• Title/Summary/Keyword: 에너지관리기술

Search Result 1,268, Processing Time 0.024 seconds

Relationships of Changing Social Atmosphere, Lifestyle and Bone Mineral Density in College Students (대학생의 골밀도와 사회분위기 및 생활습관과의 관계)

  • Lee, In-Ja;Ko, Yo-Han;Kim, Chung-Kyung;Kim, Hee-Sol;Park, Da-Jeong;Yoon, Hyeo-Min;Jeong, Yu-Jin
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.263-271
    • /
    • 2013
  • The decrease of bone mineral density gives rise to the outbreak of osteopenia and makes the possibility of a bone fracture. It makes health problems in society. It's very important to prevent osteopenia in advance. Also it's critical to prevent and take care of it in adolescent because it's the most developing period comparing to middle ages because that bone mineral density decreases. There are genetic, physical and enviromental factors that affect bone mineral density. Recently, a lifestyle and eating habits are also changing as the society atmosphere is gradually doing. This study have shown that 134 women and 75 men was chosen and responded to the survey of measuring bone mineral density and investigating a lifestyle. The measure of bone mineral density is to use Dual energy X-ray absorptiometry(DEXA) and check femoral neck and lumbar spine. Also questionaries was required to pre-made survey about their lifestyles. Analysis of data was done with SPSS program. Multiple regression analysis was used for the relation of bone mineral density, the heigths and BMI. The sample of Groups are checked for drinking, smoking or excercising about differences by t-test. The results of the experiments were; first, there is statistically significant differences in the comparisons between BMD and BMD. But there isn't any special correlation between drinking, smoking and BMD. Secondly, bone mineral density becomes low related to an intake of caffeine. Particularly, this is statically significant on women. Also there is statically significant correlation between femoral neck and quantity of motion for both men and women. Third, there is significant relation between eating habits and bone mineral density on women's lumbar spine. However, there is no significant relation between men's lumbar spine and women's one. Therefore, to prevent osteopenia, it's good to abstain from intaking caffeine within an hour after a meal. In addition, it's helpful to walk or run regularly and have a balanced meal.

The Relationship Between DEA Model-based Eco-Efficiency and Economic Performance (DEA 모형 기반의 에코효율성과 경제적 성과의 연관성)

  • Kim, Myoung-Jong
    • Journal of Environmental Policy
    • /
    • v.13 no.4
    • /
    • pp.3-49
    • /
    • 2014
  • Growing interest of stakeholders on corporate responsibilities for environment and tightening environmental regulations are highlighting the importance of environmental management more than ever. However, companies' awareness of the importance of environment is still falling behind, and related academic works have not shown consistent conclusions on the relationship between environmental performance and economic performance. One of the reasons is different ways of measuring these two performances. The evaluation scope of economic performance is relatively narrow and the performance can be measured by a unified unit such as price, while the scope of environmental performance is diverse and a wide range of units are used for measuring environmental performances instead of using a single unified unit. Therefore, the results of works can be different depending on the performance indicators selected. In order to resolve this problem, generalized and standardized performance indicators should be developed. In particular, the performance indicators should be able to cover the concepts of both environmental and economic performances because the recent idea of environmental management has expanded to encompass the concept of sustainability. Another reason is that most of the current researches tend to focus on the motive of environmental investments and environmental performance, and do not offer a guideline for an effective implementation strategy for environmental management. For example, a process improvement strategy or a market discrimination strategy can be deployed through comparing the environment competitiveness among the companies in the same or similar industries, so that a virtuous cyclical relationship between environmental and economic performances can be secured. A novel method for measuring eco-efficiency by utilizing Data Envelopment Analysis (DEA), which is able to combine multiple environmental and economic performances, is proposed in this report. Based on the eco-efficiencies, the environmental competitiveness is analyzed and the optimal combination of inputs and outputs are recommended for improving the eco-efficiencies of inefficient firms. Furthermore, the panel analysis is applied to the causal relationship between eco-efficiency and economic performance, and the pooled regression model is used to investigate the relationship between eco-efficiency and economic performance. The four-year eco-efficiencies between 2010 and 2013 of 23 companies are obtained from the DEA analysis; a comparison of efficiencies among 23 companies is carried out in terms of technical efficiency(TE), pure technical efficiency(PTE) and scale efficiency(SE), and then a set of recommendations for optimal combination of inputs and outputs are suggested for the inefficient companies. Furthermore, the experimental results with the panel analysis have demonstrated the causality from eco-efficiency to economic performance. The results of the pooled regression have shown that eco-efficiency positively affect financial perform ances(ROA and ROS) of the companies, as well as firm values(Tobin Q, stock price, and stock returns). This report proposes a novel approach for generating standardized performance indicators obtained from multiple environmental and economic performances, so that it is able to enhance the generality of relevant researches and provide a deep insight into the sustainability of environmental management. Furthermore, using efficiency indicators obtained from the DEA model, the cause of change in eco-efficiency can be investigated and an effective strategy for environmental management can be suggested. Finally, this report can be a motive for environmental management by providing empirical evidence that environmental investments can improve economic performance.

