• 제목/요약/키워드: 에어로졸 입자

검색결과 446건 처리시간 0.026초

서울지역 교통수단별 이동시간과 호흡량을 고려한 미세먼지 흡입량 추정에 관한 연구 (Estimation of PM10 and PM2.5 inhalation dose by travel time and respiratory volume in common transport microenvironments in Seoul, Korea)

  • 이용일;정원석;황도연;김태성;박덕신
    • 한국입자에어로졸학회지
    • /
    • 제14권4호
    • /
    • pp.97-105
    • /
    • 2018
  • Recently, people's interest in particulate matter (PM) has been increasing, due to its hazardous health effects. The purpose of this study was to investigate the concentrations and as well as the inhaled weight of PM, correlated with person's heart rate in subway, bus, vehicle and bicycle in the major public transportation (Sadang - Jamsil and Nowon - Dongdaemun) in Seoul. The concentration of $PM_{10}$ and $PM_{2.5}$ were measured from each of transportation means and calculated the average concentrations which were 87.2 and $57.8{\mu}g/m^3$ for subway, 62.8 and $42.5{\mu}g/m^3$ for vehicle, 61.5 and $36.8{\mu}g/m^3$ for bus and 53.0 and $29.4{\mu}g/m^3$ for bicycle in $PM_{10}$ and $PM_{2.5}$ respectively. Inhalation dose for $PM_{10}$ and $PM_{2.5}$ were estimated at 248.1 and $139.4{\mu}g$ for bicycle, 56.7 and $39.3{\mu}g$ for vehicle, 49.4 and $29.9{\mu}g$ for bus and 44.3 and $29.1{\mu}g$ for subway, respectively. Even though subway had the highest concentration, the highest inhalation dose was the bicycle. It was due to the long travel time-exposure and breathing rate which leads to maximum of $PM_{10}$ 5.6 and $PM_{2.5}$ with 4.8 times inhalation dose comparing with other modes of transportation. With regards to future studies, the amount of inhalation in each transportation means should be considered in risk assessments of PM.

안면도에서의 초미세먼지 유기성분 주요 영향원 평가 (Estimation of the major sources for organic aerosols at the Anmyeon Island GAW station)

  • 한상희;이지이;이종식;허종배;정창훈;김은실;김용표
    • 한국입자에어로졸학회지
    • /
    • 제14권4호
    • /
    • pp.135-144
    • /
    • 2018
  • PMF 수용모델을 사용하여 안면도 측정소에서 2년간 측정한 초미세먼지의 유기성분의 주요 영향원을 파악하였다. 5개 또는 6개의 요인이 최적으로 나타났으며, 6개의 요인이 결과를 더 잘 해석하는 것으로 판단되었다. 이들 요인의 계절별 특성과 영향도 변화를 고려하여 결정한 주요 오염원은 이차유기성분(10.3%), 연소(12.0%), 자연적 생물성 기원(24.8%) 장거리이동식생소각(7.3%), 국지적 생체소각(26.4%), 장거리이동 오염원(19.2%)이다. 안면도 측정소는 배경지역의 특성인 자연적 생물성 기원, 이차유기성분과 장거리이동 오염원의 영향도가 크게 나타나면서도, 비도심의 특성인 국지적 식생소각과 연소 영향도 나타나고 있다. 이는 안면도 측정소에서는 인위적인 영향에 의한 유기성분 특성은 제한적임을 보여준다.

고전압 전극 두께와 집진판 간격에 따른 전기집진기의 미세먼지 집진효율 및 오존발생 특성 (Characteristics of particulate matter collection efficiency and ozone emission rate of an electrostatic precipitator by thickness of high-voltage electrode and distance of collection plates)

  • 이재인;우상희;김종범;이승복;배귀남
    • 한국입자에어로졸학회지
    • /
    • 제14권4호
    • /
    • pp.171-180
    • /
    • 2018
  • To optimize the shape of the electrostatic precipitator for the removal of particulate matter in subway environments, the wind-tunnel experiments were carried out to characterize collection efficiency and ozone emission rate. As a standardized parameter, power consumption divided by the square of flow velocity, was increased, the $PM_{10}$ collection efficiency increased. If the standardized parameter is higher than 1.0 due to high power consumption or low flow velocity, increase in thickness of electrodes from 1 to 2 mm, or increase in distance of collection plates from 5 to 10 cm did not change the $PM_{10}$ collection efficiency much. Increase in thickness of high-voltage electrodes, however, can cause decrease in $PM_{10}$ collection efficiency by 28% for low power consumption and high flow velocity. The ozone emission rate decreased as distance of collection plates became wider, because the ozone emission rate per unit channel was constant, and the number of collection channels decreased as the distance of collection plates increased. When the distance of collection plates was narrow, the ozone emission rate increased with the increase of the thickness of electrodes, but the difference was negligible when the distance of collection plates was wide. It was found that the electrostatic precipitator having a thin high-voltage electrodes and a narrow distance of collection plates is advantageous. However, to increase the thickness of high-voltage electrodes, or to increase the distance of collection plates is needed, it is necessary to increase the applied voltage or reduce the flow rate to compensate reduction of the collection efficiency.

