• Title/Summary/Keyword: 신뢰성 측정

Search Result 3,159, Processing Time 0.037 seconds

A Study on the Accelerated Life Test for the Estimation of Licorice Durability in Cosmetics (화장품 중 유용성감초추출물의 유통기한 예측을 위한 가속수명 시험연구)

  • Lee, So-Mi;Joo, Kyeong-Mi;Park, Jong-Eun;Jeong, Hye-Jin;Chang, Ih-Seop
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.33 no.3
    • /
    • pp.197-201
    • /
    • 2007
  • Oil soluble licorice extract(licorice extract) is an officially approved cosmetic component as a whitening ingredient in Korea. The durability of licorice, during which the whitening effect can be maintained in optimum condition, must be accurately defined. Since the cosmetics durability under real condition is relatively longer than its development time. It is needed to predict the real durability interval from the experimental measurement under simulated operating conditions. We analyzed the relationship between the licorice lifetime and the high temperature condition by using Arrhenius equation. We have established the constant stress test with temperature of $50^{\circ}C$, $55^{\circ}C$, and $60^{\circ}C$ condition, within which no formulation change of licorice products is expected for the accelerated stress test. In this paper, the lifetime of licorice in cosmetics was defined as time period for its 10% contents reduction. We observed that the lifetime of licorice is 580 h at $50^{\circ}C$, 319 h at $55^{\circ}C$ and 166 h at $60^{\circ}C$. Using the above experimental data, we obtained the equation for the relationship between the licorice lifetime and temperature as follows; log(lifetime)=-35.0243 + 1.15322$\times$(11604.83/temperature). From this equation, the lifetime of licorice at $25^{\circ}C$ can be estimated as 26 months. The estimated result was verified by measuring full lifetime of licorice. In fact, there was no significant difference between the estimated lifetime and real measurement within 95 % significance level. This study can be applied to other useful cosmetic components for the fast estimation of the exact durability.

A STUDY ON THE COLORS OF THE ANTERIOR PRIMARY RESIN TEETH (유치레진치의 전치부 색조연구)

  • Hyun, Hong-Keun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.4
    • /
    • pp.639-645
    • /
    • 2007
  • Removable or fixed space maintainer could be needed if one or some anterior primary teeth were missing, where resin pontics well-matched to natural primary teeth should be demanded to get an esthetic satisfaction. Resin Natural $Teeth^{TM}$(Nissin dental, Japan) is available currently in Korea, which consists of two shades of colors; type A1 and A2. The purpose of this study is to elucidate the colors of the anterior primary resin teeth and to establish the data to compare those with the natural anterior primary teeth. CIE $L^*a^*b^*s$ were measured each three times labially from 17 sets of maxillary four anterior teeth for type A1 and A2 Resin Natural $Teeth^{TM}$ using ShadeEye $NCC^{TM}$(Shofu, Japan) which is one of spectrophotometers. The data were analysed statistically using Kruskall-Wallis Test and Mann-Whitney U Test. The results were as follows : 1. There were smaller teeth color differences in group A1 than in group A2 when it comes to distributions of ${\Delta}E$, $L^*$ and $b^*$. There were no statistically significant differences of $a^*$ between teeth in the same group(P>0.05). 2. ${\Delta}E$ in group A1 and A2 (maximum ${\Delta}E{\le}1.23$) were very small, which could not be discerned by eyesight. ${\Delta}E$ between mean CIE $L^*a^*b^*s$ of group A1 and A2 was 3.97, which could be discernible by eyesight. 3. Mean measurements of group A1 were $L^*=73.8$, $a^*=-1.8$, $b^*=-4.7$, and those of group A2 were $L^*=75.8$, $a^*=-2.7$, $b^*=-1.4$. It would be recommended that resin teeth compatible to the colors of the natural primary ones needed to be developed by investigating in vivo study.

