• Title/Summary/Keyword: 열탈착

Search Result 121, Processing Time 0.022 seconds

Modeling of thermal fluidized desorption for diesel-oil contaminated soils (Diesel-oil에 오염된 토양의 유동상 열탈착 모델링)

  • 이상화;김병욱;이상득;박달근;이중기
    • Journal of Korea Soil Environment Society
    • /
    • v.4 no.2
    • /
    • pp.137-147
    • /
    • 1999
  • Fluidized-bed thermal desorber coupled with a heat pipe was investigated for the remediation of soil contaminated with diesel oils. Thermal gravimetric analysis by Cahn-balance indicated that the desorption of diesel oils from the soil particles was mainly governed by the internal diffusion at low concentration of less than 0.5 wt. % of oils in the soil particles. In fluidized-bed experiments. increase of fluidizing gas velocity reduced the residual oils of the contaminated soils, the increase of soil feed rate decreased efficiency of fluidized-bed desorber. A mathematical model was developed by incorporating Fickian diffusion kinetics into the Kunii-Levenspiel model Simulation results showed reasonable agreement for the performance of fluidized-bed thermal desorber.

  • PDF

로터리킬른 및 열적 2차 처리를 이용한 유류오염토양의 고효율처리 특성연구

  • 장주호;동종인;엄권욱
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.52-56
    • /
    • 2004
  • 이 연구는 유류에 오염된 토양의 복원과정에서 적용된 열탈착 공법의 타당성과 효율적인 운전을 위해 수행되었다. 여러 열탈착공법 중 로터리킬른을 이용한 저온열탈착 공정을 도입하여 실험하였으며 이와 더불어 토양의 TGA 실험 등을 통해 오염토양의 기본적인 특성을 살펴보았다. 대상 시료는 오염현장에서 채취하였고 sand 와 silt의 두 가지 토양을 가지고 실험하였다. TGA 실험결과 대부분의 유류가 200~30$0^{\circ}C$에서 제거됨을 알 수 있고 40$0^{\circ}C$ 이상에서는 토양내의 유기물질이 탈착됨을 알 수 있었다. 로터리 킬른을 이용한 열탈착 실험에서는 적용온도 30$0^{\circ}C$, 체류시간 7.4분에서 sand 97.4%, silt 94.2%의 제거효율을 40$0^{\circ}C$ 이상에서는 99%이상 탈착되었다.

  • PDF

Remediation of Petroleum-Contaminated Soil by a Directly-Heated Thermal Desorption Process (직접 가열식 열탈착 공정을 이용한 유류오염토양의 정화)

  • Min, Hyeong-Sik;Yang, In-Ho;Jeon, Sang-Jo;Kim, Han-S.
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.5
    • /
    • pp.62-70
    • /
    • 2009
  • A field soil highly contaminated with petroleum hydrocarbons (JP-8 and diesel fuels) was employed for its remediation by a lab-scale thermal desorption process. The soil was collected in the vicinity of an underground storage tank in a closed military base and its contamination level was as high as 4,476 ppm as total petroleum hydrocarbon (TPH). A lab scale directly-heated low temperature thermal desorption (LTTD) system of 10-L capacity was developed and operated for the thermal treatment of TPH contaminated soils in this study. The desired operation temperature was found to be approximately $200-300^{\circ}C$ from the thermal gravimetric analysis of the contaminated field soils. The removal efficiencies higher than 90% were achieved by the LTTD treatment at $200^{\circ}C$ for 10 min as well as at $300^{\circ}C$ for 5 min. As the water content in the soils increased and therefore they were likely to be present as lumps, the removal efficiency noticeably decreased, indicating that a pre-treatment such as field drying should be required. The analysis of physical and chemical properties of soils before and after the LTTD treatment demonstrated that no significant changes occurred during the thermal treatment, supporting no needs for additional post-treatments for the soils treated by LTTD. The results presented in this study are expected to provide useful information for the field application and verification of LTTD for the highly contaminated geo-environment.

