• Title/Summary/Keyword: 신축주택

Search Result 167, Processing Time 0.021 seconds

Development of BIM Standard Database System for an Approximate Estimate of Old-Aged Apartment Remodeling Project (노후공동주택 리모델링의 개략견적을 위한 BIM 데이터베이스 구축)

  • Lee, Dong-Gun;Cha, Hee-Sung
    • Korean Journal of Construction Engineering and Management
    • /
    • v.11 no.5
    • /
    • pp.53-64
    • /
    • 2010
  • Remodeling becomes the significant issue in the aspect of the resource recycling, because it does not demolishes the whole buildings, but a part of main structure. However, compared with new construction, remodeling has several problems of adding the repair and rehabilitation works, using the partial demolition method, and having difficulties of making decision due to disagreement between several owner organizations. BIM, which is the total solution for managing and producing information during whole life cycle of the buildings, seems to be the right solution for the way to address these issues. has a possibility for solving the problems. Therefore this paper provided the framework and database for applying the BIM in the remodeling, and proved the applicability of the BIM database in the remodeling project through the case studies.

주택환기시스템 구성 및 개발방향

  • 이성한
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.33 no.6
    • /
    • pp.32-36
    • /
    • 2004
  • 주택의 공기질 환경에 대하여 사회적 이슈가 된 새집증후군에 대한 언론매체의 집중적 보도와 실내 공기질이 인체에 미치는 영향에 대한 연구보고서의 잇따른 발표에 따라 실내 공기 질에 대한 관심이 점점 더 고조되고 있는 시점에 환경부의 실내공기질 관리법에 의해 2004년 5월부터 신축되는 공동주택의 경우 포름알테히드와 VOCs등 새집에서 발생되는 유해 물질을 입주 전 측정하여 공고하여야 한다는 법이 제정이 되어있다. 따라서 각 건설사 및 관련 업계에서는 실내의공기질을 개선하기 위한 다양한 방법을 연구하고 있으며 일차적으로 유해오염물질이 발생되지 않는 건축자재를 사용하는 근본적인 오염원인을 제거하는 source control를 선행을 하고 2차적으로 거주자가 주거생활을 하면서 발생시키는 오염물질인 $CO_2$및 분진 냄새 등은 강제환기를 통해서 개선시키는 방법을 채택하여 실내공기 질을 개선하고자 노력하고 있다. (중략)

  • PDF

Analysis and Suggestion of Environment-friendly Interior Finishing Materials for Aged Apartment Remodeling (노후 공동주택 리모델링의 친환경 실내 마감재료 분석 및 제안)

  • Kim, Ki-Hyun;Kim, Kyung-Rai
    • Korean Journal of Construction Engineering and Management
    • /
    • v.8 no.2
    • /
    • pp.118-126
    • /
    • 2007
  • Environmentally Sound and Sustainable Development (ESSD)" is a key word in recent years. The construction industry, have put a great influence on ergonomic and sustainable environment. Recently, "green building certifications", such as Indoor Air Quality (IAQ) and eco-friendly material regulation have been established. With this regard, new construction and aged-housing remodeling projects are required to meet these certification criteria. Apartment residents have great concern on eco-product, since many cases are reported that Sick Building Syndrome is caused by toxic substance from building materials. Aged-housing remodeling construction has a unique characteristic in that the residents are already determined prior to construction execution. Therefore, the analysis of resident's need for building materials in aged-housing remodeling is relatively easy compared to new building construction. As such, it is very important to analyze their preferences for eco-friendly materials prior to project execution. The purpose of this study is to find the needs of residents and priority of their needs. Based on their needs and priority, this paper provides a new strategy in using environment-friendly materials and maximizing their satisfaction level when aged housing remodeling is constructed. In addition, this paper provide new criteria in selecting new developed environmental materials in remodeling projects for the purpose of improving the safety and health level in construction industry.

An Introduction to the Shrinkage Strip for the Crack Control in the Underground Parking Structure (지하주차장의 수축대 시공사례)

  • 김록배;김욱중;이도범;이운세
    • Magazine of the Korea Concrete Institute
    • /
    • v.14 no.2
    • /
    • pp.77-82
    • /
    • 2002
  • 일반적으로 공동주택 지하주차장과 같이 구조물이 대형화되거나 복잡할 경우 구조물의 응력취약 부위에서 균열, 누수 등의 문제가 발생할 확률이 크다. 이에 대한 대책으로 설계자들은 신축줄눈을 선호하고 있으나 신축줄눈은 시공상의 어려움과 사용 중 잦은 하자 발생이라는 문제점을 안고 있다. 이 때문에 근래에 들어 대형 건물을 한 단위로 처리하고 철근으로 보강하려는 경향이 있으나 구속도 차이에 따라 균열, 누수 등의 문제가 여전히 발생하고 있다. 이를 해결하기 위하여 수축대를 설치하여 일정 요구량의 초기 수축량을 수축대에서 흡수하고 이후 수축대 부위에 콘크리트를 메워 일체화시킴으로써 초기 수축에 의한 균열을 상당부분 방지할 수 있다.(중략)

An Effects of Air-Assisted-Catalyst Element for Reducing Density of Formaldehyde in a New House (신축주택에서 포름알데히드 농도저감에 대한 공기 촉매제의 효과에 관한 연구)

  • Jo, Hyeon-U;Park, U-Yeol;Jo, Hun-Hui;Jo, Ho-Gyu;Gang, Gyeong-In
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.3
    • /
    • pp.161-167
    • /
    • 2004
  • The sick house syndrome is occurred from the harmful elements that the building interior materials are given off after building construction or renovation. The appropriate methods, which is to prevent sick house syndrome from spreading have to be selected before building construction or renovation. Thus, this study is to measure the density of formaldehyde, one of the volatile organic compounds after sprinkling air-assisted-catalyst on the building interior space. As a result, the emit value of formaldehyde is measured 0.07ppm that is lower than the standard of Environmental Protection Agency and World Health Organization, 0.1ppm, and the standard of Ministry of Health, Labour, and Welfare of Japan, 0.08ppm.

