• Title/Summary/Keyword: 양안융합

Search Result 31, Processing Time 0.022 seconds

The Study on Relation between Asthenopia of Lateral Phoria and Fusional Reserve (수평사위의 안정피로와 융합여력과의 관계)

  • Kim, Jung-Hee;Ryu, Kyung-Ho;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.4
    • /
    • pp.329-335
    • /
    • 2006
  • The aim of this study was to evaluate the relation between Asthenopia of near lateral phoria and fusional reserve and also to provide fundamental clinical data. A total of 97 subjects, aged between 17 and 35 years old, who had no strabismus, an eye trouble or whole body disease, were examined nacked visual acuity, corrected visual acuity, corrected diopter, phoria, fusional reserve tests from October of 2005 to July of 2006. We excluded 8 subjects for the following reasons: if they had an amblyopia affecting binocular vision or inaccurate data. After these exclusions, 87 subjects remained. The results were as follow. According to interview results was that in near works, exophoria and esophoria with asthenopia was 59.6%, 64.7%, and 52.6% respectively. The subjects who have exophoria of $0-6{\Delta}$ in the range of normal state was 19.1%. The subjects who have exophoria of $7{\Delta}$ over in the range of abnormal state was 80.9%. The fusional reserve was in inverse proportion to phoria. The fusional reserve was twice over of phoria were 30.3%, and twice under were 69.7%. The asthenopia complain persons were 33.9% with the twice over fusional reserve of phoria. The asthenopia no complain persons were 66.1% with the twice under fusional reserve of phoria. In conclusion, our research has shown conclusively that there is a link between asthenopia of lateral phoria and fusional reserve and we also find that fusional reserve must be examined when we prescribe for a patient who has phoria.

  • PDF

Effect of Overcorrection (-)Lens on Stereo-acuity and Angle of Deviation in Intermittent Exotropia (간헐외사시에서 과교정 (-)렌즈가 입체시 및 사시각에 미치는 영향)

  • Kim, Young Cheong;Park, Sang Woo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.305-311
    • /
    • 2013
  • Purpose: This study was conducted to evaluate the effect of prescription of overcorrection (-) lens, which is the one of the non-surgical treatments, on stereo-acuity and angle of deviation in intermittent exotropia. Methods: Twenty four children with intermittent exotropia were enrolled from October 2011 to December 2011. The angle of deviation(${\Delta}$), stereo-acuity (arcsec), monocular and binocular visual acuity (BVA, LogMAR), control of exodeviation and fusional ability using Worth 4 dot test were evaluated at near (33 cm) and far (6 m), under the overcorrecting (-)lens of -1.00, -.00, and -.00 D. Results: As a baseline finding, the angle of exodeviation was $20.9{\pm}9.7$ at near and $23.0{\pm}7.5$ at far. The angle of exodeviation at near decreased to $18.5{\pm}10.0$ (p<0.01), $15.8{\pm}9.0$ (p<0.01), $14.0{\pm}9.1$ (p<0.01) compared with baseline angle of exodeviation at near, as increasing diopters of (-) lens from -.00 D, -2.00 D and -.00 D, respectively. The angle of exodeviation at far also decreased to $21.4{\pm}5.2$ (p=0.01), $19.6{\pm}6.3$ (p<0.01) compared with baseline, as increasing minus lens from -2.00 D and -3.00 D, respectively. However, BVA, control of exodeviation, fusional ability and stereo-acuity showed no significant decrease despite of increasing diopters of (-)lens. Conclusions: The prescription of overcorrection (-)lens is an effective therapeutic method in intermittent exotropia which can reduce the near and far angle of exodeviation, and binocular visual acuity and stereo-acuity maintained without significant decrease despite of application of overcorrection (-)lens.

A Case of 17q22 with Interstitial Deletion (염색체 17q22 염색체내 결손으로 진단된 1례)

  • Kang, So-Yeon;Lee, Beom-Hee;Kim, Gu-Hwan;Choi, Jin-Ho;Yoo, Han-Wook
    • Journal of Genetic Medicine
    • /
    • v.8 no.1
    • /
    • pp.58-61
    • /
    • 2011
  • Cases of interstitial deletions of the long arm of chromosome 17 are very rare, with only nine cases ever reported worldwide. We describe a 12-year-old boy with profound developmental delay, microcephaly, facial dysmorphism, contracture of the large joints and bilateral hearing loss. A chromosomal study using a peripheral blood sampled revealed 46,XY,del(17)(q22q23). To our knowledge, he is the first case of interstitial deletion of the long arm of chromosome 17 ever reported in Korea.

