• Title/Summary/Keyword: 실증설비

Search Result 336, Processing Time 0.026 seconds

A Study on the Optimization of District Heating and Cooling Facilities (지역냉난방사업의 설비 최적화에 관한 연구)

  • Kim, Jin Hyung;Choi, Byung Ryeal
    • Environmental and Resource Economics Review
    • /
    • v.15 no.3
    • /
    • pp.505-530
    • /
    • 2006
  • For the district heating and cooling business, it is required to install energy-saving facilities using energy from waste and land fill gases such as combined heat and power(CHP). The current issues that this business faces can be summarized as below: which facilities including CHP can be economically introduced and how much of their capacities should be. Most of such issues are clearly related to the optimal plant design of the district heating and cooling business, and the prices of energy services such as heating and cooling energy, and electricity. The purpose of this study is to establish linear program model of least cost function and to practice the empirical test on a assumed district heating and cooling business area. The model could choose the optimal type of energy-producing facilities among various kinds available such as CHP's, absorption chillers, the ice-storage system, etc. CHP with the flexible heat and power ratio is also in the set of available technologies. And the model show us the optimal ration of heat producing facilities between CHP and historical heat only boiler in the service area. Some implications of this study are summarized as below. Firms may utilize this model as a tool for the analysis of their optimal size of the facilities and operation. Also, the government may refer the results to regulate resonable size of business.

  • PDF

An Effective Installation Method of lightning Protective Devices for Information and Communication Facilities (정보통신설비용 뇌서지 보호장치의 효과적인 설치기법)

  • 이복희;이동문;강성만;엄주홍;이승칠
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.5
    • /
    • pp.90-96
    • /
    • 2002
  • The AC power lines and signal lines of info-communication networks are muted on overhead poles and are exposed to lightning strikes. Due to the potential difference between groundings of the AC power lines and telecommunication lines, the electronic equipments connected to the telecommunication lines can easily be damaged by lightning surges. In this work, in order to develop the reliable ways to protect information and communication facilities from lightning surges, the reliability and performance of surge protective devices were experimentally investigated in actual-sized test circuit. The operation behaviors of surge protective devices against lightning surges from the AC power lines and telecommunication lines and the coordination effects of SPD installation method were evaluated. As a consequence, it was confirmed that the bypass arrester and common grounding system is very effective.

Structural Model of Electricity Market for Forecasting the Market Price (전력시장가격 예측을 위한 구조적 모델링)

  • Kang Dong Joo;Jung Hae Sung;Hur Jin;Kim Tae Hyun;Moon Young Hwan;Jung Ku Hyung;Kim Bal Ho
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.648-651
    • /
    • 2004
  • 현재 원가반영발전경쟁시장(CBP : Cost Based Pool)에서는 발전사업자의 변동비용에 기초하여 공급곡선을 형성하게 된다. 그래서 공급 곡선에 있어서 는 비교적 불확실성이 덜하다고 할 수 있다. 그러나 양방향입찰시장에서의 가격결정은 발전사업자와 전력구매자의 입찰데이터(bidding data)로 결정되므로 불확실성의 정도가 매우 심해진다. 즉 가격결정에 있어서 입찰데이터는 매우 중요하며 입찰전략에 따라 사업자의 수익이 달라지기 때문이다. 또한 수직통합체제 때와는 달리 설비용량의 증설도 계통의 부하를 충족시키기 위해서가 아니라 각 발전사업자의 수익성을 고려하여 수행된다. 따라서 중장기적으로는 설비용량계획의 불확실성이 존재하고 단기적으로는 각 발전사업자의 수익 극대화를 위한 입찰 전략에 있어서의 불확실성이 존재하게 된다. 이와 같은 상황에서는 과거의 역사적 데이터를 바탕으로 해당시장에서 발전사업자들의 형태를 분석하는 실증적 분석(empirical analysis)이 가장 설득력이 있지만 현재 우리나라의 전력 시장은 CBP 체제이고 TWBP 시장은 열리지도 않았기 때문에 축적된 데이터는 전무하다. 이러한 현실적 여건 때문에 불확실성의 정도는 더욱 심해지고 TWBP 시장에서의 가격을 예측하는 과정에서도 어려움이 더욱 커지게 된다. 따라서 본 연구에서는 가능한 다양한 해외 연구 사례를 참조하여 시장에서의 발전사업자 중장기적(설비), 단기적(입찰전략) 행위를 어떤식으로 모델링하고 시장가격과 어떤 식으로 연결되는지를 분석해보고자 한다.

