• Title/Summary/Keyword: 신호변환

Search Result 2,729, Processing Time 0.033 seconds

A 10b 50MS/s Low-Power Skinny-Type 0.13um CMOS ADC for CIS Applications (CIS 응용을 위해 제한된 폭을 가지는 10비트 50MS/s 저 전력 0.13um CMOS ADC)

  • Song, Jung-Eun;Hwang, Dong-Hyun;Hwang, Won-Seok;Kim, Kwang-Soo;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.5
    • /
    • pp.25-33
    • /
    • 2011
  • This work proposes a skinny-type 10b 50MS/s 0.13um CMOS three-step pipeline ADC for CIS applications. Analog circuits for CIS applications commonly employ a high supply voltage to acquire a sufficiently acceptable dynamic range, while digital circuits use a low supply voltage to minimize power consumption. The proposed ADC converts analog signals in a wide-swing range to low voltage-based digital data using both of the two supply voltages. An op-amp sharing technique employed in residue amplifiers properly controls currents depending on the amplification mode of each pipeline stage, optimizes the performance of op-amps, and improves the power efficiency. In three FLASH ADCs, the number of input stages are reduced in half by the interpolation technique while each comparator consists of only a latch with low kick-back noise based on pull-down switches to separate the input nodes and output nodes. Reference circuits achieve a required settling time only with on-chip low-power drivers and digital correction logic has two kinds of level shifter depending on signal-voltage levels to be processed. The prototype ADC in a 0.13um CMOS to support 0.35um thick-gate-oxide transistors demonstrates the measured DNL and INL within 0.42LSB and 1.19LSB, respectively. The ADC shows a maximum SNDR of 55.4dB and a maximum SFDR of 68.7dB at 50MS/s, respectively. The ADC with an active die area of 0.53$mm^2$ consumes 15.6mW at 50MS/s with an analog voltage of 2.0V and two digital voltages of 2.8V ($=D_H$) and 1.2V ($=D_L$).

A Study on Compensation for Imaging Qualities Having Artifact with the Change of the Center Frequency Adjustment and Transmission Gain Values at 1.5 Tesla MRI (1.5 Tesla 기기에서 중심주파수 조정과 송 신호강도(Transmission Gain)값 변화에 따른 인공물이 있는 자기공명영상의 질 보상에 관한 연구)

  • Lee, Jae-Seung;Goo, Eun-Hoe;Park, Cheol-Soo;Lee, Sun-Yeob;Lee, Han-Joo
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.244-252
    • /
    • 2009
  • The purpose of this study is to compensate for susceptibility and a ferromagnetic body artifact using CFA and TGV on MR Imaging. A total of 30 patients (15 men and 15 women, mean age: 45 years) were performed on head and neck diseases. MR Unit used a 1.5T superconducting magnet (GE medical system, High Density). This study have investigated by changing with CFA and TGV (70, 90, 110, 130, 150) searching for compensation values about susceptibility and a ferromagnetic body artifact in 60 kg standards of body weight (p<0.05). As a quality results, Image qualities were obtained at different score from CFA and TGV (70, 90, 110, 130, $150=3.23{\pm}0.35$, $4.31{\pm}0.02$ $4.23{\pm}0.21$, $5.12{\pm}0.25$, $7.13{\pm}0.72$, $8.31{\pm}0.01$, $5.21{\pm}0.15$, $6.14{\pm}0.08$, $5.23{\pm}0.72$, $5.91{\pm}0.06$, p<0.05). Absolute CNRs (TG, CNRpre, CNRpost) were acquired with (70:$-1.44{\pm}0.11$, $-2.7{\pm}0.04$, 90:$-2.18{\pm}0.42$, $-4.41{\pm}0.43$, 110:$-2.89{\pm}0.43$, $-5.23{\pm}0.02$, 130:$-2.34{\pm}0.05$, $-5.26{\pm}0.01$, 150: $-2.09{\pm}0.08$, $-3.87{\pm}0.12$, p<0.05). In conclusions, this study could be compensated for metal and flow artifacts surrounding the tissues having artifact by changing CFA and TGV.

