• Title/Summary/Keyword: 액체크로마토그래프

Search Result 45, Processing Time 0.022 seconds

Investigation of Validation Guidelines for Performance Verification of High Performance Liquid Chromatograph (고성능 액체크로마토그래프 기기의 성능검증을 위한 밸리데이션 가이드라인에 대한 연구)

  • Yun, Won Nam;Lee, Beom-Gyu;Lee, Wonjae
    • YAKHAK HOEJI
    • /
    • v.57 no.5
    • /
    • pp.362-368
    • /
    • 2013
  • High performance liquid chromatograph (HPLC) is the most frequently used analytical instrument in analytical laboratories for pharmaceutical analysis. In order to provide a high level of assurance for reliable data generated from the HPLC analysis, the performance qualification of the HPLC system is required. For this purpose, the performance of HPLC system should be regularly monitored by examining the key functions of the typical HPLC system (solvent delivery system, injector system, column oven, UV-VIS detector system). We have investigated the validation guidelines of the performance verification of these key modules for HPLC system. And we proposed and evaluated its validation guidelines and the related verification methods for pharmaceutical analysis that could be practically applied in Korea.

Optimization of LC-MS/MS for the Analysis of Sulfamethoxazole by using Response Surface Analysis (반응표면분석법을 이용한 설파메톡사졸의 액체크로마토그래프-텐덤형 질량분석 최적화)

  • Bae, Hyo-Kwan;Jung, Jin-Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.9
    • /
    • pp.825-830
    • /
    • 2009
  • Pharmaceutical compounds enter the water environment through the diverse pathways. Because their concentration in the water environment was frequently detected in the level of ppt to ppb, the monitoring system should be optimized as much as possible for finding appropriate management policies and technical solutions. One Factor At a Time (OFAT) approach approximating the response with a single variable has been preferred for the optimization of LC-MS/MS operational conditions. However, it is common that variables in analytical instruments are interdependent. Therefore, the best condition could be found by using the statistical optimization method changing multiple variables at a time. In this research, response surface analysis (RSA) was applied to the LC-MS/MS analysis of emerging antibiotic compound, sulfamethoxazole, for the best sensitivity. In the screening test, fragmentation energy and collision voltage were selected as independent variables. They were changed simultaneously for the statistical optimization and a polynomial equation was fit to the data set. The correlation coefficient, $R^2$ valuerepresented 0.9947 and the error between the predicted and observed value showed only 3.41% at the random condition, fragmentation energy of 60 and collision voltage of 17 eV. Therefore, it was concluded that the model derived by RSA successfully predict the response. The optimal conditions identified by the model were fragmentation energy of 116.6 and collision voltage of 10.9 eV. This RSA can be extensively utilized for optimizing conditions of solid-phase extraction and liquid chromatography.

A simple method to determine lycopene in solid supplementary food preparations using saponification and liquid chromatography (비누화 및 액체크로마토그래프를 활용한 고상 건강기능식품 중 라이코펜 분석법 개발)

  • Young Min Kim;Ye Bin Shin;Min Kyeong Kwon;Jin Hwan Kim;Ji Seong Kim;Dong-Kyu Lee;Myung Joo Kang;Yong Seok Choi
    • Analytical Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.105-112
    • /
    • 2023
  • Lycopene, a carotenoid hydrocarbon is known to have effects on reducing cardiovascular risk factors, blood lipids, and blood pressure. Thus, a lot of supplementary foods with lycopene in several dosage forms like soft capsule filled with liquid and hard capsule filled with powder are available in a market. Recently, however, our research group found that the lycopene assay in Supplementary Food Code of South Korea is only valid for oily lycopene preparation. Thus, here, we developed a simple method to determine lycopene in solid preparations for Supplementary Food Code of South Korea using saponification and liquid chromatography with an absorbance detector. The method was validated following Ministry of Food and Drug Safety guidelines. All validation parameters observed in this study were within acceptable criteria of the guidelines (selectivity, linearity of r2 ≥ 0.991, lower limit of quantification of 0.0149 mg/mL, accuracy as recovery (R) between 92.70 and 97.18 %, repeatability as relative standard deviation (RSD) values of R between 0.85 and 1.59 %, and reproducibility as the RSD value of interlaboratory R of 3.70 %). Additionally, the practical sample applicability of the validated method was confirmed by accuracy between 98.81 and 101.59 % observed from its lycopene certified reference material (CRM) analyses. Therefore, the present method could contribute to fortify the supplementary food safety management system in South Korea.

