• Title/Summary/Keyword: 신뢰성 시험(reliability test)

Search Result 873, Processing Time 0.024 seconds

Analysis Study on Fire Performance with Internal Anchored Concrete Filled Steel Tube Columns According to Percent of Steel-Fibers (강섬유 콘크리트 혼입율에 따른 내부앵커형 콘크리트 충전기둥 내화성능에 관한 해석적 연구)

  • Kim, Sun Hee;Yom, Kong Soo;Kim, Yong Hwan;Choi, Sung Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.1
    • /
    • pp.23-34
    • /
    • 2016
  • Concrete filled steel tube system has two major advantages. First, the confinement effect of steel tube improves the compressive strength of concrete. Second, the load capacity and deformation capacity of members are improved because concrete restrains local buckling of steel tube. It does, however, involve workability problem of using stud bolts or anchor bolts to provide composite effect for larger cross-sections. While the ribs inside the columns are desirable in terms of compressive behavior, they cause the deterioration in load capacity upon in-plane deformation resulting from thermal deformation. Since the ribs are directly connected with the concrete, the deformation of the ribs accelerates concrete cracking. Thus, it is required to improve the toughness of the concrete to resist the deformation of the ribs. Welding built-up tubular square columns can secure safety in terms of fire resistance if the problem are solved. This study focuses on mixing steel fiber in the concrete to improve the ductility and toughness of the columns. In order to evaluate fire resistance performance, loaded heating test was conducted with 8 specimens. The behavior and thermal deformation capacity of the specimens were analyzed for major variables including load ratio. The reliability of heat transfer and thermal stress analysis model was verified through the comparison of the results between the test and previous study.

Evaluation of the Microstructure and Mechanical Properties for Ni Superalloy Materials Using HIP and Post Heat Treatment (HIP과 열처리공정을 이용한 Ni기 초합금 소재의 미세조직 및 기계적 특성 분석)

  • Kim, Youngdae;Hyun, Jungseob;Chang, Sungyong
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.2
    • /
    • pp.137-143
    • /
    • 2020
  • The CM247LC, a Ni-based superalloy material used for gas turbine hot gas path parts, is casted using directionally solidified technology to analyze the mechanical properties and microstructures through HIP (Hot Isostatic Pressing) and post-heat treatment, and to derive optimal HIP treatment conditions. The CM247LC material is being researched in various ways as an alternative material for prototyping gas turbine blades. In particular, the blade rotating part is exposed and operated in a high temperature and high-pressure environment, and when damaged, it may cause huge economic losses. Therefore, in order to use the CM247LC material as prototyping materials for gas turbine blades, the reliability of the microstructure and mechanical properties must be verified. In this study, after casting rod test specimens using CM247LC material by directionally solidified technology, after that the specimens were performed by HIP treatment and post-heat treatment to test two HIP conditions designed by KEPCO to derive the possibility of prototyping of CM247LC material and optimization of HIP treatment conditions. Additionally, the properties of CM247LC material were compared to the GTD111DS material using for 1,300℃ class gas turbine blades.

Effect of Sn Decorated MWCNT Particle on Microstructures and Bonding Strengths of the OSP Surface Finished FR-4 Components Assembled with Sn58%Bi Composite Solder Joints (OSP 표면처리된 FR-4 PCB기판과 Sn58%Bi 복합솔더 접합부의 미세조직 및 접합강도에 미치는 Sn-MWCNT의 영향)