  • PDF

A 0.31pJ/conv-step 13b 100MS/s 0.13um CMOS ADC for 3G Communication Systems (3G 통신 시스템 응용을 위한 0.31pJ/conv-step의 13비트 100MS/s 0.13um CMOS A/D 변환기)

  • Lee, Dong-Suk;Lee, Myung-Hwan;Kwon, Yi-Gi;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.3
    • /
    • pp.75-85
    • /
    • 2009
  • This work proposes a 13b 100MS/s 0.13um CMOS ADC for 3G communication systems such as two-carrier W-CDMA applications simultaneously requiring high resolution, low power, and small size at high speed. The proposed ADC employs a four-step pipeline architecture to optimize power consumption and chip area at the target resolution and sampling rate. Area-efficient high-speed high-resolution gate-bootstrapping circuits are implemented at the sampling switches of the input SHA to maintain signal linearity over the Nyquist rate even at a 1.0V supply operation. The cascode compensation technique on a low-impedance path implemented in the two-stage amplifiers of the SHA and MDAC simultaneously achieves the required operation speed and phase margin with more reduced power consumption than the Miller compensation technique. Low-glitch dynamic latches in sub-ranging flash ADCs reduce kickback-noise referred to the differential input stage of the comparator by isolating the input stage from output nodes to improve system accuracy. The proposed low-noise current and voltage references based on triple negative T.C. circuits are employed on chip with optional off-chip reference voltages. The prototype ADC in a 0.13um 1P8M CMOS technology demonstrates the measured DNL and INL within 0.70LSB and 1.79LSB, respectively. The ADC shows a maximum SNDR of 64.5dB and a maximum SFDR of 78.0dB at 100MS/s, respectively. The ABC with an active die area of $1.22mm^2$ consumes 42.0mW at 100MS/s and a 1.2V supply, corresponding to a FOM of 0.31pJ/conv-step.