Determination of Ceftiofur in Bovine Serum by liquid Chromatography-Electrospray Mass Spectrometry (액체크로마토그래프/질량분석기를 이용한 소의 혈청 중 Ceftiofur의 분석)

  • Lim, Jong-hwan;Jang, Beon-su;Park, Byung-kwon;Yun, Hyo-in
    • Korean Journal of Veterinary Research
    • /
    • v.43 no.3
    • /
    • pp.429-433
    • /
    • 2003
  • This study was aimed to develop a more rapid, simple and sensitive method to determine ceftiofur in bovine serum using LC/MS with electrospray interface. Separation was achieved on the Nova-Pak $C_{18}$ reverse phase column. The mobile phase consisted of 0.1% acetic add in water (A) and acetonitrile (B) and gradiently flowed at the rate of 0.4 mL/min. As a result of analysis of blank muscle samples, matrix interference was not shown. Limit of detection and limit of quantitaion was 5 ng/g and 20 ng/g, respectively. The values of precision and recovery satisfied the guideline of NVRQS. The precision and recovery developed in this method are suitable and sensitive to determine the concentration of ceftiofur in the bovine serum. These results could be applied for the confirmation and quantification in the biofluid.

Method for Simultaneous Determination of Cyanotoxins in Water by LC-MS/MS (액체크로마토그래프/질량분석기를 이용한 수중 남조독소물질 동시분석법)

  • Kim, Jeong-Hee;Yun, Mi-Ae;Kim, Hak-Chul
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.4
    • /
    • pp.597-605
    • /
    • 2009
  • Algae bloom occurred in reservoir in summer can cause taste and odor in water and disturb the flocculation and sedimentation processes in water treatment plant and cause sand filter plugging. It was also reported that microcystins, anatoxin and saxitoxin released from cyanobacteria had acute toxic effects on liver and nervous system. For these reasons, many advanced countries inclusive of WHO set the guideline for these toxins and cyanotoxins have been managed with regular monitoring in Korea as well. However, complex sample preparation steps such as a solid phase extraction (SPE) and derivatization are required with an existing analysis method with HPLC. We needed to improve an analysis method for low extraction efficiency and long sample preparation time. In this study, we have established a new LC/MS/MS method which can simultaneously determine 6 cyanotoxins (Microcystins-LR, Microcystins-RR, Microcystins-YR, Anatoxin-a, Saxitoxin, Neosaxitoxin) with only simple filtration step. When $75{\mu}L$ filterated sample was injected onto the LC-MS/MS, the recovery ranged from 86% to 112% and the MDL was $0.025{\sim}0.581{\mu}g/L$. We can make the MDL be lower than the guideline ($1{\sim}3{\mu}g/L$) of advanced countries with simple preparation.

Residue Depletion of the Sulfaquinoxaline and Trimethoprim Combination in Broilers (육계에서 설파퀴녹살린 및 트리메토프림 합제의 잔류분석)

  • Lim, Jong-Hwan;Hwang, Youn-Hwan;Kim, Myoung-Seok;Song, In-Bae;Park, Byung-Kwon;Yun, Hyo-In
    • Journal of Veterinary Clinics
    • /
    • v.27 no.5
    • /
    • pp.565-568
    • /
    • 2010
  • Sulfaquinoxaline (SQX) and trimethoprim (TMP) are chemotherapeutics that are extensively used in various animal species for the treatment or prevention of coccidia and coccidia-like parasites. Little information about the depletion kinetics of these compounds in chickens exists in the literature. In this study, a new commercial liquid concentrate of SQX in combination with TMP (100 g/l of SQX and 33.4 g/l of TMP) was administered with drinking water at a dose of 0.75 ml/l or 1.5 ml/l. The edible tissue concentrations of the drugs were determined by the validated high-performance liquid chromatography/mass spectrometric method. Residue concentrations of SQX and TMP were lower than their maximum residual limits (MRLs) in all tissues from both dose groups at 5 days after the treatment. The optimal withdrawal time of SQX/TMP combination was suggested to be over 5 days after cessation of medication in broilers.

Identification of Pitfalls Related to the Analysis of Liquid Chromatography-Tandem Mass Spectrometry and Liquid Chromatography-Time of Flight Mass Spectrometry (액체크로마토그래프-질량분석기를 이용한 정성 및 정량 오류의 확인)

