• Title/Summary/Keyword: 연성 능력

Search Result 338, Processing Time 0.025 seconds

Structural Performance Evaluation of Hollow Reinforced Concrete Half Slabs (철근콘크리트 중공 하프슬래브의 구조성능평가)

  • Hwang, Hyun-Bok;Kim, Sang-Woo;Hwang, Hyun-Sik;Lee, Ki-Jang;Lee, Jung-Yoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.45-48
    • /
    • 2008
  • This study is for proposing the shape of hollow and evaluating the structural performance of hollow reinforced concrete (RC) half slabs. The two-phase experimental works were carried out, and styrofoam was used for reduction of dead load and vibration. From the Phase I test result, the shape and spacing of the hollow were determined to obtain the high deduction ratio of the concrete and the desirable failure mode of the hollow RC half slabs. In the Phase II test, two slab specimens were tested in flexure to evaluate the flexural capacity of the hollow RC half slabs with the proposed hollow shape. In the result of the test, all the specimens having the proposed hollow shape showed sufficient flexural capacity.

  • PDF

Experimental Investigation of The Lateral Retrofitting Effect of FRP Sheet and Buckling-restrained Braces for Beam-Column Joints (FRP Sheet와 비좌굴 가새를 적용한 보-기둥 접합부의 횡방향 보강효과에 관한 실험적 연구)

  • Byon, Eun-Hyuk;Kim, Min-Sook;Lee, Young-Hak;Kim, Hee-Cheul
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.49-56
    • /
    • 2011
  • The strengthening effect of CFRP sheet and AFRP sheet with buckling-restrained brace for Beam-Column joints under constant axial and cyclic lateral loading is evaluated experimentally in this paper. Six test specimens were constructed. The main test parameters included the FRP Sheet and Buckling-restrained braces. The results of the tests were analyzed by focusing on their mode of failure, maximum load, ductility indexes, and energy dissipation capacity. Test results indicated that CFRP Sheet with the buckling-restrained brace system significantly increased the strength and stiffness of the specimen and that it was the most adequate retrofitting method.

Experimental Investigation of Seepage Properties on Weathered Residual Soils (풍화토의 침투 특성에 대한 실험적 고찰)

  • 권형민;김창엽;박영호;정충기;김명모
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.1
    • /
    • pp.75-82
    • /
    • 2004
  • To evaluate the characteristics of permeability in weathered residual soil, flexible wall permeameter tests are performed using undisturbed samples. The Influence of hydraulic gradient and confining pressure on the permeability of weathered residual soil is analyzed. To compare the characteristics of permeability between weathered soil and sand, similar tests are performed using Jumoonjin sand. Also, piping model tests are performed to investigate the piping resistance of weathered residual soil. As a result, weathered residual soil shows very dependable permeability on hydraulic gradient and very large resisting ability against piping compared with sand.

A Study on the Strengthening Effect of Reinforced Conctete BeamsFlexural Strengthening after Pre-loading (선가력 후 휨 보강한 RC보의 보강 효과에 관한 연구)

  • Kim, Jeong-Sup;Sin, Yong-Seok;Jo, Cheol-Hee;Kim, Kyoug-Ok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.6
    • /
    • pp.183-190
    • /
    • 2006
  • From the result of this research above, it may be summed up as follows. As a summary of results from each experiment, as the test body reinforced with the carbon rods was embedded inside the concrete section and made it possible uniform movement, this study has shown that it had excellent characteristics in improving the flexural strength and ductility. Also, it was considered as the carbon-steel sheet composite plate was to exert the strength more if it would complement the adherence with the concrete.