  • PDF

Application of OECD Agricultural Water Use Indicator in Korea (우리나라에 적합한 OECD 농업용수 사용지표의 설정)

  • Hur, Seung-Oh;Jung, Kang-Ho;Ha, Sang-Keun;Song, Kwan-Cheol;Eom, Ki-Cheol
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.39 no.5
    • /
    • pp.321-327
    • /
    • 2006
  • In Korea, there is a growing competitive for water resources between industrial, domestic and agricultural consumer, and the environment as many other OECD countries. The demand on water use is also affecting aquatic ecosystems particularly where withdrawals are in excess of minimum environmental needs for rivers, lakes and wetland habits. OECD developed three indicators related to water use by the agriculture in above contexts : the first is a water use intensity indicator, which is expressed as the quantity or share of agricultural water use in total national water utilization; the second is a water stress indicator, which is expressed as the proportion of rivers (in length) subject to diversion or regulation for irrigation without reserving a minimum of limiting reference flow; and the third is a water use efficiency indicator designated as the technical and the economic efficiency. These indicators have different meanings in the aspect of water resource conservation and sustainable water use. So, it will be more significant that the indicators should reflect the intrinsic meanings of them. The problem is that the aspect of an overall water flow in the agro-ecosystem and recycling of water use not considered in the assessment of agricultural water use needed for calculation of these water use indicators. Namely, regional or meteorological characteristics and site-specific farming practices were not considered in the calculation of these indicators. In this paper, we tried to calculate water use indicators suggested in OECD and to modify some other indicators considering our situation because water use pattern and water cycling in Korea where paddy rice farming is dominant in the monsoon region are quite different from those of semi-arid regions. In the calculation of water use intensity, we excluded the amount of water restored through the ground from the total agricultural water use because a large amount of water supplied to the farm was discharged into the stream or the ground water. The resultant water use intensity was 22.9% in 2001. As for water stress indicator, Korea has not defined nor monitored reference levels of minimum flow rate for rivers subject to diversion of water for irrigation. So, we calculated the water stress indicator in a different way from OECD method. The water stress indicator was calculated using data on the degree of water storage in agricultural water reservoirs because 87% of water for irrigation was taken from the agricultural water reservoirs. Water use technical efficiency was calculated as the reverse of the ratio of irrigation water to a standard water requirement of the paddy rice. The efficiency in 2001 was better than in 1990 and 1998. As for the economic efficiency for water use, we think that there are a lot of things to be taken into considerations to make a useful indicator to reflect socio-economic values of agricultural products resulted from the water use. Conclusively, site-specific, regional or meteorogical characteristics as in Korea were not considered in the calculation of water use indicators by methods suggested in OECD(Volume 3, 2001). So, it is needed to develop a new indicators for the indicators to be more widely applicable in the world.