  • Park, Hyun-Joon;Lee, Choong-Jae;Min, Kyung Deuk;Jung, Seung-Boo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.4
    • /
    • pp.163-169
    • /
    • 2019
  • Sn-Pb solder alloys in electronics rapidly has been replaced to Pb free solder alloys because of various environmental regulations such as restriction of hazardous substances directive (RoHS), European Union waste electrical, waste electrical and electronic equipment (WEEE), registration evaluation authorization and of chemicals (REACH) etc. Because Sn58%Bi (in wt.%) solder alloy has low melting point and higher mechanical properties than that of Sn-Pb solder, it has been studied to manufacture electronic components. However, the reliability of Sn58%Bi solder could be lowered because of the brittleness of Bi element included in the solder alloy. Therefore, we observed the microstructures of Sn58%Bi composite solders with various contents of Sn-decorated multiwalled carbon nanotube (Sn-MWCNT) particles and evaluated bonding strength of the FR-4 components assembled with Sn58%Bi composite solder. Also, microstructures and bonding strengths of the Sn58%Bi composite solder joints were evaluated with the number of reflows from 1 to 7 times, respectively. Bonding strengths and fracture energies of the Sn58%Bi composite solder joints were measured by die shear test. Microstructures and fracture modes were observed with scanning electron microscope (SEM). Microstructures in the Sn58%Bi composite solder joints were finer than that of only Sn58%Bi solder joint. Bonding strength and fracture energy of Sn58%Bi composite solder including 0.1 wt.% of Sn-decorated MWCNT particles increased up to 20.4% and 15.4% at 5 times in reflow, respectively.

A Study on Improving the Efficiency of Facility Safety Inspection Work Using Images (영상을 활용한 시설물 안전점검 작업 효율성 향상 방안 연구)

  • Jeon, Kyungsik;Kim, Jintae;Lee, Byoungkil
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.3
    • /
    • pp.179-186
    • /
    • 2021
  • In general, the daily safety inspection activities, which investigate damages in structures and measures the size of the damage, have been relied heavily on the visual inspection so far. Since the probe of the condition and performance of facilities by such personnel is often dependent on the subjective judgment of the investigator, the consistency and repeatability of the probing results may reduce. Particularly, damage located in a difficult-to-reach place depends mainly on experience with the naked eye, and an unsafe method using a ladder has mainly applied when necessary. Therefore, in this study, we tried to propose a way of using images that can reduce the deviation between safety inspection investigators, enhance objectivity, and improve the safety of workers. In this study, we have applied homographic transformation as a method of correcting the image. As a result of analyzing the size of the damage in the corrected image of the test subject, it confirms that the accuracy of measuring the magnitude of the damage can satisfy the target levels of 5.0mm and 0.005m2, the target accuracy levels. As a result of the field verification test to which the proposed image correction technique applied, the coefficient of variation of the crack length in the structure decreased from 5.4~7.0% to 0.072~0.12%, and that of the damaged area from 10.9% to 1.6%. It confirms that the measurement accuracy is improved. Therefore, it is expected that this study on the image utilization technique in safety inspection activities can increase the accuracy of damage measurement and improve the reliability of the safety inspection reports and exterior survey drawings.

Development of Analytical Reference Material for Proficiency Test of Pesticide Multi-residue Analysis in Green-pepper (풋고추 농약다성분분석 정도관리용 분석표준물질 개발)

  • Kim, Jong-Hwan;Choi, Sung-Gil;Oh, Young-Gon;Kwon, Young-Sang;Hong, Su-Myeong;Sung, Mun-Hyun;Lee, Se-Ja;Hwang, Sun-Young;Seo, Jong-Su
    • The Korean Journal of Pesticide Science
    • /
    • v.20 no.3
    • /
    • pp.211-220
    • /
    • 2016
  • This study was to develop the analytical reference material of green-pepper for multi-residue analysis of pesticides. According to the ISO Guide 35, ISO Guide 13528 and EURL-PT protocol, the homogeneity, stability, assigned value and uncertainty were calculated to assess if it was suitable to be used as the proficiency test or quality control. The values of the within-bottle standard variation ($s_{wb}$) and the between-bottle standard variation ($s_{bb}$) were 1.7~3.7% of assigned value according to the requirement of the ISO guide 35. And, the uncertainty ($u^*{_{bb}}$) due to inhomogeneity was 0.8~1.1% for all pesticides. The storage stabilities of ten-pesticides at various conditions were assessed. For all target pesticides, the slop ($b_1$) values were smaller than the corresponding values of $[t_{0.95,n-2}{\times}s(b_1)]$ specified by the ISO guide 35, indicating that there were no statistically significant decreases in the concentration of the target pesticides when the analytical reference material was stored at room temperature ($20{\sim}30^{\circ}C$) for 7 days, freezing ($-20^{\circ}C$) for 30 days and deep freezer ($-80^{\circ}C$. except for bifenthrin, fenpropathrin) for 245 days. For proficiency test by using it developed by Korea Institute of Toxicology, inter-lab test was performed with eight organization performing the residual pesticide analysis. We found that there were some different results among them. Some were assessed as questionable or unacceptable for two pesticides and one organization didn't analyze the six pesticides. From these results, this green-pepper analytical reference material containing ten-pesticides could be used as a tool for the proficiency test to improve the reliability or consistency for pesticide residue's results.

