• Title/Summary/Keyword: 연소전포집

Search Result 31, Processing Time 0.026 seconds

Feasibility Study of Employing a Catalytic Membrane Reactor for a Pressurized CO2 and Purified H2 Production in a Water Gas Shift Reaction

  • Lim, Hankwon
    • Clean Technology
    • /
    • v.20 no.4
    • /
    • pp.425-432
    • /
    • 2014
  • The effect of two important parameters of a catalytic membrane reactor (CMR), hydrogen selectivity and hydrogen permeance, coupled with an Ar sweep flow and an operating pressure on the performance of a water gas shift reaction in a CMR has been extensively studied using a one-dimensional reactor model and reaction kinetics. As an alternative pre-combustion $CO_2$ capture method, the feasibility of capturing a pressurized and concentrated $CO_2$ in a retentate (a shell side of a CMR) and separating a purified $H_2$ in a permeate (a tube side of a CMR) simultaneously in a CMR was examined and a guideline for a hydrogen permeance, a hydrogen selectivity, an Ar sweep flow rate, and an operating pressure to achieve a simultaneous capture of a concentrate $CO_2$ in a retentate and production of a purified $H_2$ in a permeate is presented. For example, with an operating pressure of 8 atm and Ar sweep gas for rate of $6.7{\times}10^{-4}mols^{-1}$, a concentrated $CO_2$ in a retentate (~90%) and a purified $H_2$ in a permeate (~100%) was simultaneously obtained in a CMR fitted with a membrane with hydrogen permeance of $1{\times}10^{-8}molm^{-2}s^{-1}Pa^{-1}$ and a hydrogen selectivity of 10000.

Thermodynamic and Spectroscopic Analysis of Gas Hydrate-Based $CO_2$ Separation Process (가스 하이드레이트 기반 $CO_2$ 분리 공정의 열역학적 및 분광학적 해석)

  • Park, Sungmin;Lee, Seungmin;Lee, Youngjun;Kim, Yunju;Seo, Yongwon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.146.1-146.1
    • /
    • 2011
  • 석탄가스화복합발전(IGCC)공정에서 가스화기를 거쳐 생성된 합성가스로부터 $CO_2$를 효과적으로 분리/회수하기 위해 가스 고형화법을 제안하였다. 가스 하이드레이트 형성과정에서의 반응특성을 살펴보기 위하여 반응시간에 따른 가스소모량과 기상의 $CO_2$ 조성 변화를 측정하였다. 순수계와 촉진제 첨가계 (TBAB (10, 40 wt%), TBAF (10, 34 wt%), THF (4, 19 wt%))에 대하여 하이드레이트 생성 후의 기상과 하이드레이트상의 $CO_2$ 조성을 측정하였으며, 그 결과 하이드레이트 형성법에 의해 고농도의 $CO_2$가 하이드레이트상에 포집되는 것을 확인하였다. 가스 소모량 측정실험에서는 THF 19.1 wt%를 첨가하였을 때 가장 큰 소모량을 보였으며, TBAF 10 wt%를 첨가하였을 때 가장 적은 가스소모량을 보였다. $CO_2$ 조성 변화 실험에서는 가스 소모량 실험과 마찬가지로 THF 19.1 wt%를 첨가하였을 때 가장 큰 조성변화를 보였다. 이는 THF의 첨가로 인하여 가스 하이드레이트로의 전환율 증가로 많은 양의 $CO_2$ 기체가 하이드레이트 상에 포집되었음을 나타낸다. 속도론적인 측면에서는 모든 실험조건에서 하이드레이트 형성반응이 1시간 이내에 대부분 종결되는 것을 볼 수 있었다. 또한 $^1H$-NMR을 통하여 혼합가스 하이드레이트의 구조적인 분석을 진행하였다. 본 실험에서 얻어진 결과는 가스 하이드레이트 형성법을 이용한 합성가스 분리 공정 개발에 중요한 기초자료가 될 것으로 사료된다.

