• Title/Summary/Keyword: 신뢰성 측정

Search Result 3,159, Processing Time 0.046 seconds

High-Speed Shear Test Characterization of Sn-Ag-Cu-In Quaternary Solder Joint (Sn-Ag-Cu-In 4원계 무연솔더 조인트의 고속 전단 특성)

  • Kim, Ju-Hyung;Hyun, Chang-Yong
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.2
    • /
    • pp.91-97
    • /
    • 2014
  • With Pb-free solder joints containing Sn-Ag-Cu-based ternary alloys (Sn-1.0 wt.%Ag-0.5Cu and Sn-4.0Ag-0.5Cu) and Sn-Ag-Cu-In-based quaternary alloys (Sn-1.0Ag-0.5Cu-1.0In, Sn-1.2Ag-0.5Cu-0.4In, Sn-1.2Ag-0.5Cu-0.6In, and Sn-1.2Ag-0.7Cu-0.4In), fracture-mode change, shear strengths, and fracture energies were observed and measured under a high-speed shear test of 500 mm/s. The samples in each composition were prepared with as-reflowed ones or solid-aged ones at $125^{\circ}C$ to 500 h. As a result, it was observed that ductile or quasi-ductile fracture modes occurs in the most of Sn-Ag-Cu-In samples. The happening frequency of a quasi-ductile fracture mode showed that the Sn-Ag-Cu-In joints possessed ductile fracture properties more than that of Sn-3.0Ag-0.5Cu in the high-speed shear condition. Moreover, the Sn-Ag-Cu-In joints presented averagely fracture energies similar to those of Sn-Ag-Cu joints. While maximum values in the fracture energies were measured after the solid aging for 100 h, clear decreases in the fracture energies were observed after the solid aging for 500 h. This result indicated that reliability degradation of the Sn-Ag-Cu-In solder joints might accelerate from about that time.

발전소의 사고 또는 비정상 조건으로 원자로용기내의 증기 또는 수소기체가 발생시 이를 제거하기 위한 설계 분석

  • 민경성;이세용
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.141-147
    • /
    • 1996
  • 1979년 3월 Three Mile Island 2 (TMI-2) 발전소에서 사고가 발생했을 때 원자로용기내에 생성된 수소기체로 인하여 운전원은 원자로용기의 수위를 정확히 측정할 수 없었으며, 이로 인하여 사고상태를 신속히 파악하지 못하였다. TMI 사고이후 미국 원자력규제위원회 NRC는 이 같은 문제점을 해결하고자 미국내 모든 원전에서 사고 또는 비정상 조건이 발생할 경우에 원자로 용기 수위에 대하여 운전원이 신뢰성을 갖을 수 있는 후속조치를 수행토록 요구하였다. 또한 미국의 대표적인 전력연구소인 EFRI에서는 개량형 경수로 (Advanced Light Water Reactor : ALWR) 설계 요건으로 이러한 설계가 반영되도록 요건화 하였다.[1]. 본 논문에서는 2,825 MWt급 한국형 표준원전을 대상으로 EPRI에서 요구한 설계요건에 따라 TMI 2 발전소에서와 같은 사고로 인하여 수소기체가 발생했을 경우와 발전소가 비정상 상태로 인하여 증기가 발생했을 경우에, 이를 신속히 제거하여 운전원이 원자로용기의 수위를 정확히 감지할 수 있도록 하는 설계 방안을 검토하였다. 따라서, 설계방안으로 원자로용기에 모인 증기 또는 수소기체를 계통중 가장 높은 위치에 있으며, 계통구성 기기중 유일하게 2상을 유지하고 있는 가압기로 배출시키고자 두 기기간에 연결관을 설치하는 방안에 대해서 분석하였다. 원자로용기 상부해드와 가압기를 연결하는 방안은 여러가지가 있으나, 검토한 결과 한국형 표준원전에서는 연결관을 가압기 상부해드보다 4m 높게하여 원자로용기 상부해드와 연결하는 방안이 EPRI의 설계요건을 만족하면서 기존설계에 영향을 가장 적게 미치는 적합한 설계방안으로 분석되었다.크다는 단점이 있다.TEX>$_2$O$_3$ 흡착제 제조시 TiO$_2$ 함량에 따른 Co$^{2+}$ 흡착량과 25$0^{\circ}C$의 고온에서 ZrO$_2$$Al_2$O$_3$의 표면에 생성된 코발트 화합물을 XPS와 EPMA로 부터 확인하였다.인을 명시적으로 설명할 수 있다. 둘째, 오류의 시발점을 정확히 포착하여 동기가 분명한 수정대책을 강구할 수 있다. 셋째, 음운 과 정의 분석 모델은 새로운 언어 학습시에 관련된 언어 상호간의 구조적 마찰을 설명해 줄 수 있다. 넷째, 불규칙적이며 종잡기 힘들고 단편적인 것으로만 보이던 중간언어도 일정한 체계 속에서 변화한다는 사실을 알 수 있다. 다섯째, 종전의 오류 분석에서는 지나치게 모국어의 영향만 강조하고 다른 요인들에 대해서는 다분히 추상적인 언급으로 끝났지만 이 분석을 통 해서 배경어, 목표어, 특히 중간규칙의 역할이 괄목할 만한 것임을 가시적으로 관찰할 수 있 다. 이와 같은 오류분석 방법은 학습자의 모국어 및 관련 외국어의 음운규칙만 알면 어느 학습대상 외국어에라도 적용할 수 있는 보편성을 지니는 것으로 사료된다.없다. 그렇다면 겹의문사를 [-wh]의리를 지 닌 의문사의 병렬로 분석할 수 없다. 예를 들어 누구누구를 [주구-이-ν가] [누구누구-이- ν가]로부터 생성되었다고 볼 수 없다. 그러므로 [-wh] 겹의문사는 복수 의미를 지닐 수 없 다. 그러면 단수 의미는 어떻게 생성되는가\ulcorner 본 논문에서는 표면적 형태에도 불구하고

