• Title/Summary/Keyword: 열분석적 특성

Search Result 2,493, Processing Time 0.034 seconds

Research Trends on the Structure and System of Nickel Catalysts for Low-Temperature Processes in Highly Efficient Carbon Dioxide Methanation Reactions (고효율 이산화탄소 메탄화 반응을 위한 저온 공정용 니켈 촉매 구조 및 시스템 연구 동향)

  • Jaewon Jang;Jungpil Kim
    • Korean Chemical Engineering Research
    • /
    • v.62 no.4
    • /
    • pp.312-326
    • /
    • 2024
  • This review comprehensively reviews the latest research trends in nickel catalysts for low-temperature CO2 methanation reactions, with special emphasis on catalyst synthesis and reactor design for low-temperature CO2 methanation reactions. In addition to the previously reported catalyst synthesis method of impregnation, the effects of structural and chemical properties of catalysts synthesized by solvothermal synthesis and electrospinning on CO2 methanation reactions were analyzed. We also discuss the potential for process cost reduction and scale-up based on 3D catalyst structures and catalyst stacked reactor designs to improve reaction efficiency. It is found that the efficiency of the CO2 methanation reaction can be maximized by controlling the oxygen vacancies and crystal structure of the catalyst through an innovative catalyst synthesis method, and by increasing the active area of nickel through the 3D structure of the catalyst and the reactor design. It is expected that this review will serve as the basis for the field of converting natural gas into CH4, which can be used as a substitute for natural gas while reducing CO2, a major greenhouse gas.

Application of WEP Model to the Cheonggecheon Watershed (청계천 유역에 대한 WEP 모형의 적용)

  • Noh, Seong Jin;Kim, Hyeon Jun;Cheong, Il Moon;Jang, Cheol Hee;Kim, Dong Pil
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.148-152
    • /
    • 2004
  • 본 연구에서는 물순환의 재생이나 보전에 필수적인 유역 물순환의 정량화와 유역변화의 영향예측을 위해 개발된 WEP (Water and Energy Transfer Process) 모형의 국내 유역에 내한 적용성을 검토하고, 청계천 유역의 물순환 양상을 모의하였다. WEP 모형은 복잡한 토지이용이 이루어지고 있는 도시하천 유역에 내한 물순환의 정량화를 목적으로 일본의 토목연구소 (PWRI; Public Works Research Institute), 과학기술진흥사업단, Jia 박사 등에 의해 공동으로 개발되었으며 지표면 및 비포화 토양층의 물${\cdot}$열 플럭스 계산, 하도흐름의 추적계산 및 지하수 유동계산, 격자내 토지이용의 불균질성 반영 등이 가능한 물리적인 기반의 공간 분포형 모형 (Physically Based Spatially Distributed)이다. 모형을 적용한 청계천 유역 (유로연장 13.75 km, 유역 면적 $50.96km^2$)은 전체 토지이용중 도시지역이 $75.9\%$를 차지하고, 유역내 인구가 120만명에 이르는 도시유역으로 높은 불투수 면적비율, 인공계 물순환 요소의 영향 등의 도시 유역 특성이 물순환의 구조 전반에 미치는 영향에 대한 연구가 부족하였다. WEP 모형 적용 결과, 모의 기간 동안의 하천 유출량은 실측치에 근사한 값을 나타내었으며 유역의 물순환 양상을 모의할 수 있었다. 청계천 유역은 전형적인 도시 유역의 특성을 보여주었는데, 강우시의 직접유출이 크고, 강우의 유출에 대한 반응이 빠르며, 증발산의 경우는 산림지역보다 도시지역이 상대적으로 적은 것으로 분석되었다. 이번 연구를 통하여 WEP 모형이 유역 물순환 해석에 적절한 모형임을 확인할 수 있었으면, 향후 청계천 유역의 물리적 특성에 대한 매개변수와 인공계 물순환 자료의 보완을 통해 보다 향상된 모의가 가능할 것으로 판단된다. 하였던 Cd과 Mg이 Ca 및 Ca과 vitamin D의 동시(同時) 급여(給與)로 감소(減少)하였고 Cu는 전체적(金體的)으로 변화(變化)가 없었으며 Zn은 Cd 급여(給與)로 감소(減少)하였으나 Ca과 vitamin D의 급여(給與)에 의하여 증가(增加)하였고 Ca은 Ca과 viamin D의 급여(給輿)로 유의(有意)하게 증가(增加)하였다. 신장(腎臟)중의 무기질(無機質) 함량(含量)은 Cd급여(給輿)로 Cu, Mg은 감소(滅少)하였으나 Ca, Zn은 변화(變化)가 없었고 Ca 및 Ca과 Vitamin D의 급여(給與)로 Cd, CU, Zn은 증가(增加)하였다.ce area)는 수술 전100.8$\pm$25.6 mm/$m^{2}$에서 79.3$\pm$ 15.8 mm/$m^{2}$로 감소한 소견을 보였다. 승모판 성형술은 전 승모판엽 탈출증이 있는 두 환아에서 동시에 시행하였다. 수술 후 1년 내 시행한 심초음파에서 모든 환아에서 단지 경등도 이하의 승모판 폐쇄 부전 소견을 보였다. 수술 후 조기 사망은 없었으며, 합병증으로는 유미흉이 한 명에서 있었다. 술 후 10개월째 허혈성 확장성 심근증이 호전되지 않아 Dor 술식을 시행한 후 사망한 예를 제외한 나머지 6명은 특이 증상 없이 정상 생활 중이다 결론: 좌관상동맥 페동맥이상 기시증은 드물기는 하나, 영유아기에 심근경색 및 허혈성 심근증 또는 선천성 승모판 폐쇄 부전등을 초래하는 심각한 선천성 심질환이다. 그러나 진단 즉시 직접 좌관상동맥-대동맥 이식술로 수술적 교정을 해줌으로써 좋은 성적을 기대할 수 있음을 보여주었다.특히 교사들이 중요하게 인식하는 해방적 행동에 대한 목표를 강조하여 적용할 필요가 있음을 시사하고 있다.교하여 유의한 차이가 관찰되지 않았다. 또한 HSP 환자군에서도 $IL1RN^{*}2$ allele 빈도와 carriage

