수가 없다. 이에 본 연구

  • PDF

Development of Algorithm for Evaluation of the Dose with Thermoluminescence Dosimeter (열형광선량계에 의한 선량평가 알고리즘 개발)

  • Song, Myung-Jae;Kim, Hee-Keun;Ha, Chung-Woo;Lee, Tae-Young;Yoon, Suk-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.17 no.2
    • /
    • pp.1-13
    • /
    • 1992
  • The purpose of this study is to develop an algorithm of TLD dose evaluation to meet all requirements stated in ANSI N13. 11-1983. It made the PB-3 TLD of Teledyne Isotopes an object of the development. Personal dosimetry performance testings of the development algorithm have been performed twice through the Atlan-Tech, INC. in accordance with the criteria of testing described in ANSI N13. 11-1983. As ,a result, it is assured that the developed algorithm has complied with all requirements stated in ANSI N13. 11-1983.

  • PDF

A study on dose attenuation in bone density when TBI using diode detector and TLD (전신방사선조사(TBI)시 다이오드 측정기(Diode detector) 및 열형광선량계(TLD)를 이용한 골조직 선량감쇄에 대한 고찰)

  • IM Hyun Sil;Lee Jung Jin;Jang Ahn Ki;Kim Wan Seon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.67-77
    • /
    • 2003
  • I. Purpose Uniform dose distribution of the whole body is essential factor for the total body irradiation(TBI). In order to achieved this goal, we used to compensation filter to compensate body contour irregularity and thickness differences. But we can not compensate components of body, namely lung or bone. The purpose of this study is evaluation of dose attenuation in bone tissue when TBI using diode detectors and TLD system. II. Materials and Methods The object of this study were 5 patients who undergo TBI at our hospital. Dosimetry system were diode detectors and TLD system. Treatment method was bilateral and delivered 10MV X-ray from linear accelerator. Measurement points were head, neck, pelvis, knees and ankles. TLD used two patients and diode detectors used three patients. III. Results Results are as followed. All measured dose value were normalized skin dose. TLD dosimetry : Measured skin dose of head, neck, pelvis, knees and ankles were $92.78{\pm}3.3,\;104.34{\pm}2.3,\;98.03{\pm}1.4,\;99.9{\pm}2.53,\;98.17{\pm}0.56$ respectably. Measured mid-depth dose of pelvis, knees and ankles were $86{\pm}1.82,\;93.24{\pm}2.53,\;91.50{\pm}2.84$ respectably. There were $6.67\%{\sim}11.65\%$ dose attenuation at mid-depth in pelvis, knees and ankles. Diode detector : Measured skin dose of head, neck, pelvis, knees and ankles were $95.23{\pm}1.18,\;98.33{\pm}0.6,\;93.5{\pm}1.5,\;87.3{\pm}1.5,\;86.90{\pm}1.16$ respectably. There were $4.53\%{\sim}12.6\%$ dose attenuation at mid-depth in pelvis, knees and ankles. IV. Conclusion We concluded that dose measurement with TLD or diode detector was inevitable when TBI treatment. Considered dose attenuation in bone tissue, We must have adequately deduction of compensator thickness that body portion involved bone tissue.

  • PDF

Relative ratio about dose value of thermoluminescence and optical stimulated luminescence dosimeter according to exposed condition in diagnostic radiation (진단방사선의 노출 조건에 따른 열형광선량계와 광자극형광 선량계의 선량값 상대비)

  • Kang, Yeonghan;Kwon, Soonmu;Kim, BooSoon
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.499-505
    • /
    • 2012
  • The purpose of this study was to find out the difference of radiation dose value through energy, exposure number, fluoroscopy time, the number of days of exposed scatter X-ray when TLD and OSLD is used in diagnostic radiology. The difference of value were measured by relative ratio and interval. Energy makes high relative ratio of TLD($1.81{\pm}0.41$) than OSLD($1.40{\pm}0.26$), exposure number makes high of OSLD($1.40{\pm}0.26$) than TLD($2.10{\pm}0.10$). There are no significant differences between relative ratio of TLD and OSLD in fluoroscopy time and the number of days of exposed scatter X-ray. But interval of relative ratio in the number of days of exposed scatter X-ray was narrowed in less 0.2. That means, the measurement of scatter X-ray could more confident in TLD and OSLD than the measurement of direct ray. In conclusion, we have to recognize the relative ratio of TLD and OSLD could be vary depending on exposed condition of radiation. And in some cases, double test of TLD and OSLD get more creditable results of dose value.