A review of space perception applicable to artificial intelligence robots (인공지능 로봇에 적용할 수 있는 공간지각에 대한 종설)

  • Lee, Young-Lim
    • Journal of Digital Convergence
    • /
    • v.17 no.10
    • /
    • pp.233-242
    • /
    • 2019
  • Numerous space perception studies have shown that Euclidean 3-D structure cannot be recovered from binocular stereopsis, motion, combination of stereopsis and motion, or even with combined multiple sources of optical information. Humans, however, have no difficulties to perform the task-specific action despite of poor shape perception. We have applied humans skill and capabilities to artificial intelligence and computer vision but those machines are still far behind from humans abilities. Thus, we need to understand how we perceive depth in space and what information we use to perceive 3-D structure accurately to perform. The purpose of this paper was to review space perception literatures to apply humans abilities to artificial intelligence robots more advanced in future.

Possibility about evaluation test of Substitution of NPC Alteration for AC/A Ratio (폭주근점 변화의 AC/A비 대체 평가지표에 대한 가능성)

  • Yoo, Hyun;Lee, Eun-Hee
    • Journal of Digital Convergence
    • /
    • v.14 no.10
    • /
    • pp.375-380
    • /
    • 2016
  • This study aimed to evaluate the possibility for assessment of binocular visual function about alteration for near point of convergence (NPC). Study subjects were total 30 (emmetropia 16, myopia 14), who had no eye disease except for the phoria and monocular corrected vision 1.0 and over. Near point of accommodation (NPA), NPC and phoria test were measured both at ordinary and stimulation of +1D. Ordinary NPC was 1.77cm shorter than NPC stimulated +1D and the NPC of emmetropia was shorter than that of myopia. The difference between NPC stimulated +1D and ordinary were increased in the emmetropia. As the NPC increased, the AC/A ratio was elevated and the feature of near exophoria appeared. The results suggested that the alteration of NPC might substitute AC/A ratio for reference variable of binocular vision. If converged and analyzed comparatively with another binocular visual evaluation test, the alteration of NPC could be developed for substitution of evaluation test.

The Relationship Fixation Disparity between Associated Phoria (주시시차와 각비정시의 관계)

  • Kim, Hyun-Il
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.93-104
    • /
    • 2004
  • In order to have a comfortable vision without any asthenopia in work place, it is very necessary to make a complete binocular correction in addition to the perfect correction of refractive deficits. For this, At first, the exact understanding of the required corrective value of the existing angular ametropia(associated phoria) is needed. The fact likely seems fact that a correction of refractive deficits could not to be reached with single optotype, the corrections of angular ametropia(associated phoria) with single optotype is impossible. The reason is that a most ametropia(associated phoria) is accompanied with the fixation disparity. To make a perfect measurement of ametropia(associated phoria), at least, 3 kinds of optotype is essential. This fact could be explained by stating the fusional stimulus in the binocular refraction tests on each eye. If these types of three tests have not practical practice. The most of many cases may result in undercorrection.

  • PDF

From Broken Visions to Expanded Abstractions (망가진 시선으로부터 확장된 추상까지)

  • Hattler, Max
    • Cartoon and Animation Studies
    • /
    • s.49
    • /
    • pp.697-712
    • /
    • 2017
  • In recent years, film and animation for cinematic release have embraced stereoscopic vision and the three-dimensional depth it creates for the viewer. The maturation of consumer-level virtual reality (VR) technology simultaneously spurred a wave of media productions set within 3D space, ranging from computer games to pornographic videos, to Academy Award-nominated animated VR short film Pearl. All of these works rely on stereoscopic fusion through stereopsis, that is, the perception of depth produced by the brain from left and right images with the amount of binocular parallax that corresponds to our eyes. They aim to emulate normal human vision. Within more experimental practices however, a fully rendered 3D space might not always be desirable. In my own abstract animation work, I tend to favour 2D flatness and the relative obfuscation of spatial relations it affords, as this underlines the visual abstraction I am pursuing. Not being able to immediately understand what is in front and what is behind can strengthen the desired effects. In 2015, Jeffrey Shaw challenged me to create a stereoscopic work for Animamix Biennale 2015-16, which he co-curated. This prompted me to question how stereoscopy, rather than hyper-defining space within three dimensions, might itself be used to achieve a confusion of spatial perception. And in turn, how abstract and experimental moving image practices can benefit from stereoscopy to open up new visual and narrative opportunities, if used in ways that break with, or go beyond stereoscopic fusion. Noteworthy works which exemplify a range of non-traditional, expanded approaches to binocular vision will be discussed below, followed by a brief introduction of the stereoscopic animation loop III=III which I created for Animamix Biennale. The techniques employed in these works might serve as a toolkit for artists interested in exploring a more experimental, expanded engagement with stereoscopy.