  • PDF

Characteristics of Lode Development and Structural Interpretation for the High Au Contents within the Fault Gouge Zones in Jinsan Au Mine, Chungcheongnam-do (충남 금산 진산금광산의 광맥 발달특성과 단층점토에 농집된 고품위 금함량에 대한 구조지질학적 해석)

  • Shin, Dongbok;Gwon, Sehyeon;Kim, Young-Seog
    • Economic and Environmental Geology
    • /
    • v.48 no.2
    • /
    • pp.103-114
    • /
    • 2015
  • Jinsan gold deposit is a hydrothermal vein type deposit consisting of several fissure filling quartz veins developed within the Changri Formation of the Ogcheon Supergroup in Geumsan, Chungnam. This study is to provide an efficient exploration and development strategies based on the characteristics of the geology, geological structure, core logging, and ore vein occurrence and grade for the four pits (New pit, Main pit, Yanghapan pit and Teugho pit). Quartz veins are mostly developed with the strike of $N10^{\circ}-25^{\circ}W$ and $N5^{\circ}-20^{\circ}E$, and the thickness is in the range of 0.1~0.5 m, sometimes extending to over 1m. Although the quartz veins commonly form massive shape, they sometimes show zonal structure, comb structure as well as brecciated texture. Major ore minerals are pyrite and chalcopyrite, and pyrrhotite, sphalerite, galena, marcasite, electrum and chalcocite are also accompanied as minor phases. Gray and milky white quartz veins, which are occasionally crosscut by calcite vein, also include fluorite. Ore evaluations for the 22 samples revealed that the samples from the pits generally have very low Au contents, lower than 1 g/t, but some clay samples of drilled core show very high Au concentrations, up to 141 g/t, indicating that Au content is much higher within fault gouges rather than within fresh quartz veins. This may represent that gold might have been reworked and reprecipitated by hydrothermal fluids in association with reactivation of the faults, and thus suggest that ore occurrence in this deposit is very complex and irregular and therefore more precise and systematic exploration is required.

