• Title/Summary/Keyword: 연소배가스

Search Result 86, Processing Time 0.022 seconds

A Study for Failure Examples Including with Engine Oil Leakage, Poor Contact by Fin Damage and Vaporizer Inferiority on LPG Automotive (LPG 자동차의 엔진오일누설, 핀 손상에 의한 접촉불량, 베이퍼라이저 내부불량으로 인한 고장사례연구)

  • IL Kwon, Lee;Chang Ho, Kook;Sung Hoon, Ham;Seung Yong, Lee;Jae Gang, Lee;Seung Min, Han; Woo Chan, Hwang;Dae Cheon, Jang;Chang Bae, You;Jeong Ho, Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.6
    • /
    • pp.24-29
    • /
    • 2022
  • This paper is a purpose to Analyze and study the failure examples for a engine oil leakage of camshaft bearing seal, poor contact by computer connector fin damage and vaporizer inferiority on LPG automotive. The first example, when the researcher disassembled the cylinder head of engine to establish the cause for oil leakage, he confirmed the engine oil leakage by damaged between the engine intake camshaft bearing and seal part. The second example, the connector fin of power source line that control the starting of a car supplied with engine computer. As a result, it found the fact that the engine operation stopped because of cutting of the power source by connector fin damage. The third example, it verified the engine incongruity phe cutting of the power source by connector fin damage. The third example, it verified the engine incongruity phenomenon as thd gas didn't flow the vaporizer by foreign substance deposit. Finally, it supplied a small quantity gas from vaporizer to mix. As the computer controlling mix opening condition supplied a air as opening signal, the air and fuel became rarefied state. it knew that the engine didn't produce prpper power. Therefore, a car have to throughtly inspect not in order to arise the failure symptoms.

A study on permeation of $CO_2-N_2-O_2$ mixed gases through a NaY zeolite membrane under permeate evacuation mode (진공모드에서 NaY 제올라이트 막의 $CO_2-N_2-O_2$ 혼합기체의 투과거동 연구)

  • Jeong, Su Jung;Yeo, Jeong-Gu;Han, Moon Hee;Cho, Churl Hee
    • Membrane Journal
    • /
    • v.23 no.5
    • /
    • pp.352-359
    • /
    • 2013
  • In the present study, $CO_2$ permeation through a hydrophilic NaY zeolite membrane was studied under permeate evacuation mode for $CO_2$ single gas, $CO_2-N_2$ and $CO_2-O_2$ binary mixtures, and $CO_2-N_2-O_2$ ternary mixture. It was reconfirmed that the $CO_2$ permeation was governed by surface diffusion and the $CO_2$ selectivity was induced from blocking effect of adsorbed $CO_2$ molecules. The $CO_2$ permeance measured in permeate evacuation mode was much lower than that done in He sweeping mode, but was comparable to that obtained under feed pressurization mode. The NaY zeolite membrane showed a considerable $CO_2$ separation for $14%CO_2-80%N_2-6%O_2$ mixture : $CO_2$ permeance was about $1{\times}10^{-7}mol/m^2secPa$ and $CO_2$ selectivity was more than 10. Therefore, it was concluded that NaY zeolite membrane was one of promising membranes for post-combustion CCS process.

Study for Failure Examples Including with Gas filter Clogging of Emergency Cutting Valve, Assemblying Part Damage of Solenoid Valve, Contact Damage of LPG Switch Connector Fin in a LPG Car (LPG 자동차의 긴급차단밸브 기상필터막힘, 솔레노이드밸브 조립부손상, LPG 스위치 커넥터 핀 접촉불량에 관련된 고장사례 연구)

  • Lee, IL Kwon;Kook, Chang Ho;Ham, Sung Hoon;Kim, Jee Hyun;Kim, Sung Mo;Jung, Dong Hwa;You, Chang Bae;Moon, Hak Hoon;Lee, Jeong Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.1
    • /
    • pp.1-6
    • /
    • 2022
  • This paper is a purpose to study and analyze the engine starting failure examples for LPG car. The first example, the researcher verified the phenomenon that didn't supply the fuel because of filter clogging by fine alien substance in the gas valve line when he inspected the emergency cutting valve. The second example, there was no the influence of gas leakage when the solenoid operated at first. But the damage part of solenoid assemblying face wad downed a durability according to running a valve. Eventually, the researcher checked on the phenomenon of engine stopping by no gas feeding in solenoid because of leaking of gas. The third example, the researcher sought that the wiring sheaths of connector fin between EGR 10A fuse and LPG switch verified the burn-out phenomenon due to the bad contacting as tension damage produced the overheating. Therefore, the manager of a car has to do pre-inspection no producing electric failure and he must maintain his car with optimum condition.