  • PDF

Generalized kernel estimating equation for panel estimation of small area unemployment rates (소지역 실업률의 패널추정을 위한 일반화커널추정방정식)

  • Shim, Jooyong;Kim, Youngwon;Hwang, Changha
    • Journal of the Korean Data and Information Science Society
    • /
    • v.24 no.6
    • /
    • pp.1199-1210
    • /
    • 2013
  • The high unemployment rate is one of the major problems in most countries nowadays. Hence, the demand for small area labor statistics has rapidly increased over the past few years. However, since sample surveys for producing official statistics are mainly designed for large areas, it is difficult to produce reliable statistics at the small area level due to small sample sizes. Most of existing studies about the small area estimation are related with the estimation of parameters based on cross-sectional data. By the way, since many official statistics are repeatedly collected at a regular interval of time, for instance, monthly, quarterly, or yearly, we need an alternative model which can handle this type of panel data. In this paper, we derive the generalized kernel estimating equation which can model time-dependency among response variables and handle repeated measurement or panel data. We compare the proposed estimating equation with the generalized linear model and the generalized estimating equation through simulation, and apply it to estimating the unemployment rates of 25 areas in Gyeongsangnam-do and Ulsan for 2005.

A CMOS 16:1 Binary-Tree Multiplexer applying Delay Compensation Techniques (딜레이 보상 기법을 적용한 바이너리-트리 구조의 CMOS 16:1 멀티플렉서)

  • Shon, Kwan-Su;Kim, Gil-Su;Kim, Kyu-Young;Kim, Soo-Won
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.2
    • /
    • pp.21-27
    • /
    • 2008
  • This paper describes a CMOS 16:1 binary-tree multiplexer(MUX) using $0.18-{\mu}m$ technology. To provide immunity for wide frequency range and process-and-temperature variations, the MUX adopts several delay compensation techniques. Simulation results show that the proposed MUX maintains the setup margins and hold margins close to the optimal value, i.e., 0.5UI, in wide frequency-range and in wide process-and-temperature variations, with standard deviation of 0.05UI approximately. These results represent that these proposed delay compensations are effective and the reliability is much improved although CMOS logic circuits are sensitive to those variations. The MUX is fabricated using $0.18-{\mu}m$ CMOS process, and tested with a test board. At power supply voltage of 1.8-V, maximum data-rate and area of the MUX is 1.65-Gb/s and 0.858 $mm^2$, respectively. The MUX dissipates a power of 24.12 mW, and output eye opening is 272.53 mV, 266.55 ps at 1.65-Gb/s operation.

