• Title/Summary/Keyword: 신.재생에너지

Search Result 4,686, Processing Time 0.033 seconds

The Comparative Analysis on Critical Planning Methods and Application Condition of Low-carbon Green City (저탄소 녹색도시의 주요 계획기법과 적용실태 비교분석)

  • Jeon, Woo-Seon;Lee, Eunghyun;Oh, Deog-Seong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.2491-2502
    • /
    • 2014
  • The main objective of this study is to find out the main fields and methods to create a low carbon green city. Through the findings, we hope to figure out the matters that must be focused on in order to realize a low carbon green city. In order to accomplish this, we organized the main fields and methods of fulfilling this accomplishment by taking a look at recorded documents and past studies related to the creation of low carbon green cities and related concepts. Then a FGI analysis was performed in order to examine suitability and deduct a planning technique. Also, through professional surveys and AHP analysis, we figured out the importance of planning techniques to understand the main characteristics of planning a low carbon green city. We also selected domestic and foreign cases, analysed the actual conditions of applying the deducted planning techniques, and compared the importance of planning techniques in order to see the difference between our plans and real results. 15 planning techniques were deducted and divided into 5 groups. The importance analysis and case analysis showed the following to be the main elements in planning the creation of a low carbon green city: compact high-density development, a traffic system revolving around pedestrians, active utilization of new and renewable energy, and establishment of a recycling system for waste.

Using the Binomial Option Pricing Model for Strategic Sales of CER's to Improve the Economic Feasibility of CDM projects (이항옵션가격 모형을 활용한 CER 판매전략 구축과 이를 통한 CDM 사업 수익성 향상 방안에 관한 연구)

  • Koo, Bonsang;Park, Jong-Ho;Kim, Cheong-Woon
    • Korean Journal of Construction Engineering and Management
    • /
    • v.15 no.1
    • /
    • pp.111-121
    • /
    • 2014
  • The Clean Development Mechanism (CDM) allows New & Renewable Energy projects to make additional income by selling CER's, which represent the amount of Green House Gases(GHG) that is reduced in the project. However, forward contracts used to hedge fluctuating market prices does not allow projects to sell CER's at a premium. As an alternate approach to maximize CER revenue, CER's are modeled as a 'real option', in which CER's are sold only above the desired sales price. Using the Binomial Option Pricing model, the resultant lattices are used to determine whether to sell, defer or abandon the option at individual nodes. Overlaying Pascal's Triangle on the lattices also enabled the calculation of the annual probabilities for deferring CER sales without incurring downside losses. Application to an actual Landfill Gas project showed increased overall NPV, and that CER sales could be deferred at a maximum of 2 years. The proposed framework allows transparency in the analysis and provides valuable and strategical information when making investment decisions related to CER sales of CDM projects.

Study on free and bond glycerines in Biodiesel from PKO(Palm Kernel Oil) and coconut oil (PKO 및 코코넛유래 바이오디젤 중 글리세린함량 분석 방법 개선 연구)

  • Lee, Don-Min;Park, Chun-Kyu;Ha, Jong-Han;Lee, Bong-Hee
    • Journal of the Korean Applied Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.348-361
    • /
    • 2015
  • To reduce the effects of greenhouse gas (GHG) emissions, the government has announced the special platform of technologies as parts of an effort to minimize global climate change, and the government distributed biodiesel since 2006 as the further efforts. Although there are some debates about some quality specifications and unbalanced of source (44% from palm oil), more than 400kton/year of biodiesel was produced in 2013. Moreover the amounts will be increased when the RFS is activated. To solve the unbalanced situation and to achieve the diversity of feeds, it is essential that many researches should be considered. Especially, free and bond glycerines are one of the important properties seriously affected to the combustion system in vehicle & cold properties. Previous method (KS M 2412) couldn't cover the biodiesel derived from lauric oil($C_{12:0}$) such as PKO (Palm Kernel Oil), Coconut oil because those compositions are lighter than other conventional biodiesel sources. In this study, we review the existed method and figure out the factors should improve to analysis the glycerine from PKO and Coconut oil biodiesel. Modifying the analysis conditions to enhance the resolution and change the internal standards to avoid the overlapped- peaks between Capric acid ME ($C_{10:0}$) and standard#1(1,2,4-butantriol). From this revised method, we could solve the restrictions of previous methods. And check the possibility of new method to analyze the glycerine in biodiesel regardless of sources.

