Pressure Loss and Heat Transfer Characteristics of the Glass Beads-Water Flow in a Vertical Tube

수직관내 유리알-물 유동의 압력손실 및 열전달 성능

  • 김내현 (인천대학교 기계공학과) ;
  • 김정식 (인천대학교 대학원) ;
  • 이윤표 (한국과학기술원 열유체연구실)
  • Published : 1996.11.01

Abstract

Recently, fluidized bed heat exchangers with circulating liquid are widely used in a number of places-chemical, process, food concentration, waste water treatment facilities, etc. In a circulating heat exchanger, solid particles circulate with the liquid, thereby increase the heat transfer and reduce the fouling potential of the heat exchanger. In this study, glass beads were circulated through a vertical tube. The pressure loss and the heat transfer coefficient were measured. At low flow velocities, glass beads enhanced the heat transfer considerably. The enhancement increased as the volume fraction of the glass beads increased. The pressure loss showed a similar trend. From the observed particle behavior near tube wall, a possible explanation of the trend is provided.

Keywords

Acknowledgement

Supported by : 한국과학재단