• Title/Summary/Keyword: 쌍극자-쌍극자 탐사

Search Result 102, Processing Time 0.024 seconds

Detection of Groundwater Table Changes in Alluvium Using Electrical Resistivity Monitoring Method (전기비저항 모니터링 방법을 이용한 충적층 지하수위 변동 감지)

  • 김형수
    • The Journal of Engineering Geology
    • /
    • v.7 no.2
    • /
    • pp.139-149
    • /
    • 1997
  • Electrical resistivity monitoring methods were adopted to detect groundwater table change in alluvium. Numerical modelling test using finite element method(FEM) and field resisfivity monitoring were conducted in the study. The field monitoring data were acquired in the alluvium deposit site in Jeong-Dong Ri, Geum River where pumping test had been conducted continuously for 20 days to make artificial changes of groundwater table. The unit distance of the electrode array was 4m and 21 fixed electrodes were applied in numerical calculation and field data acquisition. "Modified Wenner" and dipole-dipole array configurations were used in the study. The models used in two-dimensional numerical test were designed on the basis of the simplifving geological model of the alluvium in Jeong Dong Ri, Geum River. Numerical test results show that the apparent resistivity pseudosections were changed in the vicinity of the pootion where groundwater table was changed. Furthermore, there are some apparent resistivity changes in the boundary between aquifer and crystalline basement rock which overlays the aquifer. The field monitoring data also give similar results which were observed in numerical tests. From the numerical test using FEM and field resistivity monitoring observations in alluvium site of Geum River, the electrical monitoring method is proved to be a useful tool for detecting groundwater behavior including groundwater table change. There are some limitations, however, in the application of the resistivity method only because the change of groundwater table does not give enough variations in the apparent resistivity pseudosections to estimate the amount of groundwater table change. For the improved detection of groundwater table changes, it is desirable to combine the resistivity method with other geophysical methods that reveal the underground image such as high-resolution seismic and/or ground penetrating radar surveys.

  • PDF

Crosshole EM 2.5D Modeling by the Extended Born Approximation (확장된 Born 근사에 의한 시추공간 전자탐사 2.5차원 모델링)

  • Cho, In-Ky;Suh, Jung-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.1 no.2
    • /
    • pp.127-135
    • /
    • 1998
  • The Born approximation is widely used for solving the complex scattering problems in electromagnetics. Approximating total internal electric field by the background field is reasonable for small material contrasts as long as scatterer is not too large and the frequency is not too high. However in many geophysical applications, moderate and high conductivity contrasts cause both real and imaginary part of internal electric field to differ greatly from background. In the extended Born approximation, which can improve the accuracy of Born approximation dramatically, the total electric field in the integral over the scattering volume is approximated by the background electric field projected to a depolarization tensor. The finite difference and elements methods are usually used in EM scattering problems with a 2D model and a 3D source, due to their capability for simulating complex subsurface conductivity distributions. The price paid for a 3D source is that many wavenumber domain solutions and their inverse Fourier transform must be computed. In these differential equation methods, all the area including homogeneous region should be discretized, which increases the number of nodes and matrix size. Therefore, the differential equation methods need a lot of computing time and large memory. In this study, EM modeling program for a 2D model and a 3D source is developed, which is based on the extended Born approximation. The solution is very fast and stable. Using the program, crosshole EM responses with a vertical magnetic dipole source are obtained and the results are compared with those of 3D integral equation solutions. The agreement between the integral equation solution and extended Born approximation is remarkable within the entire frequency range, but degrades with the increase of conductivity contrast between anomalous body and background medium. The extended Born approximation is accurate in the case conductivity contrast is lower than 1:10. Therefore, the location and conductivity of the anomalous body can be estimated effectively by the extended Born approximation although the quantitative estimate of conductivity is difficult for the case conductivity contrast is too high.