  • PDF

A Customized Cleaning Agent for the Maintenance of Electric Fume Collector Used for the Purification of Effluent Gas from the Textile Industry (섬유산업 배기가스 정화용 Electric Fume Collector 설비의 유지보수를 위한 맞춤형 세정제)

  • Kim, Hotae;Yoo, Hwang-Yooll;Jeon, Koung Min;Song, Doori;Kim, Jin-Bae
    • Applied Chemistry for Engineering
    • /
    • v.29 no.2
    • /
    • pp.229-236
    • /
    • 2018
  • A customized cleaning agent was investigated for improving the performance decreased by the pollution of collecting plates in an electric fume collector (EFC) which was developed and applied for the purification of effluent gas including oil mist from the textile industry. The pollutants on the surface of collecting plates were blackened by the condensation of oil mist for a long time and difficult to remove by general cleaning agents. The composition of an optimized cleaning agent consisted of alkali, alcohol, glycol and non-ionic surfactant sources was determined by considering the pollutant properties and effect on the damage of the basic metal of collecting plate and so on. The developed cleaning agent solution diluted by 9.1% was applied to the field test, and also the pollutants strongly adhered on collecting plate surfaces were successfully removed by a simple spraying method. The effluent gas purification efficiency of EFC increased significantly by cleaning of collecting plates.

Estimation of the Optimal Generation Capacity of Solar-Wind Hybrid Power System for Economic Operations (태양광-풍력 복합발전시스템의 경제적 운용을 위한 최적 용량 산정에 관한 연구)

  • Lee, Seung-Chul;Moon, Un-Chul;Kwon, Byeong-Gook;Kim, Jong-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.156-162
    • /
    • 2004
  • In this paper, a technique that estimate the optimal capacity of the solar-wind hybrid power system for minimizing the total monthly electric power expenses is presented. The hybrid power system is assumed to be operated in connection with the utility power system and electric bill be paid for the power not covered by the hybrid system generation. Monthly generation cost is estimated based on total life-cycle cost analysis. The monthly utility power bill is assumed to be increased quadratically in proportion with the net utility power consumption which is the difference between the total monthly load minus the hybrid system generations. Test results demonstrate applications potential of the proposed technique.

Surge Protection Method of the Underground Distribution System in Korea (국내 지중배전시스템의 서어지 보호방안)

  • Lee, Jae-Bong;Jung, Yeon-Ha;Park, Chul-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.84-88
    • /
    • 2008
  • This paper deals with the part of the surge protection method of the underground distribution system in Korea using arrestors by simulating with ATP-EMTP(Electro-Magnetic Transient Program) based on the "A Study on the Surge Propagation Property of Underground Distribution Cables by Field Tests" which was published in 2007. Although domestic underground distribution system is protected by arrester which installed at a riser pole, we need to additional protection method because lightning surge can be doubled and affect underground distribution facilities when it is injected into the mixed distribution line of overhead and underground through a riser pole. In this paper, it is proposed that scout method that arresters are attached to the sides of a riser pole is better than developing of a elbow arrester on a viewpoint of economics and maintenance, because of the situation of the domestic underground distribution system.

