• Title/Summary/Keyword: 열에너지 평형

Search Result 10, Processing Time 0.01 seconds

Role of Atmospheric Turbulences and Energy Balances in the Atmospheric Surface Layer (접지층에서 대기난류의 역할과 에너지 평형)

  • Kwon, Byung-Hyuk;Kim, Geun-Hoi;Kim, Kwang-Ho;Kang, Dong-Hwan
    • Journal of Wetlands Research
    • /
    • v.11 no.1
    • /
    • pp.105-113
    • /
    • 2009
  • Heat energy exchange is very important processes in the coastal wetland ecosystems. We observed and analyzed the net radiation flux, the sensible heat flux, the latent heat flux and the soil heat flux, which are balanced in the heat energy balance, over a reclaimed land covered with reeds at Goheung, Jeonllanamdo where is horizontally plane. The atmospheric turbulence had been measured in order to estimate the heat transfer during 5 intensive observation periods (IOPs). It was considered that the soil consists of water, fine particles, and vegetation canopy that changes color and density according to the season. We examined the characteristics of the heat flux and the vegetation effect on the air temperature control. It was noted that the heat was transported mainly by latent heat flux in the summer season and the vegetation canopy decreased the daily temperature range due to the heat storage. The air temperature was lower at the IOPs site than near urban area. This showed that the coastal wetland covered with the vegetation control the thermal environment.

  • PDF

One-dimensional Numerical Analysis of the Effect of Seawater Feed Rate on Multi-effect Solar Stills (태양열 담수기 다중효용부의 해수 공급유량에 관한 1차원 수치해석)

  • Lim, Byung-Ju;Yu, Sang-Seok;Park, Change-Dae;Chung, Kyung-Yul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.7
    • /
    • pp.477-484
    • /
    • 2016
  • In a multi-effect solar distiller, a feeding rate of seawater to each effect should be decreased as the effect number is increased. In previous studies, the feed rate of seawater was not reduced evenly between the effects, which is unreasonable, since the thermal energy input of each effect decreases by the same amount. In this work, numerical analysis was carried out in order to elucidate this discrepancy. The results showed that the amount of distillates produced was almost the same for both evenly and unevenly reduced flow rates between the effects. Optimum feed rates of seawater with various energy inputs from exhaust gas heat exchanger were also obtained. The results showed that the optimum feed rate of the first effect increased linearly or reached a steady state depending on the heat flux.

Numerical approach for comparative performance study of tube type and box type hybrid photovoltaic/thermal system (시뮬레이션을 통한 박스형과 튜브형 태양광열 복합 시스템의 성능 분석)

  • Bhattarai, Sujala;Kim, Dae-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.9-18
    • /
    • 2011
  • 태양광열 복합 시스템(photovoltaic/thermal hybrid solar system, PV/T)은 태양광 모듈 및 태양열 집열판의 단일화를 통한 전기 및 열에너지의 동시 생산이 가능하도록 구성되고 기존 태양광 모듈의 온도 상승에 따른 효율 저하의 문제점을 보완 및 발생하는 열을 회수하여 온수 생산이 가능한 장치이다. 본 연구에서는 액체형 PV/T 시스템의 대표적인 두 형태인 박스형과 튜브형의 성능 검증을 위하여 수학적 모델링을 통한 두 시스템의 열 및 전기적 성능을 비교 분석하였다. 모델링은 에너지 평형식을 이용하여 시간에 따른 각 부분의 온도의 변화를 예측할 수 있도록 수립되었으며 계산된 결과를 기준으로 전기, 열, 및 전체효율을 도출해 내고, 이를 바탕으로 두 시스템의 성능을 분석하였다. 시뮬레이션 결과를 바탕으로, 박스형 PV/T 시스템의 최고 온수 온도는 $52^{\circ}C$로 예측되었고, 반면에 튜브형은 $48^{\circ}C$에 머물렀다. 또한 열효율은 박스형이 최대 51%, 튜브형이 41%, 전기효율은 박스형이 약 14%, 그리고 튜브형이 13%로 나타났으며, 전체효율은 박스형이 73%, 그리고 튜브형이 64%로 나타나 박스형 PV/T 시스템이 튜브형보다 더 나은 성능을 가지는 것으로 예측되었다. 이는 박스형이 튜브형보다 태양광 모듈과 온수와의 접촉면적이 넓어 더 많은 열전달이 발생하기 때문으로 사료된다.

