• Title/Summary/Keyword: 암모니아성 질소 제거

Search Result 200, Processing Time 0.02 seconds

Removal of Low Concentration Ammonia Nitrogen using a Packed Bed Bioreactor Immobilized with Nitrifier Consortium (질화세균을 고정화한 충전층 생물반응기에서 저농도 암모니아성 질소 제거)

  • Lee, Chang-Keun;Kim, Byong-Jin;Lee, Min-Su;Kim, Yong-Ha;Suh, Kuen-Hack
    • Clean Technology
    • /
    • v.13 no.1 s.36
    • /
    • pp.16-21
    • /
    • 2007
  • This study estimated the effect of hydraulic residence time(HRT), influent total ammonia nitrogen(TAN) concentration, temperature and pH in the packed-bed bioreactor using immobilized nitrifiers. Removal rate of ammonia nitrogen was increased with decreasing HRT and the optimum HRT was 0.2 hour when influent TAN was $2g/m^3$. At this point, removal rate was $226.1\;g/m^3{\cdot}day$ and removal efficiency was 88.8%. Removal rate of ammonia nitrogen was Increased with increasing TAN concentration. Removal rate and efficiency of ammonia nitrogen were kept constant at $20{\sim}35^{\circ}C$ and pH $8{\sim}9$ value.

  • PDF

A Basic Study on the Simultaneous Removal of Ammonium and Nitrate using Zeocarbon (제오카본을 이용한 암모니아성 질소와 질산성 질소 동시 제거에 관한 기초 연구)

  • Kim, Seo-A;Hong, Ji-Sook;Suh, Jeong-Kwon;Kang, Ho;Lee, Jung-Min
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.1
    • /
    • pp.109-114
    • /
    • 2005
  • The objective of this study is to investigate the possibility for water treatment, and to evaluate the efficiency of simultaneous removal of ammonium and nitrate by the surface modified zeocarbon. The surface modification was done by acid treatment using HCl. As a result of modification, strength of the modified zeocarbon was enhanced about 62% higher than that of in original one. This indicates that the modified zeocarbon was suitable for the application of water treatment. In the removal experiments of ammonium and nitrate, the removal efficiency showed about two times higher in the modified zeocarbon and the dependences of pH and temperature were found to be minimized. This indicates that the modified zeocarbon was effective for simultaneous removal of ammonium and nitrate from aqueous solution. Consequently, our results could be used as basic data to design of one-stage ammonium/nitrate simultaneous removal system.

Recycling Water Treatment of Aquaculture by Using Three Phase Fluidized Bed Reactor (삼상유동층 반응기를 이용한 양어장 순환수 처리에 관한 연구)

  • LEE Byung-hun;KIM Jeong-sook;KANG Im-suk
    • Journal of Aquaculture
    • /
    • v.7 no.3
    • /
    • pp.177-187
    • /
    • 1994
  • The objective of the present study were to evaluate nitrification characteristics and determine optimum treatment conditions of three phase fluidized bed reactor for recycling water treatment of aquaculture. When the loading rates were 2.739-0.086kg $COD/m^3/day$ and 1.575-0.128kg $NH_4\;^+-N/m^3/day$, COD and ammonia removal efficiencies were $56.3-94.7\%\;and\; 67.3­92.6\%$, respectively. The maximum removal rates of COD and ammonia were 1200mg/l/day and 488mg/l/day, respectively. Ammonia removal rates were more than $90\%$ beyond 1hr HRT. The ammoniaremoval efficiency was sensitive to the variation of media concentration and air flowrate.

  • PDF

Removal of Ammonia-Nitrogen Contained in Landfill Leachate by Ammonia Stripping(I) (암모니아 탈기공정을 이용한 침출수의 암모니아성 질소제거(I))

  • Lee, Byung-Jin;Cho, Soon-Haing
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.10
    • /
    • pp.1893-1904
    • /
    • 2000
  • Nitrogen compounds are one of the major pollutants which cause eutrophication problems of the river or lake and red tides problems of the ocean. Currently available technologies for the removal of nitrogen compounds are mostly biological treatment. However, biological treatment is only effective for the wastewater which contains low concentration of nitrogen compounds. Leachate from solid waste landfill or industrial wastewater which contains high concentration of nitrogen can not be effectively treated by most of the currently available biological treatment technologies. With this connection. the objective of this study is to examine the applicability of ammonia stripping technology for the removal of high concentration of ammonia nitrogen compounds of the leachate from solid waste landfill. It can be concluded that ammonia stripping technology which was placed before the biological treatment process was very effective for the removal of high concentration of ammonium compounds. The chemical cost for the ammonia stripping was 16 percent higher than MLE process, so other methods like sludge recycling are needed for the reduction of operation cost. Further details are discussed in this paper.

