• Title/Summary/Keyword: 역계단

Search Result 64, Processing Time 0.027 seconds

Influence on the Ground Reaction Force Parameters According to Wearing Positions of Backpacks During Stair Ascending and Descending (계단 오르기와 내리기 시 가방착용 위치가 지면반력 파라미터에 미치는 영향)

  • Hyun, Seung-Hyun;Ryew, Che-Cheong
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.1
    • /
    • pp.85-94
    • /
    • 2015
  • Purpose : The purpose of this study was to investigate the influence on the ground reaction force parameters according to wearing positions of backpack for during stair ascending and descending. Methods : Participants selected as subject were consisted of young female(n=10) and performed stairs walks(ascending and descending) with 2 types of wearing position(front of trunk[FT], rear of trunk[RT]). Passive(Fz 1) and active(Fz 2) forces of the vertical GRF were determined from time function and frequency domain. Also shear forces(Fx, Fy 1, Fy 2), dynamic postural stability index(MLSI, APSI, VSI, DPSI), loading rate and center of pressure (${\Delta}COPx$, ${\Delta}COPy$, COP area) were calculated from time function and frequency domain. Results : Fx, Fy 1, Fy 2, and Fz 1 in GRF didn't show significant differences statistically according to the wearing positions of backpack(p>.05), but stair descending showed higher forces than that of stair ascending. Particularly, Fz 2 of stair ascending showed higher forces than that of stair descending(p<.001), RT types showed higher than that of FT types(p<.05). MLSI, APSI, VSI, and DPSI of stair descending showed the increased stability index than that of stair ascending(p<.05), MLSI of RT types showed the decreased stability index than that of FT types(p<.05). Loading rate didn't show significant differences statistically according to the wearing positions of backpack(p>.05), but stair descending showed higher loading rate than that of stair ascending(p<.001). Also, ${\Delta}COPx$ in stair descending showed the increased movement than that of stair ascending(p<.05). Conclusions : A backpack of 10 kg(10 kg(ratio of body weights $17.61{\pm}1.17%$) showed significantly change GRF parameters according to wearing positions during stair ascending and descending. If possible, we suggest that the dynamic stability, in case of stairs walking with a smaller weights can be further improved.

Ka-band Feed Horn Antenna Including Circular-polarizer and Straight Type Mode Converter (Ka-대역 원형편파기와 직선구조 모드변환기를 포함한 급전 혼 안테나)

  • Jung, Young-Bae;Eom, Soon-Young;Jeon, Soon-Ik;Kim, Chang-Joo;Park, Seong-Ook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.06a
    • /
    • pp.569-571
    • /
    • 2007
  • In this paper, hem antenna composed of rectangular hern, circular polarizer and straight-type mode convertor is designed and fabricated. The circular polarizer is designed as a dielectric type having broadband characteristic, and it is inserted into the rectangular hem with $45^{\circ}$ inclination. The straight-type mode convertor has a terrace-type structure in order to convert the TEM mode signal of coaxial cable to the TE mode of rectangular waveguide, and this structure minimizes conversion loss. Fabricated hem antenna operates at $30.085\sim30.885GHz$ and has VSWR < 1.5, Axial ratio < 1.0dB and antenna gain of $6.7\sim7.0dBi$ in the band.

  • PDF

Analysis of Improvement Measures of Vertical Moving Facilities at Subway Stations for Elderly Users based on a Data Envelopment Analysis (자료포락분석 기반의 고령자를 위한 지하철 역사 수직이동시설의 개선방안 분석)

  • Lee, Eun Hak;Kho, Seoung-Young;Kim, Dong-Kyu
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.16 no.5
    • /
    • pp.60-71
    • /
    • 2017
  • The purpose of this study is to evaluate vertical moving facilities at subway stations for the elderly users and to analyze their improvement measures. To evaluate vertical moving facilities of the top 31 subway stations with the most trips in Seoul, a data envelopment analysis (DEA) is employed. The input variables for the DEA include the number and percentage of elderly users, which are calculated using smart card data. the output variables consist of the number of elevators and escalators per 100 steps. The results show that the average score of 31 subway stations is 0.62 and four stations, i.e., Jamsil, Gasan Complex, Konkuk University, and Dongmyo, have the highest score. These four subway stations are set as benchmarking groups for the other stations with the lower score. Based on the comparison with the benchmarking groups, the improvement measures for vertical moving facilities of each station are suggested and discussed.