  • PDF

A Study to Estimate the Seawater Leakage Zone of the Embankment using SP and Pole-pole Array Resistivity Survey (SP 및 단극배열 전기비저항탐사를 이용한 방조제 누수지점 탐지)

  • Song Sung-Ho;Lee Kyu-Sang;Kim Jin-Ho;Jang Eui-Woong
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2000.09a
    • /
    • pp.19-40
    • /
    • 2000
  • We applied both SP monitoring and pole-pole array resistivity surveys and SP survey and dipole-dipole array resistivity survey to leakage problems in several embankments and dike, respectively, to estimate and detect the zone of leakage. The embankment is generally affected by tidal variation and has low resistivity characteristics due to the high saturation of seawater. According to this situation, SP monitoring and resistivity survey using pole-pole electrode array, which is relatively more effective to the conductive media, were carried out to delineate the leakage zones of sea water through the embankment. We checked out electrical conductivity(EC) and temperature variations along the inner part of the embankment to detect the zone of seawater leakage and found that the measured EC value agreed to that of seawater in the leakage zone and the temperature was lower than that of the vicinity of leakage zone. SP monitoring results were coincide with tidal variations at each embankment. Based on the survey results, it is concluded that both SP monitoring and the pole-pole array resistivity method are quite effective for investigation of seawater leakage zones in the embankment.

  • PDF

Application of Resistivity Technique for Identifying Cavities Near Surface in Karst Area, Muan-gun, South of Korea (무안군 카르스트 지역의 지하공동 탐지를 위한 전기비저항 탐사 기술 적용)

  • Farooq, Muhammad;Park, Sam-Gyu;Song, Young-Soo;Kim, Jung-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.4
    • /
    • pp.368-372
    • /
    • 2008
  • This study evaluates the usefulness and capability of surface electrical resistivity technique for identifying the weak zones or subsurface cavities in karst area with limestone formation. Weak zones or cavities near surface can be potentially dangerous and several problems are associated with collapse of roads or buildings accompanied by subsidence phenomena. In this paper, both two and three dimensional resistivity investigation were conducted to investigate subsidence along a road in Yongweol-ri, Muan-gun, South Korea. The results of the resistivity survey using dipole-dipole array provide a clear view of the weathered regolith, the distribution of weak zones or cavities and bedrock. Several low resistivity areas were identified and subsequent drilling led to the discovery of several weak zone or clay-filled underground cavities. The drilling results show excellent correlation with the resistivity images. It is illustrated, the ability of electrical technique to produce high resolution images of subsurface, which are useful for subsidence assessment. Also the results of this study have demonstrated that two and three dimensional electrical resistivity surveys are useful for delineating the subsidence area. Based on resistivity imaging, the map of hazardous zone has been developed.

Verification of Reinforcement with Grouting Materials in a Small Scale Reservoir Dike using Surface and Borehole Electrical Resistivity survey (지표 및 시추공 전기비저항 탐사를 중심으로)

  • Song, Sung-Ho;Yong, Hwan-Ho;Kim, Yang-Bin
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.3
    • /
    • pp.239-245
    • /
    • 2009
  • To verify the reinforcing effect of grouting materials composed of colloid cement and ordinary portland cement on the water leakage region in a small scale dike, we performed a tubecasing method and applied surface electrical resistivity survey including electrical resistivity tomography (ERT) to find resistivity variation before and after grouting. Hydraulic conductivities after grouting show 10 times lower than those of before grouting. These variation indicates that the cement grout blocks the leakage pathway effectively. As the results of dipole-dipole resistivity survey along the dike, resistivity distribution after grouting did not represent noticeable spatial variation in time. Resistivity monitoring results at the dike with vertical electrical sounding (VES) showed that the region of decreasing apparent resistivity was occupied by the grout after grouting. Predicted resistivities from the inversion of ERT data well matched with results of VES at the same regions. From the ERT using check holes to inspect the effect of grouting, we could find that the ERT is quite effective to identify spatially the grout region in a dike.