  • PDF

Verification of accuracy detection of the cows estrus using biometric information measuring device (생체정보 측정장치를 활용한 젖소 발정탐지의 정확도 검증)

  • Yang, Ka-Young;Woo, Sae-Mee;Kwon, Kyeong-Seok;Choi, Hee-Chul;Jeon, Jung-Hwan;Lee, Jun-Yeob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.652-657
    • /
    • 2018
  • Breeding control in a farm is a very important factor affecting milk productivity. Breeding management is important for the early detection of estrus, and reliable, automatic, more accurate, and faster monitoring of the timing of dairy cows is essential for farmers. This study measured the accuracy of estrus using the estrus indications, changes in activities, rumination activities, ruminal temperature, and pH. The biomedical information device S1 used in this study provided an estrus notice using the rumen temperature, pH, cow activities, and number of drinking estimations, which were inserted in the rumen through the oral route. The S2 device was used in the estrus notice for the rumen activities and cow activities. The data collected on the instrument were collected at intervals of 2 hours per day at the reference days (RD: -7~-3, +7~+ 3) +2), 7 days before insemination, and 7 days after insemination. The activities of the S1 device used in this paper increased with increasing number of insemination days (-1: $12.5{\pm}1.03/day$; 0: $12.9{\pm}1.73/day$) compared to the reference day (RD: $10.2{\pm}1.0/day$). The activities of the S2 device was also found to increase from the reference day to the insemination day (0: $63.0{\pm}3.66$) compared to the reference day (RD: $40.3{\pm}2.68$). The number of daily drinks in S1 decreased from the reference day (RD: $5.9{\pm}0.89/day$) to before the insemination day (-2: $5.6{\pm}0.98$; -1: $5.7{\pm}0.96$); +2: $6.0{\pm}0.73$). The number of daily drinks on the insemination day (0: $6.3{\pm}0.86$; +2: $6.0{\pm}0.73$) was similar to the reference day. The number of daily rumination in S2 decreased from the reference day (RD: $493.8{\pm}10.92$) to the insemination day (-1: $390.2{\pm}13.36$; 0: $354.1{\pm}16.71$).

Airway Responses to Bronchoprovocation Using High-Resolution Computed Tomography in Patients with Bronchial Asthma (기관지천식환자에 있어서 고해상도 전산화단층촬영술을 이용한 기관지유발에 대한 기도의 반응)

  • Choi, Byoung-Whui;Kang, Yoon-Jeong;Ko, Hyung-Ki;Park, In-Won;Hue, Sung-Ho;Kim, Yang-Soo;Kim, Young-Goo;Kim, Kun-Sang;Kim, Jong-Hyo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.6
    • /
    • pp.813-822
    • /
    • 1995
  • Background: Bronchial hyperresponsiveness and abnormal response such as a loss of distensibility are pathophysiologic characteristics if bronchial asthma. The only means of direct in vivo measurement of airway size had been a tantalium bronchography, until high-resolution computed tomography(HRCT) enabled to measure noninvasively two dimensional airway area more accurately and reliably. Method: To investigate airway area responses to bronchial provocation with methacholine and evaluate the major sites of bronchial constriction in patients with bronchial asthma. We examined HRCT scans in five patients with bronchial asthma who had significant bronchoconstriction(20% or more decrease in $FEV_1$) using CT scanner(5,000T CT, Shimadzu Co, Japan) before and in 3~5 min. after methacholine inhalation. Airways which were matched by parenchymal anatomic landmarks in each patient before and after methacholine inhalation were measured using film scanner(TZ-3X scanner; Truvel Co. Chatsworth CA, USA) and a semiautomated region growing method. Results: 1) We identified 9 to 12 airways in each patient which were matched by parenchymal anatomic landmarks before and after methacholine inhalation. 2) Airway responses to methacholine are quite different even in a patient. 3) The constriction of small airways(average diameter <2 mm; area < $3.14mm^2$) was 48.7%(8.3; SEM, n=43), being more prominant than that of large airways(average diameter >2 mm; area > $3.14mm^2$), 53.8% (4.4;SEM, n=10), but not significantly different(p>0.05). 4) There was no significant difference in the degree of constriction between upper(44.3% +5.8; mean + SEM, n=30) and lower lung regions(56.7% +4.5, n=23). Conclusions: Thus airway responses to methacholine bronchoprovocation is quite variable in a patient with bronchial asthma and has no typical pattern in patients with bronchial asthma.