Empirical Study to Strengthen the Disaster Management of Wooden Cultural Heritage - Focused on Concept and Range of Cultural Heritage Disaster Management and Investigation of On-site Manager (목조문화재의 안전관리 강화를 위한 실증적 연구 - 문화재 안전관리의 개념과 범주 및 현장 관리자 의식조사를 중심으로 -)

  • Lim, Suhng-bin;Ryu, Ho-cheol
    • Korean Journal of Heritage: History & Science
    • /
    • v.46 no.2
    • /
    • pp.96-113
    • /
    • 2013
  • The concept of disaster management of cultural heritage is not clearly established and the range and type of it is not organized yet. Also, there is an ever-present danger in the field control because there is no system that can provide safety of cultural heritage from various dangerous factors. Concretely, institutionally, the regulation of disaster management of cultural heritage remains limited and there are not enough reasonableness in installation and management of fire-fighting equipment and safety equipment. Also, we need to take an action to secure the safety of cultural heritage from its surroundings. In this research, we setup the concept, type and criteria for disaster management of cultural heritage to overcome limitations and problems of management of cultural heritage. In addition, in order to raise the level of disaster management of cultural heritage, this research proposes direction to reinforce the disaster management of cultural heritage by investigating and analyzing consciousness of security guards and fire-fighting officers.

Demonstration Study on Ammonia Stripping in Electronic Industry Wastewater with High Concentrations of Ammonia Nitrogen (고농도 암모니아를 함유한 전자 폐수의 암모니아 탈기 실증 연구)

  • Jae Hyun Son;Younghee Kim
    • Clean Technology
    • /
    • v.29 no.4
    • /
    • pp.297-304
    • /
    • 2023
  • The rapid advancement of the high-tech electronics industry has led to a significant increase in high-concentration ammonia wastewater. Various methods have been attempted to reliably treat wastewater containing high concentrations of ammonia, but no successful technology has yet been developed and applied. In this study, the removal efficiency and characteristics of ammonia nitrogen was evaluated according to changes in temperature, air loading rate, and liquid loading rate using a closed circulation countercurrent packed tower type demonstration facility for wastewater containing high concentrations of ammonia generated in the high-tech electronics industry. The temperature was varied while maintaining operating conditions of a wastewater flowrate of 20.8 m3 h-1 and an air flow rate of 18,000 Nm3 h-1. The results showed that at temperatures of 45,50,55, and 60℃, the removal efficiencies of ammonia nitrogen (NH3-N) were 87.5%, 93.4%, 96.8%, and 98.7%, respectively. It was observed that temperature had the most significant impact on the removal efficiency of NH3-N under these conditions. As the air loading rate increases, the removal rate also increases, but the increase in removal efficiency is not significant because droplets from the absorption tower flow into the stripping tower. Even if the liquid loading rate was changed by ±30%, the removal rate did not change significantly. This does not mean that the removal rate was unaffected, but was believed to be due to the relatively high air load rate. Through demonstration research, it was confirmed that ammonia stripping is a reliable technology that can stably treat high-concentration ammonia wastewater generated in the high-tech electronics industry.

A Method for Simulation of Smart Grid Communication Network Architecture (스마트 그리드용 통신망 아키텍처 시뮬레이션 방법)

  • Kim, Youngsun;Oh, Hui-Myoung;Choi, Sungsoo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.2
    • /
    • pp.122-129
    • /
    • 2013
  • This paper shows the method for simulating the two-way communication network to transmit information in Smart Grid, which is currently investigated by many researchers. The simulation method can be basically applied to analysis of data traffic for various electric devices such as smart meters, which were tested in Jeju island and massively deployed with nationwide scale.

Positive Research About Water Aeration Improvement to Break Thermal Stratification of Dam (댐내 수온성층 파괴를 위한 산기식 수중폭기설비 성능향상 실증연구)

  • Park, Jong-Ho;Ra, Beyong-Pil
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.5
    • /
    • pp.37-42
    • /
    • 2014
  • In Korea while the dam or reservoir is an important water resource, the value of this water resource is deteriorating by thermal-induced stratification. To ameliorate the water quality of reservoir by breaking stratification the use of air diffuser system is now widespread in Korea. According to the previous research, dynamics of bubble plume and destratification efficiency depended upon two dimensionless groupings; Mh and Pn suggested by Asaeda et al (1993). However, these two variables only include Q, N, H, g, u. and installed Boryeong reservior in appropriate width of water aeration, air dose and number of installations after calculating by applying these figures. This paper is performed to find out effect analysis about water aeration improvement to break thermal stratification.