• Title/Summary/Keyword: 열전달손실

Search Result 198, Processing Time 0.032 seconds

Finite Element Analysis of Temperature Distribution for Power Transformer (유한요소법을 이용한 전력용변압기의 온도분포해석)

  • Ahn, Hyun-Mo;Hahn, Sung-Chin
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.818_819
    • /
    • 2009
  • 본 논문에서는 온도상승의 열원이 되는 권선과 철심의 전력손실을 유한요소법을 이용한 전자계해석과 스타인메츠실험식으로 산정하였다. 온도에 대한 자연대류 열전달계수를 산정하여 경계면에서의 경계조건으로 적용하였다. 열전달 해석을 위해 전력용변압기를 3차원 형상으로 모델링한 후 유한요소법을 이용해 권선과 철심에서의 온도분포를 해석하였다.

  • PDF

A Study on the Heat Loss Effect of Steel Structure in a Refrigerator Mullion (냉장고 멀리언부 구조보강용 철구조물의 열손실 영향 연구)

  • Ha, Ji Soo
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.35-41
    • /
    • 2014
  • The present study has been carried out to reduce the heat loss from a refrigerator by numerical heat transfer analysis and temperature measurement experiment for the verification of heat transfer analysis result. To perform this purpose, two dimensional heat transfer analysis and measurement of temperature on the surface of freezer for the horizontal cross sectional plane of a refrigerator has been accomplished. From the present study, it could be seen that the steel support in the mullion near gasket region has a heat transfer characteristics which transfer outside heat well from the high temperature hotline and outside air to the inner refrigerator. The effect of removing steel support on the reducing heat loss of a refrigerator was 24.8% and removing steel support might introduce significant improvement of refrigerator heat loss.

Development of Simulation for Vuilleumier Cycle Heat Pump (VM 사이클 히트펌프 설계프로그램의 개발)

  • 박병덕;이기우
    • Journal of Energy Engineering
    • /
    • v.10 no.2
    • /
    • pp.105-113
    • /
    • 2001
  • 지구환경문제와 에너지문제를 해소하는 한 방법으로서 Vuilleumier 사이클 기관(VM)을 이용한 공조기형 열구동형 히트펌프시스템(VMHP)이 각광을 받고 있다. VMHP의 제작에 있어서는 VM의 각 부분의 이론적 검토 및 최적설계를 위한 해석프로그램의 개발이 필수적이고 최적설계를 위한 설계 기본서의 도출 및 설계자료의 확보가 필요하다. VMHP의 상세한 성능해석이나 설계에 활용 가능한 성능해석프로그램을 개발하였다. 해석은 VM의 시스템의 각 부분을 11개 부분으로 나누어 단열모델해석으로 수행하였다. 열교환기에서의 열전달 성능과 재생기손실, 열전도손실, 셔틀손실, 유동에 의한 압력손실과 열압축측과 열펌프측 사이의 마찰손실, 피스턴실 및 로드실의 마찰손실을 고려한 해석을 수행하였다. 해석에 의한 계산치의 정확성을 본 해석결과를 이용하여 제작한 시험기에 의해 비교하였다. 계산치와 시험기에 의한 전체성능을 비교하였고 또한 각각의 손실에서 고유한 파라미터를 추출하여 그 파라미터의 변화에 따른 열손실 전체의 변화 정도를 파악하여 실험치와 계산치의 정상적인 비교로부터 성능해석의 정도를 비교하였다. 비교결과에 의해 난방능력은 8%, 냉방능력은 19%의 최대오차로서 본 해석결과가 VMHP의 설계를 위해 유용한 수단으로 사용될 수 있음을 확인하였다.

  • PDF

A Study on the Radiation Heat Transfer Effect near a Refrigerator Gasket (냉장고 가스켓 주위의 복사열전달 효과에 관한 연구)

  • Ha, Ji-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.1605-1610
    • /
    • 2015
  • The present study has been accomplished to elucidate the effect of radiation heat transfer in the heat transfer analysis of refrigerator gasket, which has near 30% of refrigerator heat loss. The numerical heat transfer analysis has been conducted with the simplified modeling of refrigerator gasket. From the present CFD analysis, heat loss at the gasket is $25.6W/m^2$ for the case without radiation effect and that for the case with radiation effect is $55.0W/m^2$, which is 2.2 times greater heat loss. The radiation protection layers were installed in the gasket from 0 to 7 and the case with 7 layers has 33% reduction effect of heat loss compared with the case without any radiation protection layer. Additionally, it is better effect of radiation heat loss reduction that the radiation protection layers would be placed to the outer or inner side of gasket rather than placing to the center of gasket.

An Experimental Study on Tube-Side Heat Transfer Coefficients and Friction Factors of the Enhanced Tubes Used in Regenerators of Absorption Chillers (흡수식 냉동기의 재생기에 사용되는 전열촉진관의 관 내측 열전달계수 및 마찰계수에 대한 실험적 연구)

  • Kim, Nea-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.716-723
    • /
    • 2016
  • Enhanced tubes are used widely in the heat exchangers of absorption chillers. In regenerators, corrugated, ribbed or floral tubes are commonly used. In this study, the tube-side heat transfer coefficients and friction factors of enhanced tubes were obtained experimentally using the Wilson Plot method. The results showed that the heat transfer coefficients and the friction factors were the largest for the corrugated tube, followed by the ribbed tube. The heat transfer coefficients and friction factors of the floral tube matched those of the smooth tube within 4%, which suggests that the heat transfer and friction characteristics of the floral tube may be accounted for properly by the hydraulic diameter. The B(e+) and g(e+) were obtained from the experimental data of the corrugated and ribbed tube. The B(e+) and g(e+) of the corrugated tube matched those of the existing correlation within 20%. The present results may be used for an assessment of the heat transfer and friction characteristics of the enhanced tubes for regenerators.