Feasibility Study of Forward-Looking Imaging Radar Applicable to an Unmanned Ground Vehicle (무인 차량 탑재형 전방 관측 영상 레이다 가능성 연구)

  • Sun, Sun-Gu;Cho, Byung-Lae;Park, Gyu-Churl;Nam, Sang-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.11
    • /
    • pp.1285-1294
    • /
    • 2010
  • This study describes the design and verification of short range UWB(Ultra Wideband) imaging radar that is able to display high resolution radar image for front area of a UGV(Unmanned Ground Vehicle). This radar can help a UGV to navigate autonomously as it detects and avoids obstacles through foliage. We describe the relationship between bandwidth of transmitting signal and range resolution. A vivaldi antenna is designed and it's radiation pattern and reflection are measured. It is easy to make array antenna because of small size and thin shape. Aperture size of receiving array antenna is determined by azimuth resolution of radar image. The relation of interval of receiving antenna array, image resolution and aliasing of target on a radar image is analyzed. A vector network analyzer is used to obtain the reflected signal and corner reflectors as targets are positioned at grass field. Applicability of the proposed radar to UGV is proved by analysis of image resolution and penetrating capability for grass in the experiment.

The Effects of 12 Week Balance Ability Improvement Exercise to the Changes of Selected Joint Angles and Ground Reaction Forces during Down Staircase Walking (노인대상 12주간 균형능력 향상 운동이 계단 내리기 보행 시 주요 관절각 및 지면반력 변화에 미치는 영향)

  • Park, Yang-Sun;Kim, Eui-Hwan;Kim, Tae-Whan;Lee, Yong-Sik;Lim, Young-Tae
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.3
    • /
    • pp.267-275
    • /
    • 2010
  • The purpose of this study was to investigate the effects of balance ability improvement exercise program which applied to the elderly people for increasing balance, stability and range of motion. Ten elderly people and ten university students were recruited as the subjects. Kinematic data were collected by seven real-time infrared cameras while subjects walk stair descent as a pre-test. Korean folk dance exercise program was applied to the elderly for 12 weeks. Same experiment on stair descent walk was performed as post-test. Results indicated that CM movement and selected joint angle patterns of elderly group after treatment changed to the similar patterns of young group. However, ankle joint angle and vertical GRF of elderly group after treatment also increased compared to those of the elderly group before treatment. This might be explained by the fact that elderly used a different walking strategy which maximize support base for increasing stability. Overall, these results indicated that the exercise treatment may affect to adapt and improve the gait pattern of stair descent of elderly people.

Analysis of Acoustic Propagation using Spectral Parabolic Equation Method (스펙트럴 포물선 방정식 법을 이용한 수중음파 전달해석)

  • Kim, Kook-Hyun;Seong, Woo-Jae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.72-78
    • /
    • 1996
  • This thesis deals with a method to solve a two-and-one-half-dimensional ($2\frac12$ D) problem, which means that the ocean environment is two-dimensional whereas the source is fully three-dimensionally propagating, including three-dimensional refraction phenomena and three-dimensional back-scattering, using two-dimensional two-way parabolic equation method combined with Fourier synthesis. Two dimensional two-way parabolic equation method uses Galerkin's method for depth and Crank-Nicolson method and alternating direction for range and provides a solution available to range-dependent problem with wave-field back-scattered from discontinuous interface. Since wavenumber, k, is the function of depth and vertical or horizontal range, we can reduce a dimension of three-dimensional Helmholtz equation by Fourier transforming in the range direction. Thus transformed two-dimensional Helmholtz equation is solved through two-way parabolic equation method. Finally, we can have the $2\frac12$ D solution by inverse Fourier transformation of the spectral solution gained from in the last step. Numerical simulation has been carried out for a canonical ocean environment with stair-step bottom in order to test its accuracy using the present analysis. With this spectral parabolic equation method, we have examined three-dimensional acoustic propagation properties in a specified site in the Korean Straits.