  • PDF

Application of Ferrate (VI) for Selective Removal of Cyanide from Plated Wastewater (도금폐수 중 시안(CN)의 선택적 제거를 위한 Ferrate (VI) 적용)

  • Yang, Seung-Hyun;Kim, Younghee
    • Clean Technology
    • /
    • v.27 no.2
    • /
    • pp.168-173
    • /
    • 2021
  • The treatment of plated wastewater is subject to various and complex processes depending on the pH, heavy metal, and cyanide content of the wastewater. Alkali chlorine treatment using NaOCl is commonly used for cyanide treatment. However, if ammonia and cyanide are present simultaneously, NaOCl is consumed excessively to treat ammonia. To solve this problem, this study investigated 1) the consumption of NaOCl according to ammonia concentration in the alkaline chlorine method and 2) whether ferrate (VI) could selectively treat the cyanide. Experiments using simulated wastewater showed that the higher the ammonia concentration, the lower the cyanide removal rate, and the linear increase in NaOCl consumption according to the ammonia concentration. Removal of cyanide using ferrate (VI) confirmed the removal of cyanide regardless of ammonia concentration. Moreover, the removal rate of ammonia was low, so it was confirmed that the ferrate (VI) selectively eliminated the cyanide. The cyanide removal efficiency of ferrate (VI) was higher with lower pH and showed more than 99% regardless of the ferrate (VI) injection amount. The actual application to plated wastewater showed a high removal ratio of over 99% when the input mole ratio of ferrate (VI) and cyanide was 1:1, consistent with the molarity of the stoichiometry reaction method, which selectively removes cyanide from actual wastewater containing ammonia and other pollutants like the result of simulated wastewater.

Ammonia Removal by using RBC in Recirculating Aquaculture System (RBC를 이용한 양어장수 암모니아 제거)

  • KIM Byong-Jin;LIM Sung-Il;SUH Kuen-Hack
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.31 no.5
    • /
    • pp.622-630
    • /
    • 1998
  • Rotating Biological Contactor (RBC) was tested for the removal of total ammonia nitrogen (TAN) by using simulated aquaculture system. RBC performance was evaluated by controlling revolution rate of disk and hydraulic residence tile (HRT). The optimum revolution rate of disk was 4 rpm, As HRT of RBC was increased, TAN removal efficiency of RBC and TAN concentration of rearing water were increased. HRT for maintaining lowest TAN concentration of rearing water was 9.5 minutes and at that condition TAN concentration of rearing tank was $1.03 g/m^3$

  • PDF

Comparison of efficiency in Mainstream ANAMMOX process for ratio of ammonium to nitrite (암모니아성 질소 대비 아질산성 질소 비율에 따른 Mainstream A NAMMOX 공정 효율 비교)

  • Gil, Kyung Ik;Lee, Da Won;Lee, Ji Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.421-421
    • /
    • 2021
  • 도시화, 산업화로 인해 하수처리장 유입하수 내 질소 농도가 증가하면서 그에 따른 부영양화 발생, 수생태계에 독성을 미치는 등의 악영향 또한 증가하게 되었다. 하수 내 고농도 질소를 처리하기 위해 1990년 초 연구가 시작되어 현재 보편적으로 사용되고 있는 생물학적 질소 제거 공정은 산소공급과 외부탄소원 보충 과정에서 상당한 비용이 소요된다. 이와 같은 문제점이 대두됨에 따라 고도의 질소 제거 공정이 요구되면서, 경제적으로 개선이 이루어져 기존의 질산화·탈질 공정보다 효율적인 혐기성 암모늄 산화 공정(ANaerobic AMMonium OXidation, ANAMMOX)이 제안되었다. ANAMMOX 공정은 혐기성 조건 아래 전자공여체와 전자수용체로써 암모니아성 질소와 아질산성 질소를 이용해 질소가스 형태로 질소를 제거하는 공정이다. 질산화·탈질 공정과 비교했을 때, 폭기과정에서의 산소요구량 감소, 외부탄소원 불필요, 질소 제거 과정 단축 등의 장점을 가진다. 본 연구는 수처리공정에서의 ANAMMOX 공정의 적용 가능성을 확인하고, 암모니아성 질소대비 아질산성 질소 비율에 따른 Mainstream ANAMMOX 공정의 효율 비교를 통해 공정의 안정성과 높은 제거효율을 확보할 수 있는 NH4+ 대비 NO2- 비율을 도출하는데 목적이 있다. 실험실 규모의 Mainstream ANAMMOX 반응조에 적용한 비율은 선행연구를 비롯한 화학양론식에서 제시된 비율을 바탕으로 산정하였다. 1.00부터 1.30의 전체적인 비율을 Initial과 Advanced 2개의 구간으로 나누어 운전한 결과, 각 구간의 NH4+ 제거효율은 각각 58~86%, 94~99%였다. NH4+ 대비 NO2- 비율이 증가함에 따라 공정의 안정성이 확보되고, NH4+ 및 총질소(TN) 제거효율이 증가하는 경향이 나타났다. 본 연구의 결과는 수처리공정에서의 안정적인 ANAMMOX 공정 적용을 유도하고, ANAMMOX 공정의 성능개선을 도모하는 연구의 기초로 활용될 수 있다.