A Study on the Performance Analysis of the PAO-AIR Heat Exchangers in an Aircraft (항공기용 PAO-공기 열교환기 성능분석 연구)

  • Park, Dong-Myung;Joung, Yong-In;Moon, Woo-Yong;Park, Sung-Sun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.11
    • /
    • pp.934-939
    • /
    • 2012
  • In this study, the performance validation of a PAO-AIR heat exchanger developed for the ECS(Environmental Control System) of a UAV(Unmanned Aerial Vehicle) has been carried out. The performance goals of a PAO-AIR heat exchanger were established by the system schematic analysis. And a heat exchanger to be met the ECS performance was developed by a detailed design and a precision manufacture. Using the developed heat exchanger, the experiment about pressure loss and effectiveness, overall heat transfer coefficient to prove the developed PAO-AIR heat exchanger performance in various conditions as well as a design point of heat exchanger was performed and the experimental results were analyzed. As the experimental results, the performance and characteristic of a PAO-AIR heat exchanger developed for the ECS of a UAV were analyzed and the development suitability was proved.

Numerical Study on Flow and Heat Transfer Characteristics of Pipes with Various Shapes (파이프 형상에 따른 내부 열유동 특성과 성능에 관한 수치해석적 연구)

  • Park, Sang Hyeop;Kim, Sang Keun;Ha, Man Yeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.11
    • /
    • pp.999-1007
    • /
    • 2013
  • The present work reports numerical results of the pressure drop and heat transfer characteristics of pipes with various shapes such as circular, elliptical, circumferential wavy and twisted using a three-dimensional simulation. Numerical simulations are calculated for laminar to turbulent flows. The fully developed flow in pipes was modeled using steady incompressible Reynolds-averaged Navier-Stokes (RANS) equations. The friction and Colburn factor of each pipe are compared with those of a circular tube. The overall flow and heat transfer calculations are evaluated by the volume and area goodness factor. Finally, the objective of the investigation is to find a pipe shape that decreases the pressure loss and increases the heat transfer coefficient.

Pressure Loss and Heat Transfer Characteristics of the Glass Beads-Water Flow in a Vertical Tube (수직관내 유리알-물 유동의 압력손실 및 열전달 성능)

  • Kim, N.H.;Kim, J.S.;Lee, Y.P.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.4
    • /
    • pp.550-560
    • /
    • 1996
  • Recently, fluidized bed heat exchangers with circulating liquid are widely used in a number of places-chemical, process, food concentration, waste water treatment facilities, etc. In a circulating heat exchanger, solid particles circulate with the liquid, thereby increase the heat transfer and reduce the fouling potential of the heat exchanger. In this study, glass beads were circulated through a vertical tube. The pressure loss and the heat transfer coefficient were measured. At low flow velocities, glass beads enhanced the heat transfer considerably. The enhancement increased as the volume fraction of the glass beads increased. The pressure loss showed a similar trend. From the observed particle behavior near tube wall, a possible explanation of the trend is provided.

  • PDF

An Experimental Study on the Pressure Drop and Heat Transfer Performance in Tubes with Three Dimensional Roughness (삼차원 조도관의 압력손실 및 열전달 성능에 대한 실험적 연구)

  • Kim, N.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.2
    • /
    • pp.276-286
    • /
    • 1995
  • In this study, pressure drop and heat transfer coefficients were measured in tubes with three dimensional roughness. Dimples were made by rotating the saw-tooth shaped finning disc on the outer tube surface. Resultant dimple shape was oval. Friction and heat transfer tests were performed with a range of roughness variables-roughness height 'e', axial roughness pitch 'p', circumferential roughness pitch 'z'. Within the test range, tube with e=0.5mm, z=5mm, p=3mm performed best. The efficiency ratio(rati of the heat transfer improvement and the pressure drop increase) of the tube approached 1.0 at low Reynolds number, and it was higher than that of the two-dimensional roughess tube of the same roughness height. Test data were predicted by 'discrete element method'. Results show that discrete element method underpredicts the friction data by 2% to 32%, and overpredicts the heat transfer data by-12% to 113%.

  • PDF

Pressure Loss and Heat Transfer Characteristics of Heat Exchanger Using Static Mixing Technology (정적혼합기술 응용 열교환기의 압력손실 및 열전달 특성)

  • Park Sang-Kyoo;Yang Hei-Cheon;Jeon Jun-Chul
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.1
    • /
    • pp.65-72
    • /
    • 2006
  • Heat transfer augmentation in heat exchangers has received much attention in recent years, mainly due to energy efficiency and environmental considerations. Many active and Passive techniques are currently being employed in heat exchangers, with some inserts providing a cost-effective and efficient means of augmenting heat transfer. The Purpose of this paper is to determine the pressure loss and heat transfer characteristics of a heat exchanger using static mixing technology. Experimental measurements were taken on two set-ups: a single tube heat exchanger and a shell-tube heat exchanger with two static mixing inserts. It was concluded that the static mixing inserts resulted in an increase in the pressure loss and heat transfer characteristics as can be expected.