Correlation Analysis of Rail Surface Defects and Rail Internal Cracks (레일표면결함과 레일내부균열의 상관관계 분석)

  • Jung-Youl Choi;Jae-Min Han;Young-Ki Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.1
    • /
    • pp.585-590
    • /
    • 2024
  • In this study, rail surface defects are increasing due to the aging of urban railway rails, but in the detailed guidelines for track performance evaluation established by the country, rail surface damage is inspected with the naked eye of engineers and simple measuring tools. With the recent enactment of the Track Diagnosis Act, a large budget has been invested and the volume of rail diagnosis is rapidly increasing, but it is difficult to secure the reliability of diagnosis results using labor-intensive visual inspection techniques. It is very important to discover defects in the rail surface through periodic track tours and visual inspection. However, evaluating the severity of defects on the rail surface based on the subjective judgment of the inspector has significant limitations in predicting damage inside the rail. In this study, the rail internal crack characteristics due to rail surface damage were studied. In field measurements, rail surface damage locations were selected, samples of various damage types were collected, and the rail surface damage status was evaluated. In indoor testing, we intend to analyze the correlation between rail surface defects and internal defects using a electron scanning microscope (SEM). To determine the crack growth rate of urban railway rails currently in use, the Gaussian probability density function was applied and analyzed.

Folate retention in Namul according to various heating methods (다양한 열 처리방법에 대한 나물류의 엽산 잔존율)

  • Jung, Jae Eun;Jeong, Hea-Jeong;Hyun, Taisun;Park, Su-Jin;Chun, Jiyeon
    • Korean Journal of Food Science and Technology
    • /
    • v.51 no.5
    • /
    • pp.425-431
    • /
    • 2019
  • Selected leafy vegetables, widely used for Korean Namul dishes, were heat-treated in different ways and their folate retention was investigated. The Lactobacillus casei method was applied for folate estimation and validated to ensure reliability of analytical data. The folate content in Namul highly varied, from 29.7 to $293.4{\mu}g/100g$, depending on the heating methods and the types of vegetables. Most of the Namul variants showed increased folate content on heat treatment. Frying yielded higher folate retention than the other cooking methods (blanching, steaming, baking, and panfrying), and pig weed showed the highest folate retention (3.3 times, $293.4{\mu}g/100g$). L. casei assay for folate estimation showed 95.7% recovery and relative standard deviations less than 2% for both reproducibility and repeatability, indicating good accuracy and precision. Quality of the folate assay was assured by monitoring a quality control chart and a proficiency test (z-score= -0.1) during the entire of study.