Geophysical Responses of the Yangsan Fault Zone at Eonyang Area (언양 일대 양산단층에서의 지구물리학적 반응)

  • Kwon Byung-Doo;Lee Heuisoon;Lee Choon-Ki;Park Gyesoon;Oh Seokhoon;Lee Duk Kee
    • Journal of the Korean earth science society
    • /
    • v.26 no.5
    • /
    • pp.436-442
    • /
    • 2005
  • We have performed multiple geophysical surveys comprised of gravity, magnetic and resistivity methods at the Yangsan fault zone which runs through the Eonyang area, the eastern part of Kyeongsang in southeast Korea. The gravity and magnetic data provide information about geological structures. Furthermore, sections of electrical resistivity show the sharp contrast of electrical resistivity distribution across the fault zone. Since the fractured zone tends to be more conductive than fresh host rocks, the electrical resistivity survey is effective in determining the detailed structure of the fault zone. We have made gravity measurements at a total of 71 points alongside two profiles across the fault zone, and carried out an electrical resistivity survey with a dipole-dipole array at the same location using 40m dipole length. In addition, we have analyzed the aeromagnetic data on the corresponding area. The multiple geophysical properties appear to be abruptly changed in electrical resistivity, gravity and aeromagneticclearly show the different appearance across the fault zone. The fault is identified by its sub vertical attitude which is well known in the Yangsan fault zone. We have also confirmed that the magnitude of the response of the fault is much larger in the southern part of the survey area than the northern area. These results most likely to provide basic information for the further studies about the physical properties and the structures at the Yangsan fault.

ESTIMATING THE VOLUME OF CONSTRUCTION-WASTE LANDFILL USING GEOPHYSICAL TECHNIQUES (물리탐사 기법을 이용한 건축 폐기물 매립지의 규모 파악)

  • Mun,Yun-Seop;Lee,Tae-Jong;Lee,Chae-Yeong;Yun,Jun-Gi
    • Journal of the Korean Geophysical Society
    • /
    • v.6 no.1
    • /
    • pp.13-23
    • /
    • 2003
  • Dipole-dipole resistivity and ground penetrating radar(GPR) surveys were performed on an abandoned landfill site filled with asbestos containing material. The main purpose of the study was to estimate spatial extension and volume of the landfill for evaluting the cost for developing appropriate remedial alternatives. Assuming that the bedrock is within 10 m depth, dipole spacings of 2, 2.5 and 5m were set for six survey lines for resistivity measurements. For More detailed information, GPR suvey using 225 Mhz antenna was carried out for twelve survey lines for the shallower information. DC resistivity structures showed few tens ~ hundreds ohm-m for the landfill or alluvial laver, and 1,000~ 5,000 ohm-m for the bedrock. The depth to bedrock is found out to be approximately 5m. GPR survey results represented very clear reflection and/or diffraction events from the boundaries as well as from the blocky construction wastes. With high-resolution GPR survey, depth of the bedrock was resolved up to 2m, which in turn, could be a good indicator for estimating the volume of the landfill. Those depths of bedrock were confirmed by backhoe excavation data for 13 sites. The total area and volume of the landfill were to be approximately 3,953 .$m^2$ and 4,033 $m^3$, respectively.

  • PDF

Investigation of fault in the Kyungju Kaekok-ri area by 2-D Electrical Resistivity Survey (2차원 전기비저항 탐사를 이용한 경주 개곡리 지역의 단층조사)

  • Lee, Chi-Seop;Kim, Hee-Joon;Kong, Young-Sae;Lee, Jung-Mo;Chang, Tae-Woo
    • Geophysics and Geophysical Exploration
    • /
    • v.4 no.4
    • /
    • pp.124-132
    • /
    • 2001
  • Electrical resistivity survey has been conducted for delineating geological fault structure in Kaekok-ri near Kyungju. In general, electrical resistivity survey has an advantage of searching buried faults and its traces compared with other geophysical survey methods. Distribution of electrical conductivity in the ground is influenced by the ratio of pores, groundwater and clay minerals. These properties are evidenced indirectly to explain for weathering condition, faults and fracture Bones. Thus the electrical resistivity survey can be an effective method to find buried faults. We have carried out two dimensional (2-D) interpretation by means of smoothness-constrained least-squares and finite element method. Field data used in this paper was acquired at Kaekok-ri, Wuedong-eup, Kyungju-si, where is Ulsan Fault and is close to the region in which debatable quaternary fault traces were found recently. The dipole-dipole array resistivity survey which could show the 2-D subsurface electrical resistivity structure, was carried out in the area with three lines. The results showed good property of fault, fracture zone and fault traces which we estimated were congruous with the results. Through this study, 2-D electrical resistivity survey interpretation for fault is useful to apply.