Uncertainty Assessment of CANDU Void Reactivity using MCNP-4C with ENDF/B-VII(I) (ENDF/B-VII기반 MCNP-4C를 이용한 CANDU-6 기포반응도 불확실성 평가(I))

  • Hong, S.T.;Kwon, T.A.;Lee, Y.J.;Oh, S.K.;Lee, S.K.;Kim, M.W.
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2008.04a
    • /
    • pp.69-75
    • /
    • 2008
  • 기포반응도는 월성발전소를 비롯한 CANDU형 원자로의 주된 안전성 쟁점사안으로 끊임없이 논의되어 왔다. 이는 설계기준사고가 노심에서 열에너지 불균형이 원인이 되어 기준이상의 핵연료 파손과 방사성물질 누출로 발전할 위험이 있는 사건들로 정의될 때, 사건 진행 과정에 기포반응도 증가는 조기에 운전중단을 실패할 경우 출력폭주로 이어지므로 사건의 결말이 중대사고로 전환될 위험이 크기 때문이다. 본 연구는 공개된 최신 핵자료인 ENDF/B-VII.0를 NJOY.99로 처리한 연속에너지 반응단면적 라이브러리를 구축하고 MCNP-4C에 접속하여 37봉 천연우라늄 핵연료다발의 표준노심격자에 대한 기포반응도를 시뮬레이션하여, 지금까지 각종문헌에 제시된 값들과 비교, 종합하므로 내제된 불확실성을 추정하는 내용이다. ENDF/B-VII.0 기반 MCNP-4C의 CANDU 노심격자 모델은 동일한 핵자료와 핵종농도를 사용한 WIMS-IAEA 모델과 비교할 때, 초기 노심의 임계도 오차 약 3.51mk가 연소 진행에 따라 $7.5\times10^{-4}mk$/MWD/teU의 비율로 감소하는 것으로 나타났다. 또한 MCNP-4C 예측기포반응도는 초기노심에서 기포율 50% 및 100%에 대해 각각 8.38 및 15.96mk, 평형노심에서 7.68 및 14.72mk로 계산된다. 이는 월성 2, 3, 4 FSAR의 초기노심 및 평형노심에서 100% 기포상태에 대한 값, 약15.0 및 10.6mk와 비교할 때, 초기노심은 약 1.0mk 평형노심은 약4, 1mk 보수적이지만, 다른 연구결과들과는 최대오차 ${\pm}1{\sim}2mk$ 이내에서 잘 일치하는 것으로 평가되었다. 본 연구는 CANDU 노심의 기포반응도 불확실성 요인의 규명 및 영향평가를 위한 노력의 일부로서 앞으로 감속재의 붕산농도 변화, 감속재 및 냉각재의 중수 순도 변화, 기기노화에 의한 격자 구조 및 물성 변화, 중성자속 및 출력 분포 불균형, 반응도조절장치의 위치, 등 주요 설계변수의 변화에 대한 반응도영향 분석연구를 계속할 계획이다.

  • PDF

ZnS thermal CVD's solution of phenomenon of roughing exhaust line blockage for increasing continous process time

  • Jo, Yong-Beom;Kim, Jin-Cheol;Choe, U-Seong;Jeong, Won-Ho;U, Si-Gwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.117-117
    • /
    • 2016
  • 일반적인 박막 성장용 CVD는 막 성장 시간이 짧게는 수분에서 수시간 정도 소요하기 때문에 장비에 문제가 발생 할 시 조치를 취하고 다음 현상을 개선하기에 용이 하였다. 그리고 대분분의 장비가 국산화되어 있을 만큼 많은 경험치가 축척되어 있다. 그러나 2, 4 족 화합물 성장용 CVD는 고아학 렌즈 생산용 장비로 국내에서는 아직 생소하고 공정 경험이 없는 새로운 장비이다. 2,4 족 화합물의 특징은 다음과 같다. 2,4 족 화합물은 M, N 이라는 두가 물질이 결합하여 형성한다. 2,4 족 화합물은 높은 융점과 낮은 증기압을 갖니다. 이런 물질들은 고온에서 아래와 같이 평형적으로 반응한다. $$nMN_{(s)}=nM_{(g)}+Nn_{(g)}$$ 화합물인 $MN_{(g)}$의 상태로 존재할 수 있으나 일바적으로 n=2인 4족 원소의 2원자 분자로된 기체가 지배적이다. 증기상을 이용한 성장 공정에서는 구성 원자나 분자를 만들어내는 단계, 이들을 공급원에서 기판까지 수송하는 단계, 기판 위에 흡착하는 단계, 핵의 생성과 단결정을 생성하는 단계, 필요치 않는 구성물을 제거하는 단계를 거쳐 공정이 진행 된다. 각 공정은 성장 물질에 충분한 자유도를 주어야하고 자유도를 주기 위해서는 많은 열에너지가 공급 되어야 한다. 따라서 기존의 박막 성장 공정 보다 성장 속도가 느리고 증착하는 양보다는 버리는 양이 많으며 버려지는 성장물질들은 급격한 온도 변화가 생기는 곳에서 급격히 증착하기 시작한다. 본 성장 공정이 진행되는 압력은 30 torr 부근이며 공정 온도는 $1000^{\circ}C$ 부근이다. 30 torr 영역에서는 열전달이 대기압과 같은 속도로 진행되기 때문에 지속적으로 온도에의해 손상을 받는 부위가 있을 수 있다. 높은 공정 온도와 높은 공정 압력은 내부 구조물로 발생된 열을 빠르게 장비 표면으로 수송하게 되고 그 결과 장비의 연결 부분에 장착된 오링에 손상을 주게 된다. 오링 손상을 방지 하기위해 냉각수 라인을 형성하여 오링을 보호하게 되면 열역학적 기울기가 급격히 발생하는 부분이므로 CVD의 반응 부산물들이 빠른 시간동안 증착하게 되고 막히는 현상이 발생하게 된다. 목표한 두게까지 박막을 성장시키기 위해서는 장시간 공정이 필수이며 장시간 공정을 안정적으로 가져가지 위해서는 배기 라인의 막힘 현상을 해결하여야 한다. 본 논문에서는 막힘 현상의 진행을 시간에 따라 해석하였으며 장시간 공정을 진행하기위해 필요한 요소와 기구적으로 조치가 가능한 방법에 대해 작성하였다.