서울 초등학교 교실의 PM2.5 및 PM10 제거를 위한 학교용 공기청정기 실증 (Field tests of indoor air cleaners for removal of PM2.5 and PM10 in elementary school's classrooms in Seoul, Korea)

  • 한방우;홍기정;신동호;김학준;김용진;김상복;김상우;황청하;노광철
    • 한국입자에어로졸학회지
    • /
    • 제15권2호
    • /
    • pp.79-90
    • /
    • 2019
  • It is important to control fine particles in children care centers, elementary schools, elderly care facilities and so on where vulnerable children and the aged stay during most of their time. This study has investigated $PM_{2.5}$ and $PM_{10}$ concentrations in two classrooms equipped with an air cleaner and two air cleaners, respectively and they were compared to those in a classroom without an air cleaner as well as those outdoors. Eight air cleaners which have various clean air delivery rates (CADRs) between 9.9 and $21.3m^3/min$ were tested in classrooms in two elementary schools in Seoul. Average $PM_{2.5}$ and $PM_{10}$ were $7.3{\pm}0.7$ and $45.5{\pm}4.1{\mu}g/m^3$ in classrooms equipped with an air cleaner and $4.2{\pm}0.6$ and $24.6{\pm}2.5{\mu}g/m^3$ in classrooms with two air cleaners, whereas they were $22.1{\pm}2.6$ and $109.1{\pm}9.6{\mu}g/m^3$ in classrooms without an air cleaner and $36.9{\pm}5.1$ and $74.1{\pm}10.6{\mu}g/m^3$ outdoors, respectively. $PM_{2.5}$ in classrooms could be reduced effectively by using an air cleaner or two air cleaners, because $PM_{2.5}$ was mainly infiltrated from outdoors, however $PM_{10}$ could not because $PM_{10}$ was mainly caused indoors by students' activities. Air cleaners were more effective for removal of $PM_{2.5}$ and $PM_{10}$ in classrooms with a high airtightness than those in classrooms with a relatively low one. Average $CO_2$ in classrooms was about 1500 to 2000 ppm for class hours dependent on the student number per a classroom, which was about 1.5 to 2 times higher than the standard, regardless of the use of air cleaner.

광주 지역에서 2018년 1월 측정한 초미세먼지의 오염 특성 (Pollution characteristics of PM2.5 observed during January 2018 in Gwangju)

  • 유근혜;박승식;정선아;조미라;장유운;임용재;김영성
    • 한국입자에어로졸학회지
    • /
    • 제15권3호
    • /
    • pp.91-104
    • /
    • 2019
  • In this study, hourly measurements of $PM_{2.5}$ and its major chemical constituents such as organic and elemental carbon (OC and EC), and ionic species were made between January 15 and February 10, 2018 at the air pollution intensive monitering station in Gwangju. In addition, 24-hr integrated $PM_{2.5}$ samples were collected at the same site and analyzed for OC, EC, water-soluble OC (WSOC), humic-like substance (HULIS), and ionic species. Over the whole study period, the organic aerosols (=$1.6{\times}OC$) and $NO_3{^-}$ concentrations contributed 26.6% and 21.0% to $PM_{2.5}$, respectively. OC and EC concentrations were mainly attributed to traffic emissions with some contribution from biomass burning emissions. Moreover, strong correlations of OC with WSOC, HULIS, and $NO_3{^-}$ suggest that some of the organic aerosols were likely formed through atmospheric oxidation processes of hydrocarbon compounds from traffic emissions. For the period between January 18 and 22 when $PM_{2.5}$ pollution episode occurred, concentrations of three secondary ionic species ($=SO{_4}^{2-}+NO_3{^-}+NH_4{^+}$) and organic matter contributed on average 50.8 and 20.1% of $PM_{2.5}$, respectively, with the highest contribution from $NO_3{^-}$. Synoptic charts, air mass backward trajectories, and local meteorological conditions supported that high $PM_{2.5}$ pollution was resulted from long-range transport of haze particles lingering over northeastern China, accumulation of local emissions, and local production of secondary aerosols. During the $PM_{2.5}$ pollution episode, enhanced $SO{_4}^{2-}$ was more due to the long-range transport of aerosol particles from China rather than local secondary production from $SO_2$. Increasing rate in $NO_3{^-}$ was substantially greater than $NO_2$ and $SO{_4}^{2-}$ increasing rates, suggesting that the increased concentration of $NO_3{^-}$ during the pollution episode was attributed to enhanced formation of local $NO_3{^-}$ through heterogenous reactions of $NO_2$, rather than impact by long-range transportation from China.