A Study on Measurement of the Indoor Air Quality in Modular Mock-up Housing (모듈러 목업주택의 실내공기질 실측조사 연구)

  • Chun, Chu-Young;Kim, Jong-Yeob;Bang, Jong-Dae;Kim, Gap-Deug
    • Land and Housing Review
    • /
    • v.6 no.4
    • /
    • pp.231-237
    • /
    • 2015
  • Recently, It has been much interest in modular housing construction. so, The purpose of this study was to investigate the characteristics of the indoor air quality in modular mock-up housing. We measured indoor air quality(formaldehyde, benzene, toluene, ethylbenzene, xylene, styrene) of two modular mock-up units that built-in furniture is installed and uninstalled. As a result, the pollutants of built-in furniture installed unit were emitted more than built-in furniture uninstalled unit. But after bake-out and ventilation, emission concentrations of two modular mock-up units were similar and were below Indoor Air Quality recommendation standards. Built-in furniture is likely to affect the emission concentration of toluene

The Analysis of Risk Factors for Apartment Remodeling Feasibility Study (공동주택 리모델링 사업성 평가를 위한 위험요소 분석)

  • Lee Teck-Wn;Kim Kyoon-Tai;Han Choong-Hee;Kim Sun-Kuk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.3 no.4 s.12
    • /
    • pp.84-92
    • /
    • 2002
  • Recently, apartment-remodeling project is booming since various reconstruction controls are tightened. However, the project has difficulties because management systems used for apartment-remodeling projects are not available. Identifying and analyzing risk factors that are required for risk management, this paper suggests the risk level through paired comparison performed by AHP method and probability assessment for risk level analysis. It is expected that this research will be utilized to minimize the risk of apartment remodeling project and for basic materials to perform the project and helpful to change newly build-oriented construction into sustainable industries. Hereafter using the risk factor analysis data of this paper for this research project, risk management model is considered to be constructed.

Estimation and Determinants on Residential Investment Profits in Seoul: A Focus on Housing Transaction Price from 2010 to 2018 (서울시 주택 예상투자이익 추정과 영향요인에 대한 시론적 분석 - 2010-2018년 주택 실거래가를 중심으로 -)

  • Ahn, Hye-Sung;Kang, Chang-Deok
    • Journal of the Korean Regional Science Association
    • /
    • v.36 no.1
    • /
    • pp.37-50
    • /
    • 2020
  • Estimating investment profits of real estate is critical to understand real estate markets and create relevant policy as real estate market and capital market combines closely. Thus, this study applied the concept of Tobin's Q to estimate investment profits for apartments as well as row-houses and multi-family homes in Seoul from 2010 to 2018. Investment profits were estimated by two approaches: subtracting the replacement cost from the transaction price and calculating ratio of the transaction price to the replacement cost, respectively. The spatio-temporal changes in investment profits were apparent in apartments compared with row-houses and multi-family homes. As a result of analyzing the spatial econometrics models, the investment profit was higher in the area with high density and new developments regardless of the housing types. The framework and key findings would be the effective reference to understand residential investment behavior, create relevant housing policy, introduce value capture of windfall, measure regional competitiveness, and estimate housing bubble.

Exterior Wall Formwork System (외벽 거푸집 시스템(구의 아크로리버 현장 사례를 중심으로))

  • 김동진;김욱종;신동호;이도범
    • Magazine of the Korea Concrete Institute
    • /
    • v.14 no.5
    • /
    • pp.21-26
    • /
    • 2002
  • 구의 아크로리버 현장은 서울의 동쪽에 위치한 지하 5층, 지상 37층과 지상 22/26/29층 2개 동의 업무/판매시설 및 공동주택을 신축하는 주상복합형 프로젝트로서 주변에 강변시외버스터미널과 테크노마트가 바로 인접하여 평소 유동인구가 매우 많은 곳에 위치해 있다. (그림 1)은 구의 아크로리버의 조감도이며, 공사개요는 (표 1)과 같다.(중략)

기획대담-전국보일러설비협회 박기준 회장

  • Korea Boiler Engineering Association
    • 보일러설비
    • /
    • no.11 s.166
    • /
    • pp.74-75
    • /
    • 2007
  • 지속적인 내수경기 및 건설경기 침체, 재개발, 재건축 등으로 인한 주택 개보수시 및 신축시기 연장 등으로 건설시공 수주물량 감소 등으로 인해 시공업계 전체가 힘든 시기를 보내고 있다. 관련업계 한 관계자의"IMF때도 이보다 힘들지 않았다"라는 말은 현재 시공업계를 대변하고 있는 말일 것이다. 일찍이 경험해보지 못했던 고통을 감내하고 있는 시공업계의 현재 상황을 점검하고자 박기준 전국보일러시공협회 회장과 신현석 한국열관리시공협회 회장과의 인터뷰를 진행했다. 이에 본지는 2회에 걸친 인터뷰를 통해 보일러 시공업계의 현실과 앞으로 나아갈 방향성에 대해 논의해 보고자 한다.

  • PDF