Sputtering방식을 이용한 Indium Thin oxide박막의 넓이에 따른 X-ray 검출기 특성 연구

  • Kim, Dae-Guk;Sin, Jeong-Uk;O, Gyeong-Min;Kim, Seong-Heon;Lee, Yeong-Gyu;Jo, Seong-Ho;Nam, Sang-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.321-322
    • /
    • 2012
  • 의료용 방사선 장비는 초기의 아날로그 방식의 필름 및 카세트에서 진보되어 현재는 디지털 방식의 DR (Digital Radiography)이 널리 사용되며 그에 관한 연구개발이 활발히 진행되고 있다. DR은 크게 간접방식과 직접방식의 두 분류로 나눌 수 있는데, 간접방식은 X선을 흡수하면 가시광선으로 전환하는 형광체(Scintillator)를 사용하여 X선을 가시광선으로 전환하고, 이를 Photodiode와 같은 광소자로 전기적 신호로 변환하여 방사선을 검출하는 방식을 말하며, 직접 방식은 X선을 흡수하면 전기적 신호를 발생 시키는 광도전체(Photoconductor)를 사용하여 광도전체 양단 전극에 고전압을 인가한 형태를 취하고 있는 가운데, X선이 조사되면 일차적으로 광도전체 내부에서 전자-전공쌍(Electron-hole pair)이 생성된다. 이들은 광도전체 양단의 인가되어 있는 전기장에 의해 전자는 +극으로, 전공은 -극으로 이동하여 아래에 위치한 Active matrix array을 통해 방사선을 검출하는 방식이다. 본 연구에서는 직접방식 X-ray 검출기에서 활용되는 a-Se을 ITO (Indium Thin oxide) glass 상단에 Thermal evaporation증착을 이용하여 두께 $50{\mu}m$, 33 넓이로 증착 시킨 다음, a-Se상단에 Sputtering증착을 이용하여 ITO를 11 cm, 22 cm, $2.7{\times}2.7cm$ 넓이로 증착시켜 상하부의 ITO를 Electrode로 이용하여 직접방식의 X-ray검출기 샘플을 제작하였다. 제작 과정 중 a-Se의 Thermal evaporation증착 시, 저진공 $310^{-3}_{Torr}$, 고진공 $2.210^{-5}_{Torr}$에서 보트의 가열 온도를 두 번의 스텝으로 나누어 증착 시켰다. 첫 번째 스텝 $250^{\circ}C$, 두 번째 스텝은 $260^{\circ}C$의 조건으로 증착하여 보트 내의 a-Se을 남기지 않고 전량을 소모할 수 있었으며, 스텝간의 온도차를 $10^{\circ}C$로 제어하여 균일한 박막을 형성 할 수 있었다. Sputtering증착 시, 저진공 $2.510^{-3}$, 고진공 $310^{-5}$에서 Ar, $O_2$를 사용하여 100 Sec간 플라즈마를 생성시켜 ITO를 증착하였다. 제작된 방사선 각각의 검출기 샘플 양단의 ITO에 500V의 전압을 인가하고, 진단 방사선 범위의 70 kVp, 100 mA, 0.03 sec 조건으로 X-ray를 조사시켜 ITO넓이에 따른 민감도(Sensitivity)와 암전류(Dark current)를 측정하였다. 측정결과 민감도(Sensitivity)는 X-ray샘플의 두께에 따른 $1V/{\mu}m$ 기준 시, 증착된 ITO의 넓이가 11 cm부터 22 cm, $2.7{\times}2.7cm$까지 각각 $7.610nC/cm^2$, $8.169nC/cm^2$, $6.769nC/cm^2$로 22 cm 넓이의 샘플이 가장 높은 민감도를 나타내었으나, 암전류(Dark current)는 $1.68nA/cm^2$, $3.132nA/cm^2$, $5.117nA/cm^2$로 11 cm 넓이의 샘플이 가장 낮은 값을 나타내었다. 이러한 데이터를 SNR (Signal to Noise Ratio)로 합산 하였을 시 104.359 ($1{\times}1$), 60.376($2{\times}2$), 30.621 ($2.7{\times}2.7$)로 11 cm 샘플이 신호 대 별 가장 우수한 효율을 나타냄을 알 수 있었다. 따라서 ITO박막의 면적이 클수록 민감도는 우수하나 그에 따른 암전류의 증가로 효율이 떨어짐을 검증 할 수 있었으며, 이는 ITO면적이 넓어짐에 따른 저항의 증가로 암전류에 영향을 끼침을 할 수 있었다. 본 연구를 통해 a-Se의 ITO 박막 면적에 따른 전기적 특성을 검증할 수 있었다.

  • PDF

Gene Expression Profiles in Cervical Cancer with Radiation Therapy Alone and Chemo-radiation Therapy (자궁경부암의 방사선치료 및 방사선항암화학 병용치료에 따른 유전자발현 조절양상)

  • Lee Kyu Chan;Kim Meyoung-kon;Kim Jooyoung;Hwang You Jin;Choi Myung Sun;Kim Chul Yong
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.54-65
    • /
    • 2003
  • Purpose : To analyze the gene expression Profiles of uterine ceulcal cancer, and its variation after radiation therapy, with or without concurrent chemotherapy, using a CDNA microarray. Materials and Methods :Sixteen patients, 8 with squamous ceil carcinomas of the uterine cervix, who were treated with radiation alone, and the other 8 treated w14h concurrent chemo-radiation, were Included in the study. Before the starling of the treatment, tumor biopsies were carried out, and the second time biopsies were peformed after a radiation dose of 16.2$\~$27 Gy. Three normal cervix tissues were used as a control group. The microarray experiments were peformed with 5 groups of the total RNAs extracted individually and then admixed as control, pre-radiation therapy alone, during-radiation therapy alone, pre-chemoradiation therapy, and during-chemoradlation therapy. The 33P-iabeled CDNAS were synthesized from the total RNAs of each group, by reverse transcription, and then they were hybridized to the CDNA microarray membrane. The gene expression of each microarrays was captured by the intensity of each spot produced by the radioactive isotopes. The pixels per spot were counted with an Arrayguage, and were exported to Microsoft Excel The data were normalized by the Z transformation, and the comparisons were peformed on the Z-ratio values calculated. Results : The expressions of 15 genes, including integrin linked kinase (ILK), CDC28 protein kinase 2, Spry 2, and ERK 3, were increased with the Z-ratio values of over 2.0 for the cervix cancer tissues compared to those for the normal controls. Those genes were involved In cell growth and proliferation, cell cycle control, or signal transduction. The expressions of the other 6 genes, Including G protein coupled receptor kinase 5, were decreased with the Z-ratio values of below -2.0. After the radiation thorapy, most of the genes, with a previously Increase expressions, represented the decreased expression profiles, and the genes, with the Z-ratio values of over 2.0, were cyclic nucleotlde gated channel and 3 Expressed sequence tags (EST). In the concurrent chemo-radiation group, the genes involved in cell growth and proliferation, cell cycle control, and signal transduction were shown to have increased expressions compared to the radiation therapy alone group. The expressions of genes involved in anglogenesis (angiopoietln-2), immune reactions (formyl peptide receptor-iike 1), and DNA repair (CAMP phosphodiesterase) were increased, however, the expression of gene involved In apoptosls (death associated protein kinase) was decreased. Conclusion : The different kinds of genes involved in the development and progression of cervical cancer were identified with the CDNA microarray, and the proposed theory is that the proliferation signal stalls with ILK, and is amplified with Spry 2 and MAPK signaling, and the cellular mitoses are Increased with the increased expression oi Cdc 2 and cell division kinases. After the radiation therapy, the expression profiles demonstrated 4he evidence of the decreased cancer cell proliferation. There was no sigificant difference in the morphological findings of cell death between the radiation therapy aione and the chemo-radiation groups In the second time biopsy specimen, however, the gene expression profiles were markedly different, and the mechanism at the molecular level needs further study.