항공관측 결과를 활용한 당진시 대형사업장에서의 황산화물 배출량 평가 (Estimation of SO2 emissions in large point sources at Dangjin City using airborne measurements)

  • 김용표;김세웅;김종호;이태형
    • 한국입자에어로졸학회지
    • /
    • 제16권4호
    • /
    • pp.107-117
    • /
    • 2020
  • 충청남도 대형사업장에서의 대기오염물질 배출이 미세먼지 농도에 미치는 영향에 대한 논란이 많다. 2019년 봄과 가을에 항공관측을 수행하여 충청남도 대형사업장 상공에서 대기오염물질 농도를 측정하였고, 이를 바탕으로 황산화물(SO2) 배출량을 산정하였다(하향식 배출량). 이를 사업장에서 제시한 배출량 자료(상향식 배출량)와 비교한 결과, 항공관측에 바탕을 둔 배출량이 더 많았다. 항공관측에 바탕을 둔 배출량은 석탄화력발전소는 1502.1 kg/hr, 제철소는 2805.5 kg/hr였다. 이는 사업장에서 밝힌 2019년 연평균 배출량보다 각각 2.5배와 2.0배 큰 값이다. 이와 같은 차이가 나는 원인을 규명하기 위해서는 관측에 바탕을 둔 하향식 배출량과 활동도에 바탕을 둔 기존의 상향식 배출량을 산정함에 있어서 보다 면밀한 검토와 개선이 필요하다. 하향식 배출량의 개선을 위해서는 관측 불확도를 줄이는 것이 중요하다. 불확도를 높이는 요소의 하나는 지상에서 항공기가 운행될 수 있는 최저 고도까지 관측을 하지 않은 것이다. 이러한 불확도를 줄이는 방법은 지상에서 관측을 수행하며, 더 나아가서는 지상과 항공기 관측 최저 고도 사이에서 드론 등의 방법을 통해 관측을 수행하는 것이다. 바람장 역시 관측 및 외삽과 내삽을 이용하여 평면 분포를 구하면 평면에 대한 적분을 이용하여 평면 전체의 플럭스를 구할 수 있어 불확도를 줄일 수 있을 것이다. 상향식 배출량의 정확도 개선을 위해서는 측정이 이루어지고 있는 굴뚝의 배출량 자료 정확도 개선과 함께, 관측이 이루어지고 있지 않은 배출구의 현황 파악이 필요하다.

광산란법을 이용한 국내 석탄화력발전소 굴뚝에서 배출되는 PM10, PM2.5 측정 및 분석 (Measurement and analysis of PM10 and PM2.5 from chimneys of coal-fired power plants using a light scattering method)

  • 신동호;김영훈;홍기정;이건희;박인용;김학준;김용진;한방우;황정호
    • 한국입자에어로졸학회지
    • /
    • 제16권4호
    • /
    • pp.131-140
    • /
    • 2020
  • Air pollutants emitted from chimneys of coal-fired power plants are considered to be a major source of fine particulate matter in the atmosphere. In order to manage fine particle in the chimney of a coal-fired power plant, it is necessary to know the concentration of fine particle emitted in real time, but the current system is difficult. In this study, a real-time measurement system for chimney fine particle was developed, and measurements were performed on six coal-fired power plants. Through the measurements, the mass concentration distribution according to the particle size could be secured. All six chimneys showed bimodal distribution, and the count median diameters of each mode were 0.5 and 1.1 ㎛. In addition, it was compared with the gravimetric measurement method, and it was determined that the relative accuracy for PM10 was within 20%, and the value measured using the developed measuring instrument was reliable. Finally, three power plants were continuously measured for one month, and as a result of comparing the concentration of PM10 according to the amount of power generation, it was confirmed that the PM10 discharged from the chimney increased in the form of an exponential function according to the amount of power generation.