  • PDF

Heat balance analysis for process heat and hydrogen generation in VHTR (공정열 및 수소생산을 위한 초고온가스로 열평형 분석)

  • Park, Soyoung;Heo, Gyunyoung;Yoo, YeonJae;Lee, SangIL
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.85-92
    • /
    • 2016
  • Since the power density of the VHTR(Very High Temperature Reactor) is lower, there is less possibility of core melt. VHTR has no risk of explosion caused by hydrogen generation when the loss of coolant accident occurs, which is another advantage. Along with safety benefit, it can be used as a process heat supplier near demand facilities because coolant temperature is very high enough to be used for industrial purpose. In this paper, we designed the primary system using VHTR and the secondary system providing electricity and process heat. Based on that 350 MW thermal reactor proposed by NGNP(Next Generation Nuclear Part), we developed conceptual model that the IHX(Intermediate Heat Exchanger) loop transports 300 MW thermal energy to the secondary system. In addition, we analyzed thermodynamic behavior and performed the efficiency analysis and optimization study depending on major parameters.

Design, Analysis and Experiment of Potato Gun with a Spherical Projectile (구형 탄환을 이용한 감자총의 설계, 해석 및 시험)

  • Kang, Hong-Jae;Kim, Ji-Hwan;Kim, Young-Sik;Son, So-Eun;Choi, Han-Ul;Choi, Jeong-Yeol
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.10
    • /
    • pp.796-804
    • /
    • 2013
  • The "Potato Gun," a simple heat engine, is fabricated, tested and analyzed as a part of engineering education program of combustion and propulsion classes. Combustor pressure is predicted by the chemical equilibrium analysis of a constant volume combustor. Then, the internal ballistics, the conversion of thermal energy into the mechanical energy of a projectile, is predicted though the expansion process. The trajectory of a projectile is estimated by considering the aerodynamic effect around the spherical projectile. The energy conversion efficiency and the equivalence ratio of the fuel-air mixture could be estimated by the comparison of the experimental results and the theoretical prediction. The present work would be an example of attracting the interest of students for the application of the engineering principles at undergraduate level by recycling the waste materials.

Biodiesel Production from Waste Oils Mixed with Animal Tallows and Vegetable Oil by Transesterification Using Ultrasonic Irradiation (초음파를 이용한 동식물성 혼합 폐유지로부터 바이오디젤 제조)

  • Chung, Kyong-Hwan;Park, Byung-Geon
    • Korean Chemical Engineering Research
    • /
    • v.51 no.4
    • /
    • pp.487-492
    • /
    • 2013
  • Transesterifications of waste oils mixed with animal tallows and vegetable oil by ultrasonic energy were examined over various catalysts for biodiesel production. Reaction activities of the transesterification were evaluated to the ultrasonic energy and thermal energy. The physicochemical properties of feedstock and products were also investigated to the biodiesels produced from the oils in the reaction using ultrasonic energy. The highest fatty acid methyl ester (FAME) yield was obtained on the potassium hydroxide catalyst in the transesterification by ultrasonic irradiation. The effective reaction conditions by ultrasonic energy were 0.5 wt% catalyst loading and 6:1 molar ratio of methanol to the mixed oils. The reaction rate of the transesterification by ultrasonic energy was faster than that by thermal energy. The highest yields of FAME were obtained as 80% in 5 min and the reaction equilibrium reached at that time.