Low-Cost Remote Power-Quality-Failure Monitoring System using Android APP and MCU (안드로이드 앱과 MCU를 이용한 저가형 원격 전원품질이상 감시 시스템)

  • Lim, Ho-Kyoun;Kim, Seo-Hwi;Lee, Seung-Hyeon;Choe, Sangho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.9
    • /
    • pp.144-155
    • /
    • 2013
  • This paper presents a low-cost remote power-quality-failure monitoring system (RPMS) using Android App and TI MCU (micro-controller unit), which is appliable to a micro-grid. The designed RPMS testbed consists of smart nodes, a server, and Android APPs. Especially, the C2000-series MCU-based RPMS smart node that is low-cost compared to existing monitoring systems has both a signal processing function for power signal processing and a data transmission function for power-quality monitoring data transmission. The signal processing function implements both a wavelet-based power failure detection algorithm including sag, swell, and interruption, and a FFT-based power failure detection algorithm including harmonics such that reliable and real-time power quality monitoring is guaranteed. The data transmission function implements a low-complexity RPMS transmission protocol and defines a simple data format (msg_Diag) for power monitoring message transmission. We may watch the monitoring data in real time both at a server and Android phone Apps connected to the WiFi network (or WAN). We use RS-232 (or Bluetooth) as the wired (or wireless) communication media between a server and nodes. We program the RPMS power-quality-failure monitoring algorithm using C language in the CCS (Code Composer Studio) 3.3 environment.

Evaluation of Field Nonlinear Modulus of Subgrnde Soils Using Repetitive Static Plate Bearing Load Test (반복식 평판재하시험을 이용한 노상토의 현장 변형계수 평가)

  • Kim Dong-Soo;Seo Won-Seok;Kweon Gi-Chul
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.6
    • /
    • pp.67-79
    • /
    • 2005
  • The field plate load test has a good potential for determining modulus since it measures both plate pressure and settlement. Conventionally the modulus has been assumed to be a constant secant value defined from the settlement of the plate at a given load intensity. A constant modulus (modulus of subgrade reaction, k), however, may not be a representative value of subgrade soil under working load. Field strain(o. stress)-dependent modulus characteristics of subgrade soils, at relatively low to intermediate strains, are important in the pavement design. In this study, the field strain dependent moduli of subgrade soils were obtained using cyclic plate load test. Testing procedure and data reduction method are proposed. The field crosshole and laboratory resonant column tests were also performed to determine field nonlinear modulus at $0.001\%\;to\;0.1\%$ strains, and the modulus values and nonlinear trends are compared to those obtained by cyclic plate load tests. Both modulus values match relatively well when the different state of stress between two tests was considered, and the applicability of field cyclic plate load test for determining nonlinear modulus values of subgrade soils is verified.

Performance Comparison of TCP and SCTP in Wired and Wireless Internet Environment (유무선 인터넷 환경에서 TCP와 SCTP의 성능 비교)

  • Sasikala, Sasikala;Seo, Tae-Jung;Lee, Yong-Jin
    • 대한공업교육학회지
    • /
    • v.33 no.2
    • /
    • pp.287-299
    • /
    • 2008
  • HTTP is one of the most widely used protocols of the WWW. Currently it uses TCP as the transport layer protocol to provide reliability. The HTTP uses separate TCP connection for each file request and adds unnecessary head-of-line blocking overhead for the file retrieval. The web application is short sized and affected by the increased handover latency of TCP in wireless environment. SCTP has attractive features such as multi-streaming and multi-homing. SCTP's multi-streaming and multi-homing avoid head-of-line blocking problem of TCP and reduce handover latency of TCP in wired and wireless environment. Mean response time is the important measure in most web application. In this paper, we present the comparison of mean response time between HTTP over SCTP with that of HTTP over TCP in wired and wireless environments using NS-2 simulator. We measured mean response time for varying packet loss rate, bandwidth, RTT, and the number of web objects in wired environment and mean response time and packet loss rate for varying moving speed and region size in wireless environment. Our experimental result shows that SCTP reduces the mean response time of TCP based web traffic.