The Comparison of the Solar Radiation and the Mean Radiant Temperature (MRT) under the Shade of Landscaping Trees in Summertime (하절기 조경용 녹음수 수관 하부의 일사와 평균복사온도 비교)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.42 no.5
    • /
    • pp.22-30
    • /
    • 2014
  • The purpose of this study was to compare the Solar Radiation(SR) and the Mean Radiant Temperature(MRT) under the shades of the three landscaping trees in clear summer daytimes. The trees were Lagerstroemia indica, Quercus palustris and Ulmus parvifolia. The solar radiation, the globe temperature and the air temperature were recorded every minute from the $1^{st}$ of April to the $30^{th}$ of September 2013 at a height of 1.1m above on the four monitoring stations, with four same measuring system consisting of a solar radiation sensor, two resistance temperature detectors(Pt-100), a black brass globe (${\phi}50mm$) and data acquisition systems. At the same time, the sky view photos were taken automatically hourly by three scouting cameras(lens angle: $60^{\circ}$) fixed at each monitoring station. Based on the 258 daily sky view photos and 6,640 records of middays(10 A.M.~2 P.M.) from the $1^{st}$ of June to the $30^{th}$ of August, the time serial differences of SR and MRT under the trees were analysed and compared with those of open sky, The major findings were as follows; 1. The average ratio of sky views screened by the canopies of Quercus palustris, Lagerstroemia indica and Ulmus parvifolia were 99%, 98% and 97%, and the SR were $106W/m^2$, $163W/m^2$ and $202W/m^2$ respectively, while the SR of open sky was $823W/m^2$. Which shows the canopies blocked at least 70% of natural SR. 2. The average MRT under the canopies of Quercus palustris, Lagerstroemia indica and Ulmus parvifolia were $30.34^{\circ}C$, $33.34^{\circ}C$ and $34.77^{\circ}C$ respectively, while that of open sky was $46.0^{\circ}C$. Therefore, it can be said that the tree canopies can reduce the MRT around $10{\sim}16^{\circ}C$. 3. The regression test showed significant linear relationship between the SR and MRT. In summary, the performances of the landscaping shade trees were very good at screening the SR and reducing the MRT at the outdoor of summer middays. Therefore, it can be apparently said that the more shade trees or forest at the outdoor, the more effective in conditioning the outdoor space reducing the MRT and the useless SR for human activities in summertime.

DC Electric Field Characteristics considering Thermal Effect for HVDC Slip-on Type Outdoor Termination (HVDC 슬립 온형 기중 종단접속함에 대한 열 영향 반영 DC 전계 특성 평가)

  • Kwon, Ik-Soo;Hwang, Jae-Sang;Koo, Jae-Hong;Sakamoto, Kuniaki;Lee, Bang-Wook
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.39-46
    • /
    • 2015
  • A outdoor termination installed at the outdoor substation is required to connect undergroud cables and overhead transmission lines. The joint box for AC transmission system is already developed and widely used to interconnect overhead and undergroud systems. But the development of the joint box for DC transmission system was only introduced from China and Japan, but theire developemnt staus and core technologies were not fully reported. In order to implement HVDC systems connecting ovehead transmission lines and undergroud cables, a outdoor termination should be developed, but the detailed specifications and information of this device were not reported. It is estimated that the development of the joint box for DC environment has some technical obstacles including insulating materials, electric field mitigation, thermal temperature rise, and space charge accumuations. Among this, the most important one is the DC elctrical insualtion design. Therefore, in order to investigate the DC elctrical insualton design of outdoor termination, the design of AC slip-on type outdoor termination is reffered, and DC electric field analysis performed to verify the possiblity of application of AC joint box into DC joint box. Especially for DC electric field analysis, temperature rise of insualting materials of a joint box was considered, because the conductivity of materials could be changed due to temperature rise. Furthermore, DC electric field analysis considering transinet state, and polarity reversal state were also investigated to verify which state is the most severe condition for the DC joint box. From the simualtion resulsts, it was shown that the value and the position of maximum electric field was obtained comparing AC state, DC state without temperaure rise, and DC state with temperaure rise. And it was confimred that severe DC electric field was observed considing temperaure rise. Finally, in order to reduce DC eletric field intensifation, different configuration of the joint box was applied and it was not possible to obtain satisfactory results. It means that the slight change of configuration of AC joint box was not the suitable soluton for DC joint box. It is essential to establish novel DC insulaton design skills and method for DC joint box to commercialze this product in the near future.