  • PDF

Glomerular Filtration Rate Test Methods and Guidelines (Glomerular Filtration Rate 검사방법 및 가이드라인)

  • Park, Min-Ho;Lee, Ha-Young;Ryu, Hwa-Jin;Yoo, Tae-Min;Noh, Gyeong-Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.97-100
    • /
    • 2018
  • Purpose The glomerular filtration rate (GFR) test is an important indicator of glomerular filtration and has been used to test renal function and the extent of its function. The GFR test is performed by intravenous injection of radioactive medicines made of $^{51}Cr$-EDTA, and blood concentration is measured by taking blood according to the elapsed time. also, PET-CT, bone scan, transfusion and so on will affect the outcome. Therefore, we will improve the quality of the test by providing guidelines for the GFR test for more accurate testing. Materials and Methods 5 mL of physiological saline solution and 2 mL of $^{51}Cr$-EDTA solution are used to make 5 mL of the radiopharmaceutical solution to be injected into the patient. First, the syringe weight is measured before the injection, and then the radioactive medicine is injected into the patient's vein and the syringe weight is measured after the injection. Blood sampling is performed twice in total. In adults, blood is collected 3 hours / 5 hours after injection and in children 2 hours / 5 hours after injection. The blood sample is centrifuged at 3300 rpm for 5 minutes. Standard solution is prepared by filling diluent water up to the scale indicated in the 200-mL volumetric flask, discarding $500{\mu}L$, injecting $500{\mu}L$ of GFR reagent and mixing well. $500{\mu}L$ each of the standard solution is dispensed into two test tubes, and $500{\mu}L$ of each of the plasma samples collected in time is dispensed into two test tubes and measured with a Cobra Counter. Results At present, the reference range applied in this study is $119.5{\pm}30.3ml/min/1.73m2$ for males and $125.2{\pm}28.2ml/min/1.73m^2$ for females. Conclusion The GFR test is conducted using radioactive medical products. GFR testing is performed as a scheduled test, but PET-CT, dialysis and transfusion, which may affect GFR testing, may be scheduled during GFR testing. Therefore, we could get accurate GFR test results by notifying the ward and department beforehand when booking.

Development of a Tool to Measure Knowledge of Clinical Dental Hygienists on Precautions for Dental Treatment of Dementia Patients (임상 치과위생사의 치매 환자 치과 진료 시 주의 사항에 관한 지식측정 도구 개발)

  • Nahyun Kim;So-Jung Mun;Hie-Jin Noh;Sun-Young Han
    • Journal of Korean Dental Hygiene Science
    • /
    • v.6 no.2
    • /
    • pp.79-89
    • /
    • 2023
  • Background and Objectives: The prevalence of dementia is steadily increasing each year, and preceding studies continue to explore the association between dementia and oral health. Dental hygienists require specialized competencies to provide appropriate dental healthcare services, necessitating the development of a tool for the objective measurement of their knowledge levels. This study aimed to develop a knowledge assessment tool for dental hygienists concerning considerations for dental care for patients with dementia. Methods: The study constructed preliminary items based on a literature review and then conducted expert validation, a pilot survey, and the main survey. The main survey was conducted among 220 dental hygienists. Validity and reliability analyses were conducted with the collected data to select the final items, and the correctness rates for each selected item were verified. Results: As a result of the analysis of the collected data, 18 items were eliminated out of a total of 40 preliminary items, leaving a total of 6 factors and 22 items. The Cronbach's α value for the selected items was 0.791. The six factors are as follows: 'Considerations during dental treatment for dementia patients' (5 items), 'medication side effects in dementia patients' (4 items), 'oral care methods for dementia patients' (4 items), 'communication with dementia patients' (4 items), 'psychological reactions of dementia patients' (3 items), and 'guidance for dementia patients' (2 items). The item with the highest correctness rate was item 2 of the 'guidance for dementia patients' category at 98.6%, while the item with the lowest correctness rate was item 2 of the 'psychological reactions of dementia patients' category at 5.9%. Conclusion: This study validated the reliability and validity of the knowledge assessment tool, which lays the foundation for future research on dental hygienists and dementia. It contributes essential data for ongoing education, development of educational programs, and establishing operational guidelines in healthcare institutions.