A Study on the Thermodynamic Analysis and the Computer Simulation for the $CO_2$ and $H_{2}S$ Capture Process Using Methanol as a Solvent (메탄올 용매를 이용한 이산화탄소와 황화수소 포집공정의 열역학적 해석 및 전산모사에 관한 연구)

  • Cho, Jung-Ho;Lee, Ji-Hwan
    • Clean Technology
    • /
    • v.14 no.4
    • /
    • pp.287-292
    • /
    • 2008
  • In this study, computer simulation works have been performed for the capture process of the $CO_2$ and $H_{2}S$ gases contained in the effluent stream using methanol aqueous solution. In order to increase the solubilities of the $CO_2$ and $H_{2}S$ in the methanol aqueous stream, the operating pressure of the absorber was raised to 30 bar and the feeding temperature of the solvent was lowered to $-20^{\circ}C$ by using refrigeration cycle. NRTL liquid activity coefficient model was used to estimate the liquid phase nonidealities for methanol and water. Soave-Redlich-Kwong equation of state was used for the vapor phase nonidealities. Henry's law option was also used to calculate the solubilities of the supercritical noncondensible gases into the methanol aqueous solvent stream.

  • PDF

Environmental Pollution in Korea and Its Control (우리나라의 환경오염 현황과 그 대책)

  • 윤명조
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1972.03a
    • /
    • pp.5-6
    • /
    • 1972
  • Noise and air pollution, which accompany the development of industry and the increase of population, contribute to the deterioration of urban environment. The air pollution level of Seoul has gradually increased and the city residents are suffering from a high pollution of noise. If no measures were taken against pollution, the amount of emission of pollutant into air would be 36.7 thousand tons per year per square kilometer in 1975, three times more than that of 1970, and it would be the same level as that of United States in 1968. The main sources of air pollution in Seoul are the exhaust has from vehicles and the combustion of bunker-C oil for heating purpose. Thus, it is urgent that an exhaust gas cleaner should be instaled to every car and the fuel substituted by less sulfur-contained-oil to prevent the pollution. Transportation noise (vehicular noise and train noise) is the main component of urban noise problem. The average noise level in downtown area is about 75㏈ with maximum of 85㏈ and the vehicular homing was checked 100㏈ up and down. Therefore, the reduction of the number of bus-stop the strict regulation of homing in downtown area and a better maintenance of car should be an effective measures against noise pollution in urban areas. Within the distance of 200 metres from railroad, the train noise exceeds the limit specified by the pollution control law in Korea. Especially, the level of noise and steam-whistle of train as measured by the ISO evaluation can adversely affect the community activities of residents. To prevent environmental destruction, many developed countries have taken more positive action against worsening pollution and such an action is now urgently required in this country.

  • PDF

Air Pollution and Its Effects on E.N.T. Field (대기오염과 이비인후과)