A Study on the Nature-friendly Management Regarding the User Pattern of Yangjae Stream (양재천의 이용특성을 고려한 환경친화적 관리방안에 관한 연구)

  • Kim Sun-Hee;Hong Suk-Hwan;Bae Jung-Nam
    • Korean Journal of Environment and Ecology
    • /
    • v.18 no.3
    • /
    • pp.306-315
    • /
    • 2004
  • Yangjae stream, stretching through Seocho-gu and Gangnam-gu, is a representative city stream with its environmentally friendly stream makeover project model, launched in 1995. The district of Gangnam-gu, the subject of this study, is under high pressure from the residents for its use as a huge residential areas close to the stream. The study has two main purposes. The first is to identify the condition and characteristic of utilization of Yangjae stream which is currently being increased in use by the stream restoration. Secondly, the study aims to suggest the environment-friendly management to accomplish arrangement of the naturally friendly stream based on the identification survey, The result from the user survey with 303 valid answer sheets show that the people from neighboring residential areas use this stream a lot doing exercising(51.8%) and taking a walk(24.4%) in their free time. Also regular use rate is high, and people are likely to use it alone(30.4%) or as a family(28.4%). With regard to the need of facility increase, even though the respondents required resting places in the shade(80.8%) most, overall, additional introduction of facilities was analyzed as unnecessary(78.8%). safety issue(22.0%) and a lack of convenience facilities(17.6%) and resting places in the shade(16.6%) are pointed as main problems while the users are generally satisfied(59.5%) with the stream. Improving walk-way and planting trees for shade on the slope were designed as a solution for these problems. For securing safety through improvement of walk-way, the scattering of pressure of current walk with building new walk using berms was presented. In order to increase safety on the walk-way(see above figure), the study proposes to build a new walk-way with berms to disperse excessive pressure. It also suggests the tree planting to provide shade in the stream and to make a provision for the planting of forest trees in the current law.

A COMPARATIVE STUDY ON THE PHYSICAL PROPERTIES OF ORTHODONTIC PLIERS ACCORDING TO TYPES OF STERILIZATION (멸균 방법에 따른 교정용 플라이어의 물성 변화에 대한 비교 연구)

  • Cho, Il-Je;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.28 no.2 s.67
    • /
    • pp.329-341
    • /
    • 1998
  • Sterilization has received much attention in orthodontic practices over the past several years. The present study was undertaken to investigate the effects of sterilization on the physical properties of orthodontic pliers-AEZ, Unitek, and Dentronix ligature cutters. This study was designed to examine the tips of ligature cutters before and after 200 and 400 sterilization cycles using the Bowmar RHT-1000, the Dentronix DDS-5000, and the Eschmann SES-2000. The tip surface and the fracture surface were observed with a scanning electron microscope. The microstructure was observed with an optical microscope. The hardness test was carried out with the mic개-Vickers hardness tester and the Rockwell C Scale hardness tester. The chemical composition was analyzed by energy dispersive X-ray spectrometer. The results of this study were as follows : 1. The number and the size of corrosion products on the tip surface and the proportion of cleavage planes in fractured specimen increased, but the hardness of the tip decreased in proportion to sterilization cycles. From these observations, it was considered that mechanical properities decreased in proportion to sterilization cycles. 2. The number and the size of chromium carbides increased in proportion to sterilization cycles. Coarse microstructure decreased mechanical properities. 3. The AEZ and Unitek ligature cutters were Fe-Cr stainless steels, but the Dentronix ligature cutter was Co-Cr alloy. There were many differences among manufactures, but the chemical composition was .not changed after sterilization cycles. 4. The tip edge of ligature cutter used in a clinic revealed microcracks with the SEM observation. Clinical experience confirmed that ligature cutters were gradually degraded by sterilization.

  • PDF

Chemical and Physical Characteristics of Four Weed Seed Fibers (Hemistepta lyrata, Imperata cylindrica var. koenigii, Metaplexis japonica and Typha latifolia) (지칭개, 띠, 박주가리, 큰부들 잡초종자섬유의 물리화학적 특성)