The Implementation of a HACCP System through u-HACCP Application and the Verification of Microbial Quality Improvement in a Small Size Restaurant (소규모 외식업체용 IP-USN을 활용한 HACCP 시스템 적용 및 유효성 검증)

  • Lim, Tae-Hyeon;Choi, Jung-Hwa;Kang, Young-Jae;Kwak, Tong-Kyung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.3
    • /
    • pp.464-477
    • /
    • 2013
  • There is a great need to develop a training program proven to change behavior and improve knowledge. The purpose of this study was to evaluate employee hygiene knowledge, hygiene practice, and cleanliness, before and after HACCP system implementation at one small-size restaurant. The efficiency of the system was analyzed using time-temperature control after implementation of u-HACCP$^{(R)}$. The employee hygiene knowledge and practices showed a significant improvement (p<0.05) after HACCP system implementation. In non-heating processes, such as seasoned lettuce, controlling the sanitation of the cooking facility and the chlorination of raw ingredients were identified as the significant CCP. Sanitizing was an important CCP because total bacteria were reduced 2~4 log CFU/g after implementation of HACCP. In bean sprouts, microbial levels decreased from 4.20 logCFU/g to 3.26 logCFU/g. There were significant correlations between hygiene knowledge, practice, and microbiological contamination. First, personnel hygiene had a significant correlation with 'total food hygiene knowledge' scores (p<0.05). Second, total food hygiene practice scores had a significant correlation (p<0.05) with improved microbiological qualities of lettuce salad. Third, concerning the assessment of microbiological quality after 1 month, there were significant (p<0.05) improvements in times of heating, and the washing and division process. On the other hand, after 2 months, microbiological was maintained, although only two categories (division process and kitchen floor) were improved. This study also investigated time-temperature control by using ubiquitous sensor networks (USN) consisting of an ubi reader (CCP thermometer), an ubi manager (tablet PC), and application software (HACCP monitoring system). The result of the temperature control before and after USN showed better thermal management (accuracy, efficiency, consistency of time control). Based on the results, strict time-temperature control could be an effective method to prevent foodborne illness.

Study the Analysis of Comparison with AROI and MROI Mode in Gated Cardiac Blood Pool Scan (게이트심장혈액풀 스캔에서 자동 관심영역 설정과 수동 관심영역 설정 모드의 비교 분석에 관한 고찰)

  • Kim, Jung-Yul;Kang, Chun-Koo;Kim, Yung-Jae;Park, Hoon-Hee;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.222-228
    • /
    • 2008
  • Purpose: The objectives of this study were to compare the left ventricle ejection fraction (LVEF) from gated cardiac blood pool scan (GCBP) for analysis auto-drawing region of interest mode (AROI) and manual-drawing region of interest mode (MROI), respectively. To evaluation the relationships between values produced by both ROI modes. Materials and Methods: Gated cardiac blood pool scan using in vivo method Tc-99m Red Blood Cell were performed for 33 patients (mean age: $53.2{\pm}13.2\;y$) with objective of chemotherapy using single head gamma camera (ADAC Laboratories, Milpitas, CA). Left ventricular ejection fraction was automatically and manually measured, respectively. Results: There was significant difference statistically between AROI and MROI ($LVEF^{AROI}$: $71.4{\pm}12.4%$ vs. $LVEF^{MROI}$: $65.8{\pm}5.9%$, p=0.003). Intra-observer agreements in AROI was higher than MROI ($\gamma^{AROI}=0.964$, Cronbach's $\alpha^{AROI}=0.986$ vs. $\gamma^{MROI}=0.793$, Cronbach's $\alpha^{MROI}=0.911$), either. Additionally, there was no significant difference statistically at best septal view (${\Delta}LVEF^{BSV}=0.7{\pm}2.3%$, p=0.233), however statistically significant difference was found at badly separated septal view (${\Delta}LVEF=10.9{\pm}11.4%$, p=0.001). Moreover, Intra-observer agreements in best septal view was higher than badly separated septal view ($\gamma^{BSV}=0.939$, Cronbach's $\alpha^{BSV}=0.978$; $\gamma=0.948$, Cronbach's $\alpha=0.981$ at AROI, $\gamma^{BSV}=0.836$, Cronbach's $\alpha^{BSV}=0.936$; $\gamma=0.748$, Cronbach's $\alpha=0.888$ at MROI). Conclusion: When best septal view was acquired, LVEF by AROI and MROI indicated not different. Comparing Intra-observer agreements with AROI and MROI, the AROI tended to show higher. Therefore, it is considered that the AROI than MROI is valuable in reproducibility and objective when ROI analysis by acquire left ventricular of best septal view.

