• Title/Summary/Keyword: 에어 가이드

Search Result 14, Processing Time 0.023 seconds

Design of Pad Type Air-Bearing for LCD Inspection (LCD 검사 장비용 패드형 에어베어링 설계)

  • Oh, Hyun-Seong;Lee, Sang-Min;Park, Jeong-Woo;Kim, Yong-Woo;Lee, Deug-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.9
    • /
    • pp.103-109
    • /
    • 2007
  • LCD (Liquid Crystal Display) is widely used electronic product. It needs too many processes such as PECVD (Plasma Enhanced Vapor Deposition), Sputtering, Photo-lithography, Dry etch. Each process is important but inspection process is more important because most companies emphasis on the six sigma. Recently, LCD inspection system is composed with inlet, inspector, outlet air pads. LCD is inspected on air pad which is shooting air from air hole. This paper studies on pad design of air bearing for LCD inspection to minimize LCD fluctuation. This design is able to reduce fluctuation and then satisfies CCD inspectional range. Also inspection pad needs to adequate stable area.

에어베어링을 이용한 회전형 스테이지 설계에 관한 연구

  • Yun, Deok-Won;Kim, Jin-Ho;Sin, Dong-Ik;Lee, Yeon-Deok;Jeong, Beol-Gyo;Han, Chang-Su
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2007.06a
    • /
    • pp.125-127
    • /
    • 2007
  • 에어 베어링은 높은 강성과 낮은 마찰력과 같은 장점들로 인하여 높은 정밀도를 요구하는 반도체나 디스플레이 장비의 선형 스테이지에 주로 사용 되어지고 있다. 하지만 현재까지 높은 정밀도를 요구하는 회전형 스테이지에는 아직까지 크로스 롤러링을 이용하여 가이드를 하고 있다. 본 논문에서는 높은 정밀도를 갖는 회전 스테이지의 설계를 위하여 구동 성능과 오차요소에 대한 성능에 대해 설계 목표를 제시 하였고 이러한 스테이지를 구현하기 위해 에어베어링을 적용한 회전형 스테이지를 설계하였다.

  • PDF

A brief introduction to nozzle design in air jet loom (에어제트 직기의 노즐 설계기술)

  • 송동주;구본감
    • Journal of the KSME
    • /
    • v.35 no.1
    • /
    • pp.36-45
    • /
    • 1995
  • 주노즐내의 공기제트의 효율을 높이기 위해, 주노즐 제트 속도는 높을수록 높은 마찰력을 초래 하여 위사의 속도를 증가시킨다. 가속관의 길이가 증가하면 노즐출구에서의 공기의 속도와 난 류가 감소하며; 가속관의 직경이 증가할 때에는 공기속도가 감소하며 난류는 증가한다. 탱크압력, 가속관의 길이 등 유동조건에 따라 유동은 니들 끝과 가속관 출구에서 이중 초크(M=1)가 발 생할 수 있다. 에어가이드 직경과 노즐직경의 그 비율이 클수록 제트에 의한 유동의 비말동 반(entrainment)이 크게 된다. 실제 노즐직기내의 유동은 위사를 동반한 유동이므로 위와 같은 정성적인 설명에 위사의 물성치에 따른 고려를 반드시 하여야만 한다. 현장에서의 노즐설계는 노즐형상 자체의 영향은 물론 각종 위사의 물성치에 맞는 압축공기 압력 최적조건이 무엇인가를 찾는 일도 매우 중요하다.

  • PDF

An efficient power supply of monitoring systems for power transmission lines (송전선 감지 체계를 위한 효율적인 전력 공급 장치)

  • Lim, Cheon-Yong;Moon, Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.110-111
    • /
    • 2017
  • 송전선 감지 체계를 위한 효율적인 전력 공급 장치를 제안한다. 이전에는 무시하였던 2차측 부하에 의한 영향을 고려하여 에어 갭이 없는 코어를 사용할 수 있음을 확인하였고 이를 통해 훨씬 큰 전력을 추출하였다. 분석을 통해 새로운 설계 가이드 또한 제시하였다. 실험을 통해 제안한 방식의 성능을 검증하였다.

  • PDF

Development of a New Air Cooling System Utilizing the Stirling Engine for Preventing Solar Cell from Overheating (태양광 모듈의 과열 방지용 공랭형 스털링기관 냉각 시스템 개발)

  • Kim, Hyoungeun;Park, Chanwoo;Chu, Jinkyung;Keum, Dongyeop;Park, Silro;Kim, Jeongmin;Kim, Daejin
    • Transactions of the KSME C: Technology and Education
    • /
    • v.2 no.1
    • /
    • pp.57-63
    • /
    • 2014
  • In this paper new air-cooling system utilizing Stirling engine was proposed for improving efficiency in solar photovoltaic power generation. The solar cell plate was equipped with semi-circular channel for air flow on the backside. Beta-type Stirling engine was installed on the plate and its flywheel was connected to a motor fan by a transmission belt. A forced convective air flow for heat radiation was generated by the operation of the self-starting Stirling engine. The performance tests for power generation of solar cell with or without the proposed air-cooling system were conducted under halogen lamp. From the experimental results, it was found that decline in output voltage of the solar cell with proposed cooling system was 25% less than that of the solar cell without cooling system.