Design and fabrication of a 300A class general-purpose current sensor (300A급 일반 산업용 전류센서의 설계 및 제작)

  • Park, Ju-Gyeong;Cha, Guee-Soo;Ku, Myung-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.1-8
    • /
    • 2016
  • Current sensors are used widely in the fields of current control, monitoring, and measuring. They have become more popular with the increasing demand for smart grids in a power network, generation of renewable energy, electric cars, and hybrid cars. Although open loop Hall effect current sensors have merits, such as low cost, small size, and weight, they have low accuracy. This paper describes the design and fabrication of a 300A open loop current sensor that has high accuracy and temperature performance. The core of the current sensor was calculated numerically and the signal conditioning circuits were designed using circuit analysis software. The characteristics of the manufactured open loop current sensor of 300 A class was measured at currents up to 300 A. According to the test of the current sensor, the accuracy error and linearity error were 0.75% and 0.19%, respectively. When the temperature compensation was carried out with the relevant circuit, the temperature coefficients were less than $0.012%/^{\circ}C$ at temperatures between $-25^{\circ}C$ and $85^{\circ}C$.

Removal of Volatile Organic Silicon Compounds (Siloxanes) from Landfill Gas by Adsorbents (흡착제에 의한 매립가스 중 휘발성 유기규소화합물(실록산) 제거특성)

  • Seo, Dong-Cheon;Song, Soo-Sung;Won, Jong-Choul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.9
    • /
    • pp.793-802
    • /
    • 2009
  • Adsorption properties were estimated for the organic silicon compounds (siloxanes) in an actual landfill gas (LFG) using adsorbents such as coconut activated carbon, coal activated carbon, silica gel, sulfur adsorbent, carbonized sludge, and molecular sieve 13X. Coconut activated carbon showed the highest removal efficiency of more than 95%. The desorption of hexamethyldisiloxane (L2) from the adsorbent, however, resulted in the remarkable concentration variation of the compound in the treated gas. Silica gel, which had high adsorption capacity for L2 in single substance adsorption experiment in the other study, could not remove the component in the actual landfill gas while it adsorbed well octamethylcyclotetrasiloxane (D4) and decamethylcyclopentasiloxane (D5) in the LFG. Therefore the elimination of hexamethyldisiloxane is an important factor to determine the level of total organosilicon compound in pretreated landfill gas. Moreover, the L2 from the actual landfill gas was effectively adsorbed by the serial adsorption test using two columns packed with coconut activated carbon which has the great capacity of siloxanes removal among others. In order to utilize efficiently LFG as a renewable energy, the emission and adsorptive characteristics of the substance to be treated should be considered for the organization, operation, and management of pretreatment process.

Status and Perspective of Biomass Co-firing to Pulverized Coal Power Plants (미분탄 석탄화력발전에서의 바이오매스 혼소 동향 및 전망)

  • Yang, Won
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.4
    • /
    • pp.525-529
    • /
    • 2016
  • Biomass co-firing to existing thermal power plants is one of the most economical and efficient way to reduce $CO_2$ emission from the plant. There are several methods of co-firing and it can be categorized into (1) Parallel co-firing, (2) Indirect co-firing, and (3) Direct co-firing. Parallel co-firing is the most expensive way to high-ratio co-firing because it requires biomass dedicated boiler. Direct co-firing is widely used because it does not need high capital cost compared with the other two methods. Regarding the direct co-firing, it can be classified into three methods- Method 1 does not need retrofit of the facilities because it uses existing coal mills for pulverizing biomass fuels. In this case high-ratio co-firing cannot be achieved because of poor grindability of biomass fuels. Method 2 needs biomass-dedicated mills and revision of fuel streams for the combustion system, and Method 3 needs additional retrofit of the boiler as well as biomass mills. It can achieve highest share of the biomass co-firing compared with other two methods. In Korea, many coal power plants have been adopting Method 1 for coping with RPS(Renewable portfolio standards). Higher co-firing ratio (> 5% thermal share) has not been considered in Korean power plants due to policy of limitation in biomass co-firing for securing REC(Renewable Energy Certificate). On the other hand, higher-share co-firing of biomass is widely used in Europe and US using biomass dedicated mills, following their policy to enhance utilization of renewable energy in those countries. Technical problems which can be caused by increasing share of the biomass in coal power plants are summarized and discussed in this report. $CO_2$ abatement will become more and more critical issues for coal power plants since Paris agreement(2015) and demand of higher share of biomass in the coal power plants will be rapidly increased in Korea as well. Torrefaction of the biomass can be one of the best options because torrefied biomass has higher heating value and grindability than other biomass fuels. Perspective of the biomass torrefaction for co-firing is discussed, and economic feasibility of biomass torrefaction will be crucial for implementation of this technology.