A Study on System Retrofit of Complex Energy System (복합에너지시스템의 성능개선에 관한 연구)

  • Choi, Jung-Hun;Moon, Chae-Joo;Chang, Young-Hak
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.1
    • /
    • pp.61-68
    • /
    • 2021
  • The application of renewable energies such as wind and solar has become an inevitable choice for many countries in order to achieve the reduction of greenhouse gases and healthy economic development. However, due to the intermittent characteristics of renewable energy, the issue with integrating a larger proportion of renewable energy into the grid becomes more prominent. A complex energy system, usually consists of two or more renewable energy sources used together to provide increased system efficiency as well as greater balance in energy supply. Compared with the power system, control and optimization of the complex energy system become more difficult in terms of modeling, operation, and planning. The main purpose of the complex energy system retrofit for samado island with microgrid system is to coordinate the operation with various distributed energy resources, energy storage systems, and power grids to ensure its reliability, while reducing the operating costs and achieving the optimal economic benefits. This paper suggests the improved complex energy system of samado island with optimal microgrid system. The results of test operation show about 12% lower SOC variation band of ESS, elimination of operation limit in PV and reduction of operation time in diesel generator.

A Prediction of N-value Using Artificial Neural Network (인공신경망을 이용한 N치 예측)

  • Kim, Kwang Myung;Park, Hyoung June;Goo, Tae Hun;Kim, Hyung Chan
    • The Journal of Engineering Geology
    • /
    • v.30 no.4
    • /
    • pp.457-468
    • /
    • 2020
  • Problems arising during pile design works for plant construction, civil and architecture work are mostly come from uncertainty of geotechnical characteristics. In particular, obtaining the N-value measured through the Standard Penetration Test (SPT) is the most important data. However, it is difficult to obtain N-value by drilling investigation throughout the all target area. There are many constraints such as licensing, time, cost, equipment access and residential complaints etc. it is impossible to obtain geotechnical characteristics through drilling investigation within a short bidding period in overseas. The geotechnical characteristics at non-drilling investigation points are usually determined by the engineer's empirical judgment, which can leads to errors in pile design and quantity calculation causing construction delay and cost increase. It would be possible to overcome this problem if N-value could be predicted at the non-drilling investigation points using limited minimum drilling investigation data. This study was conducted to predicted the N-value using an Artificial Neural Network (ANN) which one of the Artificial intelligence (AI) method. An Artificial Neural Network treats a limited amount of geotechnical characteristics as a biological logic process, providing more reliable results for input variables. The purpose of this study is to predict N-value at the non-drilling investigation points through patterns which is studied by multi-layer perceptron and error back-propagation algorithms using the minimum geotechnical data. It has been reviewed the reliability of the values that predicted by AI method compared to the measured values, and we were able to confirm the high reliability as a result. To solving geotechnical uncertainty, we will perform sensitivity analysis of input variables to increase learning effect in next steps and it may need some technical update of program. We hope that our study will be helpful to design works in the future.

A Study on Wireless Broadband Internet RF Down Converter Design and Production (휴대무선인터넷 RF 하향 변환기 설계 및 제작에 관한 연구)

  • Lee, Chang-Hee;Won, Young-Jin;Lee, Jong-Yong;Lee, Sang-Hun;Lee, Won-Seok;Ra, Keuk-Hwan
    • 전자공학회논문지 IE
    • /
    • v.45 no.1
    • /
    • pp.31-37
    • /
    • 2008
  • A Wibro RF down converter of 2.3GHz band is designed and implemented in this paper. The problems that can occur in the receiver LNA(Low Noise Amplifier) to minimize additional purposes. In addition, 2.3GHz band from the 75 MHz downward to minimize the losses in the process, transform and improve efficiency, and achieve stable characteristics can be used to make high frequency characteristics of the device. Wibro repeater uses a TDMA(Time Division Multiplexing Access) method is needed because the RF switch. Production criterion specification, the input voltage from +8 V 1.2A of current consumption, 60dB gain and the noise figure of less than 2.5dB, VSWR(Voltage Standing Wave Ratio) less than 1.5, more than IMD(Inter Modulation Distortion) 60dB satisfied. Environmental conditions ($-20^{\circ}C$ to $70^{\circ}C$) to pass the test of reliability in a long time, that seemed crafted Wibro down converter be applied to the Wibro repeater.