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF

The Study of Land Surface Change Detection Using Long-Term SPOT/VEGETATION (장기간 SPOT/VEGETATION 정규화 식생지수를 이용한 지면 변화 탐지 개선에 관한 연구)

  • Yeom, Jong-Min;Han, Kyung-Soo;Kim, In-Hwan
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.13 no.4
    • /
    • pp.111-124
    • /
    • 2010
  • To monitor the environment of land surface change is considered as an important research field since those parameters are related with land use, climate change, meteorological study, agriculture modulation, surface energy balance, and surface environment system. For the change detection, many different methods have been presented for distributing more detailed information with various tools from ground based measurement to satellite multi-spectral sensor. Recently, using high resolution satellite data is considered the most efficient way to monitor extensive land environmental system especially for higher spatial and temporal resolution. In this study, we use two different spatial resolution satellites; the one is SPOT/VEGETATION with 1 km spatial resolution to detect coarse resolution of the area change and determine objective threshold. The other is Landsat satellite having high resolution to figure out detailed land environmental change. According to their spatial resolution, they show different observation characteristics such as repeat cycle, and the global coverage. By correlating two kinds of satellites, we can detect land surface change from mid resolution to high resolution. The K-mean clustering algorithm is applied to detect changed area with two different temporal images. When using solar spectral band, there are complicate surface reflectance scattering characteristics which make surface change detection difficult. That effect would be leading serious problems when interpreting surface characteristics. For example, in spite of constant their own surface reflectance value, it could be changed according to solar, and sensor relative observation location. To reduce those affects, in this study, long-term Normalized Difference Vegetation Index (NDVI) with solar spectral channels performed for atmospheric and bi-directional correction from SPOT/VEGETATION data are utilized to offer objective threshold value for detecting land surface change, since that NDVI has less sensitivity for solar geometry than solar channel. The surface change detection based on long-term NDVI shows improved results than when only using Landsat.

Alternative Concept to Enhance the Disposal Efficiency for CANDU Spent Fuel Disposal System (CANDU 사용후핵연료 처분시스템 효율향상 개념 도출)

  • Lee, Jong-Youl;Cho, Dong-Geun;Kook, Dong-Hak;Lee, Min-Soo;Choi, Heui-Joo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.9 no.3
    • /
    • pp.169-179
    • /
    • 2011
  • There are two types of nuclear reactors in Korea and they are PWR type and CANDU type. The safe management of the spent fuels from these reactors is very important factor to maintain the sustainable energy supply with nuclear power plant. In Korea, a reference disposal system for the spent fuels has been developed through a study on the direct disposal of the PWR and CANDU spent fuel. Recently, the research on the demonstration and the efficiency analyses of the disposal system has been performed to make the disposal system safer and more economic. PWR spent fuels which include a lot of reusable material can be considered being recycled and a study on the disposal of HLW from this recycling process is being performed. CANDU spent fuels are considered being disposed of directly in deep geological formation, since they have little reusable material. In this study, based on the Korean Reference spent fuel disposal System (KRS) which was to dispose of both PWR type and CANDU type, the more effective CANDU spent fuel disposal systems were developed. To do this, the disposal canister for CANDU spent fuels was modified to hold the storage basket for 60 bundles which is used in nuclear power plant. With these modified disposal canister concepts, the disposal concepts to meet the thermal requirement that the temperature of the buffer materials should not be over $100^{\circ}C$ were developed. These disposal concepts were reviewed and analyzed in terms of disposal effective factors which were thermal effectiveness, U-density, disposal area, excavation volume, material volume etc. and the most effective concept was proposed. The results of this study will be used in the development of various wastes disposal system together with the HLW wastes from the PWR spent fuel recycling process.