  • PDF

Environmental Geophysical Survey of Abandoned Landfills for Contamination Evaluation: A Case Study (불량 매립지 오염평가를 위한 지구물리 탐사 사례연구)

  • Lee, Sung-Soon;Lee, Jin-Yong;Yoon, Hee-Sung;Lee, Kang-Kun;Kim, Chang-Gyun;Yu, Young-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.5
    • /
    • pp.463-471
    • /
    • 2006
  • Electrical resistivity surveys were conducted at areas of abandoned landfills in Cheonan and Wonju. Geology and extent of leachate migration around the landfills were evaluated with collected resistivity data by 2-D and 3-D resistivity inverse modeling. The Cheonan landfill is located above the paddy fields and the resistivity survey lines were crossed to examine possible pollution at the paddy fields by leakage of the landfill leachate. In Wonju, the landfill and the downgradient paddy fields are divided by a concrete barrier wall. At the bottom of the landfill, there is a leachate settlement system, which has not been in operation. To evaluate leachate leakage into the paddy fields, a total of 4 survey lines were used. According to the resistivity survey results, the landfill leachate in Cheonan appeared to be restricted only within the interior of the landfill, not to migrate into the subsurface of the paddy fields. These results are well consistent with electrical conductivity values of groundwaters obtained from a periodic analysis of water qualities. In Wonju, however, it was inferred that the leachate emanating from the landfill migrated beneath the abandoned leachate settlement system and the leachate would reach the downgradient paddy fields. Low resistivity area was observed in the old reservoir area and it appeared to be derived from convergence of groundwater flows from the surrounding valley and the moist wet land. In addition, groundwater flow into the paddy fields occurs beneath the old reservoir embankment at depths of $7{\sim}8m$. This paper reports details of the resistivity surveys for the uncontrolled landfills.

Delineation of the Slip Weak Zone of Land Creeping with Integrated Geophysical Methods and Slope Stability Analysis (복합 지구물리탐사와 사면 안정해석 자료를 이용한 땅밀림 지역의 활동연약대 파악)

  • Lee, Sun-Joong;Kim, Ji-Soo;Kim, Kwan-Soo;Kwon, Il-Ryong
    • The Journal of Engineering Geology
    • /
    • v.30 no.3
    • /
    • pp.289-302
    • /
    • 2020
  • To determine the shallow subsurface structure and sliding surface of land creeping in 2016 at Hadong-gun, Gyeongsangnam-do, geophysical surveys (electric resistivity, and refraction seismic methods, borehole televiewer) and slope stability analysis were conducted. The subsurface structure delineated with borehole lithologies and seismic velocity structures provided the information that the sediment layer on the top of the slope was rather as thick as 20 m and the underlying weathered rock (anorthosite) was thinner than 1 m. Based on the tension cracks observed during the geological mapping, televiewer scanning was performed at the borehole BH-2 and detected the intensive fracture zones at the ground-water level, associated with the slip weak zones mapped in dipole-dipole electrical resistivity section. Downslope sliding and slightly upward pushing at the apex of high resistive bedrock explains the curved slip plane of the land creeping. Such a convex structure might play a role of natural toe abutment for preventing the downward development of slip weak zones. In slope stability analysis, the safety factors of the slip weak zone are calculated with varying the groundwater levels for dry and rainy seasons and the downslope is founded to be unstable with safety factor of 0.89 due to fully saturated material in rainy season.