  • PDF

A Study on the Evaluation Method of Level of Service in Transfer Walking Facilities (환승 보행시설의 서비스수준 평가방법에 관한 연구)

  • Yun, Tae-Gwan;Lee, Yeong-In
    • Journal of Korean Society of Transportation
    • /
    • v.28 no.1
    • /
    • pp.143-156
    • /
    • 2010
  • The walking is very important because of its environment friendly and low accident rate, and transferring is also important as increasing public transportation uses. Facilities for transferring such as transfer path in Sadang station and internal stairways in Sindorim station are the object of this paper. Using preexistence methodology for Level of Service is not appropriate to transferring facilities because they are occurred only when the train arrive that station. To solve this problem, this paper uses queuing theory and utilization factor. In result, we can get Level of Service which can simulate real situation of the facilities by using new methodology which introduce by this paper. Also it reveals that preexistence methodology cannot simulate real phenomenon in transferring center.

The Study on Fire Phenomena in The Deeply Underground Subway Station (대심도 지하역사에서의 화재현상 연구)

  • Jang, Yong-Jun;Kim, Hag-Beom;Lee, Chang-Hyun;Jung, Woo-Sung
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1773-1780
    • /
    • 2008
  • When the fire occur in the deeply underground subway station, the difficulties of passenger evacuation are expected because of many stairs to the exit. In this study, SOONGSIL-University station (7 line, 47m depth) is the one of the deepest subway stations of the each line in the Seoul metro. The numerical computational-simulation was performed for the fire driven flow in the subway station. Hot and smoke flow was analyzed from the simulation results. The proper plan of evacuation against fire was considered through the results. The fire driven flow was simulated using FDS code in which LES method was applied. The Heat Release Rate was 10MW and the ultrafast model was applied for the growing model of the fire source. The proper mesh size was determined from the characteristic length of fire size. The parallel computational method was employed to compute the flow and heat eqn's in the meshes, which are about 10,000,000, with 6cpu of the linux clustering machine.

  • PDF

Study on the High Yield of Kudzu (Pueraria thunbergiana Benthan) as Covering Crops of Reclaimed Soil (개간지(開墾地) 피복작물(被覆作物)로서의 "칡"증산(增産)을 위(爲)한 기초연구(基礎硏究))

  • Jo, Jae Seong;Kim, Young Rae;Kim, Choong Soo
    • Korean Journal of Agricultural Science
    • /
    • v.2 no.1
    • /
    • pp.143-149
    • /
    • 1975
  • To obtain some basic informations on the breeding of Kudzu, 42 individuals were selected and their morphological characteristics were investigated and analyzed. The shape of leaves was classified as 4 types and area of leaves into 5 steps. Internode length was distributed between 13 cm and 37 cm. Significant correlations were recognized between petiole and leaf area, between internode length and internode diameter and between internods diameter and leaf area.

  • PDF

Transient Voltage Measuring System Using the Capacitive Electric Field Sensor (용량성 전장센서를 이용한 과도전압측정계)

  • Lee, Bok-Hee;Kil, Gyung-Suk;Ju, Mun-No;Lee, Sung-Heon
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.9-16
    • /
    • 1996
  • This paper deals with the capacitive voltage divider which can measure a transient voltages generated by operating a high voltage impulse generator. The transient voltage measuring system using the capacitive electric field sensor consists of the planar-type electric field sensor having a fast response characteristic and the wide-bandwidth voltage follower, and the input impedance of which is extremely high, about $10^{12}{\Omega}$. In order to analyze the response characteristics to a step input, the newly developed calibration method is proposed, and the error of voltage dividing ratio associated with set-up condition is investigated. Also the optimal set-up condition that is to be maintained within the range of 0.5 % is taken. From the calibration experiment, the frequency bandwidth of the transient voltage measuring system whose response time to a step input is about 15.8 ns, is from 6.37 Hz to 27.3 MHz. Therefore it is possible to measure the commercial frequency voltages as well as the transient over voltages without signal distortions.

  • PDF