A Study on Treatment Conditions of Oil Contaminated Soil by Low Temperature Thermal Desorption (저온 열 탈착에 의한 유류 오염토의 처리 조건의 연구)

  • Ha, Sang-An;Yeom, Hae-Kyong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.8
    • /
    • pp.956-960
    • /
    • 2007
  • The objective of this study is to remove BTEX(Benzene, Toluene, Ethylene, Xylene) and TPH(Total Petroleum Hydrocarbon) effectively by using method low thermal desorption. The thermal desorption is frequently selected because it can treat various contaminants effectively. The temperature and heating time are determined by TGA(Thermogravimetric analysis) curve. The experiment result from this research, removal rate of BTEX was up to 100% within 5 minutes and removal rates of TPH were more than 65% at $300^{\circ}C$ and 70% at $500^{\circ}C$ respectively. It was observed that there was a little change of removal rates of TPH.

Analysis of Ignitable Liquid Residues from Fire Debris Samples with GC/MS (GC/MS를 이용한 화재증거물속의 인화성물질 분석에 관한 연구)

  • Lee, Sung-Ryong;Han, Dong-Hun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.148-151
    • /
    • 2010
  • 화재증거물 속의 인화성물질을 분석하는 기술은 현재 다양한 추출 및 농축법을 활용한다. 본 연구에서는 Tenax TA를 이용하여 화재증거물 속의 인화성물질을 농축한 후 자동열탈착 장비를 사용하여 Tenax TA관 속에 농축되어 있는 인화성물질을 자동열탈착시켜 GC로 보낸 후 MS 분석하는 기술을 소개한다. 이러한 전처리과정을 사용하여, 화재증거물속의 인화성물질(경유, 등유 등)을 분석하였는데, 물로 화재증거물을 물을 이용하여 소화하여도, 시간이 오래지난 화재증거물이라도 열탈착 장비를 이용한 분석은 경유, 등유등을 확인하는데 유용하였다.

  • PDF

마이크로파 에너지를 이용한 톨루엔 흡착-냉각 응축에 관한 연구

  • Do, Sang-Hyeon;Kim, Seong-Uk;Kim, Yun-Gap;Choe, Seong-U
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2006.11a
    • /
    • pp.124-126
    • /
    • 2006
  • 마이크로파 에너지의 열원을 이용하여 흡착된 톨루엔을 탈착함으로써 활성탄의 재생에 관한 실험을 실시하였다. 마이크로파를 조사함에 따라 흡착제의 온도가 급격히 상승하여 톨루엔이 탈착할수 있는 온도까지 빠른 시간에 도달하였으며, 이 열에 의하여 톨루엔이 탈착함을 알수 있었다.

  • PDF

A study of analytical method for volatile fatty acids (VFA) by cryogenic trapping-thermal desorption (CT-TD) technique (저온농축열탈착 시스템을 연계한 유기지방산의 분석법 평가 및 검토)

  • Ahn, Ji-Won;Kim, Ki-Hyun;Im, Moon-Soon;Ju, Do-Weon
    • Analytical Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.200-211
    • /
    • 2011
  • In this study, 13 compounds including four volatile fatty acids (VFA) and nine volatile organic compounds (VOC) were analyzed by cryogenic trapping-thermal desorption technique. In order to evaluate the analytical method for VFA, calibration experiments were performed using five different sorbent materials. When the calibration results are compared between different sorbents, sampling tube filled with Carbopack X showed the highest response factor (RF) for both VFA and VOC. To validate this new analytical method for VFA using cryogenic trapping-thermal desorption technique, this method was compared with alkali absorption method recommended by the odor prevention law of the Korea Ministry of Environment (KMOE). For this purpose, unknown samples were analyzed by two different methods, i.e., cryogenic trapping-thermal desorption (TD) and alkali absorption with solid phase microextraction (SPME). When the results of two different methods were compared, ratios of concentrations determined by the two analytical methods (TD/SPME) was found as 0.46 (valeric acid) ~ 0.71 (isovaleric acid). Therefore, additional study is required to properly establish and find stable analytical conditions for VFA analysis. Furthermore, comparison between two different methods should be made with more reliable calibration approaches.