  • 박인용
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1972.03a
    • /
    • pp.6-7
    • /
    • 1972
  • The air pollutants can be classified into the irritant gas and the asphixation gas, and the irritant gas is closely related to the otorhinolaryngological diseases. The common irritant gases are nitrogen oxides, sulfur oxides, hydrogen carbon compounds, and the potent and irritating PAN (peroxy acyl nitrate) which is secondarily liberated from photosynthesis. Those gases adhers to the mucous membrane to result in ulceration and secondary infection due to their potent oxidizing power. 1. Sulfur dioxide gas Sulfur dioxide gas has the typical characteristics of the air pollutants. Because of its high solubility it gets easily absorbed in the respiratory tract, when the symptoms and signs by irritation become manifested initially and later the resistance in the respiratory tract brings central about pulmonary edema and respiratory paralysis of origin. Chronic exposure to the gas leads to rhinitis, pharyngitis, laryngitis, and olfactory or gustatory disturbances. 2. Carbon monoxide Toxicity of carbon monoxide is due to its deprivation of the oxygen carrying capacity of the hemoglobin. The degree of the carbon monoxide intoxication varies according to its concentration and the duration of inhalation. It starts with headache, vertigo, nausea, vomiting and tinnitus, which can progress to respiratory difficulty, muscular laxity, syncope, and coma leading to death. 3. Nitrogen dioxide Nitrogen dioxide causes respiratory disturbances by formation of methemoglobin. In acute poisoning, it can cause pulmonary congestion, pulmonary edema, bronchitis, and pneumonia due to its strong irritation on the eyes and the nose. In chronic poisoning, it causes chronic pulmonary fibrosis and pulmonary edema. 4. Ozone It has offending irritating odor, and causes dryness of na sopharyngolaryngeal mucosa, headache and depressed pulmonary function which may eventually lead to pulmonary congestion or edema. 5. Smog The most outstanding incident of the smog occurred in London from December 5 through 8, 1952, because of which the mortality of the respiratory diseases increased fourfold. The smog was thought to be due to the smoke produced by incomplete combustion and its byproduct the sulfur oxides, and the dust was thought to play the secondary role. In new sense, hazardous is the photochemical smog which is produced by combination of light energy and the hydrocarbons and oxidant in the air. The Yonsei University Institute for Environmental :pollution Research launched a project to determine the relationship between the pollution and the medical, ophthalmological and rhinopharyngological disorders. The students (469) of the "S" Technical School in the most heavily polluted area in Pusan (Uham Dong district) were compared with those (345) of "K" High School in the less polluted area. The investigated group had those with subjective symptoms twice as much as the control group, 22.6% (106) in investigated group and 11.3% (39) in the control group. Among those symptomatic students of the investigated group. There were 29 with respiratory symptoms (29%), 22 with eye symptoms (21%), 50 with stuffy nose and rhinorrhea (47%), and 5 with sore thorat (5%), which revealed that more than half the students (52%) had subjective symptoms of the rhinopharyngological aspects. Physical examination revealed that the investigated group had more number of students with signs than those of the control group by 10%, 180 (38.4%) versus 99 (28.8%). Among the preceding 180 students of the investigated group, there were 8 with eye diseases (44%), 1 with respiratory disease (0.6%), 97 with rhinitis (54%), and 74 with pharyngotonsillitis (41%) which means that 95% of them had rharygoical diseases. The preceding data revealed that the otolaryngological diseases are conspicuously outnumbered in the heavily polluted area, and that there must be very close relationship between the air pollution and the otolaryngological diseases, and the anti-pollution measure is urgently needed.

  • PDF

Effects of Multiple-Cycle Operation and SO2 Concentration on CO2 Capture Capacity of Three Limestones in a Fluidized Bed Reactor (유동층 반응기에서 세 가지 석회석의 CO2 흡수능력에 미치는 반복횟수와 SO2 농도의 영향)

  • Ryu, Ho-Jung
    • Applied Chemistry for Engineering
    • /
    • v.17 no.1
    • /
    • pp.44-51
    • /
    • 2006
  • Effects of multiple-cycle operation and $SO_2$ concentration on $CO_2$ capture characteristics of three limestones were investigated in a fluidized bed reactor. For each of these sorbents, the measured $CO_2$ capture capacity decreased as the number of cycles increased and as the $SO_2$ concentration increased. On the other hand, the $SO_2$ capture increased with the increased number of cycles and the $SO_2$ concentration. The total calcium utilization decreased as the number of cycles increased, but the effect of $SO_2$ concentrations on the total calcium utilization depended on the type of limestone. For Strassburg limestone, the total calcium utillization decreased with increasing $SO_2$ concentration. However, for Luscar and Danyang limestones, the total calcium utilization was almost independent of $SO_2$ concentration for the range investigated. The results showed that $SO_2$ in flue gas reduced the $CO_2$ capture capacity of limestone and that the sulfation pattern affected the $CO_2$ capture capacity.