Development of Radiation Image Sensor using Heterojunction (이종접합을 이용한 방사선 영상 센서 개발)

  • Kim, Young-Bin;Yun, Min-Seok;Kim, Min-Woo;Jung, Suk-Hee;Kim, Yoon-Suk;Oh, Kyung-Min;Nam, Sang-Hee;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.3
    • /
    • pp.27-35
    • /
    • 2009
  • In this study, the basic research verifying possibility of applications as radiology image sensor in Digital Radiography was performed, the radiology image sensor was fabricated using double layer technique tio decrease dark current. High efficiency material in substitution for a-Se have been studied as a direct method of imaging detector in Digital Radiography to decrease dark current by using Hetero junction already used as solar cell, semiconductor. Particle-In-Binder method is used to fabricate radiology image sensor because it has a lot of advantages such as fabrication convenient, high yield, suitability for large area sensor. But high leakage current is one of main problem in PIB method. To make up for the weak points, double layer technique is used, and it is considered that high efficient digital radiation sensor can be fabricated with easy and convenient process. In this study, electrical properties such as leakage current, sensitivity is measured to evaluate double layer radiation sensor material.

  • PDF

Node Architecture and Cell Routing Strategies for ATM Applications in WDM Multihop Networks (WDM 다중홉 망에서 ATM 응용을 위한 노드 구조 및 셀 라우팅 기법)

  • Lee, Ho-Suk;Lee, Cheong-Hun;So, Won-Ho;Kwon Hyeok-Jung;Kim, Yeong-Cheon
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.11
    • /
    • pp.44-52
    • /
    • 1998
  • In this paper, we proposed a node architecture and cell routing strategies for ATM applications in WDM multihop networks. The proposed node architecture employs the optical delay loop for storing the cell which is failed in out-link contention. This optical delay loop allows the delay of one cell without the electro-optic conversion. Therefore, we can get the advantages of S&F(Store-and-Forward) routing in Deflection-based all-optical networks. To support the ATM applications efficiently. we considered the transmission priority of ATM cell so that high priority cell can be transmitted with lower loss and shorter delay than low priority one. Two kinds of routing strategies are designed for this architecture: Scheme-Ⅰand Scheme-Ⅱ. Scheme-Ⅰapplies S&F routing to high cell and Deflection routing to low cell, i.e., high cells are routed along the shortest path based on S&F routing, but low cells are deflected or lost. Schem-Ⅱ is similar to Scheme-Ⅰexcept that low cells can occupy the optical loop if it is available. This Scheme-Ⅱ increases the utilization of network resources without decreasing the throughput of high cell by reducing the low cell loss rate when traffic load is low. Simulation results show that our routing strategies have better performance than conventional ones under non-uniform traffic as well as uniform traffic.