  • PDF

Hydrodynamic Characteristics of Absorbent and Catalyst for Pre-combustion CO2 Capture (연소 전 이산화탄소 회수를 위한 흡수제 및 촉매의 수력학적 특성)

  • Ryu, Ho-Jung;Yoon, Joo-Young;Lee, Dong-Ho;Shun, Dowon;Park, Jaehyeon;Park, Yeong-Seong
    • Clean Technology
    • /
    • v.19 no.4
    • /
    • pp.437-445
    • /
    • 2013
  • To develop SEWGS (sorption enhanced water gas shift) system using dry $CO_2$ absorbent for pre-combustion $CO_2$ capture, hydrodynamic characteristics of $CO_2$ absorbents were measured and investigated. The minimum fluidization velocity of $CO_2$ absorbent was measured and the effects of the operating conditions were investigated to operate the system at bubbling fluidized bed condition. The minimum fluidization velocity decreased as pressure and temperature increased. Moreover, the minimum fluidization velocity decreased as column diameter increased. The effects of operating conditions on the solid circulation rate were measured and investigated to select appropriate operating conditions for continuous $CO_2$ capture and regeneration. The measured solid circulation rates were ranged between 10 and 65 kg/h and increased as the solid injection velocity, gas velocity in the regeneration reactor, and solid height increased.

Gas Hydrate Phase Equilibria of $CO_2+H_2$ Mixture in Silica Gel Pores for the Development of Pre-combustion Capture (연소 전 이산화탄소 회수기술을 위한 실리카겔 공극 내에서의 이산화탄소+수소 혼합가스 하이드레이트의 상평형)

  • Kang, Seong-Pil;Jang, Won-Ho;Jo, Wan-Keun
    • Clean Technology
    • /
    • v.15 no.4
    • /
    • pp.258-264
    • /
    • 2009
  • Thermodynamic measurements were performed to show the possibility of recovering $CO_2$ from fuel gas (the mixture of $CO_2$ and $H_2$) by forming gas hydrates with water where water was dispersed in the pores of silica gel particles having nominal 100 nm of pore diameter. The hydrate-phase equilibria for the ternary $CO_2+H_2$+water in pores were measured and $CO_2$ concentrations in vapor and hydrate phase were determined under the hydrate-vapor two phase region at constant 274.15 K. It was shown that the inhibition effect appeared due to silica gel pores, and the corresponding equilibrium dissociation pressures became higher than those of bulk water hydrates at a specific temperature. In addition, direct measurement of $CO_2$ content in the hydrate phase showed that the retrieved gas from the dissociation of hydrate contained more than 95 mol% of $CO_2$ when 42 mol% of $CO_2$ and balanced Hz mixture was applied. Compared with data obtained in case of bulk water hydrates, which showed just 83 mol% of $CO_2$ where 2-stage hydrate slurry reactor was intended to utilize this property, the hydrate formation in porous silica gel has enhanced the feasibility of $CO_2$ separation process. Hydrate formation as not for slurry but solid particle makes it possible to used fixed bed reactor, and can be a merit of well-understood technologies in the industrial field.

Research Trends of Polybenzimidazole-based Membranes for Hydrogen Purification Applications (수소 분리 응용을 위한 폴리벤즈이미다졸 기반 분리막의 연구 동향)

  • Kim, Ji Hyeon;Kim, Kihyun;Nam, Sang Yong
    • Applied Chemistry for Engineering
    • /
    • v.31 no.5
    • /
    • pp.453-466
    • /
    • 2020
  • As the demand for eco-friendly energy increases to overcome the energy shortage and environmental pollution crisis, hydrogen economy has been proposed as a potential solution. Accordingly, an economical and efficient hydrogen production is considered to be an essential industrial process. Research on applying hydrogen separation membranes for H2/CO2 separation to the production of highly concentrated hydrogen by purifying H2 and capturing CO2 simultaneously from synthetic gas produced by gasification is in progress nowadays. In high temperature environments, the membrane separation process using glassy polymeric membrane with H2 selectivity has the potential for CO2 capture performance, and is an energy and cost effective system since polybenzimicazole (PBI)-based separators show excellent chemical and mechanical stability under high-temperature operation conditions. Thus, the development of high-performance PBI hydrogen separators has been rapidly progressing in recent years. This overview focuses on the recent developments of PBI-based membranes including structure modified, cross-linked, blended and carbonized membranes for applications to the industrial hydrogen separation process.