  • Kwon, Jin-Wook;Cho, Yoon-Jae;Rhee, Gyu-Seek
    • Korean Journal of Environmental Agriculture
    • /
    • v.34 no.3
    • /
    • pp.230-237
    • /
    • 2015
  • BACKGROUND: To identify the sources of inaccuracy in LC/MS/MS methods used in the routine quantitation of small molecules are described and discussed. METHODS AND RESULTS: Various UPLC coupled to triple quadrupole mass spectrometer and time of flight (TOF) were used to identify the potential sources of inaccuracy and inducing the pitfalls of qualification and quntitation during the veterinary drug residue analysis. Some of stable isotope labelled veterinary drugs, which were used as internal standards, presented "cross-talk", regardless of manufactures of mass spectrometer and types of spectrometer. Group of sulfonamides also presented inaccuracy qualification and quantitation due to the multi-residue analytical method with the same fragment ions at the close retention times. CONCLUSION: The phenomena of "cross-talk" occurring between subsequently monitored transition from stable isotope labelled and isotope non-labelled authentic chemical were identified. To prevent errors and achieve more accurate data during the analysis of small molecules by LC/MS/MS SRM method, Followings should be taken care of and kept checking; purity and concentration of stable isotope as an internal standard, prevention of carry-over during the separation in column, minimizing the ion suppression by matrix effect, identification of retention time, precursor ion and product ion, and full knowledge of data processing including smoothing and peak integration.

Development of an Analytical Method for the Determination of Pyriofenone residue in Agricultural Products using HPLC-UVD (HPLC-UVD를 이용한 농산물 중 살균제 pyriofenone 분석법 확립)

  • Park, Hyejin;Kim, HeeJung;Do, Jung-Ah;Kwon, Ji-Eun;Yoon, Ji-Young;Lee, Ji-Young;Chang, Moon-Ik;Rhee, Gyu-Seek
    • The Korean Journal of Pesticide Science
    • /
    • v.18 no.2
    • /
    • pp.79-87
    • /
    • 2014
  • Pyriofenone is an aryl phenyl ketone fungicide that is newly registered in Korea in 2013 to control powdery mildew on food. The objective of this study was to develop reliable and sensitive analytical method for determination of pyriofenone residue in agricultural products for ensuring the food safety. The pyriofenone residues in all samples(Korean melon, pepper, potato, mandarin, soybean, and hulled rice) were extracted with acetonitrile, partitioned with dichloromethane, and then purified with a silica cartridge. The purified samples were analyzed by HPLC-UVD and confirmed with LC-MS. The linear range of pyriofenone was 0.05~5 mg/kg with the correlation coefficient ($r^2$) > 0.999. Average recoveries of pyriofenone ranged from 72.8% to 99.5% at the spiked level of 0.05 and 0.5 mg/kg, while the relative standard deviation was 2.3%~6.4%. In addition, the limit of detection and limit of quantification were 0.01 and 0.05 mg/kg, respectively. The results revealed that the developed and validated analytical method was suitable for pyriofenone determination in agricultural products.

Pharmacomkinetics of Roxithromycin after Intravenous Administration in Broilers (록시스로마이신의 정맥주사 후 육계에서의 약물동태학적 분석)

  • Lim Jong-Hwan;Park Byung-Kwon;Kim Myoung-Seok;Hwang Youn-Hwan;Yun Hyo-In
    • Journal of Veterinary Clinics
    • /
    • v.23 no.2
    • /
    • pp.87-90
    • /
    • 2006
  • The aim of the present study was to investigate the disposition pharmacokinetics of roxithromycin in broilers. Roxithromycin was administered at a single dose of 20 mg/kg body weight by intravenous (i.v.) routes. Plasma concentrations of roxithromycin were determined by liquid chromatography/mass spectrometry. After a single i.v. dose plasma concentrations were best fitted to a two-compartment open model. The values of the pharmacokinetic parameters after i.v. administration were: elimination half-life = $5.83{\pm}1.79h$, mean residence time = $6.33{\pm}0.32h$, total body clearance = $0.55{\pm}0.15L/h/kg$, and volume of distribution at steady state = $3.47{\pm}0.84L/kg$. The pharmacokinetic interpretation of roxithromycin after i.v. administration revealed that the drug was well distributed throughout the body in broilers and slowly eliminated. More studies for the application of roxithromycin against poultry disease are needed to establish a suitable pharmaceutical formulation, propose optimum dosage regimens, investigate clinical efficacy and study the tolerability of repeated doses.

Determination of phenol using solid-phase extraction and HPLC/MSD/FLD in water (고체상추출법과 HPLC/MSD/FLD를 이용한 수질중의 페놀 분석)

  • Lee, Taejoon;Park, Keun-Young;Pyo, Dongjin
    • Analytical Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.370-376
    • /
    • 2015
  • An analytical method for determining phenol considered priority pollutants of the US EPA and precursor of toxic phenolic compounds by solid-phase extraction (SPE) and high performance liquid chromatographic systems (HPLC) equipped with fluorescence and mass selective detectors have been developed. The SPE process for sample preconcentration was performed on a commercially available Oasis HLB cartridge packed with polymeric sorbents. The effect of pH, elution solvent, and elution volume on the recoveries of the analytes were investigated with HPLC/FLD. Average recovery of >87.0% was achieved with 60 mg sorbents using 5 mL of methanol as an elution solvent at pH=3.