  • PDF

Establishment of Test Conditions and Interlaboratory Comparison Study of Neuro-2a Assay for Saxitoxin Detection (Saxitoxin 검출을 위한 Neuro-2a 시험법 조건 확립 및 실험실 간 변동성 비교 연구)

  • Youngjin Kim;Jooree Seo;Jun Kim;Jeong-In Park;Jong Hee Kim;Hyun Park;Young-Seok Han;Youn-Jung Kim
    • Journal of Marine Life Science
    • /
    • v.9 no.1
    • /
    • pp.9-21
    • /
    • 2024
  • Paralytic shellfish poisoning (PSP) including Saxitoxin (STX) is caused by harmful algae, and poisoning occurs when the contaminated seafood is consumed. The mouse bioassay (MBA), a standard test method for detecting PSP, is being sanctioned in many countries due to its low detection limit and the animal concerns. An alternative to the MBA is the Neuro-2a cell-based assay. This study aimed to establish various test conditions for Neuro-2a assay, including cell density, culture conditions, and STX treatment conditions, to suit the domestic laboratory environment. As a result, the initial cell density was set to 40,000 cells/well and the incubation time to 24 hours. Additionally, the concentration of Ouabain and Veratridine (O/V) was set to 500/50 μM, at which most cells died. In this study, we identified eight concentrations of STX, ranging from 368 to 47,056 fg/μl, which produced an S-shaped dose-response curve when treated with O/V. Through inter-laboratory variability comparison of the Neuro-2a assay, we established five Quality Control Criteria to verify the appropriateness of the experiments and six Data Criteria (Top and Bottom OD, EC50, EC20, Hill slop, and R2 of graph) to determine the reliability of the experimental data. The Neuro-2a assay conducted under the established conditions showed an EC50 value of approximately 1,800~3,500 fg/μl. The intra- & inter-lab variability comparison results showed that the coefficients of variation (CVs) for the Quality Control and Data values ranged from 1.98% to 29.15%, confirming the reproducibility of the experiments. This study presented Quality Control Criteria and Data Criteria to assess the appropriateness of the experiments and confirmed the excellent repeatability and reproducibility of the Neuro-2a assay. To apply the Neuro-2a assay as an alternative method for detecting PSP in domestic seafood, it is essential to establish a toxin extraction method from seafood and toxin quantification methods, and perform correlation analysis with MBA and instrumental analysis methods.

The Mid-Term Outcome Evaluation of Community Organization: Three-year Experience of Health Plus Happiness Plus Projects in Gyeongsangnam-Do (지역사회조직화 전략의 중간 결과평가: 경남 건강플러스 행복플러스 사업 3년 경험)

  • Kim, Jang-Rak;Jeong, Baekgeun;Park, Ki-Soo;Kang, Yune-Sik
    • Journal of agricultural medicine and community health
    • /
    • v.39 no.3
    • /
    • pp.146-160
    • /
    • 2014
  • Objective: This study was performed to explore the effectiveness of community organization as a strategy for health promotion. Methods: We used data from community health interviews from 6 administrative sections (eup, myeon, or dong) with high mortality from August to October, conducted once in both 2010 and 2013 as part of the Health Plus Happiness Plus Projects based on the concept of community empowerment in Gyeongsangnam-do Province. For 2010, the study subjects comprised a systematic sampling of 220 adults from each of the six sections for a total of 1320 subjects, and for 2013, 200 from each section for a total of 1200 subjects. We compared main health behavior indicators and empowerment score between these two years. Results: Smoking prevalence in men was 47.4% in 2013, and 47.7% in 2010, respectively. Prevalence of walking 5 days or more per week was 35.6% in 2013, significantly lower than 46.2% in 2010. Also, during that period, both biennial health examination rate and biennial gastric cancer screening rate among those 40 years of age and over significantly increased from 57.7% to 63.6% and from 49.3% to 55.0%, respectively. Mean empowerment score at the community level significantly increased from 12.6 to 14.0. Conclusions: This study suggests that the three-year implementation of community organization might have helped to increase the participation rate of biennial health examinations including cancer screenings in the community. However, this was not the case for smoking cessation and walking. Further studies are needed for evidence-based health promotion.