Experimental Study on N2 Impurity Effect in the Pressure Drop During CO2 Mixture Transportation (CO2 파이프라인 수송에서의 N2 불순물이 압력강하에 미치는 영향에 대한 실험적 연구)

  • Cho, Meang-Ik;Huh, Cheol;Jung, Jung-Yeul;Baek, Jong-Hwa;Kang, Seong-Gil
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.15 no.2
    • /
    • pp.67-75
    • /
    • 2012
  • Carbon-dioxide capture and storage (CCS) process is consisted by capturing carbon-dioxide from large point source such as power plant and steel works, transporting and sequestrating captured $CO_2$ in a stable geological structure. During CCS process, it is inevitable of introducing impurities from combustion, capture and purification process into $CO_2$ stream. Impurities such as $SO_2$, $H_2O$, CO, $N_2$, Ar, $O_2$, $H_2$, can influence on process efficiency, capital expenditure, operation expense of CCS process. In this study, experimental apparatus is built to simulate the behavior of $CO_2$ transport under various impurity composition and process pressure condition. With this apparatus, $N_2$ impurity effect on $CO_2$ mixture transportation was experimentally evaluated. The result showed that as $N_2$ ratio increased pressure drop per mass flow and specific volume of $CO_2-N_2$ mixture also increased. In 120 and 100 bar condition the mixture was in single phase supercritical condition, and as $N_2$ ratio increased gradient of specific volume change and pressure drop per mass flow did not change largely compared to low pressure condition. In 70 bar condition the mixture phase changed from single phase liquid to single phase vapor through liquid-vapor two phase region, and it showed that the gradient of specific volume change and pressure drop per mass flow varied in each phase.

Effect of Pressure on HCl Absorption Behaviors of a K-based Absorbent in the Fixed Bed Reactor (고정층 반응기에서 K-계열 흡수제의 압력에 따른 HCl 흡수 거동 연구)

  • Kim, Jae-Young;Park, Young Cheol;Jo, Sung-Ho;Ryu, Ho-Jung;Baek, Jeom-In;Park, Yeong Seong;Moon, Jong-Ho
    • Clean Technology
    • /
    • v.19 no.2
    • /
    • pp.165-172
    • /
    • 2013
  • In this study, the hydrogen chloride removal using K-based dry sorbents ($K_2CO_3/Al_2O_3$, KEPRI, Korea) was studied with varying the pressure in a fixed bed reactor (15 cm tall bed with 0.5 cm I.d.). Working temperature was $400^{\circ}C$ and feed gas concentration was 750 ppm (HCl vol%, $N_2$ balance). The chloride sorption capacity of sorbent increases with increasing pressure (1, 5, 10, 15 and 20 bar). Also, after forming KCl crystal by reaction with $K_2CO_3$ and HCl, owing to the strong bonding energy, sorbent regeneration was practically impossible. Its optical, physical and chemical characterizations were evaluated by SEM, EDAX, BET, TGA and XRD. At $400^{\circ}C$ and 20 bar condition, working condition for the dehalogenation process after gasification, K-based dry sorbent showed high HCl sorption capacity and HCl/$N_2$ separation performances comparing with Ca-based and Mg-based dry sorbents.