A Comparative Study on Quantity of Phoria between New Phoria Measurement with 3D Display and Existing Methods (개발된 3D Display 장치를 이용한 사위검사법과 기존 사위검사법으로 측정한 사위량 비교에 관한 연구)

  • Kang, Seok Hyon;Hong, Hyungki
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.313-320
    • /
    • 2013
  • Purpose: This study compared the quantity of phoria for distance by new method with that by existing methods. Methods: For this study, it was selected to two existing phoria measurements, von Graefe and Maddox rod. And new method named "3D polarizing phoria measurement" was designed to measure the quantity of phoria using polarizing glasses and 3D display. Unlike existing measurement using polarized lens, newly considered method measured the quantity of phoria in condition removed perfect binocular fusion using field stop on apparatus and polarized lens. For using new method for distance, it was developed a phoria test chart. It supports three kinds of phoria measurements. Subjects were 12 (male 6, female 6). They had three phoria tests (1 sets) including new method. It was considered the effect of experimental order, so we tested all cases about experimental order. The number of cases was 6 sets, and the sample size in this experiment was 72 sets. For removing binocular fusion, lighting of the laboratory that was below 10 lx and the background color of phoria test chart was dark, RGB=(20, 20, 20). Results: Subjects were sorted into three groups. Samples with exophoria and orthophoria were 30 sets each, and those with esophoria were 12 sets. The quantity of phoria measured three tests differ from each other like "newmethod < von Graefe < Maddox rod", and there were statistically significant difference each other. Conclusions: This study has great significance in the sense that new method was the measurement with naturally removing binocular fusion without dizziness during the tests.

The Functional Change of Accommodation and Convergence in the Mid-Forties by Using Smartphone (스마트폰 사용에 의한 40대 중년층의 조절 및 폭주기능 변화)

  • Kwon, Ki-il;Kim, Hyun Jin;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.2
    • /
    • pp.127-135
    • /
    • 2016
  • Purpose: The present study was aimed to investigate the effect of excessive near work by using a smartphone on subjective symptoms and accommodative and convergent function in their 40s. Methods: A total of 40 subjects(male, 10; female, 30; age, $43{\pm}7.2year$) in their 40s who have monocular and binocular visual acuities of 0.8 and 1.0, respectively, were divided into presbyopia group and non-presbyopia group. The subjects were asked to watch a movie on the screen of smartphone for 30 minutes. Their accommodative amplitude and facility, and relative accommodation were measured and compared before and after the use of smartphone. Changes in fusional vergence and near heterophoria by using smartphone were also evaluated. Furthermore, the change of subjective symptoms was surveyed using a questionnaire. Results: The presbyopia in mid-40s reported discomfort in an order of asthenopia, blur and dryness after the use of smartphone. Accommodative function and non-strabismic binocular function were generally decreased. Accommodative functions such as monocular accommodative amplitude, and relative accommodation were significantly decreased after smartphone use, and the change of phoria was observed as a result of decreased convergence and divergence. Negative fusional vergence was also significantly reduced. On the other hand, non-presbyopia in mid-40s reported discomfort in an order of asthenopia, dryness and blur, and only accommodative amplitude among the accommodative functions was significantly reduced. Significant reduction of negative fusional vergence was also observed. Conclusion: From the results, it was confirmed that the subjective discomfort of mid-40s after smarphone use might be related to whether presbyopia or not. It was due to not only the reduction of accommodative function but also the overall deterioration of visual function including heterophoria and fusional vergence. Therefore, it suggests that the accurate determination of the cause based on the overall visual functional tests such as heterophoria, fusional vergence as well as the decrease of accommodation due to the aging may be necessary when the mid-40s feels discomfortable symptoms by near work.

The Study on Effects of After Vision Training for Elementary School Children in Muan (무안군 소재 초등학생들의 시훈련 효과에 관한 연구)

  • Jang, Jung Un;Kim, In Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.137-142
    • /
    • 2013
  • Purpose: This study was designed to investigate the current status of visual acuity for elementary school students in Muan-gun and to analyze improvements of their visual function after vision training for the elementary school students who have either insufficiency of accommodation or vergence. Methods: Subjective refraction, objective refraction and binocular function were examined for 335 elementary school children from year 1 to year 6 live in Muan area, and then 47 students who have symptoms of binocular dysfunction among them were selected. We analyzed and compared between before and after vision training (VT) in binocular vision function results. Results: The results show that most of the subjects had much problem in near point convergence (NPC) than accommodation. After the vision training, the average of subjects NPC was improved about 5.93 cm, from $11.57 {\pm}1.850$ cm for before VT to $5.66{\pm}0.965$ cm for after VT. After VT positive fusional vergence at near distance after VT was $19.64{\pm}3.66$ $\Delta$, which was as much as double of near phoria. Accommodative amplitude was improved from $10.02{\pm}2.566$ D for before VT to $12.30{\pm}1.397$ D for after VT, which similar to mean of expected accommodative amplitude of 11.27 years old. Conclusions: Among insufficiency of accommodation and vergence NPC was improved specially, and accommodative facility and other ocular functions were also improved. Therefore, it is considered the vision training is very effective to recover from visual function problems.