Flux Profile Method for Evaluating the thermal Efficiency of Green roof (Flux Profile Method를 적용한 옥상녹화의 열효율 성능 평가)

  • Kwon, You Jeong;Seo, YongWon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.320-320
    • /
    • 2022
  • 기후변화와 도시화로 인한 영향으로 도시의 폭우, 폭염을 비롯한 현상이 빈번하게 발생하고 있다. 특히 시가화 지역의 높은 불투수율은 도시홍수를 야기한다. 이러한 현상을 완화하기 위해 도시지역에서는 그린인프라와 저영향개발이 도입되고 있다. 그 중 지속가능한 발전을 위한 필수요소로 자리매김한 옥상녹화는 도시에 위치한 건물의 상층부와 내부의 온도를 낮춤으로써 에너지절감효과와 강우 시 빗물을 저류함으로써 우수유출 저감효과, 그리고 도시 공간 내 녹지도입으로 인한 이산화탄소 배출 저감 효과 등을 기대할 수 있다. 본 연구에서는 열섬현상완화와 유출 저감의 방안 중 하나인 옥상녹화(Green roof)의 효과를 정량적으로 평가하기 위해 콘크리트로 이루어진 동일한 제원의 실험동을 구축하고, 실험동 내외부의 온도, 습도, 강우, 풍속, 일사량 등의 기상자료를 측정할 수 있는 센서를 설치하였다. 각 실험동에서 측정된 기상요소를 Flux Profile Method를 적용하여 공간 내에 있는 열에너지의 총량인 순복사열을 구성하는 현열속, 잠열속, 토양열속(H, LE, G)을 산정하였다. 또한 에너지 평형에 따라 산정된 각 실험동의 열속과 지표면 복사량 관측자료을 정량적으로 비교하여 옥상녹화의 적용성을 평가하였다. 2021년 7월 21일부터 2021년 7월 28일 까지 모니터링한 결과 옥상녹화의 열 효율은 일반 콘크리트 지붕에 비해 실내온도가 최대 6.83℃ 낮게 나타나며 이는 여름철 건물 내부의 온도조절에 필요한 에너지 저감효과를 볼 수 있다. Flux Profile Method를 적용한 결과 옥상녹화의 전체 열속 중 현열속 28.5% 잠열속 70.7%, 토양열속 0.5% 의 복사량 분포를 보였고, 일반 콘크리트 지붕은 현열속 45.3%, 잠열속 38.6%, 토양열속 16.2% 으로 나타났다. 이와 같은 방법은 옥상녹화의 정량적 평가를 가능하게 함으로서 향후 기후변화 대응방안 및 전략 수립 시 옥상녹화의 온도저감효과 분석에 적극 활용할 수 있을 것으로 판단된다.

  • PDF

Study on Material Characteristics and Firing Temperature of Jar Coffins from Oryang-dong Kiln Site and Jeongchon Tomb, Naju, Korea (나주 오량동 유적 및 정촌 고분 출토 옹관의 재료적 특성 및 소성온도 연구)

  • Kim, Su Kyoung;Jin, Hong Ju;Jang, Sungyoon
    • Journal of Conservation Science
    • /
    • v.34 no.3
    • /
    • pp.179-193
    • /
    • 2018
  • This study is aimed to investigate the provenance of raw materials and firing temperature of jar coffins excavated from the Oryang-dong kiln site and Jeonchon tomb site, Naju, Korea. Most of jar coffin samples shows same range of magnetic susceptibility and have gray color, while 404 and 405 of Jeongchon site are reddish yellow. In some samples fired at high temperature, the water absorption at the mouth rim and body part of same jar coffin were 3.50% and 7.56% respectively. It means that heat transfer and equilibrium in the kiln was not properly continued and the heat energy transferred to the mouth rim and the body part was different. In the petrographic analysis, As a tempering materials, biotite, weathered quartz and feldspar were added in the jar coffins of Oryang-dong site, and biotite, polycrystalline quartz and feldspar in it of Jeongchon site. Tempering materials were found more in the body than in the mouth rim of same jar coffin of Oryang-dong site. It seemed that some samples were fired at over 1,000 to $1,100^{\circ}C$, which showed vitrified texture in the scanning electron images and the rest of samples were fired at below $900^{\circ}C$. Due to similarity of chemical compositions, it is estimated that jar coffins of Jeongchon tomb were produced and supplied from Oryang-dong kiln site. However, the slight difference of some trace elements distribution of samples is attributed to the selection of clay depending on the location.