Measurement of Sulfur Dioxide Concentration Using Wavelength Modulation Spectroscopy With Optical Multi-Absorption Signals at 7.6 µm Wavelength Region (7.6 µm 파장 영역의 다중 광 흡수 신호 파장 변조 분광법을 이용한 이산화황 농도 측정)

  • Song, Aran;Jeong, Nakwon;Bae, Sungwoo;Hwang, Jungho;Lee, Changyeop;Kim, Daehae
    • Clean Technology
    • /
    • v.26 no.4
    • /
    • pp.293-303
    • /
    • 2020
  • According to the World Health Organization (WHO), air pollution is a typical health hazard, resulting in about 7 million premature deaths each year. Sulfur dioxide (SO2) is one of the major air pollutants, and the combustion process with sulfur-containing fuels generates it. Measuring SO2 generation in large combustion environments in real time and optimizing reduction facilities based on measured values are necessary to reduce the compound's presence. This paper describes the concentration measurement for SO2, a particulate matter precursor, using a wavelength modulation spectroscopy (WMS) of tunable diode laser absorption spectroscopy (TDLAS). This study employed a quantum cascade laser operating at 7.6 ㎛ as a light source. It demonstrated concentration measurement possibility using 64 multi-absorption lines between 7623.7 and 7626.0 nm. The experiments were conducted in a multi-pass cell with a total path length of 28 and 76 m at 1 atm, 296 K. The SO2 concentration was tested in two types: high concentration (1000 to 5000 ppm) and low concentration (10 ppm or less). Additionally, the effect of H2O interference in the atmosphere on the measurement of SO2 was confirmed by N2 purging the laser's path. The detection limit for SO2 was 3 ppm, and results were compared with the electronic chemical sensor and nondispersive infrared (NDIR) sensor.

Effect of fuel component on nitrous oxide emission characteristics in diesel engine (디젤엔진에 있어서 연료의 성분이 아산화질소 배출에 미치는 영향)

  • Yoo, Dong-Hoon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.9
    • /
    • pp.1045-1050
    • /
    • 2014
  • $N_2O$(Nitrous Oxide) is known as the third major GHG(Green House Gas) following $CO_2$(Carbon Oxide) and $CH_4$(Methane). The GWP(Global Warming Potential) factor of $N_2O$ is 310 times as large as that of $CO_2$ because $N_2O$ in the atmosphere is very stable, and it becomes a source of secondary contamination after photo-degradation in the stratosphere. Investigation on the cause of the $N_2O$ formation have been continuously reported by several researchers on power sources with continuous combustion form, such as a boiler. However, in the diesel engine, research on $N_2O$ generation which has effected from fuel components has not been conducted. Therefore, in this research, author has investigated about $N_2O$ emission rates which was changed by nitrogen and sulfur concentration in fuel on the diesel engine. The test engine was a 4-stroke direct injection diesel engine with maximum output of 12 kW at 2600rpm, and operating condition of that was set up at a 75% load. Nitrogen and sulfur concentrations in fuel were raised by using six additives : nitrogen additives were Pyridine, Indole, Quinoline, Pyrrol and Propionitrile and sulfur additive was Di-tert-butyl-disulfide. In conclusion, diesel fuels containing nitrogen elements less than 0.5% did not affect $N_2O$ emissions in the all concentrations and kinds of the additive agent in the fuel. However, increasing of the sulfur additive in fuel increased $N_2O$ emission in exhaust gas.

Properties of quasi-noncombustible ultra-lightweight geopolymer (준불연 초경량 지오폴리머의 물성)

  • Kim, Yootaek
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.29 no.3
    • /
    • pp.132-139
    • /
    • 2019
  • EPS (expanded polystyrene) is one of the most used building materials for insulation that is favored by its excellent heat insulation, economical efficiency and lightweight characteristics. However, EPS is vulnerable to the fire and producing large amount of toxic gases in case of fire. Therefore, ultra-lightweight geopolymer which can replace EPS is fabricated by using IGCC (integrated gasification combined cycle) fused slag and Si sludge as raw materials and the possibility of replacement on ultra-lightweight geopolymer for EPS as an insulation building material was evaluated in this study. Ultra-lightweight geopolymer can be fabricated with the pulverized IGCC fused slag having low carbon content and density, compressive strength, thermal conductivity were $0.064g/cm^3$, 0.04 MPa, and 0.072 W/mK, respectively. The thermal conductivity of ultra-lightweight geopolymer is 1.5~2.0 times higher than that of EPS suggested in the KS M 3808; however, the thermal conductivity value of geopolymer is meaningful and competitive to that of EPS in the market. Therefore, ultralightweight geopolymer can be applicable to the building material for thermal insulation purpose and have an enough possibility to replace EPS in the future because it is not only much safer than EPS in case of fire but also it can be fabricate by using waste materials from the industry.