• 제목/요약/키워드: 실증설비

검색결과 336건 처리시간 0.028초

배전 실증시험장 시스템 현황 소개 (Introduction of the field - test evaluation system in KEPCO)

  • 김동명;최선규;장상옥;오재형
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.81-85
    • /
    • 2004
  • This paper describes the testing facility to demonstrate the performance of the distribution class circuit breakers and switchgears and the testing methods. The field-test evaluation system consists of two parts. One is the distribution system for simulation of the condition on interruption mode of switches which are installed in the system and tested by the AFG(Artificial Fault Generator) and the thunderbolt generator just like in the real field. The other is a laboratory for confirmation or the important characteristics regarding to the insulation, gas, environment durability of equipment. For the fatal failure mode, a FMEA(Failure Modes and Effects Analysis) technique which is a kind of a structural analysis to consider a counter-plan was emploved.

  • PDF

송전용 애자의 장기실증시험 분석 (A Characteristic analysis of EHV insulators on long-term outdoor tests)

  • 최인혁;최장현;정윤환;이동일
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.392-396
    • /
    • 2004
  • Experimental equipments for long-term outdoor tests of EHV insulators in outdoor were constructed. The testing insulators have been energized with 89 [kV] phase-to-ground AC voltage under identical condition at station, and the investigation was carried out for leakage current and various environments such as temperature, relative humidity and wind velocity. The test results of leakage current wave trends have forms on distorted waves including harmonics. The porcelain and glass insulators have low leakage current in case of daytime because moisture and humidity have relative low values. In comparison with these conditions, high leakage current was shown at dawn and rainy day due to high humidity. However, leakage current of polymer insulators was shown approximately $129[{\mu}m]$ without relation to the weather due to hydrophobicity on their surface.

  • PDF

풍력기반의 하이브리드 발전시스템의 실증연구 (The Demonstration Research on Hybrid Power Generation System Based on Wind Power)

  • 안재영;이화춘;송성근;이상훈;조수억;박성준;김광헌
    • 조명전기설비학회논문지
    • /
    • 제24권10호
    • /
    • pp.106-113
    • /
    • 2010
  • In this paper, the empirical study for a hybrid generation system based on wind power which is leading renewable energy was performed. The simulation for the overall operation of the wind generator, diesel generators, monitoring system and a central controller operated in Demonstration Complex was carried out. In addition, the adequacy of the control algorithm was examined through the experiments.

해외 노후 소수력 발전소 현대화 개발 및 실증 (Development of Modernization for Overseas Old Small Hydro Power Plants)

  • 김운학;강석원
    • 한국재난정보학회:학술대회논문집
    • /
    • 한국재난정보학회 2017년 정기학술대회
    • /
    • pp.235-236
    • /
    • 2017
  • 소수력발전소가 건설 후 점검 및 유지보수를 지속적으로 수행 설비성능을 유지하지만, 30년이 경과하면 노후화 및 피로현상으로 성능이 저하되고 경제적 내용연수가 도래한다. 대수력의 경우 전문인력과 점검 및 보수비용을 투자하여 일상, 주간, 월간, 년간, 정기보수를 수행하고 그 기록을 유지관리하고 있지만, 소수력발전소의 경우는 그러하지 못하여 발전소 효율뿐만 아니라 운용중의 안전도 위협받고 있는 상황이다. 본 논문에서는 국내 시설물 안전관리에 관한 특별법에 의거 필리핀에 위치한 노후 수력발전소의 현대화를 위하여 최초 기존 시설물에 대한 안전진단을 실시하여 토목 및 건축물의 보강을 위한 방법을 선정하고 이를 바탕으로 수력발전설비로부터 발생하는 진동과 같은 다양한 영향을 감소시키기 위한 토목기술을 반영하여 현지 환경에 적합한 수차선정과 노후 시설물의 유지보수를 국내 토목 보수 보강 기술로 설계하였다.

  • PDF

현장실증시험에 의한 대지저항률별 접지저항 보정계수의 결정 (The Determination of Corrective Coefficient for Ground Resistance about Variation of Soil Resistivity by Field Test)

  • 심건보;김경철;이형수;박재덕;박상만
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.288-292
    • /
    • 2006
  • Usually, equations that calculate ground resistance of earth electrode was already informed well by form of earth electrode. But, when apply on the spot because general expressions are very insufficient at point that calculate exact ground resistance value by variation of earth electrode, and constant value that corrective coefficient for ground resistance calculation is fixed regardless of change of the earth resistivity specially is presented, it is actuality that difficulty is. Therefore, in this study, about these problem, proposed corrective coefficient for calculation of ground resistance according to change of the earth resistivity.