  • PDF

Dependencies of Group Velocity and Attenuation Coefficient on Structural Properties in Copper and Nickel Foams with an Open-Celled Structure as Trabecular-Bone-Mimicking Phantoms (해면질골 팬텀으로서 개포된 구조를 갖는 구리폼 및 니켈폼에서 구조적 특성에 대한 군속도 및 감쇠계수의 의존성)

  • Kim, Seong-Il;Lee, Kang-Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.3
    • /
    • pp.158-166
    • /
    • 2011
  • In the present study, copper and nickel foams with an open-celled structure as trabecular-bone-mimicking phantoms were used to investigate the dependencies of group velocity and attenuation coefficient on structural properties such as trabecular thickness (Tb.Th) and trabecular separation (Tb.Sp) in trabecular bone. The group velocity and attenuation coefficient of the copper and nickel foams were measured by a through-transmission method in water, using a pair of broadband, unfocused transducers with a diameter of 12.7 mm and a center frequency of 1.0 MHz. The separation of the Biot's fast and slow waves was consistently observed in the ultrasonic signals transmitted through the copper and nickel foams. The group velocities of the copper and nickel foams showed highly positive correlations with Tb.Th and Tb.Sp. The attenuation coefficient of the copper foam showed a highly negative correlation with Tb.Th and Tb.Sp, whereas that of the nickle foam showed a highly positive correlation with Tb.Th and Tb.Sp. These results advance our understanding of those previously reported by other researchers using trabecular bone samples or phantoms.

Development of the RAS-RMS Protocol optimized to PSTN environment and Implementation of its differentiated process (PSTN 환경에 최적화된 RAS-RMS 연동 프로토콜 개발 및 차별화된 처리과정 구축)

  • Chang, Sung-Keun;Lee, Jung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8357-8362
    • /
    • 2015
  • The emergency call device has been installed and operated for the elevator passenger safety, but the call can not be connected or delay to the operator in an emergency. The application of the Internet of Things(IoT) technology is required for the systematic management and reliability of the emergency call device installed in the elevator. To meet these requirements it is necessary to apply the RMS(Remote Management System). Emergency call device periodically reports the operating status information and the emergency call history information of the emergency call device to the RMS in the PSTN(Public Switched Telephone Network) environment, and transmits the call request information in an emergency. RAS(Remote Access Server) plays a role of converting the PSTN signals to TCP / IP. RMS reports a significant outbreak call and abnormal operating conditions to administrators. In this study, we developed optimized protocol to PSTN environment that is required by RMS and implemented its differentiated process. And a RAS-RMS Protocol was added to the Application Layer. Development protocol consisting of simple structure as compared to CoAP, MQTT or HTTP can work properly in low-spec CPU and transmit elevator emergency key information easily.

A Fast Search Algorithm for Raman Spectrum using Singular Value Decomposition (특이값 분해를 이용한 라만 스펙트럼 고속 탐색 알고리즘)

  • Seo, Yu-Gyung;Baek, Sung-June;Ko, Dae-Young;Park, Jun-Kyu;Park, Aaron
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8455-8461
    • /
    • 2015
  • In this paper, we propose new search algorithms using SVD(Singular Value Decomposition) for fast search of Raman spectrum. In the proposed algorithms, small number of the eigen vectors obtained by SVD are chosen in accordance with their respective significance to achieve computation reduction. By introducing pilot test, we exclude large number of data from search and then, we apply partial distance search(PDS) for further computation reduction. We prepared 14,032 kinds of chemical Raman spectrum as the library for comparisons. Experiments were carried out with 7 methods, that is Full Search, PDS, 1DMPS modified MPS for applying to 1-dimensional space data with PDS(1DMPS+PDS), 1DMPS with PDS by using descending sorted variance of data(1DMPS Sort with Variance+PDS), 250-dimensional components of the SVD with PDS(250SVD+PDS) and proposed algorithms, PSP and PSSP. For exact comparison of computations, we compared the number of multiplications and additions required for each method. According to the experiments, PSSP algorithm shows 64.8% computation reduction when compared with 250SVD+PDS while PSP shows 157% computation reduction.