Nonlinear Analysis of Internally Confined Hollow CFT Columns (내부 구속 중공 CFT 기둥의 비선형 해석)

  • Han, Taek-Hee;Won, Deok-Hee;Kang, Young-Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.4
    • /
    • pp.439-454
    • /
    • 2011
  • A nonlinear analysis model for internally confined hollow concrete-filled tube (ICH CFT) columns was suggested and was verified by the test results obtained by the previous researchers. The suggested model considered the confining effect and nonlinearity of concrete. The verified results showed that the suggested model was reasonable and reliable for predicting the behavior of an ICH CFT column. Additionally, a simple parametric study was carried out. The strength of concrete, the hollow ratio of a column, and the thickness of an inner tube were selected as parameters affecting the behavior of an ICH CFT column. The analysis results showed that the concrete strength and the thickness of the inner tube affect the axial strength and moment capacity of the column while the hollow ratio affects only its axial strength.

Development of Improved PC Stair Connections Using U-Rods (U형 강봉을 사용한 PC 계단 접합부 개발)

  • Chang, Kug-Kwan;Seo, Dae-Won;Chun, Young-Soo
    • Land and Housing Review
    • /
    • v.2 no.4
    • /
    • pp.509-516
    • /
    • 2011
  • Compared with the traditional RC system, precast stairs can save construction time, reduce the cost of concrete casting, etc. This paper focuses on an investigation of improved continuous longitudinal joint details for PC stair systems. The performance of the precast concrete stair connections subjected to displacement control cyclic loading is compared with that of the monolithic connection. The developed connection is composed of U-rods and clamp joint metals. This paper proposes precast stair connection with improved structural performance and experimentally evaluates the structural performance of the proposed joints in terms of maximum load, displacement ductiliy, strain, crack and failure modes.

Flexural Strengthening Effect on R.C Beam with Structural Damage (구조적 손상을 입은 R.C보의 휨보강 효과)

  • Kim, Sung-Yong;Han, Duck-Jeon;Shin, Chang-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.1
    • /
    • pp.147-156
    • /
    • 2004
  • The Rehabilitation and repair of structurally deteriorated, reinforced concrete structures will be highly demanded in the near future. The purpose of this study is to investigate whether damaged beams that crack and deflection are developed by bending moment are restored to the former state. In conclusion, when specimens strengthened with Steel Plate, CFS(Carbon Fiber Sheet) and CFRP-Grid(Carbon Fiber Reinforced Plastic-Grid) are compared with standard specimen, flexural capacity is increased and ductility and energy absorbtion capacity are similar with undamaged specimen. Therefore Steel Plate, CFS(Carbon Fiber Sheet) and CFRP-Grid (Carbon Fiber Reinforced Plastic-Grid) have highly efficiency as material of flexural strengthening.

Seismic Capacity Strengthened by GFS of Masonry Buildings with Earthquake Damage (지진피해를 입은 조적조 건축물의 유리섬유보강에 따른 내진성능)

  • Kwon, Ki-Hyuk;Choi, Sung-Mo;Lee, Soo-Cheul;Cho, Sang-Min
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.1
    • /
    • pp.231-237
    • /
    • 2004
  • Most of the masonry buildings have many structural defects under an earthquake load due to the small tensile force and ductility. In the foreign countries there are many the reinforcing methods of masonry buildings, but the glass fiber sheet reinforcements must be used due to various conditions in Korea. The purpose of this paper is to estimate the seismic capacity of masonry buildings damaged by earthquake and reinforced by Glass Fiber Sheet. On the basis of test results, the maximum base shear force and deformation of the masonry building with GFS were remarkably increased. From the comparison by existing strength equations and test data, the new strength equation of reinforced masonry buildings with GFS was developed.