화학적·광학적·분광학적 방법을 이용한 광주 도심지역 여름철 초미세먼지의 특성 (Characterization of fine particulate matter during summer at an urban site in Gwangju using chemical, optical, and spectroscopic methods)

  • 손세창;박태언;박승식
    • 한국입자에어로졸학회지
    • /
    • 제17권4호
    • /
    • pp.91-106
    • /
    • 2021
  • Daily PM2.5 was collected during summer period in 2020 in Gwangju to investigate its chemical and light absorption properties. In addition, real-time light absorption coefficients were observed using a dual-spot 7-wavelength aethalometer. During the study period, SO42- was the most important contributor to PM2.5, accounting for on average 33% (10-64%) of PM2.5. The chemical form of SO42- was appeared to be combination of 70% (NH4)2SO4 and 30% NH4HSO4. Concentration-weighted trajectory (CWT) analysis indicated that SO42- particles were dominated by local pollution, rather than regional transport from China. A combination of aethalometer-based and water-extracted brown carbon (BrC) absorption indicated that light absorption of BrC due to aerosol particles was 1.6 times higher than that due to water-soluble BrC, but the opposite result was found in absorption Ångström exponent (AAE) values. Lower AAE value by aerosol BrC particles was due to the light absorption of aerosol BrC by both water-soluble and insoluble organic aerosols. The BrC light absorption was also influenced by both primary sources (e.g., traffic and biomass burning emissions) and secondary organic aerosol formation. Finally the ATR-FTIR analysis confirmed the presence of NH4+, C-H groups, SO42-, and HSO42-. The presence of HSO42- supports the result of the estimated composition ratio of inorganic sulfate ((NH4)2SO4) and bisulfate (NH4HSO4).

지하역사 승강장 공조 시스템 필터용 항바이러스 코팅 성능 및 재생 성능 평가 (Development of Optimal Antiviral Coating Method for the Air Filtration System of Subway Station)

  • 박대훈;황정호;신동호;김영훈;이건희;박인용;김상복;홍기정;한방우
    • 한국입자에어로졸학회지
    • /
    • 제18권1호
    • /
    • pp.9-21
    • /
    • 2022
  • In this study, a novel antiviral coating method for the air filtration system of subway station was investigated. Using dry aerosol coating process, we developed a high-performance antiviral air filter with spark discharger and carbon brush type ionizer. Silver nanoparticles were produced by a spark discharge generation system with ion injection system and were used as antiviral agents coated onto a medium grade air filter. The pressure drop, filtration efficiency, and antiviral ability of the filter against aerosolized MS2 virus particles as a surrogate of SARS-CoV-2 virus were tested with dust contamination. Dust contamination caused the increase of the filtration efficiency and pressure drop, while the antiviral agents (in this study, silver nanoparticles) coating did not have any significant effect on the filtration efficiency and pressure drop. Using these properties, we suggested a novel method to maximize the antiviral performance of the antiviral air filter that was contaminated by dust particles. Moreover theoretical analysis of antiviral ability with dust contamination and re-coated antiviral agents was carried out using a mathematical model to calculate the time-dependent antiviral effect of the filter under actual conditions of subway station. Our model can be used to apply on antiviral air filtration system of subway station for prevention of pandemic diffusion, and predict the life cycle of an antiviral filter.

대기입자상물질의미생물메타게놈: 분석방법, 특성및영향인자 (Microbial Metagenome of Airborne Particulate Matter: Methodology, Characteristics, and Influencing Parameters)

  • 강수경;조경숙
    • 한국미생물·생명공학회지
    • /
    • 제50권2호
    • /
    • pp.165-192
    • /
    • 2022
  • 본 논문에서는 실외 대기 환경의 바이오에어로졸 혹은 입자상물질의 미생물 메타게놈 특성과 이에 영향을 미치는 기후 및 환경 인자의 영향을 고찰하였다. 시료 채취 지역 및 환경 조건 특성별 대기 중 세균과 곰팡이 농도를 요약 하고, 에어로졸과 PM 시료의 세균과 곰팡이의 메타게놈 특성을 조사하기 위한 비배양법 기반 분석방법과 메타게놈 특성을 정리하였다. 또한, 세균과 곰팡이의 메타게놈 특성과 다양성 및 특성에 미치는 기상 인자와 환경 인자의 영향을 고찰하였다. 대기 중 미생물의 생존, 생장과 분산은 지역 기상 조건 및 대기 오염 물질에 의해 크게 영향을 받았다. 일반적으로 기온이 상승함에 따라 AM 농도는 증가하지만, 여름에는 고온과 강한 자외선의 영향으로 AM 농도가 감소하였다. 습도와 미생물 농도는 양의 상관성을 보이나, 습도가 너무 높으면 AM의 분산이 지연되었다. 이러한 종합적인 고찰 결과는 대기권에서 미생물의 역할과 기능을 이해하고, 이들 미생물에 의해 야기되는 환경 및 공중보건 문제를 해결하기 위한 전략 수립 및 저감 기술 개발에 활용될 수 있다.