A study on an instantaneous angular velocity and torque fluctuation for marine diesel engine (선박용 디젤 기관의 순간 각속도와 토크 변동에 관한 연구)

  • Jung, Gyun-sik;Lee, Ji-woong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.7
    • /
    • pp.722-728
    • /
    • 2015
  • The demand for shipboard energy management is expected to gradually increase based on ship energy efficiency management plans (SEEMPs), which have been in use since January 1, 2013. Therefore, the fuel consumption of the main engine, which occupies the greatest portion of the energy used, along with elements related to the engine power, should be strictly monitored. There are many different methods for indicating the engine power. However, this study performed an experiment to monitor the status of a ship's engine power in real time using an encoder and a proximate switch, which are economical to purchase and easy to install. In the experiment, the angular velocity during one cycle of a two-stroke low-speed engine was measured, and the measured data were converted to the torque fluctuation. The angular velocity during an abnormal firing condition in the cylinder was also measured, and the torque fluctuation as a result of a misfire was considered. The results were compared with sea trial data to determine the reliability. In this study, the status of the engine power was determined using the torque fluctuation of the main engine in an operating ship.

Evaluation of Reliability for Combined Refractive Power of Lenses in an Automatic Phoropter (자동포롭터 내부렌즈의 합성굴절력에 대한 신뢰도 평가)

  • Lee, Hyung Kyun;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.501-509
    • /
    • 2015
  • Purpose: To evaluate the reliability of refractive power by comparing the marked refractive power in an automatic phoropter and actually measured spherical/cylindrical refractive power. Methods: Actual refractive power of minus spherical lens and cylindrical lens in an automatic phoropter was measured by a manual lensmeter and compared with the accuracy of marked refractive power. Furthermore, combined refractive power and spherical equivalent refractive power of two overlapped lenses were compared and evaluated with the refractive power of trial lens. Results: An error of 0.125 D and more against the marked degree was observed in 70.6% of spherical refractive power of spherical lens which is built in phoropter, and the higher error was shown with increasing refractive power. Single cylindrical refractive power of cylindrical lens is almost equivalent to the marked degree. Combined spherical refractive power was equivalent to spherical refractive power of single lens when spherical lens and cylindrical lens were overlapped in a phoropter. Thus, there was no change in spherical refractive power by lens overlapping. However, there was a great difference, which suggest the effect induced by overlapping between cylindrical refractive power and the marked degree when spherical lens and cylindrical lens were overlapped. Spherical equivalent refractive power measured by using a phoropter was lower than that estimated by trial glasses frame and marked degree. The difference was bigger with higher refractive power. Conclusions: When assessment of visual acuity is made by using an automatic phoropter for high myopes or myopic astigmatism, some difference against the marked degree may be produced and they may be overcorrected which suggests that improvement is required.

Smart meter data transmission device and power IT system using LTE and IoT technologies (LTE와 IoT 기술을 이용한 스마트미터 데이터 전송장치와 전력 IT 시스템)

  • Kang, Ki-Beom;Kim, Hong-Su;Jwa, Jeong-Woo;Kim, Ho-Chan;Kang, Min-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.117-124
    • /
    • 2017
  • A Smart Grid is a system that can efficiently use energy by exchanging real-time information in both directions between a consumer and a power supplier using ICT technology on an existing power network. DR(Demand response) is an arrangement in which electricity users can sell the electricity they save to the electricity market when the price of electricity is high or the power system is crisis. In this study, we developed a power meter data transmission device and power IT system that measure the demand information in real-time using a smart meter and transmit it to a cloud server. The power meter data transmission device developed in this study uses alight sensor connected to a Raspberry Pi 3 to measure the number of blinking lamps on the KEPCO meter per unit of power, in order to provide reliable data without any measurement errors with respect to the KEPCO power data. The power measurement data transmission device uses the standard communication protocol, OpenADR 2.0b. The measured data is transmitted to the power IT system, which consists of the VEN, VTN, and calculation program, via the LTE WiFi communication network and stored in its MySQL DB. The developed power measurement data transmission device issues a power supply instruction and performs a peak reduction DR when a power system crisis occurs. The developed power meter data transmission device has the advantage of allowing the user to adjust it every 1 minute, where as the existing smart metering time is fixed at once every 15 minutes.