  • PDF

3㎾ 태양광발전시스템 실증연구 I (The Field Demonstration Study of Residential 3㎾ PV System)

  • 김형석;박정국;임홍우;조금배;백형래;최창주
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.365-367
    • /
    • 2003
  • Total six units of 3㎾ photovoltaic system and data acquisition system (DAS) are constructed for analyzing performance of PV system at field demonstration test center of Gwang-Ju in Korea. As climatic and irradiation conditions are varied. operation characteristics of the PV system are collected and analyzed in data-acquisition system furthermore, not only performance test of each PV system component such as PV module and power conditioning system but also performance of total PV system e.g. system efficiency power and loss factor at the site are reviewed.

  • PDF

Stocker 시스템에 적용한 비접촉 전원시스템의 효율 개선에 관한 연구 (A study on efficiency improvement of contactless power supply system for Stocker system)

  • 황계호;김원곤;윤종보;문인호;이봉섭
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.400-403
    • /
    • 2009
  • 최근, LCD(Liquid Crystal Display) 산업에서 클린룸의 규모가 커짐에 따라 Stocker 시스템의 사이즈가 커지고 길이가 장거리화 되고 있다. 이에 제조업체는 생산수율을 높이기 위해 Stocker 시스템의 전체 택타임을 줄이기 위한 방안으로 Stocker 시스템의 속도를 증가시키도록 요구하고 있다. 또한, 제조업체는 고유가 시대에 여러 장비들에 대한 에너지 절약을 통한 공장 운영비용이 최소화되도록 요구하고 있다. 따라서 본 논문은 차세대 Stocker 시스템의 에너지 절감과 이송 속도증가에 따른 비접촉 전원시스템의 최적설계를 제안하고, 에너지 절감을 위한 비접촉 전원시스템의 시제품을 제작하여 부하인 크레인의 여러 운전 패턴에 따른 비접촉 전원시스템의 실증시험과 입/출력 특성, 효율 개선에 따른 비접촉 전원시스템을 개발하여 에너지 절감 효과에 대하여 서술하였다.

  • PDF

빅데이터 기반 대용량 시계열 에너지 데이터 처리 시스템 (Time-series big data analytics software on IoT streaming data)

  • 강정훈;유준재
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2018년도 춘계학술발표대회
    • /
    • pp.52-53
    • /
    • 2018
  • 본 논문은 에너지 빅데이터를 분석하기 위해 대용량의 시계열 데이터를 처리하는 시스템의 설계, 구축 방법을 제시한다. 이미 사용 중인 건물이나 공장의 에너지 효율화를 위해서 정부는 효율자원 시장 지원 사업을 수행하고 있다, 에너지 소비 설비에 따라 고효율 자원으로 변경 설치하는 데 필요한 자금의 일부를 지원하고 있다. 정부지원으로 고효율 설비로 변경함에 따라 실증 사이트에서는 측정 데이터를 수집하여, 효율화 정도를 파악하기 위한 에너지 데이터 분석 시스템을 구축하여 운영하였다. 해당 측정 정보는 IoT 전력량계를 통해 수집되며, 수집된 데이터는 클라우드 시스템에서 다양한 머신러닝 알고리즘에 적용되어, 에너지 소비 효율 평가에 필요한 성능 지표를 연산한다. 구현된 진단 시스템은 기축 건물의 에너지 효율향상 상황을 분석하는데 기여할 수 있다. 빅데이터 기반의 에너지 분석 기능을 사용하여 에너지 고효율 장비의 운영시간, 부하율 등의 효율성과 성능통계를 연산할 수 있다.

주거용 건물 지열원 멀티 히트펌프시스템의 지열순환펌프 가변유량제어에 관한 실증연구 (An Experimental Study on Variable-Speed Control of an Ground-Water Circulation Pump for a Ground Source Multi-Heat Pump System)

  • 송수원
    • 설비공학논문집
    • /
    • 제25권8호
    • /
    • pp.443-449
    • /
    • 2013
  • The purpose of this study is to propose an enhanced variable-speed control method of ground-water circulation pumps using inlet and outlet ground-water temperature difference and analyze its effect for the ground source multi-heat pump system installed in a single-family house. As a result, it has shown to significantly reduce the electricity use of ground-water circulation pump and improve overall system Coefficient of Performance (COP) due to the proposed variable-speed control under partial load conditions after oversized and inefficient single-speed pump retrofit.

시뮬레이션과 실증실험을 통한 슈퍼윈도우의 성능분석 (Analysis Performance of Super Window through Simulation and Verification Experiment)

  • 백상훈;이진성;조수;장철용;성욱주;서승직
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1069-1074
    • /
    • 2006
  • Heat loss by window in building occupies about 1/4 of energy amount used building. Therefore, high thermal insulation of windows system can speak as very important part in save energy of building. in this research, After select most suitable frame design and Glazing system for high thermal insulation of windows, execute simulation of mixing frame and Glazing System. Also, manufacture windows with the result and execute verification experiment, with verified simulation, this research evaluated thermal insulation performance of window by Glazing System's change.

  • PDF