  • Yoon, A Ra;Lee, Min Woo;Kim, Seul Ki;Kim, Jin-Seog
    • Weed & Turfgrass Science
    • /
    • v.3 no.4
    • /
    • pp.253-261
    • /
    • 2014
  • In this study, we investigated several chemical and physical characteristics of 4 weed seed fibers; Hemistepta lyrata (HEMLY), Imperata cylindrica var. koenigii (IMPCK), Metaplexis japonica (METJA) and Typha latifolia (TYPLA). In chemical composition, there were 74 (TYPLA)-88.5% (METJA) of holocellulose, 17 (IMPCK)-24% (METJA) of lignin, 0.22 (METJA)-4.2% (IMPCK) of ash, 2.2 (HEMLY)-7.8% (IMPCK) of hot water extractives and 0.4 (IMPCK)-6.3% (TYPLA) of solvent extractives. Alpha-cellulose proportion to holocellulose was similar among weed seed fibers as 45-48%. The crystallinity index (CI) of raw seed fibers was 53.2 (TYPLA)-65.9% (HEMLY). However, CI of the chemical treated fibers (EDA fibers) was a little increased and showed 61.1 (IMPCK)-71.8% (METJA). The maximum thermal decomposition temperature (MTDT) of the raw seed fibers were 312, 321.8, 331.5 and $341.6^{\circ}C$ in METJA, TYPLA, HEMLY and IMPCK, respectively. But the MTDT of the EDA fibers were 327, 327, 341.7 and $360.0^{\circ}C$ in HEMLY, TYPLA, METJA and IMPCK, respectively. Taken together, they showed a similar or better characteristics compared to the reported or commercial natural fiber resourses. Accordingly, they seem to be practically applicable as renewable resources for a new natural fibers.

A Study of Injection Dose for Patients and Exposure Dose for Technologists from the PET/CT Systems (PET/CT 장비 특성에 따른 방사성 의약품 주입량이 방사선 종사자에게 미치는 영향)

  • Park, Hoon-Hee;Oh, Ki-Beak;Lee, Seung-Jae;Bhan, Young-Kag;Kang, Chun-Goo;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.45-50
    • /
    • 2011
  • Purpose: It appears the different value when the injection dose is calculating for patients on each PET/CT systems. It directly affects the technologists' radiation exposed dose. We studied the effect of the variable injection doses from several PET/CT systems to exposure dose for technologists. Materials and Methods: Six technologists have worked for 5 months through unit rotations with 3 PET/CT systems {Scanner 1 (S1): 0.15 mCi/kg, Scanner 2 (S2): 0.17 mCi/kg, Scanner 3 (S3): 0.12 mCi/kg}. Eighteen to 19 patients have had examinations per a day on each PET/CT systems. Examination parameters were adjusted to the same. TLDs were used for checking the exposure dose of technologists. Results: Each technologists' the monthly average exposure dose was as follows; S1: 0.76 mSv, S2: 0.93 mSv, S3: 0.47 mSv. The maximum exposure dose was 1.12 mSv, and minimum was 0.42 mSv. The results showed significance in the correlation between the PET/CT system and the exposure dose (p<0.005). Conclusion: When the amount of injection dose was small, the exposure dose was decreased not only the patients but also the technologists. The exposure dose was decreased by the individual proficiency of technologists. However, the low injection dose can highly reduce the exposure dose for technologist so that there will be needed to following studies.

  • PDF

Analysis of Groundwater Flow Characterization in Fractured Aquifer System (파쇄대 응회암 대수층의 지하수 유동 특성화 기법)

  • Kim Yong-Je;Kim Tae-Hee;Kim Kue-Young;Hwang Se-Ho;Chae Byung-Gon
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.4
    • /
    • pp.33-44
    • /
    • 2005
  • On the basis of a stepwise and careful integration of various field and laboratory methods the analysis of groundwater flow characterization was performed with five boreholes (BH-1, -2, -3, -4, -5) on a pilot site of Natural Forest Park in Guemsan-gun, Chungcheongbook-do, Korea. The regional lineaments of NW-SE are primarily developed on the area, which results in the development of many fractures of NW-SE direction around boreholes made in the test site for the study. A series of surface geological survey, core logging, geophysical logging, tomography, tracer tests, and heat-pulse flowmeter logging were carried out to determine fracture characteristics and fracture connectivity between the boreholes. In the result of fracture connectivity analysis BH-1 the injection well has a poor connectivity with BH-2 and BH-3, whereas a good with BH-4 and BH-5. In order to analyse the hydraulic connectivity between BH-1 and BH-5, in particular, a conspicuous groundwater outflux in the depth of 12 m and influx in the depth of 65 m and 70 m, but partly in/outflux occurred in other depths in BH-5 were observed as pumping from BH-1. On the other hand, when pumping from BH-5 the strong outflux in the depths of 17 m and 70 m was occurred. The spatial connectivity between the boreholes was examined in the depth of 15 m, 67 m, and 71 m in BH-1 as well as in the depth of 15 m, 17 m, 22 m, 72 m, and 83 m in BH-5.