Determination of Volatile Organic Compounds emitted from Municipal Solid Waste Landfill Site by Thermal Desorption-Cryofocusing-GC/FID/FPD (열탈착-저온농축-GC/FID/FPD에 의한 도시 생활폐기물 매립장에서 방출되는 휘발성 유기화합물의 측정에 관한 연구)

  • Kim, Man-Goo;Jung, Young-Rim;Seo, Young-Min;Nam, Sung-Hyun;Kwon, Young-Jin
    • Analytical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.274-285
    • /
    • 2001
  • In this study, the thermal desorption-cryofocusing-gas chromatographic(TD-C-GC) method was developed for determination of volatile organic compounds(VOCs) in ambient air and was applied at the municipal solid waste landfill sites. On-column cryofocusing was possible only with a 100 ml dewars bottle in TD-C-GC method with a stainless steel column. However, high operating pressure was needed for purging VOCs from the absorbent trap, which was able to solve by pressure programming with a electric pressure controller. By using both pressure and temperature programming brought increasing of resolution power in on-column cryofocusing method, but the high pressure caused a leakage of sample tube with repeated use. A loop cryofocusing devise was also developed and compared with the direct on-column method. In loop cryofocusing method, VOCs were concentrated on a 0.8mm i.d. loop which is located between the injector and separation column by using liquid nitrogen. In order to purge VOCs from the absorbent trap, only 0.4 psi of pressure was need in the loop cryofocusing method. Dual detection system was applied for the analysis of VOCs; a FID was used for hydrocarbons and a FPD was used for sulfur-containing compounds. Qualitative analysis was done by on-column cryofocusing GC-MS system. Among the large number of VOCs, toluene was the most abundant. Hydrogen sulfide, dimethyl sulfide, carbon disulfide, dimethyl disulfide and methyl propyl disulfide were detected at landfill site by FPD.

  • PDF

Carbon dioxide adsorption - desorption characteristics of zeolite for the removal of indoor carbon dioxide (실내공간 이산화탄소 저감용 제올라이트의 이산화탄소 흡착 및 탈착성능 분석)

  • Lee, Ji-Yun;Cho, Young-Min;Kwon, Soon-Bark;Park, Duck-Shin;Lee, Ju-Yeol
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05b
    • /
    • pp.1115-1118
    • /
    • 2010
  • 최근 실내공기질에 대한 관심이 높아지면서 실내공기질을 쾌적하게 유지하기 위한 다양한 기술에 대한 연구가 활발히 이루어지고 있다. 기존에는 미세먼지와 부유미생물 등이 가장 중요한 오염물질이었으나, 최근에는 이산화탄소가 크게 각광받고 있다. 이산화탄소는 그 자체가 환기의 지표이기도 하지만, 최근의 저탄소 녹색성장 기조에 따라 환기에 의한 냉난방 에너지 비용을 절감하는 방안에 대한 관심도 크게 높아지고 있다. 본 연구에서는 제올라이트를 이용하여 실내공간의 이산화탄소를 제어하는 방안에 대하여 기술하였다. 소형 lab-scale의 이산화탄소 흡착성능 평가시스템을 제작하고, 이를 이용하여 제올라이트의 이산화탄소의 흡착성능을 알아보았다. 또한, 본 시스템의 실용화를 위해서는 이산화탄소가 흡착한 제올라이트의 재생이 필요한데, 이를 위하여 다양한 온도와 압력 등의 조건 하에서 이산화탄소의 탈착성능을 TSA/PSA를 이용하여 알아보았다. 흡착실험을 통하여 제올라이트를 이용한 실내공간용 이산화탄소의 저감 효과를 확인할 수 있었다. 그러나, 탈착실험 결과 2~5회 정도 열탈착 시킨 후에는 이산화탄소의 흡착 성능이 현저하게 감소하여, 이를 개선하기 위한 방안의 개발이 필요함을 알 수 있었다.

  • PDF

Thermal Effusion of Implanted Inert Gas Ions from Si(100) (Si(100)에 주입된 불활성 기체 이온들의 방출 특성)

  • Jo Sam K.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.1
    • /
    • pp.73-80
    • /
    • 2006
  • Thermally-driven effusion of inert gases out from Si(100), into which energetic $\~l keV\;He^+,\;Ne^+,\;A^r+,\;and\;Kr^+ ions$ had been implanted at a moderate substrate temperatures of $\~400 K$, was investigated by means of temperature-programmed desorption (TPD) mass spectrometry. While He effused out broadly over $500\~1,100 K$, Ne, Ar, and Kr effusion occurred sharply at 810, 860, and 875 K, respectively. Hydrogen adsorption/desorption analysis for the ion-treated Si(100) surfaces indicated minimal to severe damage by ions with increasing mass from He to Kr. Implications of these results in light of literature reports are discussed.