Three-Dimensional Numerical Analysis on Recirculation Generated by Obstacles Around a Cooling Tower (냉각탑 주위 장애물에 의한 재순환 현상에 관한 3차원 수치해석)

  • Choi, Young-Ki
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.4
    • /
    • pp.225-234
    • /
    • 2009
  • The present study has been preformed to investigate the effect of obstacles around a cooling tower with air-guide to prevent recirculation. The external region as well as the cooling tower are included in the computational domain to analyze the flow phenomena around a cooling tower accurately. Three-dimensional analysis is performed using the finite volume method with non-orthogonal and unstructured grid system. The standard turbulence model is used to consider the turbulence effect. In order to investigate the recirculation phenomena, flow and temperature fields are calculated with the distance between cooling tower and obstacle, the allocated geometrical type and the air-guide. The moisture fraction rates decrease with increment of the distance between cooling tower and obstacle. The effect of air-guide to reduce the mean recirculation rate is obviously observed.

Analysis of Temperature Rise on the Air-Guide's Position of Wind Power Generator (풍력발전기 Air Guide 위치별 온도상승 해석)

  • Han, Chang-Woo;Kim, Hyun-Jae;Kweon, Ki-Yeoung;Lee, Hahk-Sung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.282-285
    • /
    • 2008
  • In this paper, the numerical analysis of the model without air-guide was carried out in wind power generator. From numerical results, the temperature rise was not satisfied for the class F insulation and the non-uniformity of temperature distribution was a wide difference in heating elements. To improve these problems, the air-guide was installed in front of the coil head of non-drive end(NDE). The short distance between coil head and air-guide was more effective than long distance in cooling performance. Compared to that of the preliminary design, it was found that the cooling performance of the modification design was improved about 12%.

  • PDF

Numerical Analysis on Recirculation Generated by Obstacles around a Cooling Tower (냉각탑 주위의 장애물에 의한 재순환 현상에 관한 수치해석)

  • Lee Jung-Hee;Choi Young-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.7
    • /
    • pp.578-586
    • /
    • 2006
  • The present study has been conducted to examine the effect of obstacles around a cooling tower and an air-guide to prevent recirculation. In order to analyze the interaction between external flow and cooling tower exit flow, the external region as well as the cooling, tower are included in computational domain. Two dimensional analysis is performed using the finite volume method with non-orthogonal and unstructured grid system. The standard ${\kappa}-{\varepsilon}$ turbulence model is used. To investigate the recirculation phenomena, flow and temperature fields are calculated with three approaches such as, the distance between cooling tower and obstacle, the allocated geometrical type, and the effect of height of obstacle. In addition, the air-guide is considered in the current computation. The mean recirculation rate increases with the height of obstacle. The effect of air-guide to reduce the mean recirculation rate is obviously observed.

Development of New Measurement Device for the Coefficient of Kinetic Friction by Using Side Air-Guide Track (측면 에어 가이드 트랙을 이용한 새로운 운동마찰계수 측정 장치의 개발)

  • Nam, Hyoung Joo
    • Journal of Engineering Education Research
    • /
    • v.21 no.3
    • /
    • pp.12-19
    • /
    • 2018
  • In this study, a new experimental device was developed for measurement of the coefficient of kinetic friction using a photo gate timer system which have advantages of easy and accurate detection of motion. This device, consisting of a side air-guide track and a side friction-free glider, forces a friction sample to move in a straight line without producing unnecessary friction. The new device is compared to two conventional measuring methods of friction for four different friction samples: one is using a camera system and the other is using a force sensor. It is demonstrated that the developed friction device in this study is easier to operate and produces the most accurate and the least deviating results among them. On the basis of these results, we propose that friction experiment using the new friction device is included in general physics experiment, so that engineering students should have a chance to get correct understanding of classical mechanics including friction phenomenon.

Play Behaviour and Environment Using User Research (Focused on Air-bounce Space in Theme Museum) (사용자 조사법을 이용한 어린이 놀이행태 및 놀이환경 분석 (테마박물관의 실내 에어바운스 공간을 대상으로))

  • Song, Mi;Yun, Hee Jeong
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.1
    • /
    • pp.274-284
    • /
    • 2016
  • The purpose of this study is to analyze the play behaviour and play environment of children at the Air-bounce space in the theme museum, using user observation and interviewing user behaviour, main methods of user research. Study area is Animation theme museum in Chuncheon City, Kangwon Province, Republic of Korea. Main results show that physical, emotional, cognitive, and social behaviour of playing children in the study area are observed, and this study draws the planning and design related implications of play space such as carrying capacity, waiting room and safety guard and so on. The results of this study can be used in the planning and design process of children's play environment as important guidelines.