Cyclic Seismic Performance of Reduced Beam Section Steel Moment Connections: Effects of Panel Zone Strength and Beam Web Connection (패널존 강도 및 보 웨브 접합방식이 RBS 철골 모멘트접합부의 내진거동에 미치는 영향)

  • Lee, Cheol-Ho;Jeong, Sang-Woo;Kim, Jin-Ho
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.337-348
    • /
    • 2003
  • 본 연구는 8개의 RBS (reduced beam section) 내진 철골모멘트접합부의 실물대 실험결과를 요약한 것이다. 본 실험의 주요변수는 보 웨브 접합법 및 패널존 강도를 택하였다. 균형 패널존 시험체는 접합부의 내진성능을 감소시키지 않으면서, 보와 패널존이 함께 균형적으로 지진에너지를 소산시키도록 설계하여 값비싼 패널존보강판(doubler plates)의 수요를 줄이고자 시도한 것이다. 보 웨브를 용접한 시험체는 모두 특별 연성모멘트골조에서 요구되는 접합부 회전능력을 충분히 발휘하였다. 반면 보 웨브를 볼트접합한 시험체는 조기에 스캘럽을 가로지르는 취성파단이 발생하는 열등한 성능을 보였다. 보 그루브 용접부 자체의 취성파괴가 본 연구에서와 같이 양질의 용접에 의해 방지되면, 스켈럽 부근의 취성파단이 다음에 해결해야 할 문제로 대두되는 경향을 보인다. 보 웨브를 볼팅한 경우에 접합부 취성파단의 빈도가 월등히 높은 이유를 실험 및 해석결과를 토대로 제시하였다 측정된 변형도 데이터에 의할 때, 접합부의 전단력 전달메카니즘은 흔히 가정하는 고전 휨이론에 의한 예측과 전혀 다르다. 이는 전통적 보 웨브 설계법을 재검토할 필요가 있음을 시사하는 것이다. 아울러, 본 연구의 제한된 실험자료 및 접합부에서 요구되는 바람직한 거동기준을 근거로 균형 패널존의 강도범위에 대한 예비적 추정치를 제시하였다.

  • PDF

A study on the roughness coefficient of NPE-coated corrugated steel pipes and inner flat steel pipes (NPE 피복 파형강관과 내부평활 파형강관의 조도계수 검토)

  • Jeong-Myeong Lee;Yoon-Hwan Jeong;Jin-A Jegal;Seung-Ho Hong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.311-311
    • /
    • 2023
  • 파형강관은 아연도금강판을 물결모양으로 성형하여 나선형으로 조관한 연성관으로 콘크리트 흄관을 대체하여 각종 토목공사의 우수 및 하수관으로 주로 사용되고 있다. 파형강관은 강판에 물결 형상을 성형하여 내하력을 부여하였기 때문에 높은 강도를 지니고 있고, 경량이고 유연성이 있어 기초공사가 쉽고 현장에서의 운반 및 보관이 용이하여 그 활용이 점차 확대되고 있다. 이러한 파형강관의 내/외부에 기능성 고분자 복합 Polymer(다중필름)을 코팅하여 일반 파형강관 대비 더 높은 내식성 및 내마모성을 구현한 제품을 NPE 피복 파형강관이라 하며, 내부에 평판을 2중으로 결합하여 일반 파형강관 대비 통수능력을 개선한 파형강관을 내부평활 파형강관이라고 한다. 최근 파형강관의 활용이 점차 확대되고 있음에도 불구하고, 파형강관에 국한된 수리역학적 특성에 관한 연구는 미흡한 실정이며, 그마저도 주로 만관 혹은 만관에 가까운 상태에서의 흐름만이 고려되어 왔다. 하지만 대구경의 파형 강관이 우수 배관 및 하수 처리를 위하여 설치될 경우 개수로 흐름이 발생하게 된다. 이에, NPE 피복 파형강관과 내부평활 파형강관 내에서의 개수로 흐름을 다양한 유량 및 수심 변화를 통하여 생성하였으며, 각각의 수리학적 조건에서 통수능을 결정하는데 중요한 상수인 조도계수를 수리 실험을 실시하여 결정하였다. 이는 현재 국내에서 생산되고 있는 NPE 피복 파형강관과 내부 평활강관의 활용에 있어서 국제 경쟁력을 높이는데 큰 도움이 될 것이라 사료된다.

  • PDF