A Study on the Characteristics of Coffee Ground(CG)-RDF by Using Different Drying Method (건조법에 따른 커피박 고형연료의 특성 고찰 연구)

  • Kim, Sang-bin;Ha, Jin-wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.451-457
    • /
    • 2019
  • In this study, the characteristics of coffee grounds were reviewed by making them from solid fuel through heat-drying and oil-drying method. The differences in the higher calorific power by each dried sample were compared. And industrial analysis using the thermogravimetric analyzer was considered for applicability to organic waste and oily samples. Before and after drying, the surface of the specimen was observed with SEM equipment and the ingredients were measured through the EDS equipment. As a result, no other hazardous substances, such as heavy metals, were measured. Next, The differences between thermal decomposition and combustion reactions were considered through the TG and DTG curves. As a result, it is that the oil-dried coffee grounds is longer to burn than the heat-dried coffee grounds. Finally, the combustion gases emitted through the thermogravimetric analyzer were collected and the carbon monoxide and carbon dioxide performed qualitative and quantitative analysis using GC over time.

Simultaneous Removal of SOx and NOx in Flue Gas of Oxy-fuel Combustion by Direct Contact Condenser (직접접촉식 응축기를 통한 가압순산소 연소 배가스 내 SOx, NOx 동시저감 연구)

  • Choi, Solbi;Mock, Chinsung;Yang, Won;Ryu, Changkook;Choi, Seuk-Cheon
    • Clean Technology
    • /
    • v.25 no.3
    • /
    • pp.245-255
    • /
    • 2019
  • Pressurized oxy-fuel combustion is a promising technology for $CO_2$ capture with a benefit of improving power plant efficiency compared with atmospheric oxy-fuel combustion. Prior to $CO_2$ compression in this process, a flue gas condenser (FGC) is used to remove $H_2O$ while recovering the latent heat. At the same time, the FGC has a potential for high-efficiency removal of $SO_x$ and $NO_x$ by exploiting their good solubility in water. In this study, experiments were carried out in a lab-scale, direct contact FGC under different pressures varying between 1 and 20 bar to evaluate the removal efficiency of $SO_2$ and $NO_x$ for individual gases and their mixture. In the tests for individual gases, 20% and 76% of $NO_x$ was removed at 1 bar and 10 bar, respectively. Even higher removal efficiencies were achieved for $SO_2$, and also these were maintained for longer as the pressure increased. In the tests for $SO_2$ and $NO_x$ mixture, the removal efficiency of $NO_x$ increased from 13% at 1 bar to 56% at 20 bar because of higher solubility at elevated pressures. $SO_2$ in the mixture was initially dissolved almost completely and then increased by 1,219 ppm at 1 bar and by 165 ppm at 20 bar. Overall, the removal efficiency of $SO_2$ and $NO_x$ was increased at elevated pressures, but it was lower in the mixture compared with individual gases at identical conditions because of a lower pH and associated chemical reactions in water.

Characteristics and Sampling of Dioxins/Furans from Emission Gas and Fly Ash Produced in Municipal Waste Incinerator (도시 소각로 쓰레기 소각후 생성된 폐가스 및 비산재중에 포함된 다이옥신류의 측정 및 특성고찰)

  • Lim, Chae-Hyun;Kim, Hee-Taik;Sohn, Jung-Hyun;Chang, Yoon-Seok
    • Applied Chemistry for Engineering
    • /
    • v.8 no.5
    • /
    • pp.790-795
    • /
    • 1997
  • Polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofuransfurans are the archetype of toxic chemicals. So it has absorbed public attention. The majors primary sources of PCDDS and PCDFs are chemical, thermal and photochemical reactions. Municipal solid waste incinerator facilities has been reported as the major contributors of dioxins to the environment. In this paper, Dioxins and furans were examined emission gas and fly ash produced during combustion in municipal solid waste incinerator. More effective method for sampling, extraction was described. The sample was extracted using a soxhlet method and purified using silicagel, alumina and carbon fibre HPLC to remove interfering compound. The extract was then analyzed by HRGC/HRMS. The result of this study showed recovery standard was good and the data resembled those of thermal processes. Total dioxins and furans were $1076.20pg/Nm^3$ and $1452.34pg/Nm^3$ respectively. The amount of highly chlorinated compound was more than that of lowly chlorinated compound. The 2,3,7,8-substituted TCDD was Just 0.34% of the total dioxins/furans amount.

  • PDF