Effects of Maternal Genetic Potential and Parity with Pre- and Postpartum on Body Weights, Body Condition Score and Blood Metabolites in Hanwoo Cows (한우 암소의 유전능력과 산차에 따른 분만 전?후 체중, Body Condition Score 및 혈중 대사물질의 변화)

  • 권응기;조영무;최연호;박병기;정학재;최낙진;안병석;김종복
    • Journal of Animal Science and Technology
    • /
    • v.48 no.6
    • /
    • pp.881-888
    • /
    • 2006
  • This study was conducted to investigate effects of maternal genetic potential and parity with pre- and postpartum periods on body weights, body condition score (BCS) and blood metabolites in relation to physiological stress and nutritional metabolism in Hanwoo cows. Also, this study was designed to develop effective husbandry technique for Hanwoo cows concerning of pre- and postpartum periods, and to get basic data for it. Forty five cows were allocated into two groups, 24 cows with high maternal genetic potentials and 21 cows with low maternal genetic potentials. The average parity of experimental cows with high and low maternal genetic potentials were 2.83±1.63 and 3.00±1.77, respectively. The growth performances such as body weights, average daily gain (ADG) and BCS were not different between two groups regardless of maternal genetic potential. However, pre- and postpartum periods had effects on the growth performances (p<0.05). Parity had no effects on ADG and BCS (p>0.05), but effect on body weight of cows (p<0.05). The metabolites of physiological stress such as neutrophil, hematocrit and cortisol, and nutritional metabolites such as albumin, blood urea nitrogen (BUN), triglyceride, and non-esterified fatty acid (NEFA) concentrations in blood of cows were affected by pre- and postpartum periods in a large scale, while those were partially affected by maternal genetic potential. However, among the metabolites in blood, only neutrophil and triglylceride concentrations were affected by different parity of cows. Therefore, the present study suggests that nutritional intake and digestion are affected by physiological stress due to the parturition, and it should need to consider different husbandry technique based on the maternal genetic potential, and pre- and postpartum periods of cows.

The Consideration of nuclear medicine technologist's occupational dose from patient who are undergoing 18F-FDG Whole body PET/CT : Aspect of specific characteristic of patient and contact time with patient (18F-FDG Whole Body PET/CT 수검자의 거리별 선량 변화에 따른 방사선 작업종사자의 유효선량 고찰: 환자 고유특성 및 응대시간 측면)

  • Kim, Sunghwan;Ryu, Jaekwang;Ko, Hyunsoo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.67-75
    • /
    • 2018
  • Purpose The purpose of this study is to investigate and analyze the external dose rates of $^{18}F-FDG$ Whole Body PET/CT patients by distance, and to identify the main factors that contribute to the reduction of radiation dose by checking the cumulative doses of nuclear medicine technologist(NMT). Materials and Methods After completion of the $^{18}F-FDG$ Whole Body PET/CT scan($75.4{\pm}3.3min$), the external dose rates of 106 patients were measured at a distance of 0, 10, 30, 50, and 100 cm from the chest. Gender, age, BMI(Body Mass Index), fasting time, diabetes mellitus, radiopharmaceutical injection information, creatine value were collected to analyze individual factors that could affect external dose rates from a patient's perspective. From the perspective of NMT, personal pocket dosimeters were worn on the chest to record accumulated dose of NMT who performed the injection task($T_1$, $T_2$ and $T_3$) and scan task($T_4$, $T_5$ and $T_6$). In addition, patient contact time with NMT was measured and analyzed. Results External dose rates from the patient for each distance were calculated as $246.9{\pm}37.6$, $129.9{\pm}16.7$, $61.2{\pm}9.1$, $34.4{\pm}5.9$, and $13.1{\pm}2.4{\mu}Sv/hr$ respectively. On the patient's aspect, there was a significant difference in the proximity of gender, BMI, Injection dose and creatine value, but the difference decreased as the distance increased. In case of dialysis patient, external dose rates for each distance were exceptionally higher than other patients. On the NMT aspect, the doses received from patients were 0.70, 1.09, $0.55{\mu}Sv/person$ for performing the injection task($T_1$, $T_2$, and $T_3$), and were 1.25, 0.82, $1.23{\mu}Sv/person$ for performing the scan task($T_4$, $T_5$, $T_6$). Conclusion we found that maintaining proper distance with patient and reducing contact time with patient had a significant effect on accumulated doses. Considering those points, efforts such as sufficient water intake and encourage of urination, maintaining the proper distance between the NMT and the patient(at least 100 cm), and reducing the contact time should be done for reducing dose rates not only patient but also NMT.