A Study on Enhancement Method of Hosting Capacity for PV System Based on Primary Feeder Reconfiguration (배전선로 절체에 의한 태양광전원의 수용성 향상방안에 관한 연구)

  • Lee, Myung-Geun;Lee, Hu-Dong;Ferreira, Marito;Park, Ji-Hyun;Tae, Dong-Hyun;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.239-249
    • /
    • 2019
  • Recently, the Korean government has implemented a policy to expand renewable energy sources. Large-scale PV systems are being actively interconnected with the distribution system. On the other hand, when a large-scale PV system is installed and operated, the customer voltages could violate the allowable voltage limit due to reverse power flow of the PV system. To overcome these problems, an enhancement method for hosting the capacity of the PV system in a distribution system is being actively conducted. Therefore, to improve the hosting capacity of the PV system, this paper proposes a model of a reconfiguration of the distribution system, which is composed of three sections and three connections based on PSCAD/EMTDC S/W, and proposes an evaluation algorithm for the feeder reconfiguration to maximize an adaption of the PV system. In addition, this paper presents the optimal method of the feeder reconfiguration section to evaluate the maximum capacity of the PV system to keep customer voltages within the allowable voltage limits based on various operation scenarios, such as the capacity of a PV system and section of feeder reconfiguration. From the simulation results based on the PSCAD/EMTDC modeling and evaluation algorithm, it was confirmed that they are a useful and practical tool to enhance hosting the capacity of a PV system in a distribution system.

A Study on Connection of Fuel Processor and NG blower for Small Commercial Fuel Cell System (건물용 연료전지 시스템용 연료처리장치와 연료승압 블로워 연계 특성에 관한 연구)

  • Kim, Jaedong;Jang, Sejin;Kim, Bonggyu;Kim, Jinwook;Han, Sienho;Park, Dalryung
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.5
    • /
    • pp.36-44
    • /
    • 2017
  • The small commercial fuel cell is a new energy system that produces electricity and heat through electrochemical reaction between air and hydrogen. In Korea, hundreds of domestic small commercial fuel cell systems have been installed and operated every years and many parts in fuel cell systems depend on overseas products. KOGAS(Korea Gas Corporation) has developed the fuel processor which is an important part of fuel cell system and has evaluated the long-term durability. And KOGAS has evaluated domestic and overseas NG blower and fuel processor connected to NG blower. The fuel processor developed by KOGAS have maintained an efficiency of 76% and constant performance over 3,000 hours. The NG blower developed in Korea showed similar characteristics as overseas NG blower in the evaluation of power consumption according to rear pressure and outside temperature. The fuel processor module, fuel processor connected to BOP showed excellent performance.

Water Quality Monitoring in Small/Medium Sized Reservoirs (국내 중소형 저수지 활용을 위한 수질 분석)

  • Lim, Myunghee;Lee, Wontae;Son, Younggyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.11
    • /
    • pp.631-635
    • /
    • 2015
  • Water quality investigation was conducted for small/medium sized reservoirs in A city in June and November 2014 as a preliminary step for further use. Water quality analysis experiments were conducted for 21 reservoirs managed by a local government and water quality data were obtained from Korea Rural Community Corporation for 12 reservoirs. It was found that relatively poor water quality, not satisfied with the regulation level (somewhat poor(IV)) for agricultural use, was observed for some reservoirs and worse water quality (poor(V) and very poor(VI) grade) was observed for more reservoirs during autumn /winter season due to the decrease in water volume. Correspondingly, the trophic state was obtained as "Eutrophic" or "Hypertrophic" using the Korean trophic state index for most reservoirs. It was also revealed that significant contamination in sediments was not observed for selected 8 reservoirs considering water quality in each reservoir. The results in this study could be useful for the use of small/medium sized reservoirs as alternative water resources, tourism resources, inland fishery resources, renewable energy production sites, and anti-flooding reservoirs.

Evaluation of Swine Wastewater Pretreatment Using Anaerobic Filter (Anaerobic Filter에 의한 양돈폐수의 전처리 특성 평가)

  • Kang, Ho;Moon, Seo-yeon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.7
    • /
    • pp.418-425
    • /
    • 2015
  • Anaerobic Filters (AF) packed with porous ceramic floating media were operated at different operational conditions to identify the feasibility of the renewable bioenergy, methane production from swine wastewater and to verify the suitability of effluent from anaerobic filters for the subsequent biological nitrogen and phosphorus removal. Stepwise increase in organic loading rates (OLRs) or decrease in hydraulic retention times (HRTs) with influent TCOD concentration of 14,000 mg/L were utilized at mesophilic temperature. The maximum methane productivity of 1.74 volume of $CH_4$ per volume of reactor per day (v/v-d) was achieved at an hydraulic retention time (HRT) of 0.5 day (OLR 28 g TVS/L-d). Based on the biogas production, the highest total volatile solids (TVS) removal efficiency of 63% was obtained at an HRT of 3 days (OLR 4.67 g TVS/L-d), however based on the result from the effluent total chemical oxygen demand (TCOD) analysis, the highest TCOD removal efficiency of 75% was achieved. The effluent alkalinity concentration over the range of 2,050~2,980 mg/L as $CaCO_3$ at all operational conditions, could compensate the alkalinity destruction caused by nitrification. The effluent from the anaerobic filter operated under the HRT of 2 days showed the COD/TKN ratio of 15~35 and COD/TP ratio of 38~56. Therefore effluent C/N/P ratio is able to satisfy the optimum COD/TKN ratio of greater than 8.0 and COD/TP ratio of 33 for the subsequent biological nutrient removal.