  • PDF

Removal of Ammonium and Nitrate Nitrogens from Wastewater using Zeolite (제올라이트를 이용한 수중의 암모니아성 및 질산성 질소 제거에 관한 연구)

  • Kim, Choong Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.1
    • /
    • pp.59-63
    • /
    • 2016
  • The objective of this study lies in identifying the applicability of zeolite for the removal of wastewater ammonium and nitrate nitrogens. To this end, the author tracked adsorption variations as seen with the adsorption removal of wastewater ammonium and nitrate nitrogens. As a result, it was indicated that the maximum adsorption of zeolite acting on the adsorption removal of ammonium nitrogen would reach 120mg/g (weight of ammonium nitrogen divided by that of zeolite), and that Langmuir adsorption isotherm explained the adsorption of ammonium and nitrate nitrogens better than Freundlich adsorption isotherm. This means that zeolite makes ion exchanges with adsorbate for unilayer adsorption. It was also indicated that the removal efficiency of ammonium nitrogen with varying pH would be higher in the order of pH7 > pH5 > pH9 > pH3.

Removal Characteristic of Ammonia Nitrogen and Behavior of Nitrogen in Synthetic Wastewater Using Leclercia Adecarboxylata (Leclercia Adecarboxylata를 이용한 합성폐수의 암모니아성질소 제거특성 및 질소거동)

  • Lee, Hyun-Hee;Phae, Chae-Gun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.4
    • /
    • pp.460-465
    • /
    • 2007
  • In this study, the removal characteristic of ammonia nitrogen and behavior of nitrogen was investigated using Leclercia adecarboxylata, which was derived from the culture contaminated by ammonia nitrogen of high concentration. The method of ammonia nitrogen removal was not biological nitrification and denitrification but elimination of nutrient salt with internal synthesis of microorganisms which use ammonia nitrogen as substrate. L. adecarboxylata(one of ammonia synthesis microorganisms) was highly activated and showed the most high removal efficiency in free salt condition but the removal efficiency decreased badly in salt concentration of more than 4%. About 80 mg/L of $NH_3-N$ was mostly removed within 20 hours and 500 mg/L of $NH_3-N$ showed less then removal efficiency of 50% because carbon source was not enough. However, ammonium nitrogen concentration was decreased again when the carbon source was inserted additionally thus, ammonium nitrogen removal efficiency by L. adecarboxylata, was related to amount of carbon source. pH decreased from 8.0 to 6.36 according to growth of L. adecarboxylata. Concentration of nitrite nitrogen and nitrate nitrogen did not increase and TKN concentration showed no variation while ammonia nitrogen was removed by L. adecarboxylata. In addition to, when content of protein in organic nitrogen was measured, protein was not detected at the beginning of microorganism synthesis but protein of 193.1 mg/L was detected after 48 hours. Hence, ammonium nitrogen was not decomposed as nitrate nitrogen and nitrite nitrogen but synthesized by L. adecarboxylata, which has excellent ability of nitrogen synthesis and can threat ammonia nitrogen of high concentration in wastewater.

A Study on the Reduction of COD, Total Phosphorus and Nitrogen in Wastewater by Electrolysis and HClO Treatment (전기화학처리와 HClO 처리를 통한 폐수중 COD, 총인, 총질소의 저감에 대한 연구)

  • Kim, Tae Kyeong;Song, Ju Yeong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.3
    • /
    • pp.436-442
    • /
    • 2017
  • This study was conducted to develop a wastewater treatment system to remove organic matter, nitrate nitrogen, and phosphate ion in synthetic wastewater. COD was removed almost 100% by the oxidation reaction of HClO and nitrate nitrogen was reduced to ammonia by electrolysis treatment, but ammonia was reoxidized into nitrate nitrogen by HClO treatment. Ammonia was removed almost 100% by heating evaporation and no ammonia was reoxidized into nitrate by HClO treatment. Phosphate ion could be removed by precipitation treatment by forming metal complex according to pH. Through electrolysis treatment and HClO treatment, removal efficiencies of COD 99.5%, nitrogen 97.3% and phosphorus 91.5% were obtained.