Quality Assurance Program of Electron Beams Using Thermoluminescence Dosimetry (열형광선량계를 이용한 전자선 품질보증 프로그램에 관한 연구)

  • Rah Jeong-Eun;Kim Gwe-Ya;Jeong Hee-Kyo;Shin Dong-Oh;Suh Tae-Suk
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.62-69
    • /
    • 2005
  • The purpose of this study has been performed to investigate the possibility of external audit program using thermoluminescence dosimetry for electron beam in korea. The TLD system consists of LiF powder, type TLD-700 read with a PCL 3 reader. In order to determine a calibration coefficient of the TLD system, the reference dosimeters are irradiated to 2 Gy in a $^{60}CO$ beam at the KFDA The irradiation is performed under reference conditions is water phantom using the IAEA standard holder for TLD of electron beam. The energy correction factor is determined for LiF powder irradiated of dose to water 2 Gy in electron beams of 6, 9, 12, 16 and 20 MeV (Varian CL 2100C). The dose is determined according to the IAEA TRS-398 and by measurement with a PTW Roos type plane-parallel chamber. The TLD for each electron energy are positioned in water at reference depth. In this study, to verify of the accuracy of dose determination by the TLD system are performed through a 'blind' TLD irradiation. The results of blind test are $2.98\%,\;3.39\%\;and\;0.01\%(1\sigma)$ at 9, 16, 20 MeV, respectively. The value generally agrees within the acceptance level of $5\%$ for electron beam. The results of this study prove the possibility of the TLD quality assurance program for electron beams. It has contributed to the improvement of clinical electron dosimetry in radiotherapy centers.

  • PDF

The Effects of Magnetic Field on TLD Glow Curve (자기장이 열형광선량계의 글로우 곡선에 미치는 영향)

  • Je, Jaeyong;Kang, Eunbo
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.6
    • /
    • pp.415-418
    • /
    • 2013
  • Thermoluminescent dosimeter utilizes the fact that when irradiated specimen is heated up, some part of the absorbed energy is emitted from the specimen as light with longer wavelength. This research aims at analyzing the glow curves of four TLD-100 exposed to a magnetic field and those of other four TLD-100 not exposed to one by treating them with heat and irradiating them, which are commonly used as thermoluminescent dosimeter, in the same condition. As the result of the experiment, regarding the electrons captured by irradiation, some of the electrons of lower traps were combined with positive holes of valence band through the exposure to a magnetic field, and the peak size decreased by 48%. The reduction in the size of the lower traps caused the TLD-100 exposed to a magnetic field to display a low level of dose. In addition, low traps estimated activation energies are 1.6 eV and 1.5 eV.

A study on the effects of scattering dose on eyes and thyroid for panoramagraphy - Focus on TLD and PLD - (파노라마 촬영시 눈과 갑상선에 미치는 표면선량에 관한 연구 - TLD, PLD 중심으로 -)

  • Dong, Kyung-Rae
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1118-1123
    • /
    • 2009
  • Ten hospitals from the Gwangju area were used to examine shallow dose to eyes and thyroid from panoramagraphy. Thermoluminescent dosimeter (TLD) and Photoluminescent dosimeter (PLD) were used as measurement devices at each hospital. ICRP 60 and ICRP 73 set standards for acceptability for eyes at 15mSv and thyroid at 1mSv per year. Left eye measures with TLD and PLD resulted in 0.19mSv and 0.24mSv respectively. Right eye measures with TLD and PLD resulted in 0.23mSv and 0.25mSv respectively. Thyroid measures with TLD and PLD resulted in 0.08mSv and 0.25mSv respectively with both measures not exceeding standards for acceptance. There was a significant difference in comparing the left eye and thyroid for TLD and PLD (p<0.01). There was no significant difference with the right eye (p>0.05). The absorbed dose measurements for eyes and thyroid using TLD and PLD in regards to panorama devices at each hospital were within the ICRP 60 recommendations; however, with the possibility of stochastic effect, all dose levels were taken into consideration.

  • PDF